HomeMy WebLinkAbout98 0715
."
BREMERTON PERMXT CENTER
.286 4th Street, Brsmerton, WA 98337
Phone:: (360) 478-5275 FAX:: (360) 478-5278
BUILDING PERMIT
Job Addr: 2601 CHERRY AVE
Location: 2601 CHERRY AVE
Parcel No:
Applicant: MACDONALD MILLER CO 206-768-4288
7717 DETROIT AVE SW SEATTLE, WA 98106
Permit No: 98-0715
status: ISSUED
Applied: 11/17/1998
Issued: 11/23/1998
Expires: OS/22/1999
Owner: BRIOGEVIEW INVESTDRS 360-373-0453
2601 EAST CHERRY BREMERTONu WA 98310
Contractor: MACDONALD MILLER CO 206-768-428Lic I: MACDOM*24BJ9 Exp: 08-01-1999
7717 DETROIT AVE SW SEATTLEu WA 98106
Subcontr:
CeBe: REPLACE EXISTING COOLING TOWER WITH SAME
**H****************M"**.***********.********HH*********HH******M********************...******
Valuation * Permit Fees: 25.00 Total Calculated Fee: 30.53
.00 * Plan Check Fees: 5.53 Additional Fees: .00
* other Fees: .00 Total Permit Fee: 30.53
*MM****M**************..*********************************************************************
MECHANICAL/PLUMBING FIXTURES--
*********************************************************************************************
This permit shall become null and void if the building or work authorized by this permit is not commenced within
180 days from the date of such permit, or if this building or work authorized by such permit is suspended or
abandoned at any time after the work is commenced for a period of 180 days.
NOTICE - It is the responsibility of the permit holder, not the City of Bremerton or Building Official to see
to it that required inspections are made. The permit holder must notify the Building Official when ready for
inspections. Failure of the permit holder to notify the Building Official of required inspections may result
in the stoppage of the work until such time that the permit holder can substantiate to the building official
that the concealed work meets or exceeds code requirements. Any demolition, testing, or financial burden shall
be borne directly by the permit holder. Failure to substantiate code requirements will indemnify the City
against any and all responsibility or liability connected with the construction.
I hereby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of laws and ordinances governing this type of work will be complied with whether specified herein
or not. The granting of a permit does not presume to"give authority to violate or cancel the provisions of
any other state or local law regulating construction or the performance of construction.
S i gnat ure: ___________________d.d._____________________________
Date:
I certify that I am exempt from the requirements of the state contractor's registration law, under
Section 3~.cb.a ter 1~ 1967. ~
' ,//
/ /
Signature:. ' " ___ _. d. _ _ __________________ Date:_____(~.3:"~- ________
*.)(.*******.~ * **.~ .**. .***.*** y. ~ 7"7
Perm:1 t Cer . ~r"-"'Approved By: ....................................~...............~..~)at f.:l: ................ ..__._...'..~./ ~..}../ Cj y
BREMERTON PERMXT CENTER
286 4th Streetg Bremertong ~A 98337
Phone: (360) 478-5275 FAX:: (360) 478-5278
~;
Job Address: 2601 CHERRY AVE
Location: 2601 CHERRY AVE
Assr Acct No:
Building Permit No: 98-0715
Status: ISSUED
Issued: 11/23/1998
Expires: OS/22/1999
1;~E:(~UIF~ED
INS P E'C T ION S
Item: 01400 MECHANICAL
Item: 01550 PLUMBING
Item: 02150 CROSS CONNECTION CONTROL
Item: 02700 FINAL--BLDG
Dept: BLDG
Dept= BlDG
Dept: CROSSCC
Dept: BlDG
Division:
Division:
Division:
Division:
*********************************************************************************
TESTING: Must be recognized by the Washington Association of Building Officials
SPECINSP: Must be registered with the State of WA
ST OF WA: State of WA Dept. of Labor and Industries 478-4921
HEALTH: Bremerton/Kitsap Health District 478-5285
ALL INSPECTIONS PERFORMED BY THE CITY OF BREMERTON MUST BE SCHEDULED THROUGH THE
1~I=f3M'r.l. 0'=N-'-I=I~ (~14r)) ~'7.a_~?'7~
'''' '\ ,. t., ",' ".. '\ ~ \.. (;.tt. .lf1 (,) ....) If", ....) H
*********************'~,**********************************************2***' *****
~ ,/
,.,-
Pey'm :1, t 1.'ICll d H" >>ff /-
<::"1 PT'l':it"lY'f." = II- ,~ 1'')~"''t'P'' // s;{2
-,..~ ' .,."~"~~--""..."".."" "'...""Vq3/~ """
\.
BREMERTON BUILDING DEPARTMENT
Inspection Reporl
".
Scope of work:'
Address:
Owner:
Contractor:
Replace existing cooling
2601 Cherry Ave.
Bridgeview Investors
MacDonald Miller Co.
, '
t9wer Permit Number:
98-0715
. Phone:
. Phone:
373-0453
206-768-4288
FOUNDATION, '
Inspection card/approved plans on site Setbacks .
Footings: required steel placement Walls: required steel placement
Footings: required width & depth Walls: required size
Bearing soil (soils analysis if applicable) Special inspector(when applicable)
COMMENTS:
~fl.~ . t~p~~-(jW..
FOOTINGS APPROVED:
. WALLS APPROVED:
FRAMING
Electrical approved . Plumbing & mechanical ~pproved 1..
Crawl space access (min. 18 X 24) Floor joists. and beams/proper clearance to earth
Positive connections posts & beams Foundation, vents
Posts properly supported Anchor bolts: nuts & washers in place
Mudsill: treated material Floor joists: size & span
Beams/girders: size & span Notching & drilling: joists & beams, studs
,
Smoke detectors: all required locations Exhaust fans: where required
Exhaust fans insulated: unconditioned space ... Whole house fan, outside air intakes each bedroom
Fans terminating directly outisde Range hood' . .
, . ,
. Dryer exhaust vent All ventterminations: windows & property line
Fireplace combustion air , Windows: meets egress requirements
Windows: proper U valve Windows: safety glazed where required
Ceiling h~ights Stairs: headroom clearance
Sta.irs:' rise & run; proper width Fireblocking: wall to ceiling, furred walls every 10'
Fire blocking; stairs, soffits, lowered ceilings Fire blocking: tubs/showers
Fire blocking: lids in void spaces,shafts Fire blocking: stuff holes top & bottom plates
Sheetrock backing '. Wall bracing
Rafters size/notching Trusses: specs, bracing
Attic access Attic ventilation
Wall & roof sheathing Shear nailing
Building dried in
COMMENTS:
-----.-----.
-",
"-
APP.ROVED:
Insulation: proper R value Insulation:' proper fastening
Insulation:.vapor barrier Bottom plates caulked to floors
Penetrations caulked as required Electrical boxes gasketed or caulked
6 mil bla,ck poly in crawl space
ENERGY CODE COMPLIANCE
COMMENTS:
UNDERFLOOR/FOUNDA TIONINSULATION APPROVED:
WALL IN:3ULATION APPROVED:
CEILING INSULA TIOI~ APPROVED:
-
/'"
/
'r-
"
MECHANICAL
"
Appliance location and access, proper support Appliance clearance to combustibles ~
I
Venting: clearance to combustibles Venting: size & support ,
Vent termination Combustion air
Ducts: size & support Gas pipe under test
Gas pipe: size & support Gas pipe: underground min. 12" below grade
Gas pipe: within 6" or underground-coated Gas shutoff within 3' of appliance
Gas logs: safety shut-off Gas logs: damper permanently open
Woodstoves: EPA certified Wood stoves & fireplaces: Tight-fitting doors
Woodstoves & fireplaces: proper hearth Manufacturer's specs on site
Chimney liner: when required Chimney: separate flues when required
'.
COMMENTS:
GAS PIPING APPROVED:
OTHER APPLIANCES APPROVED:
FURNACE APPROVED:
PLUMBING
DWV & water piping under test DWV: proper grade
DWV: proper sizing DWV: proper drainage fittings where required
DWV & water piping: proper support DWV: required cleanouts
Vent termination All fixtures vented properly
Water supply: proper sizing Shut-off valves on all fixtures
Water heater: gate valve on cold water supply Vacuum breakers: where required
Water heater relief valve drain to outside Water heater: siesmic strap
R-10 pad under water heater when required Water-piping insulated as required
Grease trapslinterceptors: where required Proper indirect wastes: where required
COMMENTS:
PLUMBING GROUNDWORK APPROVED:
PLUMBING ROUGH-IN APPROVED
SHEETROCK
Proper fastening: nails-7" o,c. horiz. plane nails 8" O.C. vertical plane
,
Proper fastening: screws~12" o.c. horiz. plane (1/2") screws-12" o.c. horiz. plane (1/2") 24" o.c. framing
Proper fastening: screws-16" o.c. vert. plane (1/2") screws-12" o.c. vert. plane (1/2") - 24" o.c. framing
Proper fastening screws-12" o.c. horiz. plane (5/8") screws-12" o.c. horiz. plane (5/8") - 24" o.c. framing
Proper fastening: screws- 16" o.c. vert. plane (5/8") screws-12" o.C. vert. plane (5/8") - 24" o.c. framing
Area & o~cupancy separation walls Draftstops where required
Usable space under ~tairs (5/8" required) Waterboard where required (not on ceiling)
Corridors
COMMENTS:
-------......-
,/
/
SHEETROCK APPROVED:
FINAL
Energy code requirements met, exhaust fans Plumbing & mechanical
Garage/dw~lIing door self closing solid core Smoke detectors where required
Handrails & guardrails, as required Fire ratings maintained
Exit signs when required Emergency lighting when required
Occupant load posted when applicable Building weathertight
Wood siding to earth separation (6" Building Address posted
Radon monitor when required
COMMENTS:
f" FINAL APPi~OVED:
l
,t, '-"!
JUL 23
'98
\]4:28 PM
e
8 R E-, MER T Q N Q. C . 0 ,
36\] 4785.
Page
2
, . .. . . '. .
PERMI'T<ABPLxeA)3IO!'J: ...... ":::,. ........:..:.: .:::;
City~f Bremerton, W~ngt~n983j7' .':: ~hOne: (3'60F47B-5275 'FAX: (360): 478~5218
~
- -
MECHANICAL'
.rr-.
APPLICANT: 0 OWNER ~ CONTRACTOR 0 OTHER:
.PLUMBING
ctb ~ 01 \ ~
J
. -
COMMENTS: J(GP(.'/)(,($ Ex'f7? ",":/;JGW) ).10
stTEADDRESS: 2. 60) 15~f'r_._CH-eJz.iZ-'
OWN ER:$/lI1?1r6"IIJ 6~ iN v6froJL5 ..____
CONTRAcrOR:fl~[)o,J~vo /1{(...~h ~_
CONTRACTOR LICENSE /I )1fl-G0r::f'1.~].,,'/ B.:r~
OWNER PHONE #_C?6o) 3,73-0 if S-:3..
ftpo)rr.:::.,......~'- J,Je/6jftL_..
ADDRESS: 2. 60 I 51+5"'1 c:.jhE)2'~1
ADDRESS: '77/7 D€~,cr;J-vG S/,;v
f3- /- 'lor
EX!JlRATION DATE:
CONTRACTOR PHONE #(i06) 763 - 'i 118
NQ.:
TYPE OF EQUIPMENT.. :
: FEE NO;: ....
-, .:;.~TYPE. Of..FIXTU'RE: .:... .... ........ :::::F.EJ;..:
$16.50
WATER CLOSET
BATHTUB
LAVATORY
SHOWER
KITCHEN SINK
DISHWASHER
LAUNDRY TRAY
CLOTHES WASHER
WATER HEATER
URINAL
DRINKING FOUNTAlN
FLOOR SINK OR DRAIN
SLOP SINK
WATER PIPIlNC & ALTERATION
GREASF TRAP/INTERCEPTOR
HOSE BIBBS
LAWN SPRINKLER SYSTEM
SWIMMING POOL
BLDG. SEWER (mobile f mo"ed house)
ROOF DRAINS
OTHER;
PLUMBING PERMIT FEE (15.00 or 4.50)
,
f---
RANCE
WOOD/PELLET STOVE/GAS FIREPLACE
CAS FURNACE htu $:
CONVERSION BORNER btu $:
UNIT HEATER bru's:
BOILER bt11 ';:
GAS PIPING
EVAPORATJON COOLERS brus:
AC UNIT bru $:
HEAT PUMP btlii:
REHEA T BOX bMl s:
AlR HANDLING UNIT. bJIis-:
EX} lAUST FANS
RANGE HOOD (residenti"l)
RANGE HOOD (cnn'lrnerci:d)
CLOTHES DRYER
INCINERATOR
DUCT AlTERATION
TAN KS rypt::
REfRIGERATION UNIT
OTHER: RfP'y.J~e- eN sr~ h<.>,-/,v.:... /:;,/,A/r;R-
MECHANICAL PERMIT FEE
tons:
.
~-'
--
(' I ~ c;.. 7 '-t"VCX.ilA )
to c1b ---
.~.
DATE: /1- /.:;, - ~ .$
APPLICANT'S SIGNATURE:
MECHANICAL FEES:
PLUMBING FE8=;:
Crl"'t ~(Jj(~IIA:m:.E;~_ _,
TOTAl FEES:
----~-~
.1"'pp.d", r.,..,;.ocJ 1113197
:;€t: /l7I~b jP:::JdZ- ~ J77 {} /2
~ fV"\c1V~K'-; L t'C; €~ f' c.::;-