HomeMy WebLinkAbout2026-10-06 6323 KITSAP WAY - Permits (9)&
AB
ABV
A/C
AD
ADD'L
ADJ
AFF
AHU
ALUM
AP
ARCH
BD
BLDG
BLKG
BLW
B.O.
CAB
CJ
CL
CLG
CLO
CLR
CMU
CU
CO
COL
CONC
CONSTR
CONT
CONTR
CTR
D
DBL
DIA
DIM
DN
DR
DS
DTL
DW
DWG
DWR
EA
EF
EL
ELEC
ELEV
EP
EQ
EW
EXP
EXST/EX
EXT
F.F.
FIN
FLR
FND
F.O.
FT
FTG
FURR
G
GA
GALV
GND
GPM
GR
GWB
H
HB
HD
HDW
HDWD
HT
HVAC
HWH
IRC
IN
ID
INCL
INSUL
INT
J
JT
L
LBS
MAS
MATL
MAX
MDF
MECH
MFR
MIN
M.O.
MTL
N
N/A
NIC
NO
NOM
NTS
O.C.
OD
OVHD
PNT/PTD
PL
PLUM
PLYWD
PR
PSD
PSI
P.T.
R
RAD
REF
REINF
REQ'D
REV
RM
R.O.
S
SCHED
SD
SECT
SF
SHT
SIM
SLVG
SPEC
SQ
STD
STL
STRUC
T
TBD
TEL
THK
THRESH
T.O.
TYP
UNF
UNO
UL
VAN
V.B.
VTR
W
W.
WC
WD
W/D
WDW
W/O
WP
AND
ANCHOR BOLT
ABOVE
AIR CONDITIONING
AREA DRAIN
ADDITIONAL
ADJUSTABLE
ABOVE FINISED FLOOR
AIR HANDLING UNIT
ALUMINUM
ACCESS PANEL
ARCHITECTURAL
BOARD
BUILDING
BLOCKING
BELOW
BOTTOM OF
CABINET
CONTROL JOINT
CENTER LINE
CEILING
CLOSET
CLEAR
CONCRETE MASONRY UNIT
CONDENSING UNIT
CARBON MONOXIDE DETECTOR
COLUMN
CONCRETE
CONSTRUCTION
CONTINUOUS
CONTRACTOR
CENTER
DEEP
DOUBLE
DIAMETER
DIMENSION
DOWN
DOOR
DOWN SPOUT
DETAIL
DISHWASHER
DRAWING
DRAWER
EACH
EXHAUST FAN
ELEVATION
ELECTRIC/ELECTRICAL
ELEVATOR
ELECTRIC PANEL
EQUAL
EACH WAY
EXPANSION
EXISTING
EXTERIOR
FINISHED FLOOR
FINISH
FLOOR
FOUNDATION
FACE OF
FEET
FOOTING
FURRING
GAS
GAUGE
GALVANIZED
GROUND
GALLONS PER MINUTE
GRADE
GYPSUM WALL BOARD
HIGH
HOSE BIBB
HEAD
HARDWARE
HARDWOOD
HEIGHT
HEATING, VENTILATION, AIR CONDITIONING
HOT WATER HEATER
INTERNATIONAL RESIDENTIAL CODE
INCHES
INSIDE DIAMETER
INCLUDED/INCLUDING
INSULATION
INTERIOR
JACK
JOINT
LENGTH
POUNDS
MASONRY
MATERIAL
MAXIMUM
MEDIUM DENSITY FIBERBOARD
MECHANICAL
MANUFACTURER
MINIMUM
MASONRY OPENING
METAL
NEW
NOT APPLICABLE
NOT IN CONTRACT
NUMBER
NOMINAL
NOT TO SCALE
ON CENTER
OUTSIDE DIAMETER
OVERHEAD
PAINT / PAINTED
PLATE
PLUMBING
PLYWOOD
PAIR
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
PRESSURE TREATED
RISER
RADIUS
REFRIGERATOR
REINFORCED
REQUIRED
REVISION
ROOM
ROUGH OPENING
SOUTH
SCHEDULE
SMOKE DETECTOR
SECTION
SQUARE FEET
SHEET
SIMILAR
SALVAGE
SPECIFICATION
SQUARE
STANDARD
STEEL
STRUCTURE
TREAD
TO BE DETERMINED
TELEPHONE
THICK
THRESHOLD
TOP OF
TYPICAL
UNFINISHED
UNLESS NOTED OTHERWISE
UNDERWRITERS LABORATORIES
VANITY
VAPOR BARRIER
VENT THROUGH ROOF
WIDE
WITH
WATER CLOSET
WOOD
WASHER / DRYER
WINDOW
WITHOUT
WATERPROOF
OVERALL DIMENSION - OUTSIDE FACE OF STUDS
EXTERIOR WALL LOCATION OUTSIDE FACE OF STUDS
..WINDOW/DOOR CENTERLINES .
5 1/2"
INTERIOR PARTITION LOCATIONS
5 1/2"
AND WALL THICKNESSES
3 1/2"
TO EACH FACE OF STUD
5 1/2"
APPROXIMATE DIMENSION
± 7' - 11"
FIXED DIMENSION
8' - 8"
DOOR NUMBER
PER SCHEDULE
DOOR WIDTH
DOOR TAG WINDOW TAG
WINDOW TYPE
PER SCHEDULE ROOM NUMBER
PER SCHEDULE
ROOM TAG
ROOM AREA
1t101
36"
Room name
101
150 SF
CONCRETE EARTH GRAVEL RIGID INSULATION
BOARD
BATT INSULATIONLOOSE FILL
INSULATION
LOOSE FILL
INSULATION
PLYWOOD WOOD METAL ROOF ASPHALT
SHINGLES
WOOD FLOORING LOOSE FILL
INSULATION
KEYNOTE
KEYNOTE NUMBER, REFER
TO SCHEDULE
ALIGN FINISHED SURFACES SECTION MARK
DRAWING NUMBER
SHEET NUMBER
STORY ELEVATION
1
ALIGN 1
A101
Name
Elevation
Scale
BNA Project number:PLOT DATE:103 91st Ave SE, Lake
Stevens. WA 98258 4254780327
www.drift-ia.com
STATUS:
REVISION LOG
REV #DATE DESCRIPTION
DRAWN BY:
SHEET NO.
SHEET NAME
NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION
NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION CLIENT NAMEPROJECT ADDRESSBUILDER NAMEBUILDER ADDRESSBUILDER CONTACTRegistered Architect in WA State
DPS PERMIT NUMBER:FILE PATH:ORIGINAL DRAWING SIZE IS 36" X 24" DO NOT SCALE DRAWINGS FOR MEASUREMENTS
1/4" = 1'-0"9/18/2023 11:35:00 PMC:\Users\Jt\OneDrive - drift-ia.com\Projects\01 RESIDENTIAL\Bremerton Apartments\03 Revit\01 Work\D-IA-RA-BremertonApartments-SD-R0-V23.rvtCOVER SHEET
XXXXXX
G001CLIENT NAMEXXXPERMITTWO LIGHTS PROPERTIESOWNER NAMES
OWNER
P R O J E C T
T E A M
DRIFT INTERIOR ARCHITECTURE- PERMITTING
ARCHITECT14526 107TH ST NE
LAKE STEVENS, WA
(E): JEN@DRIFT-IA.COM
(P): 425-478-0327
CONTACT: JEN TAMBLIN
BUILDER NAME
ENGINEER ADDRESS
D R A W I N G
I N D E X
A B B R E V I A T I O N S D R A W I N G S T A N D A R D S
D I M E N S I O N M E T H O D
D R A W I N G S Y M B O L S
C O M M O N M A T E R I A L S
S C O P E O F W O R K
PERMITTING OF EXISTING PROJECT, CONVERSION OF RESIDENTIAL TO MULFI FAMLY. STOP WORK ORDER ISSUED, AS BUILT DRAWINGS AND
RECOMENDATIONS ARE PROVIDED HERE.
SITE
P R O J E C T L O C A T I O N
TWO LIGHTS PROPERTIES
BUILDER
STRUCTURAL ENGINEER
BUILDER ADDRESS
ENGINEER ADDRESS
ADDRESS:
PARCEL:
ZONE:
6323 KITSAP WAY
172401-1-101-2004
CITY
N
C O D E S
2018 INTERNATIONAL RESIDENTIAL CODE
2018 INTERNATIONAL BUILDING CODE
2018 INTERNATIONAL MECHANICAL CODE
2018 UNIFORM PLUMBING CODE
2018 INTERNATIONAL MECHANICAL CODE
2018 INTERNATIONAL FIRE CODE
2018 WASHINGTON STATE ENERGY CODE
5B (EXISTING)
5B (PROPOSED)
NONE EXISTING.CITY TO CONFIRM
IF 13R COMPLY IF INSTALLED IN
RESIDENTIAL LOBBY ONLY.
CONSTRUCTION TYPE:
SPRINKLERS:
C O D E S
3D VIEW OF THE
PROJECT
OTHER CONSULTANT
OTHER CONSULTANT
OTHER ADDRESS
?
UP
A200
1
A2012
A201
1
A200 2
3' - 10"8' - 8"7' - 10"8' - 7 1/2"
9' - 3"
7' - 0"
22' - 7"
BEDROOM 1
WIC
LIVING/DINING
BEDROOM 2
STORAGE
BATH
3' - 0 1/4"6' - 0"2' - 6"2' - 7 1/2"
EF
EF
821 SF
UNIT E
6
SD
SD
10' - 7"STAIRS TO LAUNDRY
NO EGRESS WINDOWS LOCATED IN
BEDROOM SPACE. THIS COULD
POSSIBLE BECOME A STUDIO OR AN
OPEN 1, BUT THE BACK ROOM CANT
BE A BEDROOM. DELETE CLOSET
MECH
DELETE WALL, MAKE
OPEN 1, PROVIDE
WHOLE HOUSE FAN
N
1. ALL DIMENSIONS ARE FROM FACE OF STUD OF NEW WALLS AND FINISHED
SURFACE OF EXISTING WALLS UNLESS OTHERWISE NOTED.
2. TYPICAL INTERIOR PARTITION IS 2x4 STUD @ 16" O.C. WITH ONE LAYER OF
1/2" GYP BOARD ON EACH SIDE, EXCEPT WHERE NOTED ON PLANS. USE
2x6 STUDS AT PLUMBING WALLS.
3. 50 CFM EXHAUST FAN AT ALL NEW BATHROOMS
8. ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING
WIRING WITH BATTERY BACK-UP. WIRING SHALL BE PERMANENT AND
WITHOUT A DISCONNECTING SWITCH OTHER THAN THOSE REQUIRED
FOR OVERCURRENT PROTECTION. SMOKE ALARMS SHALL BE
INTERCONNECTED AND COMPLY WITH HOUSEHOLD FIRE WARNING
EQUIPMENT PROVISIONS OF NFPA 72. CONTRACTOR TO PULL FIRE ALARM
PERMIT FOR APPROPRIATE FIRE ALARM SYSTEM INSTALLER.-VERIFY
9. KITCHEN EXHAUST FAN TO BE A MINIMUM OF 100 CFM-VERIFY
10. BATHROOM EXHAUST FAN TO BE A MINIMUM OF 50 CFM-VERIFY
11.FIREPLACE IN LOBBY TO BE REMOVED
STAIR NOTES: EXISTING STAIRS TO REMAIN
NEW CONSTRUCTION
EXISTING TO REMAIN
TO BE DONE:
• CONTRACTOR TO INTALL C02 DETECTORS OUTSIDE EACH LIVING AREA
• CONTRACTOR TO VERIFY BATHROOM EXHAUST COMPLIES WITH IRC
• CONTRACTOR TO INSTALL 2O MINUTE DOORS AT RESIDENTIAL LOBBY
• CONTRACTOR TO VERIFY CEILING HEIGHTS IN UNIT C BEDROOM
• CONTRACTOR TO INSTALL ADA PATHWAY TO LAUNDRY ROOM
• CONTRACTOR TO REMOVE CLOSETS IN UNIT E, CONVERT TO OPEN 1
BEDROOM
• CONTRACTOR TO VERIFY KITCHEN EXHAUST COMPLIES WITH IRC
• NO NEW WINDOWS HAVE BEEN INSTALLED
• NO NEW WORK TO EXTERIOR WALLS
• ALL INTERIOR DEMISING WALLS BETWEEN UNITS ARE CONFIRMED AT
1HR RATING
• CONTRACTOR TO CONVERT UNIT A TO ADA UNIT PER FHA
REQUIREMENTS
Scale
BNA Project number:PLOT DATE:103 91st Ave SE, Lake
Stevens. WA 98258 4254780327
www.drift-ia.com
STATUS:
REVISION LOG
REV #DATE DESCRIPTION
DRAWN BY:
SHEET NO.
SHEET NAME
NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION
NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION CLIENT NAMEPROJECT ADDRESSBUILDER NAMEBUILDER ADDRESSBUILDER CONTACTRegistered Architect in WA State
DPS PERMIT NUMBER:FILE PATH:ORIGINAL DRAWING SIZE IS 36" X 24" DO NOT SCALE DRAWINGS FOR MEASUREMENTS
1/4" = 1'-0"9/18/2023 11:34:55 PMC:\Users\Jt\OneDrive - drift-ia.com\Projects\01 RESIDENTIAL\Bremerton Apartments\03 Revit\01 Work\D-IA-RA-BremertonApartments-SD-R0-V23.rvtBASEMENT LEVEL
XXXXXX
Author
A001CLIENT NAMEXXXPERMITTWO LIGHTS PROPERTIES1/4" = 1'-0"1 Basement floor
FLOOR PLAN GENERAL NOTES
FLOOR PLAN KEYNOTES
UP
DN
DN
??
DN
?1. ALL DIMENSIONS ARE FROM FACE OF STUD OF NEW WALLS AND FINISHED
SURFACE OF EXISTING WALLS UNLESS OTHERWISE NOTED.
2. TYPICAL INTERIOR PARTITION IS 2x4 STUD @ 16" O.C. WITH ONE LAYER OF
1/2" GYP BOARD ON EACH SIDE, EXCEPT WHERE NOTED ON PLANS. USE
2x6 STUDS AT PLUMBING WALLS.
3. 50 CFM EXHAUST FAN AT ALL NEW BATHROOMS
8. ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING
WIRING WITH BATTERY BACK-UP. WIRING SHALL BE PERMANENT AND
WITHOUT A DISCONNECTING SWITCH OTHER THAN THOSE REQUIRED
FOR OVERCURRENT PROTECTION. SMOKE ALARMS SHALL BE
INTERCONNECTED AND COMPLY WITH HOUSEHOLD FIRE WARNING
EQUIPMENT PROVISIONS OF NFPA 72. CONTRACTOR TO PULL FIRE ALARM
PERMIT FOR APPROPRIATE FIRE ALARM SYSTEM INSTALLER.-VERIFY
9. KITCHEN EXHAUST FAN TO BE A MINIMUM OF 100 CFM-VERIFY
10. BATHROOM EXHAUST FAN TO BE A MINIMUM OF 50 CFM-VERIFY
11.FIREPLACE IN LOBBY TO BE REMOVED
STAIR NOTES: EXISTING STAIRS TO REMAIN
NEW CONSTRUCTION
EXISTING TO REMAIN
TO BE DONE:
• CONTRACTOR TO INTALL C02 DETECTORS OUTSIDE EACH LIVING AREA
• CONTRACTOR TO VERIFY BATHROOM EXHAUST COMPLIES WITH IRC
• CONTRACTOR TO INSTALL 2O MINUTE DOORS AT RESIDENTIAL LOBBY
• CONTRACTOR TO VERIFY CEILING HEIGHTS IN UNIT C BEDROOM
• CONTRACTOR TO INSTALL ADA PATHWAY TO LAUNDRY ROOM
• CONTRACTOR TO REMOVE CLOSETS IN UNIT E, CONVERT TO OPEN 1
BEDROOM
• CONTRACTOR TO VERIFY KITCHEN EXHAUST COMPLIES WITH IRC
• NO NEW WINDOWS HAVE BEEN INSTALLED
• NO NEW WORK TO EXTERIOR WALLS
• ALL INTERIOR DEMISING WALLS BETWEEN UNITS ARE CONFIRMED AT
1HR RATING
• CONTRACTOR TO CONVERT UNIT A TO ADA UNIT PER FHA
REQUIREMENTS
A200
1
A2012
A201
1
A200 2
14' - 8"24' - 1 1/2"6" STEP
6" STEP
E-FIREPLACE, NON
OPERABLE 7' - 6"12' - 8"
12' - 0"
3' - 0"7' - 2"10' - 7"10' - 6"2' - 3"
6" STEP
OPENING IN WALL
666 SF
UNIT A
2
BED 1
BED 2
WIC
LR/D
MECH
LAUNDRY
817 SF
UNIT B
3
LAUNDRY
EGRESS
2' - 0"
EGRESS
2' - 0"4' - 0"3' - 0"2' - 6"6' - 3 3/4"5' - 5"DW2' - 0"1' - 3 3/4"261 SF
LOBBY
4
449 SF
UNIT D
5
SD
SDSD
SD
EF
EF
EF
POSSIBLE ADA
UNIT, ADD RAMP
ADD RAMP HERE
TAKE THIS AND MAKE
INTO ADA BATHROOM
POSSIBLY, NEEDS
TURNING RADIUS
1 HR WALL
CONRTACTOR TO
CONFIRM IF SD ARE ALSO
C02 DETECTORS
NEEDS 1" MORE OPEN,
28" CLEAR
POSSIBLE DROPPED COUNTER WORKSPACE LOCATION
1 HOUR RATED WALL
CONTRACTOR TO
REPLACE DOORS WITH
20 MINUTE RATED
DOORS
PARKING SPOTS,
CONTRACTOR TO DELINEATE
AND INDICATE ADA SPOT
ADD ADA
WALKWAY TO
LAUNDRY
BR
LR/DR
BA
ADA
VAN STALL
5' - 0"10' - 0"ROAD ACCESS TO LOWER LEVELN Scale
BNA Project number:PLOT DATE:103 91st Ave SE, Lake
Stevens. WA 98258 4254780327
www.drift-ia.com
STATUS:
REVISION LOG
REV #DATE DESCRIPTION
DRAWN BY:
SHEET NO.
SHEET NAME
NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION
NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION CLIENT NAMEPROJECT ADDRESSBUILDER NAMEBUILDER ADDRESSBUILDER CONTACTRegistered Architect in WA State
DPS PERMIT NUMBER:FILE PATH:ORIGINAL DRAWING SIZE IS 36" X 24" DO NOT SCALE DRAWINGS FOR MEASUREMENTS
1/4" = 1'-0"9/18/2023 11:34:56 PMC:\Users\Jt\OneDrive - drift-ia.com\Projects\01 RESIDENTIAL\Bremerton Apartments\03 Revit\01 Work\D-IA-RA-BremertonApartments-SD-R0-V23.rvtFLOOR PLAN
XXXXXX
Author
A100CLIENT NAMEXXXPERMITTWO LIGHTS PROPERTIESFLOOR PLAN GENERAL NOTES
FLOOR PLAN KEYNOTES
1/4" = 1'-0"1 FIRST FLOOR
EF
EF
DN?A200
1
A2012
A201
1
A200 2
LAUNDRY
10" STEP UP, VERIFY
CONTRACTOR TO
VERIFY CEILING
HEIGHT AND PORTION
OF CEILING THAT IS
CODE COMPLIANT
(7'-0")
CLOSET
CLOSET
SD
ALL WINDOWS EXISTING
1011 SF
UNIT D
7
EF
EF
EF
BR
LR/DR
BA
MECH
N
ROOF
ROOF
ROOF
1. ALL DIMENSIONS ARE FROM FACE OF STUD OF NEW WALLS AND FINISHED
SURFACE OF EXISTING WALLS UNLESS OTHERWISE NOTED.
2. TYPICAL INTERIOR PARTITION IS 2x4 STUD @ 16" O.C. WITH ONE LAYER OF
1/2" GYP BOARD ON EACH SIDE, EXCEPT WHERE NOTED ON PLANS. USE
2x6 STUDS AT PLUMBING WALLS.
3. 50 CFM EXHAUST FAN AT ALL NEW BATHROOMS
8. ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING
WIRING WITH BATTERY BACK-UP. WIRING SHALL BE PERMANENT AND
WITHOUT A DISCONNECTING SWITCH OTHER THAN THOSE REQUIRED
FOR OVERCURRENT PROTECTION. SMOKE ALARMS SHALL BE
INTERCONNECTED AND COMPLY WITH HOUSEHOLD FIRE WARNING
EQUIPMENT PROVISIONS OF NFPA 72. CONTRACTOR TO PULL FIRE ALARM
PERMIT FOR APPROPRIATE FIRE ALARM SYSTEM INSTALLER.-VERIFY
9. KITCHEN EXHAUST FAN TO BE A MINIMUM OF 100 CFM-VERIFY
10. BATHROOM EXHAUST FAN TO BE A MINIMUM OF 50 CFM-VERIFY
11.FIREPLACE IN LOBBY TO BE REMOVED
STAIR NOTES: EXISTING STAIRS TO REMAIN
NEW CONSTRUCTION
EXISTING TO REMAIN
TO BE DONE:
• CONTRACTOR TO INTALL C02 DETECTORS OUTSIDE EACH LIVING AREA
• CONTRACTOR TO VERIFY BATHROOM EXHAUST COMPLIES WITH IRC
• CONTRACTOR TO INSTALL 2O MINUTE DOORS AT RESIDENTIAL LOBBY
• CONTRACTOR TO VERIFY CEILING HEIGHTS IN UNIT C BEDROOM
• CONTRACTOR TO INSTALL ADA PATHWAY TO LAUNDRY ROOM
• CONTRACTOR TO REMOVE CLOSETS IN UNIT E, CONVERT TO OPEN 1
BEDROOM
• CONTRACTOR TO VERIFY KITCHEN EXHAUST COMPLIES WITH IRC
• NO NEW WINDOWS HAVE BEEN INSTALLED
• NO NEW WORK TO EXTERIOR WALLS
• ALL INTERIOR DEMISING WALLS BETWEEN UNITS ARE CONFIRMED AT
1HR RATING
• CONTRACTOR TO CONVERT UNIT A TO ADA UNIT PER FHA
REQUIREMENTS
Scale
BNA Project number:PLOT DATE:103 91st Ave SE, Lake
Stevens. WA 98258 4254780327
www.drift-ia.com
STATUS:
REVISION LOG
REV #DATE DESCRIPTION
DRAWN BY:
SHEET NO.
SHEET NAME
NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION
NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION CLIENT NAMEPROJECT ADDRESSBUILDER NAMEBUILDER ADDRESSBUILDER CONTACTRegistered Architect in WA State
DPS PERMIT NUMBER:FILE PATH:ORIGINAL DRAWING SIZE IS 36" X 24" DO NOT SCALE DRAWINGS FOR MEASUREMENTS
1/4" = 1'-0"9/18/2023 11:34:57 PMC:\Users\Jt\OneDrive - drift-ia.com\Projects\01 RESIDENTIAL\Bremerton Apartments\03 Revit\01 Work\D-IA-RA-BremertonApartments-SD-R0-V23.rvtLEVEL 2 PLAN
XXXXXX
Author
A101CLIENT NAMEXXXPERMITTWO LIGHTS PROPERTIES1/4" = 1'-0"1 Second floor
FLOOR PLAN GENERAL NOTES
FLOOR PLAN KEYNOTES
FIRST FLOOR
0' -0"
FIRST FLOOR
0' -0"
First floor
0' -0"
First floor
0' -0"
Second floor
9' -1"
Second floor
9' -1"
Basement floor
-9' -11"
Basement floor
-9' -11"
Third floor
20' -6"
Third floor
20' -6"
Scale
BNA Project number:PLOT DATE:103 91st Ave SE, Lake
Stevens. WA 98258 4254780327
www.drift-ia.com
STATUS:
REVISION LOG
REV #DATE DESCRIPTION
DRAWN BY:
SHEET NO.
SHEET NAME CLIENT NAMEPROJECT ADDRESSBUILDER NAMEBUILDER ADDRESSBUILDER CONTACTRegistered Architect in WA State
DPS PERMIT NUMBER:FILE PATH:ORIGINAL DRAWING SIZE IS 36" X 24" DO NOT SCALE DRAWINGS FOR MEASUREMENTS
1/4" = 1'-0"9/18/2023 11:34:58 PMC:\Users\Jt\OneDrive - drift-ia.com\Projects\01 RESIDENTIAL\Bremerton Apartments\03 Revit\01 Work\D-IA-RA-BremertonApartments-SD-R0-V23.rvtBUILDING ELEVATION
XXXXXX
Author
A200CLIENT NAMEXXXPERMITTWO LIGHTS PROPERTIESELEVATION GENERAL NOTES
ELEVATION KEYNOTES
1/4" = 1'-0"1 FRONT ELEVATION
1/4" = 1'-0"2 LEFT ELEVATION
FIRST FLOOR
0' -0"
FIRST FLOOR
0' -0"
Second floor
9' -1"
Second floor
9' -1"
Basement floor
-9' -11"
Basement floor
-9' -11"
Third floor
20' -6"
Third floor
20' -6"
Scale
BNA Project number:PLOT DATE:103 91st Ave SE, Lake
Stevens. WA 98258 4254780327
www.drift-ia.com
STATUS:
REVISION LOG
REV #DATE DESCRIPTION
DRAWN BY:
SHEET NO.
SHEET NAME
NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION
NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION CLIENT NAMEPROJECT ADDRESSBUILDER NAMEBUILDER ADDRESSBUILDER CONTACTRegistered Architect in WA State
DPS PERMIT NUMBER:FILE PATH:ORIGINAL DRAWING SIZE IS 36" X 24" DO NOT SCALE DRAWINGS FOR MEASUREMENTS
1/4" = 1'-0"9/18/2023 11:34:59 PMC:\Users\Jt\OneDrive - drift-ia.com\Projects\01 RESIDENTIAL\Bremerton Apartments\03 Revit\01 Work\D-IA-RA-BremertonApartments-SD-R0-V23.rvtBUILDING ELEVATION Copy
1
XXXXXX
Author
A201CLIENT NAMEXXXPERMITTWO LIGHTS PROPERTIES1/4" = 1'-0"1 REAR ELEVATION
1/4" = 1'-0"2 RIGHT ELEVATION