Loading...
HomeMy WebLinkAbout2026-10-06 6323 KITSAP WAY - Permits (9)& AB ABV A/C AD ADD'L ADJ AFF AHU ALUM AP ARCH BD BLDG BLKG BLW B.O. CAB CJ CL CLG CLO CLR CMU CU CO COL CONC CONSTR CONT CONTR CTR D DBL DIA DIM DN DR DS DTL DW DWG DWR EA EF EL ELEC ELEV EP EQ EW EXP EXST/EX EXT F.F. FIN FLR FND F.O. FT FTG FURR G GA GALV GND GPM GR GWB H HB HD HDW HDWD HT HVAC HWH IRC IN ID INCL INSUL INT J JT L LBS MAS MATL MAX MDF MECH MFR MIN M.O. MTL N N/A NIC NO NOM NTS O.C. OD OVHD PNT/PTD PL PLUM PLYWD PR PSD PSI P.T. R RAD REF REINF REQ'D REV RM R.O. S SCHED SD SECT SF SHT SIM SLVG SPEC SQ STD STL STRUC T TBD TEL THK THRESH T.O. TYP UNF UNO UL VAN V.B. VTR W W. WC WD W/D WDW W/O WP AND ANCHOR BOLT ABOVE AIR CONDITIONING AREA DRAIN ADDITIONAL ADJUSTABLE ABOVE FINISED FLOOR AIR HANDLING UNIT ALUMINUM ACCESS PANEL ARCHITECTURAL BOARD BUILDING BLOCKING BELOW BOTTOM OF CABINET CONTROL JOINT CENTER LINE CEILING CLOSET CLEAR CONCRETE MASONRY UNIT CONDENSING UNIT CARBON MONOXIDE DETECTOR COLUMN CONCRETE CONSTRUCTION CONTINUOUS CONTRACTOR CENTER DEEP DOUBLE DIAMETER DIMENSION DOWN DOOR DOWN SPOUT DETAIL DISHWASHER DRAWING DRAWER EACH EXHAUST FAN ELEVATION ELECTRIC/ELECTRICAL ELEVATOR ELECTRIC PANEL EQUAL EACH WAY EXPANSION EXISTING EXTERIOR FINISHED FLOOR FINISH FLOOR FOUNDATION FACE OF FEET FOOTING FURRING GAS GAUGE GALVANIZED GROUND GALLONS PER MINUTE GRADE GYPSUM WALL BOARD HIGH HOSE BIBB HEAD HARDWARE HARDWOOD HEIGHT HEATING, VENTILATION, AIR CONDITIONING HOT WATER HEATER INTERNATIONAL RESIDENTIAL CODE INCHES INSIDE DIAMETER INCLUDED/INCLUDING INSULATION INTERIOR JACK JOINT LENGTH POUNDS MASONRY MATERIAL MAXIMUM MEDIUM DENSITY FIBERBOARD MECHANICAL MANUFACTURER MINIMUM MASONRY OPENING METAL NEW NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE ON CENTER OUTSIDE DIAMETER OVERHEAD PAINT / PAINTED PLATE PLUMBING PLYWOOD PAIR POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH PRESSURE TREATED RISER RADIUS REFRIGERATOR REINFORCED REQUIRED REVISION ROOM ROUGH OPENING SOUTH SCHEDULE SMOKE DETECTOR SECTION SQUARE FEET SHEET SIMILAR SALVAGE SPECIFICATION SQUARE STANDARD STEEL STRUCTURE TREAD TO BE DETERMINED TELEPHONE THICK THRESHOLD TOP OF TYPICAL UNFINISHED UNLESS NOTED OTHERWISE UNDERWRITERS LABORATORIES VANITY VAPOR BARRIER VENT THROUGH ROOF WIDE WITH WATER CLOSET WOOD WASHER / DRYER WINDOW WITHOUT WATERPROOF OVERALL DIMENSION - OUTSIDE FACE OF STUDS EXTERIOR WALL LOCATION OUTSIDE FACE OF STUDS ..WINDOW/DOOR CENTERLINES . 5 1/2" INTERIOR PARTITION LOCATIONS 5 1/2" AND WALL THICKNESSES 3 1/2" TO EACH FACE OF STUD 5 1/2" APPROXIMATE DIMENSION ± 7' - 11" FIXED DIMENSION 8' - 8" DOOR NUMBER PER SCHEDULE DOOR WIDTH DOOR TAG WINDOW TAG WINDOW TYPE PER SCHEDULE ROOM NUMBER PER SCHEDULE ROOM TAG ROOM AREA 1t101 36" Room name 101 150 SF CONCRETE EARTH GRAVEL RIGID INSULATION BOARD BATT INSULATIONLOOSE FILL INSULATION LOOSE FILL INSULATION PLYWOOD WOOD METAL ROOF ASPHALT SHINGLES WOOD FLOORING LOOSE FILL INSULATION KEYNOTE KEYNOTE NUMBER, REFER TO SCHEDULE ALIGN FINISHED SURFACES SECTION MARK DRAWING NUMBER SHEET NUMBER STORY ELEVATION 1 ALIGN 1 A101 Name Elevation Scale BNA Project number:PLOT DATE:103 91st Ave SE, Lake Stevens. WA 98258 4254780327 www.drift-ia.com STATUS: REVISION LOG REV #DATE DESCRIPTION DRAWN BY: SHEET NO. SHEET NAME NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION CLIENT NAMEPROJECT ADDRESSBUILDER NAMEBUILDER ADDRESSBUILDER CONTACTRegistered Architect in WA State DPS PERMIT NUMBER:FILE PATH:ORIGINAL DRAWING SIZE IS 36" X 24" DO NOT SCALE DRAWINGS FOR MEASUREMENTS 1/4" = 1'-0"9/18/2023 11:35:00 PMC:\Users\Jt\OneDrive - drift-ia.com\Projects\01 RESIDENTIAL\Bremerton Apartments\03 Revit\01 Work\D-IA-RA-BremertonApartments-SD-R0-V23.rvtCOVER SHEET XXXXXX G001CLIENT NAMEXXXPERMITTWO LIGHTS PROPERTIESOWNER NAMES OWNER P R O J E C T T E A M DRIFT INTERIOR ARCHITECTURE- PERMITTING ARCHITECT14526 107TH ST NE LAKE STEVENS, WA (E): JEN@DRIFT-IA.COM (P): 425-478-0327 CONTACT: JEN TAMBLIN BUILDER NAME ENGINEER ADDRESS D R A W I N G I N D E X A B B R E V I A T I O N S D R A W I N G S T A N D A R D S D I M E N S I O N M E T H O D D R A W I N G S Y M B O L S C O M M O N M A T E R I A L S S C O P E O F W O R K PERMITTING OF EXISTING PROJECT, CONVERSION OF RESIDENTIAL TO MULFI FAMLY. STOP WORK ORDER ISSUED, AS BUILT DRAWINGS AND RECOMENDATIONS ARE PROVIDED HERE. SITE P R O J E C T L O C A T I O N TWO LIGHTS PROPERTIES BUILDER STRUCTURAL ENGINEER BUILDER ADDRESS ENGINEER ADDRESS ADDRESS: PARCEL: ZONE: 6323 KITSAP WAY 172401-1-101-2004 CITY N C O D E S 2018 INTERNATIONAL RESIDENTIAL CODE 2018 INTERNATIONAL BUILDING CODE 2018 INTERNATIONAL MECHANICAL CODE 2018 UNIFORM PLUMBING CODE 2018 INTERNATIONAL MECHANICAL CODE 2018 INTERNATIONAL FIRE CODE 2018 WASHINGTON STATE ENERGY CODE 5B (EXISTING) 5B (PROPOSED) NONE EXISTING.CITY TO CONFIRM IF 13R COMPLY IF INSTALLED IN RESIDENTIAL LOBBY ONLY. CONSTRUCTION TYPE: SPRINKLERS: C O D E S 3D VIEW OF THE PROJECT OTHER CONSULTANT OTHER CONSULTANT OTHER ADDRESS ? UP A200 1 A2012 A201 1 A200 2 3' - 10"8' - 8"7' - 10"8' - 7 1/2" 9' - 3" 7' - 0" 22' - 7" BEDROOM 1 WIC LIVING/DINING BEDROOM 2 STORAGE BATH 3' - 0 1/4"6' - 0"2' - 6"2' - 7 1/2" EF EF 821 SF UNIT E 6 SD SD 10' - 7"STAIRS TO LAUNDRY NO EGRESS WINDOWS LOCATED IN BEDROOM SPACE. THIS COULD POSSIBLE BECOME A STUDIO OR AN OPEN 1, BUT THE BACK ROOM CANT BE A BEDROOM. DELETE CLOSET MECH DELETE WALL, MAKE OPEN 1, PROVIDE WHOLE HOUSE FAN N 1. ALL DIMENSIONS ARE FROM FACE OF STUD OF NEW WALLS AND FINISHED SURFACE OF EXISTING WALLS UNLESS OTHERWISE NOTED. 2. TYPICAL INTERIOR PARTITION IS 2x4 STUD @ 16" O.C. WITH ONE LAYER OF 1/2" GYP BOARD ON EACH SIDE, EXCEPT WHERE NOTED ON PLANS. USE 2x6 STUDS AT PLUMBING WALLS. 3. 50 CFM EXHAUST FAN AT ALL NEW BATHROOMS 8. ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WITH BATTERY BACK-UP. WIRING SHALL BE PERMANENT AND WITHOUT A DISCONNECTING SWITCH OTHER THAN THOSE REQUIRED FOR OVERCURRENT PROTECTION. SMOKE ALARMS SHALL BE INTERCONNECTED AND COMPLY WITH HOUSEHOLD FIRE WARNING EQUIPMENT PROVISIONS OF NFPA 72. CONTRACTOR TO PULL FIRE ALARM PERMIT FOR APPROPRIATE FIRE ALARM SYSTEM INSTALLER.-VERIFY 9. KITCHEN EXHAUST FAN TO BE A MINIMUM OF 100 CFM-VERIFY 10. BATHROOM EXHAUST FAN TO BE A MINIMUM OF 50 CFM-VERIFY 11.FIREPLACE IN LOBBY TO BE REMOVED STAIR NOTES: EXISTING STAIRS TO REMAIN NEW CONSTRUCTION EXISTING TO REMAIN TO BE DONE: • CONTRACTOR TO INTALL C02 DETECTORS OUTSIDE EACH LIVING AREA • CONTRACTOR TO VERIFY BATHROOM EXHAUST COMPLIES WITH IRC • CONTRACTOR TO INSTALL 2O MINUTE DOORS AT RESIDENTIAL LOBBY • CONTRACTOR TO VERIFY CEILING HEIGHTS IN UNIT C BEDROOM • CONTRACTOR TO INSTALL ADA PATHWAY TO LAUNDRY ROOM • CONTRACTOR TO REMOVE CLOSETS IN UNIT E, CONVERT TO OPEN 1 BEDROOM • CONTRACTOR TO VERIFY KITCHEN EXHAUST COMPLIES WITH IRC • NO NEW WINDOWS HAVE BEEN INSTALLED • NO NEW WORK TO EXTERIOR WALLS • ALL INTERIOR DEMISING WALLS BETWEEN UNITS ARE CONFIRMED AT 1HR RATING • CONTRACTOR TO CONVERT UNIT A TO ADA UNIT PER FHA REQUIREMENTS Scale BNA Project number:PLOT DATE:103 91st Ave SE, Lake Stevens. WA 98258 4254780327 www.drift-ia.com STATUS: REVISION LOG REV #DATE DESCRIPTION DRAWN BY: SHEET NO. SHEET NAME NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION CLIENT NAMEPROJECT ADDRESSBUILDER NAMEBUILDER ADDRESSBUILDER CONTACTRegistered Architect in WA State DPS PERMIT NUMBER:FILE PATH:ORIGINAL DRAWING SIZE IS 36" X 24" DO NOT SCALE DRAWINGS FOR MEASUREMENTS 1/4" = 1'-0"9/18/2023 11:34:55 PMC:\Users\Jt\OneDrive - drift-ia.com\Projects\01 RESIDENTIAL\Bremerton Apartments\03 Revit\01 Work\D-IA-RA-BremertonApartments-SD-R0-V23.rvtBASEMENT LEVEL XXXXXX Author A001CLIENT NAMEXXXPERMITTWO LIGHTS PROPERTIES1/4" = 1'-0"1 Basement floor FLOOR PLAN GENERAL NOTES FLOOR PLAN KEYNOTES UP DN DN ?? DN ?1. ALL DIMENSIONS ARE FROM FACE OF STUD OF NEW WALLS AND FINISHED SURFACE OF EXISTING WALLS UNLESS OTHERWISE NOTED. 2. TYPICAL INTERIOR PARTITION IS 2x4 STUD @ 16" O.C. WITH ONE LAYER OF 1/2" GYP BOARD ON EACH SIDE, EXCEPT WHERE NOTED ON PLANS. USE 2x6 STUDS AT PLUMBING WALLS. 3. 50 CFM EXHAUST FAN AT ALL NEW BATHROOMS 8. ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WITH BATTERY BACK-UP. WIRING SHALL BE PERMANENT AND WITHOUT A DISCONNECTING SWITCH OTHER THAN THOSE REQUIRED FOR OVERCURRENT PROTECTION. SMOKE ALARMS SHALL BE INTERCONNECTED AND COMPLY WITH HOUSEHOLD FIRE WARNING EQUIPMENT PROVISIONS OF NFPA 72. CONTRACTOR TO PULL FIRE ALARM PERMIT FOR APPROPRIATE FIRE ALARM SYSTEM INSTALLER.-VERIFY 9. KITCHEN EXHAUST FAN TO BE A MINIMUM OF 100 CFM-VERIFY 10. BATHROOM EXHAUST FAN TO BE A MINIMUM OF 50 CFM-VERIFY 11.FIREPLACE IN LOBBY TO BE REMOVED STAIR NOTES: EXISTING STAIRS TO REMAIN NEW CONSTRUCTION EXISTING TO REMAIN TO BE DONE: • CONTRACTOR TO INTALL C02 DETECTORS OUTSIDE EACH LIVING AREA • CONTRACTOR TO VERIFY BATHROOM EXHAUST COMPLIES WITH IRC • CONTRACTOR TO INSTALL 2O MINUTE DOORS AT RESIDENTIAL LOBBY • CONTRACTOR TO VERIFY CEILING HEIGHTS IN UNIT C BEDROOM • CONTRACTOR TO INSTALL ADA PATHWAY TO LAUNDRY ROOM • CONTRACTOR TO REMOVE CLOSETS IN UNIT E, CONVERT TO OPEN 1 BEDROOM • CONTRACTOR TO VERIFY KITCHEN EXHAUST COMPLIES WITH IRC • NO NEW WINDOWS HAVE BEEN INSTALLED • NO NEW WORK TO EXTERIOR WALLS • ALL INTERIOR DEMISING WALLS BETWEEN UNITS ARE CONFIRMED AT 1HR RATING • CONTRACTOR TO CONVERT UNIT A TO ADA UNIT PER FHA REQUIREMENTS A200 1 A2012 A201 1 A200 2 14' - 8"24' - 1 1/2"6" STEP 6" STEP E-FIREPLACE, NON OPERABLE 7' - 6"12' - 8" 12' - 0" 3' - 0"7' - 2"10' - 7"10' - 6"2' - 3" 6" STEP OPENING IN WALL 666 SF UNIT A 2 BED 1 BED 2 WIC LR/D MECH LAUNDRY 817 SF UNIT B 3 LAUNDRY EGRESS 2' - 0" EGRESS 2' - 0"4' - 0"3' - 0"2' - 6"6' - 3 3/4"5' - 5"DW2' - 0"1' - 3 3/4"261 SF LOBBY 4 449 SF UNIT D 5 SD SDSD SD EF EF EF POSSIBLE ADA UNIT, ADD RAMP ADD RAMP HERE TAKE THIS AND MAKE INTO ADA BATHROOM POSSIBLY, NEEDS TURNING RADIUS 1 HR WALL CONRTACTOR TO CONFIRM IF SD ARE ALSO C02 DETECTORS NEEDS 1" MORE OPEN, 28" CLEAR POSSIBLE DROPPED COUNTER WORKSPACE LOCATION 1 HOUR RATED WALL CONTRACTOR TO REPLACE DOORS WITH 20 MINUTE RATED DOORS PARKING SPOTS, CONTRACTOR TO DELINEATE AND INDICATE ADA SPOT ADD ADA WALKWAY TO LAUNDRY BR LR/DR BA ADA VAN STALL 5' - 0"10' - 0"ROAD ACCESS TO LOWER LEVELN Scale BNA Project number:PLOT DATE:103 91st Ave SE, Lake Stevens. WA 98258 4254780327 www.drift-ia.com STATUS: REVISION LOG REV #DATE DESCRIPTION DRAWN BY: SHEET NO. SHEET NAME NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION CLIENT NAMEPROJECT ADDRESSBUILDER NAMEBUILDER ADDRESSBUILDER CONTACTRegistered Architect in WA State DPS PERMIT NUMBER:FILE PATH:ORIGINAL DRAWING SIZE IS 36" X 24" DO NOT SCALE DRAWINGS FOR MEASUREMENTS 1/4" = 1'-0"9/18/2023 11:34:56 PMC:\Users\Jt\OneDrive - drift-ia.com\Projects\01 RESIDENTIAL\Bremerton Apartments\03 Revit\01 Work\D-IA-RA-BremertonApartments-SD-R0-V23.rvtFLOOR PLAN XXXXXX Author A100CLIENT NAMEXXXPERMITTWO LIGHTS PROPERTIESFLOOR PLAN GENERAL NOTES FLOOR PLAN KEYNOTES 1/4" = 1'-0"1 FIRST FLOOR EF EF DN?A200 1 A2012 A201 1 A200 2 LAUNDRY 10" STEP UP, VERIFY CONTRACTOR TO VERIFY CEILING HEIGHT AND PORTION OF CEILING THAT IS CODE COMPLIANT (7'-0") CLOSET CLOSET SD ALL WINDOWS EXISTING 1011 SF UNIT D 7 EF EF EF BR LR/DR BA MECH N ROOF ROOF ROOF 1. ALL DIMENSIONS ARE FROM FACE OF STUD OF NEW WALLS AND FINISHED SURFACE OF EXISTING WALLS UNLESS OTHERWISE NOTED. 2. TYPICAL INTERIOR PARTITION IS 2x4 STUD @ 16" O.C. WITH ONE LAYER OF 1/2" GYP BOARD ON EACH SIDE, EXCEPT WHERE NOTED ON PLANS. USE 2x6 STUDS AT PLUMBING WALLS. 3. 50 CFM EXHAUST FAN AT ALL NEW BATHROOMS 8. ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WITH BATTERY BACK-UP. WIRING SHALL BE PERMANENT AND WITHOUT A DISCONNECTING SWITCH OTHER THAN THOSE REQUIRED FOR OVERCURRENT PROTECTION. SMOKE ALARMS SHALL BE INTERCONNECTED AND COMPLY WITH HOUSEHOLD FIRE WARNING EQUIPMENT PROVISIONS OF NFPA 72. CONTRACTOR TO PULL FIRE ALARM PERMIT FOR APPROPRIATE FIRE ALARM SYSTEM INSTALLER.-VERIFY 9. KITCHEN EXHAUST FAN TO BE A MINIMUM OF 100 CFM-VERIFY 10. BATHROOM EXHAUST FAN TO BE A MINIMUM OF 50 CFM-VERIFY 11.FIREPLACE IN LOBBY TO BE REMOVED STAIR NOTES: EXISTING STAIRS TO REMAIN NEW CONSTRUCTION EXISTING TO REMAIN TO BE DONE: • CONTRACTOR TO INTALL C02 DETECTORS OUTSIDE EACH LIVING AREA • CONTRACTOR TO VERIFY BATHROOM EXHAUST COMPLIES WITH IRC • CONTRACTOR TO INSTALL 2O MINUTE DOORS AT RESIDENTIAL LOBBY • CONTRACTOR TO VERIFY CEILING HEIGHTS IN UNIT C BEDROOM • CONTRACTOR TO INSTALL ADA PATHWAY TO LAUNDRY ROOM • CONTRACTOR TO REMOVE CLOSETS IN UNIT E, CONVERT TO OPEN 1 BEDROOM • CONTRACTOR TO VERIFY KITCHEN EXHAUST COMPLIES WITH IRC • NO NEW WINDOWS HAVE BEEN INSTALLED • NO NEW WORK TO EXTERIOR WALLS • ALL INTERIOR DEMISING WALLS BETWEEN UNITS ARE CONFIRMED AT 1HR RATING • CONTRACTOR TO CONVERT UNIT A TO ADA UNIT PER FHA REQUIREMENTS Scale BNA Project number:PLOT DATE:103 91st Ave SE, Lake Stevens. WA 98258 4254780327 www.drift-ia.com STATUS: REVISION LOG REV #DATE DESCRIPTION DRAWN BY: SHEET NO. SHEET NAME NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION CLIENT NAMEPROJECT ADDRESSBUILDER NAMEBUILDER ADDRESSBUILDER CONTACTRegistered Architect in WA State DPS PERMIT NUMBER:FILE PATH:ORIGINAL DRAWING SIZE IS 36" X 24" DO NOT SCALE DRAWINGS FOR MEASUREMENTS 1/4" = 1'-0"9/18/2023 11:34:57 PMC:\Users\Jt\OneDrive - drift-ia.com\Projects\01 RESIDENTIAL\Bremerton Apartments\03 Revit\01 Work\D-IA-RA-BremertonApartments-SD-R0-V23.rvtLEVEL 2 PLAN XXXXXX Author A101CLIENT NAMEXXXPERMITTWO LIGHTS PROPERTIES1/4" = 1'-0"1 Second floor FLOOR PLAN GENERAL NOTES FLOOR PLAN KEYNOTES FIRST FLOOR 0' -0" FIRST FLOOR 0' -0" First floor 0' -0" First floor 0' -0" Second floor 9' -1" Second floor 9' -1" Basement floor -9' -11" Basement floor -9' -11" Third floor 20' -6" Third floor 20' -6" Scale BNA Project number:PLOT DATE:103 91st Ave SE, Lake Stevens. WA 98258 4254780327 www.drift-ia.com STATUS: REVISION LOG REV #DATE DESCRIPTION DRAWN BY: SHEET NO. SHEET NAME CLIENT NAMEPROJECT ADDRESSBUILDER NAMEBUILDER ADDRESSBUILDER CONTACTRegistered Architect in WA State DPS PERMIT NUMBER:FILE PATH:ORIGINAL DRAWING SIZE IS 36" X 24" DO NOT SCALE DRAWINGS FOR MEASUREMENTS 1/4" = 1'-0"9/18/2023 11:34:58 PMC:\Users\Jt\OneDrive - drift-ia.com\Projects\01 RESIDENTIAL\Bremerton Apartments\03 Revit\01 Work\D-IA-RA-BremertonApartments-SD-R0-V23.rvtBUILDING ELEVATION XXXXXX Author A200CLIENT NAMEXXXPERMITTWO LIGHTS PROPERTIESELEVATION GENERAL NOTES ELEVATION KEYNOTES 1/4" = 1'-0"1 FRONT ELEVATION 1/4" = 1'-0"2 LEFT ELEVATION FIRST FLOOR 0' -0" FIRST FLOOR 0' -0" Second floor 9' -1" Second floor 9' -1" Basement floor -9' -11" Basement floor -9' -11" Third floor 20' -6" Third floor 20' -6" Scale BNA Project number:PLOT DATE:103 91st Ave SE, Lake Stevens. WA 98258 4254780327 www.drift-ia.com STATUS: REVISION LOG REV #DATE DESCRIPTION DRAWN BY: SHEET NO. SHEET NAME NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION - NOT FOR CONSTRUCTION CLIENT NAMEPROJECT ADDRESSBUILDER NAMEBUILDER ADDRESSBUILDER CONTACTRegistered Architect in WA State DPS PERMIT NUMBER:FILE PATH:ORIGINAL DRAWING SIZE IS 36" X 24" DO NOT SCALE DRAWINGS FOR MEASUREMENTS 1/4" = 1'-0"9/18/2023 11:34:59 PMC:\Users\Jt\OneDrive - drift-ia.com\Projects\01 RESIDENTIAL\Bremerton Apartments\03 Revit\01 Work\D-IA-RA-BremertonApartments-SD-R0-V23.rvtBUILDING ELEVATION Copy 1 XXXXXX Author A201CLIENT NAMEXXXPERMITTWO LIGHTS PROPERTIES1/4" = 1'-0"1 REAR ELEVATION 1/4" = 1'-0"2 RIGHT ELEVATION