HomeMy WebLinkAboutCASCADE TRAIL, 2815 (3)
CITY OF BREMERTON - BUILDING DEPARTMENT
478.5275 - 286 FOURTH STREET, BREMERTON, WA 98310
INSPECTION REPORT
PERMIT NO.
1') '2- Co
I have this day inspected this stru,cture and these premises and have found the following violations
of City, County and/or State laws governing same:
(j)
@
5 A~-w'.e-i"
~tf YI-d.e-
rec-e-f' 4- l--k /1-:0 -I- ~,. P7/e..L
~ r"l/~~t ~ h~kJ
You are hereby notified that no more work shall be covered upon these premises until the above
violations are corrected. When corrections have been made, call for re-insp~~
Do Not Remove This Tag DATE 1-5- qJ 7L.----
INSPECTOR FOR BUILDING DEPT.
~.,
~'.
, I,
IltI DEPARTMENT OF COMMUNIlY DEVELOPMENT ill
Clll"way to tl", Olympics ,md Home of 111" PI/gel SOlHld Nllva} Shipyard
B U I L DIN G
D E PAR T MEN T
December 4, 1991
Ruth Nativida'd
2815 Cascade ~rail
Bremerton, WA 98310
RE: Building Permit #9326
Dear Ms. Natividad:
It has come to our attention that your building permit #9326,
located at 2815 Cascade Trail, expired on 6/13/91.
Pursuant to Section 303(d) of the Uniform Building Code, a permit
shall become null and void if work is not co~nenced within 180 days
from the date of issue, or if work authorized by the permit is
abandoned for 180 days after issuance.
Please contact our office at 478-5275 within 2 weeks to discuss
your intentions fo~ this project, or to schedule a final
inspection.
Sincerely,
\j~~
Permit Technician
tr
9-~I'~
V Jl~~
)
cc: file
1~1 a J q I
286 4TH STREET "6 BREMERTON, WA 98310 IIlI (206) 478-5275
A" f.qlUl1 Opporlw"ily Ernpluyc
,
_'1 \
. ' /
. ./
~ ,I
/
B R ~ M ER T ON
B U :r I.. D J N G
D E PAR T MEN T
PERMI"!"'
_"_~'_"_""_'_'M.__._.._.M.......,..._..._.._._,_..._.._.___...._._.._._._____._.._.._._._.......___.N...__..___......__._......_...._.._......_.._......_..__.__..._.....____._.__.______......
.__.,_.~._........_._..._..._,__"....._.....,._..._.....,_,~.....__.._.._,......____.___.___.._____._..,.._.,..._...........__._.......,....__._..___....._.__........._......N.___......_....__.__._..N..._..___
Application Date
I ~::,~,-~ue; Dat e
(\~3~'>f'~seo'r tlcct .tJ:
S :i. '1'; E'~ I...ocat :1. on
Owner - Last Name
..... S t 'r (:::; f~ 'I.;
..... C it )i
.".. Pho.n(~
'Yenant ' s l\la.me
(i~:v:'mt · s Naine
AY'chi teet '~3 Namf;
LX] Bu :i. J d:i nq
I.: -J 1'1 c. f" ~'l-:'> T' .', r" 0, .,
... ~-;.", ..... J (.,0\ I.. ...~ c..\ ..
[J P:I umb :i. (19
Building Contractor:
07/20/1990
07/20/1990
Application Number 90AP02190
Permit Number 11081
Project Group
2815 CASCADE TRAIL
NATIVIDAD
2815 CASCADE TRAil.
BRFMERTON
(206) 373-4698
F i Y' st F~l.JTTI
fvj I
State WA Zip 98310
Phnne( ;;::0(, )
Phone( 206 )
[ :] Gy'ading
[. ] 1"1 () 'J ,:" I;'} 11 .,' '1 cl .i 'r" Cj
. .. \.., .:).......... I..::
[ J Mob i :I e Home
Sign
Burning
I. and Clear
1"'1 pav:i nq
[ J Unden:}y'ound
I: J Demo J :i t :i on
I" ::I
[ ::I
I" ]
Work wilJ be completed by owner.
Nature of Work:
Reroof 6 squares composition.
Building Valuation
Council District
Construction
Type
f~' ,'"><''' .,' (001 .::; 1" (00' (::.\ I" V'J
... t., ~..') .. .., t..~ I .' ..' _/\.
I::> II c, .,' 'r" c.; '::. c, 1"-1
:J <>.. II;.~.~.."\.) ~ ~
Ot hey' I:: ::I
Net') [ :].
f~epa. ir [X]
1:;)'~';m("'i"le.:,'1 ["..,
,t.., I ..J... '" ...
()cld it ion [J
$810.00
:3
Cf)n~;US Tract
804
Sq Feet
Inspections
Required
Zoning
TYPE')
Foundat ion I:: ::I
Fnlm i ng I:: ']
J. ".... .1...".' r' . ,n'J
. r I~:.>U .. d L .I. ...m L
PI urnb:i n9 r]
[v] f.:'; ('" ~.. .:, 'r" .,' ,... .:, J ['"'
" .0' J It.J, I . ,,,.t~ ,. . ..1
11-" ., .Il-.)r..." Y' cl ['J
I,. t"J;. .. '" L.. ...Jc::t.. n
F:i. na 1 [X]
~:lt at us
Code
4-
I~('~(rsj. ~./(-~d 13)' ':. (.lPpnNed By:: -
:::::::.::::~~"""';:::g~:~:~:~:::::::::::::::::::::::::::::::::::::::::::::::::::.:::::::::::::::::::::::::::::::::::.::;:::::::::::::::~~:::::::::::::::::::J::::i,,?2::.C?:::J::::2::::~:::::;::.
" ,
Ci ty of Brenlertott
239 FOURTH STREET
BREMERTON, WASHINGTON 98310
(206) 478 - 5252
MA YOR GENE LOBE
B U I L DIN G
D E PAR THE N T
November 8, 1989
Ruth Natividad
2815 Cascade Trail
Bremerton, WA 98310
RE: Building Permit #9326
Ms. Natividad:
Thank you for your prompt response to our letter regarding the
expiration of your building permit.
Our records show that you have not requested a building inspection
since 5/26/89, when we performed a plumbing inspection. Inspection
requests are the only method we have of determining if a project
is on-going or has stopped. Since you state that you are still
working on your remodel, the permit will continue to be active.
If you do not request another inspection within the next 5 months,
we will again request that you inform us of the status of the
project.
If you have any questions, feel free to call me at 478-5281.
Sincerely,
~~~~~
Permit Technician
cc: File
Gateway to the Olympics and Home of the Puget Sound Naval Shipyard
~y ~..~ k(~' 9~ ~'J'
~ ~ 11Ar1--- ~...0 ,.
dt:!:~ w=J ~ ~~
lh~ ~~.- if-
~~ ~4 ~~
.~ orA~~-
(if-~I ~~~M
fL,rhy. AM ~~ ~ . }-&-O-J
'->v .Y-frvr- fD ~ ~ ~
~ ~ ~L d-- wv-z/u ~
.., J ,I. J
~~~y ~~~~v-
~~+o~_ J~~
.~ At /~ +--~ ~ rr-
.~~. J-~ Tv
,Wd- ~ ~ff ~
)g.~ :Zt!J~.. ~~.)~
"~" J~(~~
~ ~- ~ Cl-vv0 ~~ ~
~if-~~.~
~ -~ ! 0 -(~ ,~r/J-- 1"vf-T-o
~
J~~~
!lJ1l@Il!l{fJ ~ ~~
/VOII 8 IlIfJ
1989 .
, 8UllIJIZ;tMtIlTON
DtP41'MtNT
~ ~.'.
.- .:-.,
.OJ
tt! ':? f
....1 '
~
. .-1)
-" c r.f
~ t! -+
~r .
9-lJ'
2 r
w ____ Jd
~ -.0.'
~f..
~
f
~
~
r~
(
r
C' S't:~.
......... r 'Y -"',
i.D -0 oJ,(
CO;Z -= \-1
\LP c ..:s. I.."
<: , ~'~{
\. . 1~1.1!
..... IfJ~ ~.
.~.
..
~
~,>
18-CH16D1-1
Super Efficiency Gas-fired
Condensing Furnaces
(BLU-K-B; BLD-K-B; TUC120A960Aj
: ~~~:.;'
PV:~ ":;..,.
@ American Standard Inc. 19118
'",
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other
appliance.
WARNING
FOR YOUR SAFETY
If you smell gas:
1. Open windows
2. Don~t touch electrical switches
3. Extinguish any open flame
4. Immediately call your gas sup-
plier.
, dwg, rio.2'1X137235 P06
i.~
...-
INSTALLER'S GUiDE
,
B. Clearance for combustion and ventilation (see AIR FOR
COMBUSTION AND VENTILATION)
r' C. Clearance for attaching duct work (See DUCT CONNEC-
. TIONS)
D. Clearance for proper installation of venting and for running
condensate drain to the floor drain (See VENTING and
CONDENSATE DRAIN INSTRUCTION, Pub. No.
18-CHI5D1.)
E. Clearances for any external filter racks or sub-bases to be
used.
F. Clearances for gas piping (See GAS PIPING).
The installation must conform with local gas company regula-
tions, national and local electrical codes, local building, plumb-
ing or, in the absence of local codes, with the latest National
Fuel Gas Code ANSI Standard Z223.1-1984.
INSPECTION AND HANDLING
Material in this shipment has been inspected at the factory and
released to transportation agency without known damage.
Inspect exterior of carton for evidence of rough handling in
shipment. Unpack carefully after moving equipment to
approximate location. If damage to contents is found, report
damage immediately to delivering agency.
ORDERING PARTS
When ordering shortages or damaged parts, or when ordering
repair parts, give the complete unit model and serial number as
stamped on the unit nameplate. Order all parts through your
local contractor.
INSTALLATION, CLEARANCES AND
SUPPORT
UPFLOW models are A.G.A. design certified for installation on
combustible floors and for closet installation.
For installation on combustible flooring, the furnace shall not
be installed directly on carpeting, tile, or other combustible
material other than wood flooring.
DOWNFLOW (counterflow) models are A.G.A. design certified
for installation on noncombustible floors and for closet installa-
tion. For installation on combustible floor use combustible floor
subbase. Combustible floor subbase must also be used when
cooling coil and jacket are applied in installation on combusti-
ble, floor.
The following lists minimum permissible clearances to com-
bustible material, for all models of recuperative gas furnaces.
TOP OF PLENUM
I"
ACCESSIBILITY CLEARANCES MUST TAKE PRECE-
DENCE OVER FIRE PROTECTION CLEARANCES.
Minimum accessibility clearances are as follows:
1. 24 inches at side where access is required for servicing and
cleaning.
r' 2. 18 inches at a side where passage is required to another side
. '., . requiring servicing or cleaning, or at a side requiring inspection
or replacement of the flue connector.
dwg. no. 21 X137235 P06
3. In utility room installations, the door shall be wide enough
to allow the largest furnace part to enter or to permit the
replacement of another appliance, such as a gas water heater.
4. Where external filter racks are used, clearance must be
provided for removal of filters.
The furnace must be installed on a solid surface and must be
level front-to-back and side-to-side.
If this furnace is installed in an attic or other insulated space it
must be kept free and clear of all insulating materials as some
insulating materials are combustible.
If additional insulation is added after the furnace is installed,
the area around the furnace must be inspected to insure it is
free and clear of insulation.
AIR FOR COMBUSTION AND VENTILATION
OUTDOOR AIR IS RECOMMENDED.
When installing the BLU-K and BLD-K gas furnace, it is
recommended to use the outdoor combustion air option. The
use of indoor air for most applications is acceptable, unless
there is the presence of corrosive chemicals or contamination in
the air supply. Certain types of installations will require the use
of outdoor air for combustion. For further information regard-
ing the combustion air option, refer to Installer's Guide (Pub.
No. 18-CHI5Dl), Venting and Condensate Dmin Instructions
for these Gas Furnaces.
When the furnace is installed with the indoor air option, the
following guidelines must be followed:
1. If the furnace is installed in a confined space, the necessary
combustion air must come from the outdoors by way of attic,
crawl space, air duct, or direct opening.
2. There must be no exposure to the corrosive chemicals
and substances identified in the Venting and Condensate
Drain Installer's Guide.
3. All provisions for indoor combustion air must meet the
requirements for combustion air supply indicated in the
National Fuel Gas Code, ANSI Z223.1-1984, section 5.3, and/
or any applicable local codes.
AIR FOR COMBUSTION AND VENTILATION:
(Extracted from National Fuel Gas Code ANSI Z223.1-1984)
5.3 AIR FOR COMBUSTION AND VENTILATION
5.3.1 GENERAL
a. The provisions of 5.3 apply to gas utilization equipment
installed in buildings and which require air for combustion,
ventilation and dilution of flue gases from within the building.
They do not apply to (1) direct vent equipment Which is con-
structed and installed so that all air for combustion is obtained
from the outside atmosphere and all flue gases are discharged
to the outside atmosphere, or (2) enclosed furnaces which
incorporate an integral total enclosure and use only outside air
for combustion and dilution of flue gases.
b. Equipment shall be installed in a location in which the
facilities for ventilation permit satisfactory combustion of gas,
proper venting and the maintenance of ambient temperature at
safe limits under normal conditions of use. Equipment shall be
located so as not to interfere with proper circulation of air.
When normal infiltration does not provide the necessary air,
outside air shall be introduced.
page 3