PRE-SUBMITTAL REPORT – BP24 00109
Kitsap Way Apartments
6323 Kitsap Way
May 29, 2024
For: Adam Putschoegl
partners@twolightsproperties.com
This report was prepared in response to the Presubmittal meeting that occurred on May
8, 2024. The information provided in this report is based off our review of the preliminary
project information you provided with your application. As proposed, the proposal is to
demolish the existing building, and construct an approximately 73,000-sf mixed-use
building at 6323 Kitsap Way, with 23 apartment units and 3 to 4 commercial units.
PLANNING DEPARTMENT – Staff Contact: Kelli Lambert, (360) 473-5245 or email
Kelli.Lambert@ci.bremerton.wa.us.
1. ZONING. The subject property is in the General Commercial (GC) zone. The intent of
the general commercial (GC) district is to provide locations for high intensity
commercial uses serving the entire community while preserving views, forested areas,
and buffering impacts to adjacent residential areas. The corridor accommodates
access to businesses by automobile while also creating a pedestrian-friendly, transit-
supporting corridor.
2. PROPOSED USE. Residential uses of all types, as well as a long list of commercial
uses, are permitted in the GC zone per BMC 20.62.020.
3. CRITICAL AREAS. The Kitsap County Parcel Viewer, Critical Areas layer shows the
site to be within a Category II Critical Aquifer Recharge Area (CARA). A hydrogeologic
assessment will be required with the building permit submittal, per BMC 20.14.450.
4. DEVELOPMENT STANDARDS. General Commercial zone development standards
are as follows:
(a) Maximum front yard setback: ten (10) feet. At least sixty-five (65) percent of
the building’s front facade must meet the maximum front yard setback. The code
allows for an increased setback at the Director’s discretion, if an analysis is
provided that shows the increase is the minimum necessary to facilitate a superior
site design. See BMC 20.62.060(1) for additional details.
(b) Minimum side yard setback: zero (0) except when adjacent to the low or
medium density residential zones where a ten (10) to twenty (20) foot visual screen
Pre-Submittal Report BP24 00109 Kitsap Way Apartments
Page 2 of 6
is required pursuant to BMC 20.50.050(b). Note: zoning to the west of this property
(across Lakehurst Drive) is Low Density Residential (R-10), therefore the visual
screen is required along the east property line.
(c) Minimum rear yard setback: zero (0) except when adjacent to the low and
medium density residential zones where a ten (10) to twenty (20) foot visual screen
is required pursuant to BMC 20.50.050(b);
(d) No residential density requirements; provided, that:
(i) Site design provides for internal circulation connections for both
pedestrians and vehicles between all portions of the site;
(ii) Landscaping and/or screening adjacent to residential zones shall be
provided per BMC 20.50.040(c).
(e) Maximum building coverage: fifty (50) percent unless increased per subsection
(b) of this section. In no case shall maximum lot coverage exceed seventy-five (75)
percent
(f) Maximum development coverage is seventy-five (75) percent unless increased
per subsection (b) of this section. In no case shall maximum lot coverage exceed
ninety-five (95) percent.
(g) Maximum building height: forty-five (45) feet, except that structures within
one hundred (100) feet of the low or medium density residential zones shall not
exceed thirty-five (35) feet in height. This property is within approximately 30 feet
of Low Density Residential-zone property (to the west). Note the guidance for
measuring the height of a structure, per BMC 20.44.070: ‘The height of a building
or structure shall be measured as the vertical distance from grade plane to the
average height of the highest roof surface.’
5. LANDSCAPING. Street trees are required along public and private streets, within the
front yard setback or public right of way, at a minimum of one per 25 linear feet, spaced
at a maximum 30 feet apart on center. Parking areas require interior landscaping at a
ratio of 10 square feet (sf) of landscaping per parking stall, with one tree for every 10
parking stalls. Each separate landscaped area must be a minimum of 50 sf and include
at least one tree, in combination with shrubs, groundcover, or other landscape
materials. See BMC 20.50 for landscaping regulations, including the requirements for
the Type I Visual Screening.
6. PARKING. Parking requirement is per BMC 20.48.060(i); number of spaces for multi
unit residential developments is based on number of bedrooms. Two-bedroom units
require 1.75 parking stalls per unit. The GC zone parking requirements include placing
parking to the rear or side of buildings, not allowing parking to occupy more than 50
percent of the site frontage facing the arterial street, and avoidance of placing parking
on street corners (BMC 20.62.080). Remaining development standards for parking
areas are per BMC 20.48.080.
7. MULTIFAMILY TAX EXEMPTION. Your Presubmittal documents asked specifically
about incentives (grants/subsidies) for affordable housing projects. This project is not
eligible for the Multifamily Tax Exemption (MFTE), as the project location is not within
the designated MFTE Target Area.
Pre-Submittal Report BP24 00109 Kitsap Way Apartments
Page 3 of 6
8. SEPA REVIEW: While fewer than 60 multifamily units on a single lot are exempt from
SEPA review per BMC 20.04.100(d)(2), grading of 1,000 cubic yards or more (cut + fill
= total grading) would require SEPA per BMC 20.04.100(d)(5). Grading amounts for
the excavation of the multifamily structure foundation can be deducted from total
grading subject to SEPA.
9. PERMITTING PROCESS. Site Plan Review (optional); Demolition permit; Site
development Permit; Building Permit.
BUILDING DEPARTMENT – Staff Contact: Staff Contact: Stuart Anderson (Building
Official), Roberto Medina, Jerry Harrington, and Roper Benitez -
roper.benitez@ci.bremerton.wa.us / (360) 473-5282.
1. This property was stop worked for remodeling without permits. Hearing order has given
this Owner until May 31st 2024 to comply with either a demolition permit or a permit
submittal for new development. As time is running out - to avoid fines and penalties,
please apply for a demolition permit for the stop worked property.
2. All work in the City of Bremerton shall adhere to the current adopted version 2021 of
the following codes as amended by the Washington State Building Code Council:
International Building Code (IBC)
International Residential Code (IRC)
International Fire Code (IFC)
International Mechanical Code (IMC)
Uniform Plumbing Code (UPC)
International Fuel Gas Code (IFGC)
WA State Barrier Free Code (IBC Chapter 11 and A117.1-2017)
WA State Energy Code (WSEC)
3. The City of Bremerton does not allow deferred submittals. M.E.P.'s will be required at
time of submittal. Electrical work is governed by the Washington State Department of
Labor and Industries and will need to be permitted and inspected by such agency. The
review of electrical drawings is limited to those affecting IBC requirements such as but
not limited to Chapter 10 - Means of Egress as well as certain aspects of the WA State
Energy Code.
4. IBC Table 429.2 EV Parking Requirements. 10% Total parking and 25% of Total is EV
Ready. IBC Section 1106 will have requirements for Accessible Parking.
5. Washington State Energy forms will be required at time of permit submittal. Please
include documentation along with plan submittals to demonstrate compliance with
Washington State Energy Codes (WSEC). You may find WSEC residential
compliance tools to assist you at WSU Energy Compliance website:
http://www.energy.wsu.edu/buildingefficiency/energycode.aspx and commercial
compliance tools at Evergreen Technology Consulting website:
www.waenergycodes.com or
https://www.energy.wsu.edu/buildingefficiency/energycode.aspx
Pre-Submittal Report BP24 00109 Kitsap Way Apartments
Page 4 of 6
6. Part of the 2021 Code is the requirements of Whole house Fan via ERV or HRV system
for each unit.
7. Trash Enclosure will need to be on a separate building permit and think about the
location while generating the site plan and civil plan.
8. Ensure no one is currently occupying the unpermitted units as the existing structure is
not approved for dwelling.
ENGINEERING DEPARTMENT – Staff Contact: Janelle Hitch, PE (360) 473-5285 or
Janelle.Hitch@ci.bremerton.wa.us.
1. The project will require larger water & sewer services. Please submit for a Utility
Availability Request. The application can be found online at the City of Bremerton
website at: https://www.bremertonwa.gov/DocumentCenter/View/7822/Utility-
Availability-Request-PDF?bidId=
A Water Meter Sizing worksheet is attached for your use.
2. Submit application for Fire Sprinkler Flow Request prior to final sprinkler design and
for available fire flow. The application can be found online at the City of Bremerton
website at: https://www.bremertonwa.gov/formcenter/fire-12/fire-sprinkler-flow-
request-107
3. Stormwater mitigation shall be provided if 2,000 square feet or more of new plus
replaced hard surfaces are proposed. Engineered stormwater site plan and report shall
be provided that is consistent with Bremerton Municipal Code (BMC) 15.04 and the
current Washington State Department of Ecology Stormwater Management Manual for
Western Washington.
4. Frontage improvements shall be designed and constructed per City of BMC 11.12
(Transportation Development Code).
a. Submit trip generations for both existing and proposed uses of project property. A
Traffic Impact Analysis (TIA) may be required pursuant to BMC 11.12.060.
b. Frontage improvements on Kitsap Way will include:
i. reducing the number of driveways to one, located away from the
intersection with Lakehurst Drive and following Standard Plan 3121 Type I.
ii. Adding curb and gutter, planter strip and sidewalk per Bremerton Standard
Plan 3007 along frontage.
Note that there is a City improvement project currently under design in this vicinity of
Kitsap Way. If the construction of the Kitsap Way project is scheduled in a timely
manner, the City may defer the completion of the frontage improvements and instead
have the applicant contribute funds for the frontage improvements.
c. Frontage improvements required on Lakehurst Drive may include:
i. Curb gutter and potentially sidewalk may be required along the property
frontage.
ii. The driveway is added it must follow Standard Plan 3122
5. A Right-of-Way Permit will be required for any work in the public right-of-way with
associated traffic control plan if applicable per Bremerton Municipal Code 11.02.060.
Pre-Submittal Report BP24 00109 Kitsap Way Apartments
Page 5 of 6
6. All applicable utility fees and assessments shall be paid pursuant to BMC 15.06.
CROSS CONNECTION CONTROL – Staff Contact: Brandon Hurst, (360) 473-5930 or
brandon.hurst@ci.bremerton.wa.us
1. A cross-connection (source of potential contamination to domestic water supply)
inspection is required prior to final inspection.
2. Cross Connection: All irrigation systems for commercial or industrial facilities shall
have separate service lines and separate meters. Residential and multifamily facilities
may install the irrigation system on the domestic supply. This requirement is in place
because the wastewater billing fees are tied to water consumption. All facilities with
irrigation systems shall have an approved double check valve assembly installed on
the service line within (2) two feet of the water meter to prove premises isolation (when
the backflow assembly is off, everything on the property will be without water). Systems
with chemical addition or auxiliary water supplies will be required to install an approved
reduced pressure backflow assembly within (2) feet of the water meter to provide
premises isolation. Approved assemblies are assemblies on the current Washington
State Department of Health approved assembly list.
3. Fireline: Backflow assemblies (DCDAs) for firelines shall be installed in the mechanical
room, less than 75 pipe feet away from where the water supply enters the property at
the right-of-way or easement. If the distance to the mechanical room is greater than
75 pipe feet, the backflow assembly shall be installed in an approved vault at the
property line or edge of easement where the water supply enters the property.
4. Cross Connection: All approved assemblies must be tested by a certified Washington
State backflow assembly tester at the time of installation, whenever serviced or moved,
and annually thereafter.
FIRE DEPARTMENT – Staff Contact: Michael Six, Bremerton Fire Marshal’s Office at
(360) 473-5386 or michael.six@ci.bremerton.wa.us
1. Fire Alarm and Fire Sprinkler will be required.
2. Fire Department access to all sides of the building within 150ft of access point.
3. Additional Fire Hydrants may be required based on Appendix B and C of the
International Fire Code.
4. Reference Contractors Guide on Bremerton Fire Marshal’s Website for turn radius
requirements.
5. Compliance w/ current IBC/IFC and City of Bremerton fire codes.
Note: The above comments are based on the project as it was proposed in the application materials
submitted to the city. The information provided in this report is not intended to be an exhaustive review
nor is it considered binding and/or a permit application vesting your proposal. The review information
above is subject to change should the referenced code and/or other applicable regulations this report
was based off are changed prior to a permit application being submitted for review.
Pre-Submittal Report BP24 00109 Kitsap Way Apartments
Page 6 of 6
If you have any further questions, please contact the individual staff members listed
above or the Department of Community Development main line at (360) 473-5275.