HomeMy WebLinkAbout03 0010Job Addr: Location: Parcel No: Applicant: I3RFEME:RT'10" PERF" 1=T GE:_- "TaR 286 4th Street, Bremerton, i4A 98337 -Phon'e': ( 360 ) 478-5275 FAX: ( 360 ) 478-5278 BUILDING PERMIT 2900 WHEATON WAY Permit No: 03-0010 ALBERTSON'S GROCERY STORE Status: ISSUED Applied: 01/07/2003 Issued: 01/13/2003 SIMPLEXGRINNELL LP 206-291-1400 Expires: 07/12/2003 9520 10TH AVE S #.100 SEATTLE WA 93108 Owner: ALBERTSON'S INC 208-395-6275 250 PARK CENTER BLVD BOISE IDAHO 83726 Contractor: SIMPLEXG RINNELL LP 206-291-14OLic #: SIMPLL*933BG Exp: 01-07-•2004 9520 10TH AVE S #100 SEATTLE WA 93103 Subcontr: Desc: INSTALLATION OF FIRE SUPPRESSION SYSTEM FOR HOOD IN KITCHEN *************************;KYF*3***iK***)K********* **%******************************k:*****.*�*:K***W. Valuation * Permit Fees: 33.25 Total Calculated Fee: x.41.36 2,500.00 * 'Plan Check Fees: 54.11 Additional Fees'...` .00 Other Fees: 4.50 Total Permit Fee' \ 141.86 This permit shall become null and void if the building or work authorized by this permit is not commenced within 180 day, from the date of such permit, or if this building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. NOTICE - It. is the responsibility of the permit holder, not the City of 8remertoi. "�uYlding Of�i ia1_to see to it that required inspections are made. The permit holder must notify thie Building Official when readyllflor inspection=:. Failure of the permit holder to notify the Building Official sof required ing_ ections may result 1 in the stoppage of the work until such time that the permit holder can substantiate "the building fficial that the concealed work meets or exceeds code requirements. Any demolition, testing, or nang2a`lrden shall be borne directly by the permit holder. Failure to substantiate code requirements wi11 ind4mnlfy the/eity against any and all responsibility or liability connected with the construction. ! I hereby certify that I have read and examined this permit and know the same o b <.h and COY' 1 provisions of laws and ordinances governing this type of work will be complie witther specified herei or not. The granting of a permit does not presume to give authority to \r\iolate or�cancel the provisions of any other state or local law regulating construction or the performance oi*..construction. / pate I certify that I am exempt from the requirements of the state contractor's registration law, under Section 3, Chapter 126, laws of 1967. Signature Date: Permit Cem ter, W --Approved By':_. Date:_ ____1 � _..—! I -S I..286 4th Street, Bremerton, WA 98337 'e. ( 360) 4.78-5275 FAX: ( 360) 478-5278 Building Permit No: 03-0010 Job Address: 2900 WHEATON WAY Status: ISSUED Location: ALBERTSON'S GROCERY STORE Issued: 01/13/2003 Assr Acct No: Expires: 07/12/200:3 R E. Q U I R E D I N S P E C T 1 0 N S Item: 02150 CROSS CONNECTION CONTROL Dept: CROSSCC Division: Item: 02000 FIRE SPRINKLERS/SUPPRESSION Dept: EIRE Division: �K*=K*Y:�:�*k�K�k.KIK*��=�K;*;K�K�-k7kxc**��f::YAK*�K�K�k��F::ic�I:�K�K�K�S:�*�Ic�Y•�K�k*;Y*�K*�=�k�K�K�K�c�k��K�i:�K*�K*xc�lc**�K*�:***�k��P:� TESTING: Must be recognized by the Washington Association of Building Officials SPECINSP: Must be registered with the State of WA ST OF WA: Stat; of WA Dept. of Labor and Industries 475-11.921 HEALTH: Bremerton/Kitsap Health District 475-S2:3S ALL INSPECTIONS PERFORMED BY THE CITY OF BREMERTON MUST BE SCHEDULED THROUGH THE PERMIT CENTER, ( 360) 478--5275. J �;;;Kx',>k�:%k%f:%K*�K%K*.'I,"k.%k:%�•'•�K��K`-Y.y,:y(-�r=*�*�'�K*aK%K=KYc**�c:/.�i:�:T>K*�K%K�:�c%K>Y��•;�k>Y-Yc�K�'.%K�k%K*=k�K*���k�'.**xc*�:�=0c h;yF�*'K =k�= Permit Holder's Signature: _._._ Date". s f '00���;^� ----------------��.���� BREMERTON PERMIT CENTER .»-•"" PERMIT CONDITIONS Permit No,: 03-0014.) Page: 1 Job Address: 2900 WHEATON WAY Applied: 01/07/2003 Assr Acct No: Approved: 01/13/2003 Location: ALBERTSON'S GROCERY STORE Issued: 01/13/2003 Applicant: SIMPLEXGRINNELL LP Owner: ALBERTSON'S INC Contractor: SIMPLEXGRINNELL LP Description: INSTALLATION OF FIRE SUPPRESSION SYSTEM FOR HOOD IN KITCHEN Conditions: 1. PRIOR TO PERFORMING ANY RENOVATION OR DEMOLITION WORK, PUGET SOUND CLEAN AIR AGENCY (CLEAN AIR AGENCY) AND WASHINGTON DEPARTMENT OF LABOR AND INDUSTRIES (L&I) REGULATIONS REQUIRE AN ASBESTOS SURVEY BE PERFORMED TO DETERMINE WHETHER THERE ARE ASBESTOS -CONTAINING MATERIALS IN THE WORK AREA OR STRUCTURE. THE ASBESTOS SURVEY MUST BE CONDUCTEDBY AN EPA CERTIFIED (AHERA) BUILDING INSPECTOR (EXCEPT RENOVATION OF OWNER -OCCUPIED SINGLE FAMILY RESIDENCES). FOR MORE INFORMATION, PLEASE CONTACT CLEAN AIR AGENCY THROUGH THEIR WEB SITE AT www.pscleanair.org OR BY PHONE AT 800--552--3565 OR 206-689-4058. THE L&I WEB SITE CAN BE FOUND AT www.lni.wa.gov/wisha/p,-ts/asbestos/asbeet-o-s-.ht-m.. 2. FIRE DEPT CONDITIONS OF APPROVAL: A) TEST REQUIRED AT COMPLETION. R) SY�-;TFM SHALL BE MONITORED BY FIRE ALARM SYST,,EM -- Permit Holder' Signatu.re.,_ _ ate �=� RECEIPT RECEIPF Number: 03000032 Amount: 87.75 01/13/03 10:10 Paymeol Net hod: CHECK Notation: DARRELL SACWAR !nit: PC ------------------------- Permit Not ------------------------------------- 03-0010 Type; FIRESPR FIRE SPRINKLER PERMI Site Address 2900 WHEATON WAY Location: ALBERTSON'S GROCERY STORE Total Fees; 141.86 This Paymen! 87.75 Total ALL QVI 141.86 Balance' .00 Account Code Description AmounL 16-322.1001 (2211) BUILDING PERMIT FEES 83.25 643-2012V (0236) ----------------------------------------------------------------- SFATE OF WA SURCHARGE 4.50 -CCC E3RaMaR-F-a ! RERBMI I T CERlTER 286 4th Street, Bremerton, WA 98337 • Phone: ( 360 ) 478-5,2175 FAX: ( 360 ) 478-5278 _ 0 BUILDING PERNU _ C'KJ Job Addr- a I D � Permit No: 03 0010 Location. ALBERTSON'S GROCERY STORE Status: PENDING Parcel No: Applied: 01/07/2003 Issued: Applicant: SIMPLEXGRINNELL. LP 206-291-1400 Expires: 9520 10TH AVE S #100 SEATTLE WA 98108 Owner: ALBERTSON'S INC 208-395-6275 250 PARK CENTER BLVD BOISE IDAHO 83726 Contractor: SI.MPLEXGRINNELL LP 206-291-1401.ic #: SIMPLL*988BG Exp: 01-07-2004 9520 10TH AVE S 4100 SEATTLE WA 98108 Subcontr: Desc: INSTALLATION OF FIRE SUPPRESSION SYSTEM Valuation * Permit Fees: 83.25 Total Calculated Fee: 141.86 2,500.00 * Plan Check Fees: 54.11 Additional Fees: .00 * Other Fees: -4.50 Total Permit Fee: 141.86 This p&rmit shall become null and void if the building or work authorized by this permit is not commenced within 180 days from the date of such permit, or if this, building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 clays. NOTICE -- It is the responsibility of the permit holder, not the City of Bremerton or Building official to see to it that required inspections are made. The permit holder must notify the Building official when ready for inspections. Failure of the permit holder to notify the Building Official. of required inspections may result in the stoppage of the work until ouch time that the permit holder can substantiate to the building official that the concealed work meets or exceeds code requirements. Any demolition, testingzzx urden shall be borne directly by the permit holder. Failure to substantiate code requireme swill indemnify the Ci ; against any and all responsibility or liability connected with the construct n. I hereby certify that I have read and examined this permit and know the Provisions of laws and ordinances governing this type of work will be c or not.. The granting of a permit does not presume to give authority to any other state or local law regulating construction or the performance Signature: Date: ne to be trFheyty.ecrflezKein erlied with w olate or caovislrf construct'o i or_,, `�� I certify that I am exempt from the requirements of the otate contractor's i istrati Section 3, Chapter 126, laws of 1967. Permit Center ---Approved By: _6�__'Lr Date: Date: X2003 BREMERTON___ VC, 0 03-0010 PERMIT CENTER Department of Community Development 286 4th Street * Bremerton WA'* 98337 (360) 478-5275' Fax (360) 478-5278 Building Permit Application APPLICANT: ❑ OWNER CONTRACTOR ErAUTHORIZED AGENT Site Address Tax Account Number: CONTRACTOR: s; ( OWNER or Authorized Agent: Address: Z() 4 A NEW DUPLEX p 5 City,State'zip fe « Dk Address: j License # & Expir. Date: Co o Z 12 City, State, Zip Contact Name: RESIDENTIAL ADDITION Phone #: ( ) Contact Phone #: (2d6) Z q /- lyylk' _t` %tv U vc Check the tvDe of aoolication for below .7 NEW SINGLE-FAMILY RESIDENCE d ❑ NEW DUPLEX ❑ ❑ NEW MANUFACTURED HOME ❑ ❑ RESIDENTIAL REMODEL ❑ ❑ RESIDENTIAL ADDITION ❑ ❑ RESIDENTIAL REPAIR ❑ JTV`"JAIL 07 70ol NEW COMMERCIAL ❑ COMMERCIAL REMODEL ❑ COMMERCIAL ADDITION ❑ COMMERCIAL REPAIR ❑ NEW MULTI -FAMILY ❑ TENANT IMPROVEMENT ❑ NEW GARA lENT NEW ACCESSORY BLDG NEW SIGN STRUCTURE DEMOLITION GRADING (Cubic yards: ) OTHER IS THIS PROPERTY WITHIN 200 FEET OF A SHORELINE? YES ❑ NO [✓]� Scope of Work Proposed: Square Footage: Dwelling: Garage: Decks: Valuation Plan Review Fee Permit Fee Surcharge Total Fees i zsoD - 5 II g3�5 iso Application for which no permit is issued within 180 days following the date of application shall expire by limitation, and plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the building official. The building official may extend the time for action by the applicant for a period not exceeding 180 days on request by the applicant showing the circumstances beyond the control of the applicant have prevented action from being taken. No applicant shall be extended more than once. In order to renew action on an application after expiration, the applicant shall resubmit plans and pay a new plan review fee. APPLICANT'S SIGNATURE:%,IA&DATE: 01Z�10? t jw 4' 1), A,. RECEIPT Ac le -!:>'.;if 'k* A :4Z -,Ic** V,** *** Numb+ r 03000019 Amount" 54, '11 .1 01./0 /03 16 01 Payment 11(i. -it -hod: CK Nota -i-. .on: SACKWAR CK snit: VW 10ermli.t. N.D: 0,3-0010 FIRESPR FIRE SPRINKLER PERMI !.-occ ation: ALeER,r'-sows GROCERY STORE Total Fees'. .1.41.., 86 541. 1 his Payflif.-mt Total ALL Pmts: 8 a la� ri c e, 01'.%5 t)ccount Code D (- s c. r J. pt -ion Amount 16-345,8300 (4 580) OUILD.MG PLAN CHECK' FEES 54.1.1 t jw GA5 VA Iv? r -T - i 25-35 3 -3 ryes o APPROVE®yo a rr, �zXzo" 3 yea l uZ 300 Cd "v O ue,t'j D ,aN ®� 2p03 --Jr Or) oi ao 1 Z4?420 41-4e.44"4a'4i ?9-337 SYSTEM DESIGN The R-102 and the PIRANHA systems use compatible agents and components, therefore, they may be used together for cooking appliance, hood, and duct protection. The primary ANSUL AUTOMAN Release can be either an R-102 or a PIRANHA ANSUL AUTOMAN Release and can actuate up to two additional R-102 or PIRANHA Regulated Actuators. In systems utilizing a 101 remote release, any combination of the maximum number of regulated actuators can be used. • Both systems must actuate simultaneously. • Each system must be designed and installed per its appropri- ate manual. • Adjacent appliances requiring protection must be protected with the same type of system, either R-102 or PIRANHA, unless the center -to -center spacing between the adjacent R-102 and PIRANHA nozzles is no less than 36 inches. • When appliances are protected with R-102 nozzles, the hood and connecting duct above those appliances cannot be pro- tected with PIRANHA nozzles. • Mixing systems in a common plenum is not allowed. The Ansul R-102 Restaurant Fire Suppression System may be used on a number of different types of restaurant cooking appli- ances and hood and duct configurations. The design information listed in this section deals with the limitations and parameters of this pre-engineered system. Those individuals responsible for the design of the R-102 system must be trained and hold a current Ansul certificate in an R-102 training program. One of the key elements for restaurant fire protection is a correct system design. This section is divided into ten sub -sections: Noz- zle Placement Requirements, Tank Quantity Requirements, Actu- ation and Expellant Gas Line Requirements, Distribution Piping Requirements, Detection System Requirements, Manual Pull Sta- tion Requirements, Mechanical Gas Valve Requirements, Electri- cal Gas Valve Requirements, Electrical Switch Requirements, and Pressure Switch Requirements. Each of these sections must be completed before attempting any installation. System design sketches should be made of all aspects of design for reference during installation. NOZZLE PLACEMENT REQUIREMENTS This section gives guidelines for nozzle type, positioning, and quantity for plenum, duct, and individual appliance protection. This section must be completed before determining tank quantity and piping requirements. Duct Protection All duct protection is UL approved without limitation of maximum duct length (unlimited length). This includes all varieties of duct- works both horizontal and vertical including ducts that run at angles to the horizontal and ducts with directional bends. The R-102 system uses several different duct nozzles depending on the size of duct being protected. 1. 1W Nozzle (Part No. 419336) — 1.5 Gallon and 3.0 Gallon Systems: The R-102 systems, both 1.5 gallon and 3.0 gallon, use the 1W nozzle (Part No. 419336) for duct protection of 27 in. (68.6 cm) perimeter or less or 8.5 in. (21.6 cm) diameter or less. The nozzle tip is stamped with 1 W, indicating that this is a one -flow nozzle and is to be counted as one flow number. SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-1 7-1-98 REV.3 — Single Nozzle (One Flow Number) Duct Protection: One 1W nozzle (Part No. 419336) will protect ducts with a maximum perimeter of 27 in. (68.6 cm) or a maximum diameter of 8.5 in. (21.6 cm). The nozzle must be installed 2-8 in. (5-20 cm) into the center of the duct opening and positioned as shown in Figure 1. 2-8 IN. (5 — 20 cm) FIGURE 1 000173 Single Nozzle (One Flow Number) Transition Protection: One 1W nozzle (Part No. 419336) will protect transitions where the perimeter of 27 in. (68.6 cm) or the diameter of 8.5 in. (21.6 cm) or less begins within that transition. The nozzle must be placed in the center of the transition open- ing where the maximum perimeter or diameter begins as shown in Figures 2 and 3. MODUI NOT M 27 IN. ( MC NO 8.5 FIGURE 2 000174 FIGURE 3 000175 SECTION IV — SYSTEM DESIGN ► UL EX. 3470 ULC CEx747 Page 4-2 7-1-98 REV.1 NOZZLE PLACEMENT REQUIREMENTS (Continued) Duct Protection (Continued) NOTICE A 2WH nozzle must be substituted for a 2W nozzle for any installation using Option 2 of the No 1.5 gallon system coverage (6 flow duct and 24 plenum protection only). 2.2W Nozzle (Part No. 419337): The R-102 System, uses the 2W nozzle (Part No. 419337) for duct protection of 75 in. (190.5 cm) perimeter or less, or 24 in. (61 cm) diameter or less. The nozzle tip is stamped with 2W, indicating that this is a two -flow nozzle and must be counted as two flow numbers. The 1W and 2W nozzles will protect the following: 3. Single Nozzle (2W) Duct Protection: One 2W nozzle will protect ducts with a maximum perimeter of 75 in. (190.5 cm) or a maximum diameter of 24 in. (61 cm). The nozzle must be installed 2-8 in. (5-20 cm) into the center of the duct opening and positioned as shown in Figure 4. 2-8 IN (5-20 FIGURE 4 000173 4. Single Nozzle (2W) Transition Protection: One 2W nozzle will protect transitions at the point where the perimeter of 75. in. (190.5 cm) or the diameter of 24 in. (61 cm) or less begins within that transition. The nozzle must be placed in the center of the transition opening where the maximum perimeter or diameter begins as shown in Figures 5 and 6. MODU NOT M 75. IN. FIGURE 5 000174 FIGURE 6 000175 5. Dual -Nozzle Duct Protection: Two 2W nozzles will protect ducts with a maximum perimeter of 150 in. (381 cm) or a maximum diameter of 48 in. (122 cm). The nozzles must be installed 2-8 in. (5-20 cm) into the duct opening and positioned as in Figure 7. LENGTH CT "H FIGURE 7 000176 NOTICE In installations where a UL listed damper assembly is employed, the duct nozzle can be installed beyond the 8 in. (20 cm) maximum, to a point just beyond the damper assembly that will not interfere with the damper. Exceeding the maximum of 8 in. (20 cm) in this way will not void the UL listing of the system. SECTION IV — SYSTEM DESIGN ► UL EX. 3470 ULC CEx747 Page 4-8 7-1-98 REV.3 NOZZLE PLACEMENT REQUIREMENTS (Continued) Plenum Protection (Continued) 4 IN. (10 c NOZZLE TIP � MUST BE WITHIN THIS AREA 12 IN. (30 cm) MAXIMUM 8 IN. (20 cm) MAXIMUM FIGURE 26 ►1 N NOZZLE — PART NO.419335 — SINGLE BANK PROTECTION One 1 N nozzle will protect 8 linear feet (2.4 m) of single filter bank plenum. The nozzle(s) must be mounted in the plenum, 2 to 4 in. (5 to 10 cm) from the face of the filter, centered between the filter height dimension, and aimed down the length. The filter height must ►not exceed 20 in. (51 cm). See Figure 27a. FIGURE 27a ►1 N NOZZLE — PART NO. 419335 — "V" BANK PROTECTION Two IN nozzles will protect 8 linear feet (2.4 m) of "V" bank plenum. The nozzles must be mounted in the plenum, 2 to 4 in. (5 to 10 cm) from the face of the filter, centered between the filter height dimen- sion, and aimed down the length. The filter height must not ►exceed 20 in. (51 cm). See Figure 27b. 2 ► FIGURE 27b Exception: When the plenum chamber contains filters that do not exceed 10 in. (25.4 cm) in height and the 1N nozzle can be installed at the intersecting center lines of both filter banks and not exceed the 2-4 in. (5 to 10 cm) distance from either filters, a single ►1 N nozzle can be used. See Figure 27c. 2 -41N.2 -41N. (5 —10 cm) (5 — 10 cm) 1N NOZZLE 10 IN. (25.4 cm) MAXIMUM ► FIGURE 27c ODOM NOTICE If 1 N nozzle coverage does not exceed 7 linear ft. (2.1 m), the nozzle can be mounted 2 to 6 in. (5-15 cm) from the face of the filter. SECTION IV — SYSTEM DESIGN ► UL EX. 3470 ULC CEx747 Page 4-11 7-1-98 REV.5 ► NOZZLE PLACEMENT REQUIREMENTS (Continued) 34 IN. (86 cm) MAXIMUM DIAGONAL Fryer — Single Nozzle Protection (Continued) CENTER OF HAZARD AREA Maximum Area Dimensions — Single Nozzle Fryer Protection (Continued) Max. Size Max. Size Overall Type of Nozzle Height Frypot Only With Dripboard Nozzle Above Top of Fryer HEIGHT 19.5 in. x 19 in. 19.5 in. x 25 3/8 in. 290 13 in. to 16 in. (50 cm x 48 cm) (50 cm x 65 cm) (33 to 41 cm) 19.5 in. x 19 in. 19.5 in. x 25 3/8 in. 3N See Figure (50 cm x 48 cm) (50 cm x 65 cm) 34 18 in. x 18 in. 18 in. x 27 5/8 in. 3N 25 in. to 35 in. (46 cm x 46 cm) (46 cm x 70 cm) (64 cm to 89 cm) I I I I I I I 1 , I FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD 290 NOZZLE TIP POSITIONED OVER THE MIDPOINT OF THE HAZARD AREA t 3 IN. (7.6 cm) FROM THE MIDPOINT ALONG THE LONGEST SIDE OF THE HAZARD AND t 1 IN. (2.5 cm) FROM THE MIDPOINT ALONG THE SHORTEST SIDE OF THE HAZARD AND AIMED AT THE MIDPOINT OF THE COOKING AREA. FIGURE 33 002288 J FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD 3N NOZZLE TIP POSITIONED ANYWHERE ALONG OR WITHIN PERIMETER OF COOK- ING SURFACE AND AIMED TO THE CENTER OF THE COOKING AREA. FIGURE 34 002297 Nozzle Location See Figure 33 See Figure 34 See Figure 35 TOP OF FRYER FRO j ' RIGHT-TO-LEFT �8 °00010 CENTERLINE FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD NOTE: 3N NOZZLE TIP MUST BE LOCATED WITHIN THE PERIMETER OF THE SURFACE AREA AND FORWARD OF THE RIGHT-TO-LEFT CENTERLINE. FIGURE 35 34 IN. (86 cm) MAXIMUM DIAGONAL DISTANCE BETWEEN NOZZLE AND CENTER OF HAZARD AREA 21 in (53 Cm) MINIMUM VERTICAL I NOZZLE HEIGHT J FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD 3N NOZZLE TIP POSITIONED ANYWHERE ALONG OR WITHIN PERIMETER OF COOK- ING SURFACE AND AIMED TO THE CENTER OF THE COOKING AREA. FIGURE 34 002297 Nozzle Location See Figure 33 See Figure 34 See Figure 35 TOP OF FRYER FRO j ' RIGHT-TO-LEFT �8 °00010 CENTERLINE FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD NOTE: 3N NOZZLE TIP MUST BE LOCATED WITHIN THE PERIMETER OF THE SURFACE AREA AND FORWARD OF THE RIGHT-TO-LEFT CENTERLINE. FIGURE 35 SECTION IV — SYSTEM DESIGN ► UL EX. 3470 ULC CEx747 Page 4-34 7-1-98 REV.4 TANK AND CARTRIDGE REQUIREMENTS Once the hazard analysis is completed and the total nozzle flow numbers are established, the quantity and size of agent tanks and cartridges needed to supply the nozzles with the proper volumes of agent at the proper flow rates can be determined. For cartridges used in the regulated release mechanism, flow capacities, tank quantities and sizes, and regulated release cartridge options are given in the table below. Total Quantity and Regulated Release Flow Size of Cartridge Options Numbers* Tanks Nitrogen Carbon Dioxide 1— 5 (1) 1.5 Gallon LT -20-R (7032) 101-10 (15850) 6-11 (1) 3.0 Gallon LT 30-R (5373) 101-20 (17492) 11 —16 (1) 1.5 Gallon Double (73022) 101-30 (15851) (1) 3.0 Gallon 16-22 (2) 3.0 Gallon Double (73022) 101-30 (15851)** ,-When one or more regulated actuators are used, the following tank and cartridge combinations apply for each regulated actuator: Regulated Actuator Tank(s) (1) 1.5 Gallon (1) 3.0 Gallon (1) 1.5 Gallon and (1) 3.0 Gallon ►(2) 3.0 Gallon Regulated Actuator Cartridge LT -20-R or 101-10 LT30-R or 101-20 LT -A-101-30 or 101-30** LT -A-101-30 or 101-30** For exceptions to maximum flow numbers, see Distribution Piping Requirements for 1.5 gal- lon and 3.0 gallon systems in this Section. The 101-30 cartndge Part No. 15851, can not be used when (2) two 3.0 gallon tanks are man- ifokied together.) For higher total flow numbers (23 to 110), multiple cartridges and regulated actuators are required as shown in the System Selection Guide in Section IX — Appendix. ACTUATION GAS LINE WITH AN LT -20-R, LT -30-R, 101-10 OR 101-20 CARTRIDGE MAXIMUM LENGTH OF 20 Fr. (6 m), MAXIMUM NO. OF FITTINGS 9 "ANSUL AUTOMAN" REGULATED RELEASE ASSEMBLY ACTUATION AND EXPELLANT GAS LINE REQUIREMENTS This section contains the guidelines for installing the actuation and expellant gas lines between the regulated release mechanism reg- ulator, each regulated actuator regulator, and each agent tank. These limitations should be considered when selecting the com- ponent mounting locations. P. Actuation Gas Line — 6 to 8* Tanks Maximum i' 8 Tank maximum reflects the utilization of 3 tank regulated actuators. 1. Use only 1/4 in. Schedule 40 black iron, hot -dipped galva- nized, chrome -plated, or stainless steel pipe and fittings. 2. The actuation gas line piping is installed from the regulated release mechanism to each regulated actuator connected within the system. The total length of the actuation gas line from the regulated release assembly to the regulated actuator assembly(ies) must not exceed 20 ft. (6 m) when using an LT20-R (Part No. 7032), an LT30-R nitrogen cartridge (Part No. 5373), or a 101-10 (Part No. 15850) or a 101-20 (Part No. ► 17492) carbon dioxide cartridge. See Figure 73. REGULATED ACTUATOR ASSEMBLY EXPELLANT GAS LINES NOT INCLUDED IN ACTUATION / GAS LINE LENGTH TOTALS ACTUATOR REGULATED ACTUATOR ASSEMBLY FIGURE 73 00=5 DISTRIBUTION PIPING REQUIREMENTS (Continued) Supply and Branch Line Identification The R-102 distribution piping network is broken down into four specific pipe runs: the Supply Line, the Duct Branch Line, the Plenum Branch Line, and the Appliance Branch Line. See ► Figure 79. DUCT BRANCH LINE SUPPLY \. �• LINE PLENUM APPLIANCE BRANCH LINE BRANCH LINE NOTE: THIS IS A CONCEPTUAL DRAWING ONLY. THIS IS NOT AN ACTUAL INSTALLATION. ' FIGURE 79 000779 NOTE: THESE ARE EXAMPLES ONLY. OTHER CONFIGURATIONS CAN BE DESIGNED. END OF SUPPLY LINE SECTION IV — SYSTEM DESIGN ► UL EX. 3470 ULC CEx747 Page 4-37 7-1-98 REV.2 END OF SUPPLY LINE l _..D OF SUPPLY LINE END OF SUPPLY LINE ire SUPPLY (NOZZLES FOR LINE TEE PLENUM PROTECTION) END OF SUPPLY LINE BRANCH LINE CANNOT START AHEAD OF A SUPPLY LINE TEE FIGURE 80 000780 (NOZZLES FOR PLENUM PROTECTION) BRANCH LINE CANNOT START AHEAD OF A SUPPLY LINE TEE FIGURE 80 000780 SECTION IV — SYSTEM DESIGN ► UL EX. 3470 ULC CEx747 Page 4-38 7-1-98 REV.3 DISTRIBUTION PIPING REQUIREMENTS (Continued) Supply and Branch Line Identification (Continued) SUPPLY LINE The Supply Line is defined as the length of pipe which runs from the agent tank outlet to the last branch line (whether a duct, appli- ance, or plenum branch line). This includes all supply line fittings except for the tees or elbows leading to the branch lines. See ► Figures 79 and 80. NOTICE Branch lines cannot start ahead of a supply line tee. DUCT BRANCH LINE The Duct Branch Line is defined as the length of pipe which runs from the supply line to the duct nozzle(s). This includes all branch line fittings as well as the tee or elbow used to start the branch line. ► See Figures 79 and 81. DUCT BRANCH LINE (ELBOW INCLUDED) DUCT BRANCH LINE (TEE INCLUDED) S ' .4 v DUCT BRANCH LINE ��• (TEES INCLUDED) C-' 1 r' i FIGURE 81 000781 PLENUM BRANCH LINE The Plenum Branch Line is defined as the length of pipe which runs from the supply line to the plenum nozzle(s). This includes all branch line fittings as well as the tee or elbow used to start the ► branch line. See Figures 79 and 82. .'fes j PLENUM BRANCH LINE . -C'\•, I (TEE INCLUDED) 1 1 PLENUM BRANCH LINE (TEE INCLUDED) FIGURE 82 000782 APPLIANCE BRANCH LINE The Appliance Branch Line is defined as the length of pipe which runs from the supply line to the appliance nozzle(s). This includes all branch line fittings as well as the tee or elbow used to start the branch line. See Figures 79 and 83. i 1 I APPLIANCE BRANCH LINES (TEES INCLUDED) FIGURE 83 0007M DISTRIBUTION PIPING REQUIREMENTS (Continued) Distribution Piping Requirements — 3.0 Gallon System 1. The maximum length between the start of the first branch line and the start of the last branch line must not exceed 24 ft. (7.3 m). When the supply line is split, the combined total of both legs of the supply line (from the start of the first branch line to the start of the last branch line) must not exceed 24 ft. ► (7.3 m). See Figure 88. 2. The total length of all branch lines must not exceed 36 ft. ► (10.9 m). See Figure 88. 3. Use a 3/8 in. union to connect the tank adaptor to the 3/8 in. supply line. 4. A maximum of two nozzles are allowed per duct branch line. 5. The requirements of the following table must not be exceeded: SECTION IV — SYSTEM DESIGN ► UL EX. 3470 ULC CEx747 Page 4-41 7-1-98 REV.1 SUPPLY \ , TEE ` \v OD0266 COMBINED LENGTH OF BOTH LEGS OF SUPPLY LINE MUST NOT 3 BRANCH LINES EXCEED 24 FT. (7.3 m) IN NOZZLE /\ 2W NOZZLE 1N NOZZLE 1� 230 NOZZLE / O 245 NOZZLE 1/2N NOZZLE (BRANCH LINE IN BOLD) COMBINED LENGTH MUST 00c NOT EXCEED 36 FT. (10.9 m) ' FIGURE 88 Duct Plenum Appliance Requirements Supply Line Branch Line Branch Line Branch Line Pipe Size 3/8 in. 3/8 in. 3/8 in. 3/8 in. Maximum Length 40 ft. 8 ft. 4 ft. 12 ft. (12.2 m) (2.4 m) (1.2 m) (3.7 m) Maximum Rise 6 ft. 4 ft. 2 ft. 2 ft. (1.8 m) (1.2 m) (.6 m) (.6 m) Maximum 90° 9 4 4 6 Elbows Maximum Tees 1 2 2 4 Maximum Flow 11* 4 2 4 Numbers 'Exceptions: 1. Twelve (12) flow numbers are allowed in any one tank not containing two -flow appliance nozzles, and/or, a IN nozzle for wok or griddle protection, and/or, a 1F nozzle for range protection, and/or, a 3N nozzle for fryer protection. 2. Twelve (12) flow numbers are allowed with any one tank using only two -flow appliance nozzles. 3. Twelve (12) flow numbers are allowed with any one tank using only three -flow appliance nozzles. Special Instructions: 1. Twelve (12) flow numbers are allowed when four (4) Dean Industries GTI Gas Fryers are protected at low proximity as shown in Figure 101 on Page 4-52. The discharge piping must be as shown in Figure 102 on Page 4-52. 2 For certain McDonald's applications, 11.5 flow numbers are allowed when using a combination of one (1) 2W duct nozzle, one (1) 1/2N electrostatic precipitator nozzle, one (1) 1 N plenum nozzle, and four (4) two -flow appliance nozzles. Contact Ansul Applications Engineering Department for additional information DETECTION SYSTEM REQUIREMENTS Once the fire suppression system design has been determined, a detection system design must be completed. This section contains guidelines and limitations for detection system installation. Detector Identification The two types of detectors are distinguished from each other by their location in the detection system. 1. The Terminal Detector (Part No. 56838, 15375, or 417368) is the last in a series of detectors, or the only detector used in a single -detector system. This detector is thus named because it is at the point at which the wire rope ends, or "terminates" 2. A Series Detector (Part No. 56837, 15373, or 417369) is any detector located in-line between the regulated release mech- anism and the terminal detector. Detector/Pulley Elbow Quantity The quantity of detectors used in the system will vary depending on the style of detector used. 1. Conduit runs, pulley elbows, and number of detectors per sys- tem must be within the approved system guidelines. The fol- lowing requirements must not be exceeded: Maximum Maximum Maximum Number of Number of Length of 1/2 Detectors Elbows in. Conduit per System per System per System Clip on Style 12 18 125 ft. (38.1 m) Detector Hinge Style 5 8 103 ft. (31.3 m) Detector Scissors Style 15 20 150 ft. (45.7 m) Detector 2. If hinge style detectors are mixed in a system with either clip - on or scissor style, 4 series and 1 terminal is the maximum number allowed. If clip -on style are mixed with scissor style, the maximum allowed is 11 series and 1 terminal. NOTICE When using the "clip -on" style detector, the ter- minal detector may use the "hinged" style mounting bracket with the "clip -on" style linkage. This is only allowed with the terminal detector. When using this option, the total number of "clip - on" style detectors (11 series and 1 terminal) is still allowed. 3. If hinge style detectors are mixed in a system with either clip - on or scissor style, the maximum length of wire rope must not exceed 103 ft. (31.4 m) and the maximum number of pulley elbows must not exceed 8. If clip -on style are mixed with scis- sor style, the maximum length of wire rope must not exceed 125 ft. (3.81 m) and the maximum number of pulley elbows must not exceed 18. 4. If the hazard requires more than 15 detectors, up to five 101 Remote Releases (Part No. 12029) can be used for system actuation. Each 101 remote release allows the use of a maxi- mum of 15 "scissor" style detectors (14 series and 1 terminal) for a total of 75 detectors if needed. SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-45 7-1-98 Detector Placement Requirements EXHAUST DUCTS Each exhaust duct must have at least one detector installed in the duct entrance, located in the airstream of the cooking vapors, or at ► a maximum of 20 ft. (6.1 m) into the duct opening. See Figure 93. FIGURE 93 000271 NOTICE When gas appliances are used and the flue gases from the burner are exhausted into the duct, the detector must be kept out of the air stream of these exhaust gases. These gases can be very hot and could actuate the system unnecessarily. Duct openings that are long and narrow or large enough to require multiple duct nozzles may require additional detectors. ELECTROSTATIC PRECIPITATOR If an electrostatic precipitator is located at or near the base of the exhaust duct, it is necessary to locate a detector below the pre- cipitator, at the base of the duct, and also locate one in the duct, ► just above the precipitator. See Figure 94. When installing the detector bracket and system conduit, make certain they do not interfere with the operation of the precipitator. 1-- FIGURE 94 000266 SECTION IV — SYSTEM DESIGN ► UL EX. 3470 ULC CEx747 Page 4-46 7-1-98 DETECTOR SYSTEM REQUIREMENTS (Continued) Detector Replacement Requirements (Continued) COOKING APPLIANCES If the cooking appliance is located under an exhaust duct where a detector has been mounted, it is normally not necessary to utilize another detector for that cooking appliance, provided the detector ► is not more than 12 in. (30 cm) into the duct. See Figure 95. APPLIANCE APPLIANCE APPLIANCE APPLIANCE REQUIRES COVERED BY COVERED BY REQUIRES SEPARATE DETECTOR DETECTOR SEPARATE DETECTOR UNDER DUCT UNDER DUCT DETECTOR K STYLE ML STYLE 415742 500 °F (260 °C) ONLY FIGURE 95 000269 Detectors used for cooking appliances must be located above the surface and within the perimeter of the cooking appliance. They must be positioned toward the exhaust duct side of the appliance and high enough to prevent accidental actuation of the system. The cooking appliance detectors must be located in the air stream of the cooking fumes for quick fire detection. It is normally neces- sary to use one detector per area of single nozzle coverage, even though more than one appliance may be covered with a single nozzle. Detection Line Requirements CONDUIT Rigid conduit, 1/2 inch Schedule 40 galvanized pipe, or 1/2 inch EMT thin-wall conduit may be used. Standard steel conduit fittings (compression type are recommended) must be employed to prop- erly install the detection system. All conduit or pipe must be firmly supported. When using pipe, make certain that all ends are care- fully reamed, deburred and blown clear of chips and scale before assembly. NOTICE The conduit offset can be used at the top or bot- tom of the regulated release to change direction of the conduit. The conduit offset cannot be used with pulley tees. All other changes in direc- tion must be made by using Ansul approved pul- ley elbows, Part No. 423254 or 415670. See Figure 96. FIGURE 96 000270 Fusible Link Selection When possible, temperature readings should be taken at each detector location to determine correct fusible link temperature rat- ing. Temperature can be recorded using either a maximum regis- tering thermometer, Part No. 15240, temperature tape or any other accurate thermometer. O @T::2D ."gUL. Fusible Link Rating Temperature Does Part No. TEMPERATURE RATING O10N� STAMPED ON FUSIBLE [� LINK BODY 0 212 °F (100 °C) 000170 000171 K STYLE ML STYLE 415742 500 °F (260 °C) ONLY FIGURE 97 Select correct UL Listed fusible link(s) for installation in detector(s) according to the temperature condition chart below: Temperature To Be Used Where Fusible Link Rating Temperature Does Part No. (See Figure 79) Not Exceed 415739 165 °F (74 °C) 100 °F (38 °C) 415740 212 °F (100 °C) 150 °F (66 °C) 415741 280 °F (138 °C) 225 °F (107 °C) 415742 360 °F (182 °C) 290 °F (143 °C) 415743 450 °F (232 °C) 360 °F (182 °C) 56816 500 °F (260 °C) 400 °F (204 °C) MANUAL PULL STATION REQUIREMENTS A remote manual pull station allows the R-102 system to be man- ually operated at some point distant from the regulated release assembly. The pull station should be installed at a maximum height of 60 in. (152 cm) and located in the path of exit. The pull station is the only source of manual actuation of the regulated release assembly. Two styles of remote pull stations are available: metal stamped and plastic molded. The total length of the cable used for each manual pull station with- in a system must not exceed 150 ft. (46 m). The maximum number of pulley elbows that may be used per sys- tem is 20. One pulley tee, Part No. 15342, is allowed per system. Exception: When using a pulley tee, Part No. 15342, in the pull station line, the maximum length of wire rope to each pull station must not exceed 125 ft. (38 m) and the maximum number of elbows must not exceed 18. Metal Stamped Style — Part No. 4835 or 54011 Parts that may be used for installation of a metal stamped remote manual pull station are: Description Part No. Remote Manual Pull Station Assembly* 54011 Remote Manual Pull Station Assembly 4835 P- Pulley Elbow 423250 Pulley Elbow 415670 Pulley Tee** 15342 'Assembly includes parts listed below: 415256 1/16' Stainless Steel Cable 50 ft. (15 m) 15821 Oval Press -To -Crimp Sleeves 4596 Glass Break Rod (1) 4834 " Designed for 32 T to 130 IF (0 °C to 54 °C) temperature areas. Utilized when two remote manual pull stations are being connected to one regulated release assembly. Plastic Molded Style — Part No. 415255 55598 Parts that may be used for installation of a plastic molded remote manual pull station are: 55604 Description Part No. Remote Manual Pull Station Assembly 415255 Trim Ring Shipping Assembly (25) 415256 Replacement Seal Shipping Assembly (25) 415317 1/16" Stainless Steel Cable 500 ft. (152 cm) 79653 Oval Press -To -Crimp Sleeves 4596 Pulley Elbow 45771 Pulley Tee 15342 MECHANICAL GAS VALVE REQUIREMENTS An Ansul or Ansul approved mechanical gas shut-off valve system can be attached to the R-102 system. The system works both mechanically and pneumatically by use of an air cylinder located inside the regulated release assembly. Upon actuation of the fire suppression system, a pneumatically -operated air cylinder assem- bly will mechanically close the gas shut-off valve. The total length of the cable for the mechanical gas valve must not exceed 150 ft. (46 m). The maximum number of pulley elbows that may be used is 20. One pulley tee (Part No. 15342) is allowed per system. SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-47 7-1-98 Exception: When using a pulley tee, Part No. 15342, the maxi- mum length of wire rope to each gas valve must not exceed 125 ft. (38 m) and the maximum number of elbows must not exceed 18. Parts that may be used for installation of a Mechanical Gas Shut- off Valve are: Description Part No. Gas Valve/Actuator 3/4 in. Assembly (Ansul)* 55598 Gas Valve/Actuator 1 in. Assembly (Ansul)* 55601 Gas Valve/Actuator 1 1/4 in. Assembly (Ansul)* 55604 Gas Valve/Actuator 1 1/2 in. Assembly (Ansul)* 55607 Gas Valve/Actuator 2 in. Assembly (Ansul)* 55610 Gas Valve/Actuator 2 1/2 in. Assembly (ASCO)* 25937 Gas Valve/Actuator 3 in. Assembly (ASCO)* 25938 ► Pulley Elbow** 423250 Pulley Elbow** 415670 Pulley Tee*** 15342 1/16" Stainless Steel Cable 15821 or 50 ft. (15 m) or 500 ft. (152 m) roll 79653 Oval Press -To -Crimp Sleeve 4596 Stop Sleeve (2) 26317 Assembly includes parts listed below: Approved for 700'F (371 °C) temperature areas Used with two (2) ANSUL AUTOMAN releases to operate one (1) mechanical gas valve. Air Cylinder Assembly 15733 Air Cylinder 15521 Tubing Assembly 15529 Copper Tubing, 1/8 in. 15525 Male Elbow 15523 Male Connector 15522 Machine Screw (2) 15421 Hex Nut (2) 15527 Lockwasher(2) 4141 Visual Inspection Seal (2) 197 All valves above are UL listed and approved. They may be mount- ed in any position. Pipe threads are type NPT. Ambient operating temperature range of all valves is 32 OF to 120 OF (0 °C to 49 °C). The valves are not weatherproof and must be located indoors in areas approved by the "authority having jurisdiction" ELECTRICAL GAS VALVE REQUIREMENTS A UL Listed electrically -operated gas shut-off valve can be attached to the R-102 system to provide an electrical means of shutting off the gas line at a predetermined point. If an electric gas shut-off valve is used in the system it must be attached with both an electric (snap -action) switch and a manual reset relay. For more information on the types of electric (snap -action) switches, refer to P- the Electrical Switch, Field Installation section. The manual reset relay is reviewed in this section. All electrical connections should be performed by a QUALIFIED ELECTRICIAN and in accordance with authority having jurisdiction. The following is a brief explanation of how the R-102 system oper- ates with an Electric Gas Shut-off Valve attached: With the regulated release cocked in the ready condition, the nor- mally closed contacts in the snap -action switch allow current to flow to the manual reset relay. With the relay coil energized, nor- mally open contacts in the reset relay close, allowing the solenoid in the gas valve to be energized. �a� ��� UUUUUUUUIMUUU UUUUUUU//IT UUUiUUiai llllllll/lllll/lllllll /������ %111///l/ll iaUUU�uU IUUUUUUUUUUIIUI ''''�'�'►uUu' ''''''�'' rIJJJ!*W$)lll� ,row \JDJ Fire Supression systems Equipment Supplied By Fire& ell/ Security gF�EMER A����Nr 9 �g 13 .e f a 4 a 0 a 0 0 x z 0 rn a w z a <� APPROM )W. G DRAM aTU PNdECr WLMM3 c SUP -01