Loading...
HomeMy WebLinkAboutBB03 00729BUILDING PER34-IT INSPECT CARD': PROTECT THIS CARD FROM THE WEAMER SITADDF2AES Sao 1 '�,aw TPhR t E� Tk )DtIET -31 Fire �kPpression In hood..�'�deN ]wilding ❑ Plumbing ❑ Mechanical c ElFire Alarm/ +i; -,r, r , DURING INSPECTIONS THE BUILDING PERMIT & APPROVED PLANS SHALL BE ON SITE Permit For Inspections Call (360) 473- 5870 Approved Dale Notes 1st FOUNDATION DO NOT POUR CONCRETE PRIOR TO APPRO'\7AL Erosion Control In Place Foundation Footing Foundation walls Plumbing Ground YPork In Slab Mechanical Footing Insulation �ud PLUMBING MECHANICAL GAS PIPE Rough In Duct/ Vent Support / Test / Meter set 3rd FRAMING If Is' &, 2nd are approved hold down. connections Shear Panel nailing L&.I Electrical Approved Ventilation requirements Framin- th 4 INSULATION Under -floor walls ceiling 5th SHEETR0CK 6th All of the above FINAL Must be approved 1 Prior to final TV.4TER MAIATTEIVANCE 473=5927 Grease La ,Back flow, Meters 001po FIRE 473-538415.'385 ALL FINAL INSPECTIONS COMPLETED DO NOT OCCUPY BUILDING NA71THOUT BUILDING DEPARTMENT APPROVAL OCCUPANCY VIOLATION IS A MISDEMEANOR- SECTION 305(d) PROTECT THIS CARD FR 014 THE Tf E 4THER CITY OF BREMERTON PERMIT NUMBERBB0 03 0729 E- 5 DEPARTMENT OF COMMUNITY DEVELOPMENT DATE ISSUED: 12%29/2003` Emd286 Fourth St. Bremerton, WA 98337 (360)478-5275 Fax: (360)'478-5278 ASSESSOR NUMBER: 022401-3-008-2001 ZONING: MF SITE ADDRESS: 3201 PINE RD NE APPLICANT NAME: KNIGHT FIRE PHONE: ADDRESS: 3201 PINE RD OWNER NAME: PHONE: ADDRESS: CONTRACTOR: KNIGHT FIRE PROTECTION INC PHONE: (360)786-8606 ADDRESS: 9702 LATHROP INDUSTRIAL DR SW LENDER NAME: PHONE: ADDRESS: SUBMITTED: 12/04/2003 APPROVED: 12/12/2003 EXPIRATION: 06/26/2004 9. Contact (360) 473-5385 for testing appointment ^ MINIMUM INSPECTIONS REQUIRED Inspection requests must be received by 8:00am in order to be scheduled for same day. To request an inspection, please call (360) 478-5275 and be sure to provide your permit number, name on permit, site address, contact phone number, and inspection type. Cross Connection Control Final Inspection - Fire Page 2of2 A • CITY OF BREMERTON" DEPARTMENT OF COMMUNITY DEVELOPMENT Receipt Number: BDDO 286 Fourth St. Bremerton, WA 98337 (360)473-5275 Fax: (360) 473-5278 Page 1 of 1 Receipt Date: 42/26/2,003 Al 0 Cashier PCONROYPayer/Payee Name KNIGHT FIRE . .. , Original Fee Arr►ount ': Fee. Permit# Fee Descriptions ° Tran : � Code'Amount Paid,-- Balance �� BB03 00729 State Surcharge 1/0236 $ 4.50 $ 4.50 $0.00 BB03 00729 Building Permit 1/2211 $ 83.25 $ 83.25 $0.00 Total: $ 87.75 a PreviousPayment History ., Receipt # Rec:eiPt Date F..ee Descriptiom, Amount Pa d, Permit #, BDD0001084 12/04/2003 Plan Review Fee $54.11 BB03 00729 Payment', �Check ' - Pay merit Aethod fim .Number 'a• �. Amount CHECK 13967 $ 87.75 Total: $ 87.75 Page 1 of 1 '"32/ 2UU31 10:29 3604735278 BREMERTON DCD �1 ERZ BuB.dirxg Permit Application APPLICANT: ❑ OWNER CONTRACTOR ❑ AUTHORIZED AGENT Site Addre___ sc /�� y ,d P� Tax Account Number>���¢/)/ .fin! CONTRACTOR: OWNER Name: Address- S Address: Cit ,State, Zi city, State, Zip Phone #: Phone #: License G Ex ir. pate, thorized Agent -Address- Contact Name: City, State, Zip Contact Phohe #: Phone #: � i Check the tv e of application f TT r below. ee 0 _(D d -� ❑ NEW SINGLE-FAMILY RESIDEN E ❑ NEW COMMERCIAL L]NEW GARAGE/� R O T r-� PLEX NEW DU 2r COMMERCIAL REMODEL ❑ :,NEW.ACCWSOP,Y G L 1 NEW MANUFACTURED HOME COMMERCIAL ADDITION ❑ NEW SIGN RESIDENTIAL REMOOSLGdMMERC RESIDENTIAL ADDfTION I—A RE P R - ❑^ STRU - ,E DEMOLITION 1_1 ❑ RESIDENTIAL E] NEW MULTf-fcAMILYj "❑ GRADING (Cubic yards: } REPAIR ❑ TENANT IMPROVEMENT ❑ 07HER IS THIS PROPERTY WITHIN 200 FEET OFA SHORELINE? YES ❑ NO ❑ Square Footage: -Dwelling: Garage:. Decks: Valuation;] Plan Review Fe Permit Pee Surchar e Total Fees Application for which no po:mit is Issiaeehwithin 180 days following the date OT applica lon shall expire by limitation, and pians and other data submitted for review may thereafter be returned to the applicant or destroyers by the building official. The building efficial may extend ttie time for''Zction by the applicant for a period not oxceeding i80 days on request by the applicant showing the circumstances beyord�t'he control of the applicant have prevented action from being taken, No pppliczOt shall be extended more than once, in order to renew action on an application aftRr cxpir rien, the applicant ,, half resubmit plans and pay a new plan re sew fiee. APPLICANT'S"SI.GNATURE: DATE: r4 - . t. KNIGHT FIRE PROTECTION, INC. 9702 LATHROR INDUSTRIAL DRIVE SW OLYMPIA, WA 98512-9188 360-786-8606 FAx 360-786-8722 CONTRACTOR'S LICENSE NO. # KNIGHFP044LK "ON GUARD 24 HOURS A DAY" TO: WE ARE SENDING YOU: TRANSMITTAL Fig WET��/lW CO IES DATE NO. DESCRIPTION n n _ 11 'EC 0 4 THESE ARE TRANSMITTED AS MARKED BELOW: For approval ❑ For your use ❑ As requested ❑ For review and comment REMARKS: COPY TO SIGNED IF ENCLOSURES ARE NOT AS DESCRIBED, PLEASE NOTIFY US AT ONCE. A .dn- is R- -0r w w A w s 0 ;z} "I - I� mc E iU o ii. . E z Q) - U zi O O LL d 1 L W U U 1� L.L o ui O 0 ;z} "I - O o U E z Q) - U zi O O d F- O U N L ui O p O w - O W O O n/ L.L O LL Q. O I C !n O v L L z U cB O 0 ;z} "I - F- 13� Lx.1 U F- cn ' U I — cn W(n� ii c� ( Q O -� •� � i, O W — j O m (a2 Z U) O LL C U C N f _ E � Ur Co c OC) C� N O L !n 0 •Q p' E cn ,X O L W U) i T 0 C -0 � � V C O cv c M L ry iii w lu�rbll� o iol y L/I ' B/REMERTON DCD .(360) 478-5275 * Fu (360) 478-5278 Building Permit Application APPLICANT; PAGE J 1 l� CONTRACTOR: OWNER Name: Address- `;0 Address: Cit , State, Zi City, State, ,Zip Phone: Phone #; License - ; ' L G Ex Ir. Date. thorized Agent AdGress, Contact Name; City, State, Zip Contact Phone: ) Phone 'Fut: _ { (.,necK tl)e tVAe of application ❑ NEW SINGLE-FAMILY RESIDE ❑ NEW DUPLEX ❑ NEW MANUFACTURED HOME ❑ RESIDENTIAL REMODEL ❑ RESIDENTIAl, ADDfTION RESIDENTIAL REPAIR JOL 5 b NEW COMMERCIAL COMME=RCIAL REMODEL COMMERCIAL ADDITION CCMMER3. 1 � REPm­ 7ENAN71MPROVF=MENT R NEW MULTI-FAMI_"`' IS THIS PROPERTY WITHIN 200 FEET OF A SHORELINE=? ❑ NEW GARAGE/CA'.R PO ❑ NEW.ACC)=WaDP,Y G n NEW SIGN 5 I Rr�tRE DEMOLITION GRADING (Cubic yards: ) OTHER YES ❑ NO ❑ Square Footage: Dwelling: Garage:. Decks: Valuation Plan Review 're Permit Fee Surchar e Total Fees Application for which no pai'mlt is issued -within -180 days 'following the date of epplicatlnn shall expire by limitatl0n, and . plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the building ofrioial. he building official may extend the time for'action by the applicent for a period not exceeding ISO days on request by d€ .; the applicant showing the circumstances beyond the control of the applicant havp prevented actioh from being taken. Na applicant shall be extended more than once. In order to renew action on an application after expirxlpn, the applicant shall resubmit ,plans and pay a new plan re iew flee. �rw ' APPLICANTS SIGNA © TUP,E: DATE: c z _ n ®`3 \1 O �i le,MI . D m — ap >; -p m I— �l ClJ r� , oU) Cao �I O)' CJl -l? t N N-- O m -.J cn P Co N m # 1 j C r w rn oV --<X n n = SSp —tf'�lrn� o n C ou �o D rn N) cn :O rNv rte- C6rY®� ® AZO DSD�i=zmcDn Zon © N z � � - M. o � o p�mN=-1--i :.. rn cn . .D0Z�-D� oa cn D t� _ CO �, rn -1 mC)rmcF-r�0 -P O �7 C) m -D rn t1 -� �� O Q m b � D M D 7C C c z _ n ®`3 \1 O �i le,MI . D m — ap >; -p m I— �l ClJ r� , oU) Cao �I al W9 r" C-) a 9 I 3iwa i a �t•a m # w rn n T C m m M 1 N ® w W al W9 r" C-) a 9 I 3iwa i a �t•a r ■ KITCHEN KNIGHT® If: ,yt T i' : R 21'AUR Pyro .•' E SUP PRESSION SYS;TEIVI--... PCL�3O:Q4fi.0/600 TECH N ICAL • COMPONENTS • DESIGN • INSTALLATION • MAINTENANCE' •.RECHARGE iAR le'm, I i October 1, 2001 Manual No. PN551274 i TABLEOF CONTENTS Page Subject Revision Date Page Subject . Revision Date General Information System Installation 1-1 Introduction 41 General Components �s �. Cylinder Installation �" Ccntrol Head Installation 2-1 Cylinders & ValvesSingle Kr1 Cylinder Introduction :Valve Rebuilding Equipment 4-2 Multiple Cylinder Installation 2-2, Cylinder Bracketing -4-3 Multiple Cylinder Installation (cont.) Extinguishing Agent 4-4'' Fusible Link Detector Installation 2-3 • MCH3 Control Head Fusible Links Without Hangers I ECH3 Control Head 4�5 Fusible Links With Link Hangers. NMCH3 Control Head 4-6, Thermal Detector Installation EN-MCU3 Enclosure Setting The Control Head EN -S Enclosure MCH3 Control Head 2-4 MB -P2 Mounting Bracket ECH3 Control Head PAC -10 4-7 Solenoid Monitor Installation 2-5 Detection Equipment In A Detection Circuit ...FLK -1 4-8 Solenoid Monitor When Used As ...FLK -1A A Reset Relay ..FLH-1 Remote Pull Station Installation 2-6 Fusible Links 4-9 Remote Pull Station Installation (cont.) Thermal Detectors 4-10 Gas Shut Off Valve Installation RPS -M Remote Pull Station Mechanical Gas Shut Off Gas Shut Off Valves Valve- Installation GV Shut Off Valves Electrical Gas Shut Off Valve 2-7 EGVSO Gas Shut Off Valves Installation Corner Pulleys 4-11 Tee Pulley Installation SBP -1 Corner Pulleys Miniature Switch Installation CBP-1 Corner Pulleys 4-12 Pipe and Nozzle Installation WBP-1 Corner Pulley System Checkout After Installation 2-8 Tee Pulley 4-13 System Checkout After Electric Switches Installation (cont.) SM -120/24 Solenoid Monitor 4-14 Blank 2-9 Pipe and Fittings Enclosure Installation Nozzles 4-15 Enclosure Mounting Swivel Adaptor Fusible Link Detector Installation 2-10 Components List 4-16 Setting the EN-fvlCU3 System Design Remote Pull Station Installation 4-17 Gas Shut-off Valve Installation 1 Nozzle Coverage and Placement a-18 Miniature Switch Installation Duct Protection 4-19 Cylinder Installation Transition Ducts Single Cylinder Installation 3-2 Electrostatic Precipitator Multiple Cylinder Installation Plenum Protection 4-20 System Checkout After Installation 3-3 Appliance Protection Fryers Svstem Maintenance 34 Range (Two Burner) 5-1 General 3-5 Range (Four Burner) Semi -Annual Maintenance Small Wok Annual Maintenance Larne Wok 12 -Year Maintenance 3-6 Small Griddle System Recharge Large Griddle 6-1 General 3-7 Gas Radiant Char -Broiler System Cleanup Natural Lava Rock Char -Broiler System Recharge Charcoal Char -Broiler 6-2 System Recharge (cont.) 3-8 Mesquite Char -Broiler Upright/Salamander Broiler 3-9 Chain Broiler Tilt Skillet/Braising Pan 3-10 Fryer — Multiple Nozzle Protection Piping Limitations 3-11 General Piping Requirements Design Steps 3-12 Design Steps (cont:) 3-13 Design Steps (cont.) 3-14 Design Steps (cont.) 3-15 • Detector Placement ULEX 3470 Indicates Revision PN551274 October 1, 2001 Chapter 1 — General Information Page 1-1' CHAPTER I ;. } GENE,R-ALiNFORMATION INTRODUCTION.. r The Pyro-Chem Kitchen knight II Restaurant Fire Suppression System is of the pre-engineered type as defined by NFPA- 17A Standard for Wet Chemical Extinguishing Systems and is designed to provide fire- protection for restaurant cooking appliances,, hoods, and ducts. Installation and maintenance of the system must conform to the limitations detailed in this manual and be performed by an'Authorized Pyro-Chem Kitchen Knight II dealer. The Pyro-Chem Kitchen Knight IISystem utilizes a wet chemical agent specifically designed to suppress restaurant cooking area fires. The system provides automatic. actuation and can be manually actuated- through a remote mechanical pull station. Upon actuation, the system discharges a pre -determined amount of agent to the duct, plenum, and cooking appliances. The agent acts to suppress fires in three ways: 1.The chemical chain reaction causing combustion is interrupted by both the agent itself and the resulting steam formation. 2. The agent cools the fire bringing it below auto -ignition temperature. 3. The agent reacts with hot grease forming a soap -like layer (saponification) that helps prevent the escape of combustible vapors, thus preventing re -ignition. The shutdown of fuel and power to all appliances under protected ventilation equibment is required uoon system actuation. The shutdown of make-up or supply air is recommended upon system actuation but is not required. Exhaust fan(s) in the ventilation system should remain on during system discharge as they assist the dispersion of chemical through the ventilat- ing system. The system is UL Listed with or without exhaust fan shutdown. t TEMPERATURE LIMITATIONS The operating temperature ranae of the Pyro-Chem Kitchen Knight II System is 32° F. (0° C.) maximum. minimum to 120° F. (49° C.) UL LISTING The Pyro-Chem Kitchen Knight II.Restaurant Fire Suppression System has been tested to the UL Standard for Fire Extinguishing Systems For Protection of Restaurant Cooking Areas UL300 and Listed by Underwriters Laboratories. Inc. System agent cylinders bearing the Underwriters Laboratories of Canada. Inc. ULC mark also meet Underwriters Laboratories of Canada's Standard ULC/ORD-C1254.6-1995. ULEX 3470 PN551274 October 1, 2001 CHAPTER II COMPONENTS --—.0,. CYLINDERS & VALVE a.-0 The Pyro-.Chem Kitchen Knight II' System has available 'three r different size cylinders: the Models PCL -300 (P/N 551194), PCL -46011 (P/N 551193), and PCL'600.(P/N 551196). Cylinder . sizes are expressed in terms of extinguishing agent capacity (i:e., the•PCL-300'uses 3.0 gallons of extinguishing agent) The cylinder is manufactured, tested, and marked in accdr dance_with DOT 4BW225. Cylinders come pre -filled with - extinguishing agent' and are charged with dry nitrogen to a, press ure.of,225 psig.@ 700 F. Cylinder and valve assembly dimensions are shown in Figure I�. C I I A Max. Flow Mounting Model Point No. q B C Bracket D 001 8.00 125.06 Caoacity Weicht Used PCL -3 30.81 22.75 1 To 1 53 Ibs. j 46-15 PCL -460110.00 125.06 j 30.81 1 22,75 j 15 j 63 lbs. MB -15 PCL -600110.0035.81 I41.56I 33.501 20 �108Ibs.� MB -1 Figure 2-1. Cylinder and Valve Assemblies. 00264, PC All cylinders utilize the same valve assembly (P/N 551175). It is a pressure sealed poppet type valve designed to pro- vide rapid actuation and discharge of agent. See Figure 2-2. Item I Part Number I Dacrri�� 8 550716 Neck 550713—TprP�, 550714 1Valve C O 550715 Piston O -Ring 550710 Valve Stem 551256 Pressure Regula 551261 Seal 17851 6-32x3/32x3/�w . Y Chapter 2 Components Page 2-1 U Figure 2-2. Valve Cross Section. 006212PC VALVE REBUILDING EQUIPMENT 1. Wet Valve Seal Rebuilding Kit (P/N 550698). After system discharge, the valve assembly must be rebuilt to ensure proper future operation. The Wet Valve Seal Rebuild- ing Kit (P/N 550698) should be used. It includes all compo- nents necessary to properly rebuild the valve. See Figure 2-3. ULEX 3470 PN551274 October V, 2001 Figure 2-3. Wet Valve Seal Rebuilding Kit (P/N 550698). 002906PC !m Part Number Description 550762 Cap 8 Seat Washer Sub -Assembly y1550705 Spring 1 550716 I Neck O -Ring 1 550028 Stem O -Ring 550715 Piston 0 -Ring 1550710 [ Valve Stem ULEX 3470 PN551274 October V, 2001 Chapter, 2 — Components:: ' Page 2-2 2. Pressure Reg ulator Assembly (P/N 55098511' h The pressure ;`regulator assembly is available if the 'complete ;.regillatdr requires,reolacement (i e., possible thread damage) 31. Pressure Reg.alator Rebuilding Kit ,. (P/N 551061) After system discharge, the pressure regulator must be rebuiIt: .to ensure proper future operation. The rebuilding kit (P/N 551'061): should be used. If includes all components necessary to.properly rebuild the regulator. See Figure 2-3.1 IN VALVE SEAL.PART BODY NO. 551261` /PART X 3/8 IN, SCREW, PART N0. 17851 INTERNAL O-RING, PISTON I � PART NO. 402745 C -RING. I / SPRING. PART PART NC NO. 551170 12837 i I ` 4L _-_.._..—.._. /� n PISTON EXTERNAL 0 -PING. PART NO. 5512'3 .4 48-32 X 3/6 IN. HOLDING SCREW. PART N0. =19045 Figure 2-3.1. ooesa_,>c 4. Model VT -1 (P/N 550788). The Model VT -1 wet valve tool is designed to facilitate the rebuilding of the wet valve assembly. It should be used to hold the wet valve piston while unscrewing the cap and stern assembly. See Figure 2-3.2. Figure 2-3.2. Model VT -1 Wet Valve Tool. 002907PC ULEX 3470 October. 1, 2001 PN551274 CYLINDER BRACKETING,, .a Vertical bracketing of the PCL -300 and PCL=46i)°`�s`provided by the Model MB -15, bracket -.kit TN .550054). Vertical brack- eting of the PCL -600 is provided by the.Model MB -1 bracket kit (P/N 550053). These kits must be 6rapred separately with each cylinder/valve assembly. Cylinder installation:'lr)struc- tions are provided in the installation section of'this manual. EXTINGUISHING AGENT (P/N 551188) The agent used in Pyro-Chem Kitchen Knight 11 Systems is a potassium carbonate based. solution •that is. extremely. effec- tive for grease related kitchen fires,' This agent is available for cylinder recharging in 3.0 Gallon containers (Model PCL -300)., For MSDS information, contact Pyro-Chem at 800-526-1079 or 715-732-3465 or wvvw.pyiocherrl.com. CAUTION Precautions must be taken when handling and transfer ring wet agents as they are caustic in nature. Goggles must be worn at all times. If any agent gets into the eyes, they should be flushed with clean water for 15 minutes and a physician contacted. If any agent con- tacts the skin, it should be flushed with cold water to prevent irritation. The agent is electrically conductive. Care must be taken to thoroughly clean up any agent discharged around electrical appliances before turning the power on. After system discharge, agent must be cleaned up immedi- ately with hot. soapy water to prevent corrosion of effected surfaces. r, d .. MODEL MCH3 MECHANICAL CONTROL° H8 -AD. (P/►" 551200) r :.� The Model MCH mechanical -control head is a fully mechanical, control head which'•can be connected to the PCL -300/460/600 cylinder valve. This control head will sup- Port:a fusibleaink detectioD system!i a remote mechanical Pull station.(Model-.RPS-M), and a mechanical or electric gas shutoff valve. A -miniature electric switch (Model MS-SPDT, MS-DPDT,�.MS-3PDT or MS-4RDT)''can be ordered sepa- rately-and'field installed.It,is equipped with a local manual control handle that'allows.for mechanical system actuation. Operation' of: the- local manual control requires removing the pull pin and Totating,the handle clockwise. The Model MCH3 control head: can actuate=a maximum of three (3) cylinders. See Figure 2-4. MODELYMCH3 CONTROL HEAD r� KI-' AN, TUW MAICLE `�AsETO� oSPPFESSM sySTEN PTpp ".OqEM i OY( 'ErTE. mat un.cac, n suu.2,2 . (U Figure 2-4. Mechanical Control Head. 00:79pPc MODEL ECH3 - ELECTIIRIC CONTROL HEAD The Model ECH3 electric control heads is an electrically oper- ated control head which can be connected to the PCL - 300/460/600 cylinder valve. This control head will support an electric thermal detection system, a re; ote mechanical pull station (Model RPS -M), and an electric; gas shutoff valve. It will not support a fusible link detection!"system. A miniature electric switch (Model MS-DPDT) is included. The Model ECH3 control head is available in both ;120 VAC (Model ECH3-120, P/N 551202) and 24 VDC (Model ECH3-24, P/N 551201). It is equipped with a local manual control handle that allows for mechanical system actuation. Operation of the local manual control requires removing the pull pin and rotat- ing the handle clockwise. The Model ECH3 control head can actuate a maximum of three (3) cylinders. See Figure 2-5. LMODEL ECH3 CONTROL Ru nr. iwae TO RMEAW Fyfe' RFPW—.sm SY M PM CKN ort arms O wiaia, n �...u-tsa � Figure 2-5. Electric Contro11 l Head. OOg8YFc Chapter 2 - Components Page 2-3 MODEL NMCH3 MECHANICAL CONTROL HEAD (P/N,,551203) The Model NMCH3'Mechanical .Control Head is a fully'.. mechanical control head which Gari be connected to the PCL -300/460%600 cylinder" valve.,This'control. head will sup- port a fusible link detection system,,a remote mechanical pull station (Model RPS -M), and'a mechanical or electric gas shut-off valve. A miniature electrical switch (Model MS-SPDT, MS-DPDT, MS-3PDT, or MS-4PDT) can be ordered separate- ly and field installed. There is no local manual actuation for the Model NMCH. The Model NMCH3 control head can actu- ate a maximum of three (3) cylinders. The Model NMCH3 . can be used as a direct replacement for the Model MCH3. MODEL EN-MCU3 ENCLOSURE (P/N 551208) The Model EN-MCU3 Enclosure is used for vertical mount- ing of a single PCL -300 or PCL -460. The EN-MCU3 also includes a mechanical control unit, eliminating the need for a Model MCH3 Control Head. See Figure 2-6. The PCL -600 cannot be mounted in an EN-MCU3. ® o 0 O 28.125 r �-13.125 (FROWn (SIDE) Figure 2-6. Model EN-MCU3 Enclosure. 0028+5=c MODEL EN -S ENCLOSURE (P/N 550966) The Model EN -S Enclosure is used for vertical mounting of a single PCL -300 or PCL -460 when it is used as a secondary agent cylinder in a system. The EN -S has no -control mecha- nism, and must be used in conjunction with a Model EN-MCU3 Enclosure or a Model MCH3/ECH3 Control Head. The PCL -600 cannot be mounted in an EN -S. ULEX 3470 PN551274 . October 1, 2001 Chapter 2.— Components, Page_2=4 MODEL MB -P2 = CONTROL HEAD MOUNTIN wB"RAQKET (P/N 550853) The Model M&P2 mounting bracket mustbeused .to mount the ModAl MCH3„ NMCH3, or ECH3 control heads if the con= 'trot head is "not mounted"directly on a cylinder valve. See Figure 2=7. Figure 2-7. Model MB -P2 - Control Head Mounting Bracket. 002846-C PNEUMATIC ACTUATING CYLINDERS 1. Model PAC -10 (P/N 550104). The Model PAC -10 is a pneumatic actuating cylinder that can actuate a maximum of ten (10) agent cylinders simultaneous- ly. The Model PAC -10 includes a DOT 4BA350 cylinder pres- surized with dry nitrogen to 350 PSIG @ 70` F., a brass valve with pressure gauge, and a wall mounting bracket. A Model MCH3, NMCH3. or ECr3 control head must be pur- chased separately and connected to the PAC -10 to open the valve. See Figure 2-8. MODEL MCH3. NMCH3. OR ECH3— CONTROLHEAD (SOLD SEPARATELY) n 4 •J -— 3/4• DISCHARGE PORT 20.25 145d 12.25 — 4.00 Figure 2.8. Model PAC -10 Pneumatic Actuating Cylinder. 002847PC ULEX 3470 October 1, 2001 PN551274 F nents Chapter 2 — Compo Page 2-5 'I DETECTION EQUIPMENT 3. Model FLH-1 (P/N 550876). " The Model-FLH-1 fusible link hanger js-an�acc�ssory 1. Model ,5LK-1 (I3I4-°550131). - - ,,r- _ ,- designed to simplify. the-installati�on:;,df fusible links in the fusible link line. It can be used withwthe Model FLK -1/1A The Model FLK -1 fusible link kit includes a 10" steel bracket, s fusible link kit (kits must be ordered separately). The Fusible two (2) 1/2" EM1Qo'nnectors, two. (2) cable crimps, and two Link Hanger makes it possible to install fusible link`s without (2) "S" hooks. Fusible links must be ordered separately. See cutting and crimping loops in the fusible link line for each Figure 2-9; link. They are available in packages of 25 (FLH-25) only. See Figure 2-10. 2. Model FLK -1 A (P/N 550132). �I The Model FLK -.1 A fusible link kit includes an 8" steel brack- et, two (2) 1/2" EMT connectors, two (2) cable crimps, and two (2) "S" hooks. Fusible links rhuist be ordered separately. LINK DETECTOR BRACKET TERMINAL LINK ��w 1/16" STAINLESS STEEL CABLE LINK SERIES LINK Figure 2-9. Model FLK -1 Fusible Link oozeay=;, FUSIBLE. LINK KIT (SOLD SEPARATELY) FLH-1 BLE LINK HANGER 12" EMT CONNECTOR CABLE CRIMP - FUSIBLE LINK (SOLD SEPARATELY) Figure 2-10. Model FLH-1 Fusible Link Hanger 002&WPC PN551274 ULEX.3470 October 1; 2001 Chapter-2:Components Page 2 6 4. Fusible Links. EMT with corner pulleys at each change in direction,.The remote mechanical pull station shall be located at the point The fusible link is designed to separate at a specifid,tf-,m, per- ..,of egress. See Figure 2-12. ature, releasirlq iensien f 'dm the fusible link fjrte;J,causing +. Figure 2-11. ML Style Fusible Link. • 002851PC After determining the maximum ambient temperature at the fusible link location. select the correct fusible link according to. the temperature condition chart below: Fusible Link Maximum Ambient Model No. Temperature Part Number FL -165 95° F. (35° C.) 550368 FL -212 142° F. (61 ` C.) 550365 FL -280 210° F. (99° C.) 550366 FL -360 290° F. (143° C.) 550009 FL -450 380° F. (193` C.) 550367 FL -500 430° F. (221 ` C.) 56816 4iu STANDARD <- X <- ELF AA CTION BOX 1u- RADIUS ON ALL CORNERS RIDGED BRUSHED ALL*ANUm FACE PLATE RED PLASTIC BREAK ROD IrRING PULL HANDLE Figure 2-12. Model RPS -M Mechanical Pull Station. 002852°C GAS SHUTOFF VALVES 5. Thermal Detectors. 1. Mechanical Gas Shutoff Valve. Fixed temperature thermal detectors are normally open. mechanical contact closure switches designed to operate at A eas shutoff valve is required on all systems used to pro - a factory preset temperature. They are available in four pre- tett a gas fueled cooking appliance to stop gas flow in the set temperatures which meet NFPA standards and are UL event of system actuation. A mechanical gas valve can be Listed and FM Approved. After determining the maximum used with the Model MCH3 control head. tt is connected to ambient temperature at the thermal detector location. select the system control head by stainless steel cable. This cable the correct thermal detector according to the temperature is enclosed in 1/2" EMT with a corner pulley at each change condition chart below: in direction. The valves are rated for natural and LP gas (see Figure 2-13). Mechanical gas valves are available in Thermal the following sizes: Detector Maximum Ambient Model No. Temperature Part Number Maximum TD -225 155° F. (68` C.) 13976 Valve Operating TD -325 255° F. (124° C.) 13975 Model No. Size Pressure Par: Number TD -450 380° F. (193- C.) 13974 GV -75 3/4" 5 psi 550593 TD -600 530° F. (277° C.) 13971 GV -100 1" 5 psi 550594 GV -125 1-1/4" 5 psi 550595 MODEL RPS -M - REMOTE GV -150 1-1/2" 5 psi .550596 MECHANICAL PULL STATION GV -200 2° 5 psi 551049 PSN 551 X74 GV -250 2-1/2" 5 psi 550185 GV -300 3" 5 psi 550186 Remote manual control for the Model MCH3, NMCH3, or ECH3 control head is provided by the Model RPS -M remote mechanical pull station. It is connected to the system control head by stainless steel cable. This cable is enclosed in 1/2" ULEX 3470 October 1, 2001 PN551274 Chapter 2 — Components . Page 2=7 CORNER -PULLEYS.- 1. Model SBP -1 '(P/N 415670). A corner pulley is used whenever a change in stainless steel mac. o o cable direction is required. The Model SBP -1 corner pulley is Pyro Cheap equipped with a set screw fitting for connection to 1/2" EMT, c,As vuve sHUT oFF -See Figure 2-14.. .. _ . . 0 o /nn� Figure 2-13. GV -Series Mechanical Gas Valve 002853PC 2. Electric Gas Shutoff Valve. A gas shutoff valve is required on all systems used to pro- tect a gas fueled cooking appliance to stop gas flow in the event of system actuation. A UL Listed electric gas valve can be used with either the Model MCH3 or ECH3 control head. The valves are rated for natural and LP gas. Valves are available in 120 VAC. Electric gas valves are available in the followino sizes: Note: A UL Listed manual reset relay is required when using an electric gas valve. The Pyro-Chem Kitchen Knight II Model SM -120 solenoid monitor may be used for this pur- pose. Figure 2-14. Model SBP -1 Corner Pulley. 000,60 2. Model CBP-1 (P/N 423250). A corner pulley is used whenever a change in stainless cable .direction is required. The Model CBP-1 is a grease - tight corner pulley designed for areas likely to experience excessive deposit build-up. It is equipped with a compres- sion fitting for connection to 1/2" EMT. See Figure 2-15. Note: The Model CBP-1 is not a liquid tight seal for penetra- tion of hoods and/or ducts. Figure 2-15. Model CBP-1 Corner Pulley. 000161 3. Model WBP-1 (P/N 550982). A corner pulley is used whenever a change in stainless cable direction is required. The Model WBP-1 is a weather- proof corner pulley designed for areas likely to be exposed to moisture. It is equipped with female pipe threads for con- nection to 1/2" rigid conduit. See Figure 2-15a. Figure 2-15a. Model WBP-1 Corner Pulley. 000,6, ULEX3470 PN551274 October 1, 2001 Maximum Valve Operating Model No. Size Pressure Part Number EGVSO-75 3/4" 50 psi 550358 EGVS0-100 1'• 25 psi 550350 EGVSO-125 '1-1/4" 25 psi 550360 EGVSO-150 1-1/2" 25 psi 550361 EGVSO-200 2" 25 psi 550362 EGVSO-250 2-1/2" 25 psi 550363 EGVSO-300 3" 25 psi 550385 Note: A UL Listed manual reset relay is required when using an electric gas valve. The Pyro-Chem Kitchen Knight II Model SM -120 solenoid monitor may be used for this pur- pose. Figure 2-14. Model SBP -1 Corner Pulley. 000,60 2. Model CBP-1 (P/N 423250). A corner pulley is used whenever a change in stainless cable .direction is required. The Model CBP-1 is a grease - tight corner pulley designed for areas likely to experience excessive deposit build-up. It is equipped with a compres- sion fitting for connection to 1/2" EMT. See Figure 2-15. Note: The Model CBP-1 is not a liquid tight seal for penetra- tion of hoods and/or ducts. Figure 2-15. Model CBP-1 Corner Pulley. 000161 3. Model WBP-1 (P/N 550982). A corner pulley is used whenever a change in stainless cable direction is required. The Model WBP-1 is a weather- proof corner pulley designed for areas likely to be exposed to moisture. It is equipped with female pipe threads for con- nection to 1/2" rigid conduit. See Figure 2-15a. Figure 2-15a. Model WBP-1 Corner Pulley. 000,6, ULEX3470 PN551274 October 1, 2001 E :Chapter. 2 –,Components ' Page 2-8 i TEE PULLEY (P/N 550166) ELECTRICAL SWITCHES y'.i .. . The Mdtlel TP'-1'tee pulley �is-used to connect twe mc'chani- Tf e e,•lectrical switches 'are intended for use with electric gas cal, gas valves or two' remote mecnanical'pull stations to a valves, alarms,, contactors, lights, contractor supplied elec single control heath The tee pulley replaces two standard tric power--shut;off.devices and other electrical devices that . k—corner pulleys See Figure 2716:., .-b—are, designedto shut off, or turn on when the system is . , } actuated. T1. N The Tee Pulley must'never be used to connect'multiple fusible link lines to a single -control head. Figure 2-16. Model TP -1 Tee Pulley. 002E57PC ULEX 3470 October 1, 2001 PN551274 Switches are available in kits: One Switch Kit, Part No.. 551154; Two Switch Kit, Part No. 551155: Three Switch Kit. Part No. 551156. and Four Switch Kit. Part No. 551157. Each switch has a set of single -pole, double -throw contacts rated at 21 amp, 1 HP, 125, 250, 277 VAC or 2 HP, 250. 277 VAC. Mounting hardware and 12" wire assemblies are pro- vided with each kit. N.C. (ELACK) C. IROWN) Figure 2-17. Model MS-SPDT Miniature Switch. 001612 ;.Chapter 2.- Components Page 2-9 MODEL SM -120/24 SOLENOID NOZZLES TMONITOR _: .Nozzles have been developed for appliance, plenum, and 'The Model SM -120/24 solenoid monitor is used.,kconjunc� duct applications_. All nozzles have a specific flow. point value tion with the Model ECH3 co t`rol head to supervise the and are supplied with blow-offcaps to prevent clogging: actuation and: detection circuits.'In the event of as=problem,in Each nozzle is.stamped with the model number. See Figure the circuit, a light on the mdnitor,goes out. The Model ,SM 2-1,9. Application limitations are provided in the design sec 120 is used with the Model ECH3-120 control head. The tion of this manual. Model SM724 (P/N.550303) is used with the'Model ECH3-24 Part No. Description_ Flow No. controls head: Two sets of NO/NC dry contacts 'are-provid"ed: 551029 1 H •Noizles, pack of ten (10) i The unit mounts directly to a three gang wall outlet box. The 551026 1 L Nozzles, pack of ten (10) 1 Model SM -120 (P/N 550302) acts as a reset relay when 551028 2H Nozzles, pack of ten (10) 2 used with an electric gas valve. Electric gas valve wiring 551027 2L Nozzles, pack of ten (10) 2 instructions are provided in the installation section of this 551038 2D Nozzles, pack of ten (10) 2 manual. See Figure 2-18. e e � - Pyro-CnP.T 5«snow MCn.�« .. STRAINER E' G i BODY Figure 2-18. Model SM -24/120 Solenoid Monitor, 00286OPC' PIPE AND FITTINGS Pipe and fittings must be furnished by the installer. Schedule 40 stainless steel, chrome plated. or black pipe and fittings must be used. Galvanized pipe and fittings are not to be used. O-RING YRC 2H CAP x 20 ■ Figure 2-19. 006171pc SWIVEL ADAPTOR (P/N 423572) The Swivel adaptor consists of a swivel nut, swivel body, and swivel ball. All are chrome -plated. The swivel adaptor allows the nozzle to be rotated approximately 301 in all directions. Swivel Adaptors must be ordered as a Swivel Adaptor Shioping Assembly, Part No. 423572, which con- tains 25 swivel adaptors. See Figure 2-20. 1- 30, ROTATION Figure 2-20 000003 3/8 - 18 NPT FEMALETHREAD ULEX 3470 PN551274 bctober 1, 2001 ray t 1 Chapier 2 - Components ULEX 3470 October 1, 2001 PN551274 OMPONENTS LIST PART NO. DESCRIPTION ;MODEL.,NO. PART NO. "'PCL 300 3.0GALLON CYLINDER ASSEMBLY =;.PCL -460 4.6 GALLON, CYLINDER. ASSEMBLY 'PC.Lr600..: : 6.0 GALLON CYLINDER ASSEMBLY . PAG-10—PNEUMATIC ACTUATING CYLINDER PCL -300 CANADIAN - 3.0 GALLON MECHANICAL GAS SHUT-OFF CYLINDER ASSEMBLY. PCL 1450_'' CANADIAN - 4'.6 GALLON VALVE.3/4 CYLINDER ASSEMBLY' PCL -600. CANADIAN - 6.0 GALLON MECHANICAL GASSHUT: ,FF , CYLINDER ASSEMBLY PAC -10 CANADIAN - PNEUMATIC VALVE 1" ACTUATING CYLINDER MS -1 MOUNTING BRACKET (FOR PCL -600) MB -i5 MOUNTING BRACKET - (FOR PCL -300/460) MB -P2 MOUNTING BRACKET m (FOR MCH3 ECH3-24/120) MCH3 MECHANICAL CONTROL HEAD NMCH3 MECHANICAL CONTROL HEAD (NO HANDLE) EN-MCU3 ENCLOSURE.(FOR PRIMARY MECHANICAL GAS SHUT-OFF CYLINDER) EN -S ENCLOSURE (FOR SECONDARY VALVE 1-1/2" CYLINDER) ECH3-24 24VDC ELECTRICAL CONTROL HEAD ECH3-120 120VAC ELECTRICAL CONTROL HEAD 1 WET NOZZLE (PACK OF 10) 1 L WET NOZZLE (PACK OF 10) 2H WET NOZZLE (PACK OF 10) 2L WET NOZZLE (PACK OF 10) 2D WET NOZZLE (PACK OF 10) - - - SWIVEL ADAPTOR (PACK OF 25) RPS -M REMOTE MECHANICAL PULL STATION FLK -1 10 FUSIBLE LINK BRACKET KIT FLK -1A 8 FUSIBLE LINK BRACKET KIT =1H-25 25 x FUSIBLE LINK HANGER FL -165 FUSIBLE LINK 165'F FL -212 FUSIBLE LINK 212'F FL -280 FUSIBLE LINK 280'F FL -360 FUSIBLE LINK 360'F FL -450 FUSIBLE LINK 450'F FL -500 FUSIBLE LINK 503FF SM -21 24VDC SOLENOID MONITOR SVI-120 1,20VAC SOLENOID MONITOR TD -225 THERMALDETECTOR 225'F TD -325 THERMAL DETECTOR 325'F TD -450 THERMAL DETECTOR 450'F TD -600 THERMAL DETECTOR 600'F EGVSO-75 ELECTRIC GAS SHUT-OFF VALVE 3/4" EGVSO-100 ELECTRIC GAS SHUT-OFF VALVE 1" EGVSO-125 ELECTRIC GAS SHUT-OFF DOUBLE THROW VALVE 1-1/4" EGVSO-150 ELECTRICGAS SHUT-OFF VALVE 1-1/2" EGVSO-200 ELECTRIC GAS SHUT-OFF VALVE 2" EGVSO-250 ELECTRIC GAS SHUT-OFF 551203 VALVE 2-1/2" ULEX 3470 October 1, 2001 PN551274 OMPONENTS LIST PART NO. ,MODEL NO. DESCRIPTION . PART NO. 551194 EGVSO-300,, ,ELECTRIC,�AS SHUT-OFF VALVE 3" 550385 551193 GV -75, MECHANICAL GAS SHUT-OFF 550593 . 551196 VALVE.3/4 550104 GV -100 :` . MECHANICAL GASSHUT: ,FF , 550594 VALVE 1" 551195 GV -125 MECHANICAL GAS SHUT-OFF 550595 m VALVE 1 ,1/4" 551192 GV -150. MECHANICAL GAS SHUT-OFF 550596 VALVE 1-1/2" 551191 GV -200 MECHANICAL GAS SHUT-OFF 551049 VALVE 2" 551125 GV -250 MECHANICAL GAS SHUT-OFF 550185 VALVE 2-1/2" 550053 GV -300 MECHANICAL GAS SHUT-OFF VALVE 3" 550186 550054 MS-SPDT MINI SWITCH - SINGLE POLE 551154 DOUBLE THROW 550853 MS-DPDT MINI SWITCH - DOUBLE POLE 551,155 ' DOUBLE THROW 551200 MS-3PDT MINI SWITCH - 3 POLE DOUBLE 551156 551203 THROW MS-4PDT MINI SWITCH - 4 POLE DOUBLE 551157 551208 THROW CO2 -6 6 x CO2 CARTRIDGE 551059 550966 CEP -1 COMPRESSION BEARING 423250 CORNER PULLEY 551201 SBP_l SCREW BEARING CORNER PULLEY 415670 551202 WBP-1 WEATHER PROOF BEARING 550982 551029 CORNER PULLEY 551026 TP -1 TEE PULLEY 550166 551028 - - - WET VALVE CAP 550831 551027 - _ - CONICAL SPRING (WET VALVE) 550705 551038 - - - PRESSURE GAGE (WET VALVE) 550713 423572 - _ _ PRESSURE REGULATOR ASSEMBLY 550985 ;;51074 - - - WET VALVE REBUILDING KIT 550698 5501131 - - - PRESSURE REGULATOR REBUILD KIT 551061 550132 VT -1 VALVE TOOL (WET VALVE) 550788 550876 - _ _ NECK 0 -RING (WET VALVE) 550716 550368 _ _ _ PISTON (WET VALVE) 550707 550365 - - - PISTON O-RING (WET VALVE) 550715 550366 _ _ _ VALVE CAP C -RING (WET VALVE) 550714 550009 PCL -300 3.0 GALLON RECHARGE" 551188' 550367 PCL -300T TEST TANK 551024 56816 PCL -460T TEST TANK 550902 550303 PCL -600T TEST TANK 550901 550302 _ _ - 10 x WET NOZZLE CAP 551528 13976 _ _ - 10 x WET NOZZLE STRAINER 551529 13975 _ - - 10 x WET NOZZLE 0 -RING 551530 13974 _ _ _ VALVE STEM 0 -RING 550028 13971 - - - COMPLETE WET VALVE ASSEMBLY 551 175 550358 PCL -AK RECHARGE ADAPTOR KIT 551240 550359 - _ _ MEASURING STICK 551039 550360 WR -100 CRIMPS (100 PER PACKAGE) 550122 - - - FLUSHING SOLUTION (32 -OZ.) 79656 550361 550362 550363 1 1. CHAPTER III SYSTEM DESIGN This section will cover the proper design of the Pyro-Chem w; Kitchen Knight II Restaurant Fire Suppression System. It is `divided -into three (3) sections: - Nozzle Coverage and Placement • Piping Limitations Detector Requirements — as IN. Each of these sections must be completed before attempting INTO DUCT any installation. 20 NO LE NOZZLE COVERAGE AND PLACEMENT This section will provide guidelines for determining nozzle type, positioning, and quantity for duct, plenum, and appli- ance protection. A. Duct Protection It is not required that the fan be shut down or the exhaust duct be dampered for the system to operate properly. Each nozzle is approved to protect exhaust ducts of unlimited length. Duct protection requires that a nozzle by positioned to dis- charge up, into the duct. The nozzle is a Model 2D, Part No 551038. The Model 2D duct nozzle is a two (2) flow nozzle. A single 2D nozzle is capable of protecting square or rectangular duct with a maximum of 100 in. perimeter, with the loneest side being a maximum of 34 in. It can also protect a round duct with a maximum diameter of 31 7/8 in' Two (2) Model 2D duct nozzles can protect a square or rec- tangular duct with a maximum of 150 in. perimeter, with the longest side being a maximum of 51 in. They can also pro- tect a round duct with a maximum diameter of 47 1/2 in. When two (2) 2D duct nozzles are used to protect a single duct, the cross sectional area of the duct must be divided into two equal symmetrical areas. The nozzle must then be installed on the centerline of the area it protects and aimed directly into the duct opening. The nozzle(s) must be installed on the centerline of the duct, with the tip located 0 to o in. into the opening, and aimed directly into the duct opening. See Figure 3-1. Chapter 3 System Design ., ..,,Page 3-1 112 w I i 1v2 L ----i I --•' Figure 3-1. Transition Ducts - The protection of non-standard ducts should be reviewed by the authority having jurisdiction. Pyro-Chem Kitchen Knight II recommends that transition ducts be protected as follows: a. Transition ducts - larger to smaller In cases where the duct/plenum interface opening is larger than the final exhaust duct. measure the perime- ter/diameter of the duct halfway between the largest and smallest section (or the average perimeter/diame- ter). The nozzle is to be located within -0-6 in. of the duct/plenum interface (not at the point where the mea- surement was taken). centered under the final exhaust duct opening. See Figure 3-1 a., PERIMETER- - - MEASUREMENT Figure 3-1 a. 006173PC N INTO ;ITION ULEX 3470 PN551274 October 1, 2001 Chapter'3 =System Design Page 3-2 b. Transition ducts - smaller to larger B. Plenum Protection jn cases,,,uhere the duct/plenum,interface opening isThE-Model 1H nozzle, PartN6,,-55j1.029,j.js,a_one (1.) flow,_, I ,,,<- ;Ismaller than tWfinal exhaust duct, measure the : nozzle used ,for plenum.; rote'ction. A single 1 H nozzle can perimeter/diameterlof the final exhaust duct. The noz protect a plenum (with singie or V -bank filters) 10 ft. long by z �,(s) is. - be located within 0-6 in. of the duct/plenum 4 ft: wide. Dividing the length' ,to sections equal to or less int erface;,'centered in the opening. See Figure 3-1 b: than 10 ft: in length" and'pbsitioning a nozzle at the staff of each section can be done top rotect longer plenums. PERIMETER' — -i — On V -bank plenums-the.noz2ie(s must'be located at the cen- MEASUREM,ENT ,. _ ter of the V -bank width,- 1/3 of the vertical height Of the filters. On single filter bank plenums. the nozzle must be located 2 in. from the back edge of the filter,' 1/3 down from the vertical height. For either application, the -nozzle must be located with- \' / in 6 in. of the end of the plenum (or module) and aimed direct- ly down the length of the plenum. See Figure 3-2. i I I / I Figure 3-1 b c. Multiple risers In cases of multi pie rises. each riser is protected as an individual duct. See Figure 3-1 c. DUCT T_ I k DUCT I I , � I R\ ao6:>s=c PLENUM Figure 3-1 c Electrostatic Precipitator — Ducts utilizing electrostatic pre- cipitators must be protected above and below the unit. Standard duct nozzles are used in this application. See Figure 3-1d. 2D NOZZLE -�-- PRECIPITATOR PLENUM 2D NOZZLE Mwi 7r.Pc Figure 3-1 d ULEX 3470 October 1, 2001 PN551274• �— 1,2 W 1 I V -BANK SINGLE BANK Figure 3-2 006 17'hPC s Chapter 3'— System Design - Page 3-3 C. Appliance Protection 1a. Fryers without Drip Board (19 in. x 19 1/2 in. maximum) ,Ngte-;When. protecting appliances which are larger than sin- o Two nozzles areava'ita,bre, f'6 '1ryer protection: High prox ,r le nozzle coverage, multiple nozzles can be used. imity and low p• r`bxlmity. ,Larger appliances can be divided into several modules, each The Model 2H nozzle,,,, Part No. 551028, is used for high equal to' or smaller than single nozzle coverage. Exception: proximity. fryer protection: TFiis nozzle is a two (2) flow Fryers must not. exceed a maximum of 864 sq. in. nozzle. The nozzle must be located anywhere within For modularizing fryers, refer to,"FRYER – MULTIPLE NOZ- the perimeter of,the.hazard area, 24 in. to 48 in, above ZLE PROTECTION".. the cooking surface of.the appliance and aimed at the center of the cooking area. See Figure 3-3a. Design Chart The Model 2L nozzle is used for low proximity fryer protec- tion. This nozzle is a two (2) flow nozzle. The nozzle must Maximum Cooking be located anywhere on the perimeter of the hazard Appliance Type Hazard Area per Nozzle area, 13 in, to 24 in. above the cooking surface of the Fryer 19 in. x 19 1/2 in. appliance and aimed -at the center of the cooking area. Without Drip Board maximum See Figure 3-3a. Fryer 18 in. x 27 3/4 in. maximum 2H HIGH % PROXIMITY With Drip Board 19 in. x 25 3/8 in. maximumNOZZLE / LOCATED Two Burner Range 12 In. x 28 in.. maximum ANYWHERE Four Burner Rance 28 in. x 28 in. maximum i S j WHIN THE IT I r 2H.2L PERIMETER Small Wok 24 in. diameter x >— Low ' sE' ; ; i PROXIMITY ,r 6 in. deep maximumLOCATED NOZZI E 2L I ' ANYWHERE L za Large Wok 30 in. diameter x THE !� PERIMETER 8 in. deep maximum13' 3 Small Griddle Maximum area of 1080 sq. •�`-1 in. with the longest side to FRYERS WITHOUT be a maximum of 36 in. '�_ EDGE OF DRIPSOARDS HAZARD Large Griddle Maximum area of 1440 sq. I- of I ---- -- AREA I HAZARD in. with the longest side to AREA M6170P-- be a maximum of 48 in. Figure 3-3a Gas Radiant Char -Broiler Maximum area of 624 sq. in. with the longest side to be a 1 b. Fryers with Drip Board maximum of 26 in. The maximum single nozzle protection dimensions Gas Radiant Char -Broiler Maximum area of 864 sqin. depend on the dimensions of the fry pot only. with the longest side to be a For fry pots with maximum dimensions of 18 in. on the maximum of 36 in. longest side and 324 sq. in. max. area, use overall Lava Rock Char -Broiler Maximum area of 624 sq. in. dimensions of 27 3/4 in. on the longest side and 500 sq. with the longest side to be a in. max. area. maximum of 26 in. For fry pots with maximum dimensions exceeding 18 in. Natural Charcoal Broiler Maximum area of 480 sq. in. x 324 sq. in., but no greater than 19 1/2 in. on the with the longest side to be a loncest side and 371 sq. in. max area, use overall maximum of 24 in. dimensions of 25 3/8 in. on the longest side and 495 sq. Mesquite Char -Broiler Maximum area of 480 sq. in. in. area. with the longest side to be a Two nozzles are available for fryer protection: High prox- maximum of 24 in. imity and low proximity. Upright/Salamander Broiler 36 in. wide x 28 in. deep maximum Chain Broiler 27 in. wide x 38 in, deep maximum ULEX 3470 PN551274 October 1, 2001 Chapter:3'..System-Design rc ' Page .3=4 . The Model 2H nozzle, Part No. 551028, is used for high proximity fryer protection. This nozzle is a two (2) flow nozzle. The nozzle must be located anywhere.,within,y _. the perimeter of the hazard area, 24 im10 48 in. above the cooking surface of the appliance and aimed at the center df the cooking area. See Figure 3=3b. The Model 2L nozzle is used for low proximity f.ryer pro- tection. This nozzle is a two (2) flow nozzle. The nozzle must be located anywhere on the perimeter of. the haz- ard area, 13 in. to 24 in. above the cooking surface of the appliance and aimed at the center of the cooking area. See Figure 3-3b. 2. Two Burner Range (12 in. x 28 in. maximum) Two nozzles are available for two burner range protec- tion: High proximity and low proximity. The Model 1 H nozzle, Part No. 551029, is used for high proximity two burner range'protection. This nozzle is a one (1) flow nozzle. When using high proximity pro- tection, the range cannot be under a backshelf. This nozzle must be located on both the front/back centerline and the side/side centerline of the appliance. 40 in. to 50 in. above the cooking surface. and aimed directly down. See Figure 3-4a. ULEX 3470 October 1, 2001 PN551274 1H " i 50' i I �_011 . I 28 IN. t 12 1N. / HIGH PROXIMITY 0061BOPC Figure 3-4a The Model 1 L nozzle, Part No. 551066, is used for low prox- imity two burner range protection. This nozzle is a one (1) flow nozzle. The range can be equipped either with or with- out a backshelf. Either type requires the same nozzle requirements. The nozzle must be located 22 in. from the end of the hazard area centered from left to right. It must be 13 in. to 24 in. above cooking surface, and aimed at a point one half the distance of whatever the height dimension of the nozzle is. When determininc nozzle and aim point loca- tions. both measurements are to be taken from the same end of the hazard area. Example: The nozzle is mounted 20 in. above the cooking surface. The aim point from the edge of the hazard would then be 10 in. which is one half the nozzle mounting height dimension. See Figure 3.4b. Note: If the range contains a backshelf, it must be a minimum of 23 1/2 in. above the surface of the appliance and cannot extend over the hazard area more than 11 in. EDGE OF HAZARD AREA I 2,.. IL �\ is 22- 1L 2e (H) 13 (H) ,121 1 \ (,H) HAZARD "uuPc l ' 1/2 (H) ^ SURFACE Figure 3-4b t C� 2H HIGH i PROXIMITY NOZZLE " LOCATED I , ANYWHERE WITHIN THE ' PERIMETER 2H. 2L Kms" i tea`_ LOW 48- ...� f i PROXIMITY ' NOZZLe LOCATED / 2L; ANYWHERE / L 24•• ON THE i PERIMETER ' 006230PC FRYERS WITH ��-- EDGE of DIPBOARDS OF I HAZARD - - - AREA 'HAZARD AREA OW78Pc Figure 3-3b 2. Two Burner Range (12 in. x 28 in. maximum) Two nozzles are available for two burner range protec- tion: High proximity and low proximity. The Model 1 H nozzle, Part No. 551029, is used for high proximity two burner range'protection. This nozzle is a one (1) flow nozzle. When using high proximity pro- tection, the range cannot be under a backshelf. This nozzle must be located on both the front/back centerline and the side/side centerline of the appliance. 40 in. to 50 in. above the cooking surface. and aimed directly down. See Figure 3-4a. ULEX 3470 October 1, 2001 PN551274 1H " i 50' i I �_011 . I 28 IN. t 12 1N. / HIGH PROXIMITY 0061BOPC Figure 3-4a The Model 1 L nozzle, Part No. 551066, is used for low prox- imity two burner range protection. This nozzle is a one (1) flow nozzle. The range can be equipped either with or with- out a backshelf. Either type requires the same nozzle requirements. The nozzle must be located 22 in. from the end of the hazard area centered from left to right. It must be 13 in. to 24 in. above cooking surface, and aimed at a point one half the distance of whatever the height dimension of the nozzle is. When determininc nozzle and aim point loca- tions. both measurements are to be taken from the same end of the hazard area. Example: The nozzle is mounted 20 in. above the cooking surface. The aim point from the edge of the hazard would then be 10 in. which is one half the nozzle mounting height dimension. See Figure 3.4b. Note: If the range contains a backshelf, it must be a minimum of 23 1/2 in. above the surface of the appliance and cannot extend over the hazard area more than 11 in. EDGE OF HAZARD AREA I 2,.. IL �\ is 22- 1L 2e (H) 13 (H) ,121 1 \ (,H) HAZARD "uuPc l ' 1/2 (H) ^ SURFACE Figure 3-4b t C� 3. Four Burner Range (28 in. x 28 in. maximum) One nozzle is available for four burner range protection: High proximity. The Model 2L nozzle, Part No. 551027, is used for high proximity four burner range protection. This nozzle is a two (2) flow nozzle. When using high-proximity.pro- tection, the range cannot be under a backshelf. This nozzle -must be located on both the front/back centerline and the side/side centerline 'of"the hazard area, 34 in. to 48 in. above the cooking surface, and aimed directly down. See Figure 3-5. 2L i 48" 00616z—� Figure 3-5 4. Small Wok (24 in. diameter x 6 in. depth maximum) Two nozzles are available for "small wok protection: High proximity and low proximity. The 1H nozzle, Part No. 551029, is used for high prox- imity wok protection. This nozzle is a one (1) flow noz- zle. The nozzle must be located anywhere on the perimeter of the appliance, 24 in. to 48 in. above the top edge of the wok and aimed at the center of the wok. See Figure 3-6. The 1 L nozzle, Part No. 551026, is used for low proximity wok protection. This nozzle is a one (1) flow nozzle. The nozzle must be located anywhere on the perimeter of the appliance, 13 in. to 24 in. above the top edge of the wok and aimed at the center of the wok. See Figure 3-6. Chapter"3' System Design Page"3-51 ' ISH ,I iH, 1L 48" , I ,L } 2a 13 Ire.' NOZZLE LOCATED ON PERIMETER ao6ra0PC 24 IN. DIAMETER MAXIMUM Figure 3-6 Large Wok (Greater than 24 in. to 30 in. diameter x 8 in. depth maximum) Two nozzles are available for large wok protection: Hiah proximity and low proximity. The 2H nozzle, Part No. 551028, is used for high prox- imity wok protection. This nozzle is a two (2) flow nozzle. The nozzle must be located anywhere on the perimeter of the appliance, 24 in. to 48 in. above the top edge of the wok and aimed at the center of the wok. See Figure 3-7. The 2L nozzle, Part No. 551027, is used for low proximity wok protection. This nozzle is a two (2) flow nozzle. The nozzle must be located anywhere on the perimeter of the appliance, 13 in. to 24 in. above the top edge of the wok and aimed at the center of the woks See Figure 3-7. 12H rT I , I , I ;I ! 2H. 2L I—� 48' ' l 2L za- , NOZZLE LOCATED ON PERIMETER 0061e0vc 30 IN. DIAMETER MAXIMUM Figure 3-7 ULEX 3470 PN551274 October 1, 2001 i 12L I I 34" /I\ 28 IN. 28 IN, I 00616z—� Figure 3-5 4. Small Wok (24 in. diameter x 6 in. depth maximum) Two nozzles are available for "small wok protection: High proximity and low proximity. The 1H nozzle, Part No. 551029, is used for high prox- imity wok protection. This nozzle is a one (1) flow noz- zle. The nozzle must be located anywhere on the perimeter of the appliance, 24 in. to 48 in. above the top edge of the wok and aimed at the center of the wok. See Figure 3-6. The 1 L nozzle, Part No. 551026, is used for low proximity wok protection. This nozzle is a one (1) flow nozzle. The nozzle must be located anywhere on the perimeter of the appliance, 13 in. to 24 in. above the top edge of the wok and aimed at the center of the wok. See Figure 3-6. Chapter"3' System Design Page"3-51 ' ISH ,I iH, 1L 48" , I ,L } 2a 13 Ire.' NOZZLE LOCATED ON PERIMETER ao6ra0PC 24 IN. DIAMETER MAXIMUM Figure 3-6 Large Wok (Greater than 24 in. to 30 in. diameter x 8 in. depth maximum) Two nozzles are available for large wok protection: Hiah proximity and low proximity. The 2H nozzle, Part No. 551028, is used for high prox- imity wok protection. This nozzle is a two (2) flow nozzle. The nozzle must be located anywhere on the perimeter of the appliance, 24 in. to 48 in. above the top edge of the wok and aimed at the center of the wok. See Figure 3-7. The 2L nozzle, Part No. 551027, is used for low proximity wok protection. This nozzle is a two (2) flow nozzle. The nozzle must be located anywhere on the perimeter of the appliance, 13 in. to 24 in. above the top edge of the wok and aimed at the center of the woks See Figure 3-7. 12H rT I , I , I ;I ! 2H. 2L I—� 48' ' l 2L za- , NOZZLE LOCATED ON PERIMETER 0061e0vc 30 IN. DIAMETER MAXIMUM Figure 3-7 ULEX 3470 PN551274 October 1, 2001 .Y Chapter 3 System,.Design Page 3-6 6. Small Griddle (1080 sq. in. x 36 in. longest side and 12 in. in from the corner below the nozzle. See maximum) Figure 3-9. Two nozzles are available for small griddle protection. EDGE OF. High proximity and low proxi"'" mity ��� HAZARD AREA / NOZZLE (ANY The 1H -nozzle, Part No. 551029, is used for high-.proxim- CORNER) 72- ity griddle protection. This nozzle is a .one (1) flow nozzle. ° ....., The nozzle must be located above any corner of'the 72.` - hazard surface, 24 in. to 48 in. above the cooking surface AIM POINT of the appliance and aimed at a point 12"in. over and 12 in, in from the corner below the nozzle. See Figure 3-8. 2H ! The 1 L nozzle, Part No. 551026, is used for low proximity griddle protection. This nozzle is a one (1) flow nozzle. T' I The nozzle must be located above any corner of the , hazard surface, 13 in. to 24 in. above the cooking surface 2H 2, of the appliance and aimed at a point 12 in. over and 12 in. in from the corner below the nozzle. See Figure 3-8. ;e• EDGE OF 21- / HAZARD AREAZC T* HAZARD SURFACE 7 NOZZLE (ANY -► CORNER) 12•' I ,2"\ i r: t ' .HAZARD 24.. ` SURFACE I AIM POINT Figure 3-8 Large Griddle (1440 sq. in. x 48 in. longest side maximum) Two nozzles are available for large griddle protection: High proximity and low proximity. The 2H nozzle, Part No. 551028, is used for high prox- imity griddle protection. This nozzle, is a two (2) flow noz- zle. The nozzle must be located above any corner of the hazard surface, 24 in. to 48 in. above the cooking surface of the appliance and aimed at a point 12 in. over and 12 in. in from the corner below the nozzle. See Figure 3-9. The 2L nozzle, Part No. 551027, is used for low proximi- ty griddle protection. This nozzle is a two (2) flow nozzle. The nozzle must be located above any corner of the hazard surface, 13 in. to 24 in. above the cooking sur- face of the appliance and aimed at a point 12 in, over ULEX 3470 October 1, 2001 PN551274 8 I — Figure 3-9 Gas Radiant Char -Broiler (624 so. in. x 26 in. longest side maximum) Two nozzles are available for gas radiant char -broiler Protection. High proximity and low proximity. The 1 H nozzle. Part No. 551029. is used for high Droximity gas radiant char -broiler protection. This nozzle is a one (1) flow nozzle. The nozzle must be located anywhere within the perimeter of the hazard area. 24 in. to 48 in. above the cooking surface of the appliance and aimed at the center of the broiler surface. See Figure 3-10. The 1L nozzle, Part No. 551026, is used for low proximity gas radiant char -broiler protection. This nozzle is a one (1) flow nozzle. The nozzle must be located anywhere on the perimeter of .the hazard surface, 13 in. to 24 in. above the cooking surface of the appliance and aimed at the center of the broiler surface. See Figure 3-10. ,H NOZZLE LOCATED ANYWHERE WITHIN THE PERIMETER FOR HIGH PROXIMITY PROTECTION IHL IL NOZZLE LOCATED ANYWHERE ON THE PERIMETER FOR LOW ,H. 1L PROXIMITY I PROTECTION 48" L, !li GAS RADIANT oa6187Pc BROILER EDGE: OF HAZARD AREA Figure 3-10 4 9 Gas Radiant Char -Broiler (864 sq. in. x 36 inJongest side maximum) Two nozzles are available for gas radiant-6tva'r='6foilefv"�--I' protection: High proximity and, low prozimrty. The 2Ft•nozzle, Part No. 551028, is used for,14igh prox- imity gas radiant char -broiler protection. This noizleis a.. two (2) flow nozzle. The nozzle must be located above any corner of the hazard surface, 36 in. to 48 in. above S,7chapter-3'=System Design Page 3-7 The 2L.nozzle, Part No. 551027, is used for low proximi- ty lava rock char -broiler protection. This nozzle is a two (2) flow nozzle. The nozzle must. be located anywhere on the perimeter of the hazard surface, 15 in:-to•2.4-in,.- above the cooking surface of .the appliance and aimed at the center of the broiler surface. See Figure 3-12. 2L NOZZLE LOCATED ANYWHERE WITHIN THE PERIMETER 2L FOR HIGH PROXIMITY PROTECTION �1 2L NOZZLE LOCATED ANYWHERE ON THE PERIMETER the cookingsuae of appliance anaimed at te FOR LOW rfcf thppliand d h2L I PROXIMITY center of the broiler surface. See Figure 3-11a. ``\ PROTECTION EDGE OF 35 2L 2H NOZZLE (ANY �—� CORNER) 2H 48' 3.6 p HIGH PROXIMITY GAS 006+86ac RADIANT BROILER Figure 3-11 a The 2L nozzle, Part No. 551027, is used for low proximity gas radiant char -broiler protection. This nozzle is a two (2) flow nozzle. The nozzle must be located anywhere on the perimeter of the hazard surface, 13 in. to 36 in. above the cooking surface of the appliance and aimed at the center of the broiler surface. See Figure 3-11b. NOZZLE LOCATED ANYWHERE ALONG 2L PERIMETER OF HAZARD Ij AREA 2L 36'17 LOW PROXIMITY GAS nwuuary I MHUILtH EDGE OF HAZARD AREA Figure 3-11 b 10. Lava Rock Char -Broiler (624 sq. in. x 26 in. longest side maximum) One nozzle is available for lava rock char -broiler protec- tion. The 2L nozzle, Part No. 551027, is used for both high proximity and low proximity. The 2L nozzle, Part No. 551027, is used for high proxim- ity lava rock char -broiler protection. This nozzle is a two (2) flow nozzle. The nozzle must be located anywhere within the perimeter of the hazard area, 24 in. to 35 in. above the cooking surface of the appliance and aimed at the center of the broiler surface. See Figure 3-12. �\ 24' 1 I j CHAH-BROILER EDGE OF HAZARD AREA Figure 3-12 11. Natural Charcoal Char -Broiler (480 sq. in. x 24 in. lonaest side maximum) Two nozzles are available for natural charcoal char -broil- er protection. High proximity and low proximity. The max- imum depth of fuel (charcoal) must not exceed 6 in. The 1 H nozzle, Part No. 551029, is used for high prox- imity natural charcoal char -broiler protection. This nozzle is a one (1) flow nozzle. The nozzle must be located anywhere within the perimeter of the hazard area, 24 in. to 35 in. above the cooking surface of the appliance and aimed at the center of the broiler surface. See Figure 3-13. The 1 L nozzle, Part No. 551026, is used for low proximi- ty natural charcoal char -broiler protection. This nozzle is a one (1) flow nozzle. The nozzle must be located any- where on the perimeter of the hazard surface, 15 in. to 24 in. above the cooking surface of the appliance and aimed at the center of the broiler surface. See Figure 3-13. 1 H NOZZLE LOCATED ANYWHERE WITHIN THE PERIME- 1H TER FOR HIGH PROXIMITY PROTECTION 1L NOZZLE LOCATED ANYWHERE ON THE PERIMETER 1L, 1H ` FOR LOW PROXIMITY i PROTECTION I 3s 1L �� C 2d" + 1 15 \\`\\"'J r FUEL DEPTH MUST NATURAL CHARCOAL aoe,ernc NOT EXCEED 6- CHAR -BROILER EDGE OF Figure 3-13 HAZARD AREA ULEX 3470 PN551274 October 1, 2001 Chapter. 3; --System, Design Page 3-8 12. Mesquite Char -Broiler (480 sq. in. x 24 in. longest side maximum) s •,: "Twb"nozzles are available for mesquite char -broiler pro- tection. High proximity and low proximity. The maximum depth of fuel (wood) must not exceed 6 in. a 'rhe••1 H nozzle; Part No. 551029, is used for high proxim- ity'mesquite char -broiler protection. This nozzle is a one (1) flow nozzle. The nozzle must be located anywhere, within -the perimeter of the hazard area, 24 in. to 35 in. above -the cooking surface of the appliance and aimed at the center of the broiler surface. See Figure 3-14. The 1 L nozzle, Part No. 551026, is used for low proximi- ty mesquite charcoal char -broiler protection. This nozzle is a one (1) flow nozzle. The nozzle must be located anywhere on the perimeter of the hazard surface, 15 in. to 24 in. above the cooking surface of the appliance and aimed at the center of the broiler surface. See Figure 3-14. 1H i 1L, 1H \ 24' 1H NOZZLE LOCATED ANYWHERE WITHIN THE PERIMETER FOR HIGH PROXIMITY PROTECTION 1L NOZZLE LOCATED ANYWHERE ON THE PERIMETER FOR LOW PROXIMITY PROTECTION I FUEL DEPTH MUST NOT EXCEED 6" CHAR -BROILER Figure 3-14 ULEX 3470 October 1, 2001 PN551274 006167-C EDGE OF HAZARD AREA 13. Upright/Salamander Broiler (internal chamber 36 in. wide x 26 in. deep maximum) One nozzle is ayaila'Ste^,for'do�ight/salamander broiler -- protection.• The 1 L nozzle, Part -No. 55:1026, is used for broiler pro- tection. This nozzle is a'one•(1,) flow nozzle. The nozzle must be located above the grate, at the front edge of the appliance, and, pointed at the back opposite corner of the broiler chamber: The -nozzle must be aimed parallel to the broiler grate surface. See Figure 3-15. 1 L NC=LE AIMED AT BACK OPPOSITE CORNER 1 L NOZZLE AIMED AT BACK OPPOS17 CORNER =R RAOH FR Figure 3-15 BROILE=;. v .HAMS UPRIGHT BROILER osis9ac 14. Chain Broiler (internal chamber 27'in. wide x 38 in. s ; deep maximum) 'One- nozzle is available.for chain broiler protection.t, _. The 1 L '.nozzle, Part No. 551026, is used for broiler pro- tection. -.This nozzle is a one (1) flow nozzle. The nozzle must be located 1-3 in. above the surface of the chain, at the front edge of the appliance, and pointed at the opposite diagonal corner. The nozzle must be aimed parallel to the chain surface. See Figure 3-16. )ZZLE AIMED 'POSITE JNALCORNER Figure 3-16 Chapter 3 — System Design Page 3-9 15. Tilt Sklllet7Braising Pan' Protection for tilt skilletor braising pans is to be based upon the,co�verage Iiftfi1dtion provided for deep fat fryer _•='- proteotion:; Coverage limitations are based on fryer sizes including drip boards. Exception: Tilt skillets and braising pans may excet?d ,tfie maximum of 6 sq. ft. total when modularizing. Tilt skillets and braising pans generally uti- lize a hinged cover. Fryer protection nozzles 'are to be placed toward the front of the appliance to minimize the potential for the tilt skillet or braising pan cover to inter- fere with the nozzle discharge. See Figure 3-17. COVER MUST NOTINTERFERE WITH NOZZLE DISCHARGE THE NOZZLE IS TO BE PLACED TOWARD THE FRONT OF THE APPLIANCE TO MINIMIZE THE POTENTIAL FOR THE SKILLET OR BRAISING PAN COVER TO INTERFERE WITH THE NOZZLE DISCHARGE. COVER MUST NOT INTERFERE FOR MINIMUM WITH EDGE OF AND MAXIMUM DISCHARGE / i NOZZLE PATTERN / I HEIGHTS. REFER TO FRYER / NOZZLE PARAMETERS i Doom, c FRYER NOZZLE USED FOR TILT SKILLET OR BRAISING PAN PROTECTION MUST BE POSITIONED NEAR THE FRONT EDGE OF THE PAN AND AIMED AT THE FRONT TO BACK CENTERLINE OF THE PAN. THE DISCHARGE FROM THE NOZZLE(S) MUST COMPLETELY CLEAR THE PAN COVER WITH AN UNOBSTRUCTED VIEW TO THE BACK OF THE PAN. Figure 3-17 PN551274 ULEX 3470 October 1, 2001 Chapter 3 , �System:Design Page3-10 FRYER — MULTIPLE NOZZLE PROTECTION .Fryers eceedino.the coverage of a single nozzle can be divided into modules. Each module must not exceed the `maximum area allowed 'for a single nozzle. However, when utilizting'"multiple nozzle protection, the longest side allowed for a fryer with drip' board can be used, regardless of whether -the fryer has a drip board or not. The maximum size fryer that can be modularized is 864 sq. in. Desidn requirements for multiple nozzle fryers are broken down as follows: 1. If the fryer includes any dripboard areas, measure both the internal length (front to back) and width of the frypot portion. Then measure the internal length and width of the overall hazard area including any dripboard areas. Determine the area of both the frypot and the area of the overall vat by multiplying corresponding lenoth and width dimensions. 2. Divide the frypot or overall vat into modules, each of which'can be protected by a single nozzle. based on the maximum dimension and area coverage of the nozzle as specified in "Desion Chart." • If the module considered does not include any portion of the dripboard, use only the maximum frypot area and maximum dimension listed in the "Design Chart." • If the module considered includes any dripboard areas, use both the maximum frypot area and dimen- sion listed in the "Design Chart", and the maximum overall area and dimension listed in the "Design Chart." 3. None of the maximum dimensions may be exceeded. If either the maximum frypot or the overall sizes are exceeded. the area divided into modules will need to be redefined with the possibility of an additional nozzle. ULEX 3470 October 1, 2001 PN551274 PIPING LIMITATIONS ,,once the nozzle placement'and­quantity of tanks has.been determined-," it is necessary to determine the piping configu- rations between the tank and the nozzles. This section con- tains the guidelines and limitations for designing the distribu- tion piping so that the wet chemical agent will discharge from the nozzles at a proper flow rate. These limitations must also be referred,to when selecting the mounting loca- tion for the tanks. The maximum pipe lengths are based on internal pipe vol- ume. Each size tank is allowed a minimum and maximum total volume of piping, calculated in milliliters. There is no need to distinouish between what portion of the piping is supply line and what portion is branch line. Only the total volume of the complete piping network has to be considered. Volume Chart 1/4 in. pipe = 20.5 mis./ft. 3/8 in. pipe = 37.5 mis./ft. 1/2 in. pipe = 59.8 mis./ft. 3/4 in. pipe = 105.0 mis./ft. Tank Chart Maximum Volume Allowed Maximum Between First Maximum Pipe Nozzle and Tank Flow Volume Last Nozzle Size Numbers (milliliters) (milliliters) 3.0 Gallon 10 1910 1125 PCL -300 4.6 Gallon 14 3400 3000 PCL -460 4.6 Gallon 15 2600 2000 PCL -460 6.0 Gallon 19 4215 1688 PCL -600 per side 6.0 Gallon 20 3465 1313 PCL -600 per side General Piping Requirements 1, Split piping and straight piping are both allowed on a PCL -300 and PCL -460 system. -2.- -.PCL-600 systems must use split piping only, with no nozzle located before the split, and with a maxi- mum of 14 flow points per "side. 1/2 in. minimum - piping must be used up to the first split. 3. Maximum volume for 1 4"in. pipe between a nozzle and the preceding tee is 410 mis. 4. Maximum flow numbers for 1/4 in. pipe is 6. 5. Maximum number of elbows between a nozzle and the preceding tee is 5. 6. Maximum of 25 elbows are allowed in the total pip- ing system. i 7. Maximum difference in elevation between the tank outlet and any nozzle, or the tank outlet and the highest or lowest horizontal pipe run, is 10 it. 8. No traps are allowed in the piping network. 9. Pipe lengths are measured, from center to center of fittings. 10. The internal equivalent leh'ath volume of fittings does not have to be considered as part of the total pipe volume. j 11. When utilizing different size pipe in the system, the largest size must start first' and the additional pipe must decrease as it approaches the nozzle. l 12. Elbow(s) or swivel adaotors located at the nozzles do not have to be counted; in the 25 elbow maxi- mum requirement. 13. Reducing bushings are allowed when reducing to a smaller pipe size. 14. Additional piping requir2ments when protecting a range, wok. or a fryer: • PCL -300 - Minimum of 300 ml and four (4) flow numbers required in total system. Of that mini- mum, 239 ml and two (2) flow numbers must be utilized at or before the range, wok, or fryer. • PCL -460 — Minimum of 660 ml and ten (10) flow numbers required in total system. Of that mini- mum, 180 ml and two (2) flow numbers must be utilized at or before the range, wok, or fryer. • PCL -600 — Minimum of 960 ml and fourteen (14) flow numbers required in total system. Of that minimum, 120 ml and 2 flow numbers must be utilized at or before the range, wok, or fryer. Chapter-3.—System Design -,',`P Page -3-11' SUPPLY PIPE MUST ENTER BULL SIDE OF TEE ; 0 SPLIT PIPING Figure 3-18 Design Steps IG Step No. 1 Determine number of flow points required based on duct size, plenum size and type, and size of all appliances. Step No. 2 Determine size and quantity of tanks required. Refer to the chart in "General Piping Requirements" to determine the maximum amount of flow numbers allowed per each tank size. Step No. 3 Layout nozzles, piping diagram, and tank loca- tion. Determine pipe lengths as accurate as possible. Make certain maximum number of elbows is not exceeded. Note: Tanks cannot be manifolded together. Each tank must have a separate piping network. Step No. 4 Add all the lengths of each pipe run and multiply by the mis./ft. listed in the Volume Chart. If the sum falls within the acceptable range noted in general Piping Requirements, that pipe size is acceptable. If the calculated volume is too large, recalculate the volume using the ml per foot of a smaller pipe size. Pipe sizes can be mixed but Rule No. 11 of the General Piping Requirements must be followed. Step No. 5 Check to make certain minimum volumes, maxi- mum volumes and maximum volume allowed between first nozzle and last nozzle is not exceeded (Tank Chart). Check each rule in "General Piping Requirement" to make certain none have been exceeded. If any requirement is exceeded, change to a different pipe size and recalculate. PN551274 ULEX 3470 October 1, 2001 :;Chapter 3: -,,System :Design -Page 3-12 Example The cooking area that requires protection, consists of a sin- gle 48 in. 'perimeter exhaust dupt, art"0 ft long-'"V"'hank plenum, (2). 1.8'ih. wi`c1e7x'24'fn' fryers, a 30 in. x 36 in.. wide griddle, and. a 24 in. diameter wok. See Figure 3-19. �< ° ° Figure 3-19 (2) 18 IN. X 24 IN. FRYERS (1) 30 IN. X 36 IN. GRIDDLE (1) 24 IN. DIAMETER WOK 006192?C Step No. 1 Determine number of flow points required. • 48 in. perimeter duct requires one. two flow nozzle • 10 ft. "V" bank hood requires one. one flow nozzle • 18 in. x 24 in. fryer requires one. two flow nozzle • 18 in. x 24 in, fryer requires one, two flow nozzle , • 30 in..x 36 in. griddle requires one, one flow nozzle • 24 in. diameter wok requires one. one flow nozzle TOTAL FLOW NUMBERS — 9 Step No. 2 Determine size and quantity of tanks required. Referring to the chart in "General Piping Requirements", a PCL -300 and a PCL -460 can supply 10 flows, therefore, a PCL -300 can be utilized. ULEX 3470 October 1, 2001 PN551274 YV; Step No. 3 Make an accurate sketch of the cooking lineup and the hood. Sketch in the tank location and all the piping required for the total system. Make certairi all pipe lengths and number of elbows' . , are as accurate as possible. Check the "General Piping Requirements to determine that the minimum and maximum requirements are met. See Figure 3-20. 14 I2' Figure 3-20 � \` - C' � Step No. 4 Total all pipe lengths. Refer to the Volume Chart. Chose a given.pipe size and multiply the mi per .~.. by the total lenq�t of all the pipe. If the sum falls with ' itrii;�'acc.eptable'range noted In 'rli-nk-tha'ri, that Pipe size is a 9 ..calculated volume is cceptable. If the ,too large, recalculate the volume using the mi size. Soo Figure 3'2` -- smaller�p~ Add section A-B=O�6 +5;+14'+2'+O' -O =22' Add section B -C= Add section C -D= 1' ` Add section D -E= 2' � Add section E'F=O''O' Add section F -L= 3'+2'+2^ =7' Add section B+G =U' - *ooaectinnC'H=2'+2'=4' Add section D'| =2'+ '= 4' Add section E'J=O'~5,+O''G^= 1' Add section F'K=2'+4' Tota/ length of all pipe 47'-6" D 2 i � � z s | — .. '*.� unap�r3—Syo�m'Page 3-13 ' Refer toVolume Chart. The pipe size chosen 'is 30 inch. The'vo|ume per foot of 3/8 in. 3�6mi. Wuk���75by�e��]p�e - \- 47.5 ML `m�`. � ~~' '~— — 37.5 m| x 475 ft. = 1781 m| total volume The mox��um volume . hr ^^ allowed a�CL�0� 1910 m|. Uhenehona. 30 in. pipe is acceptable for this 'system. ` ' L Figure 3-21 UILEX 3470 pw551274 October 1.20O1 ' � A � Tm |— z s | — .. '*.� unap�r3—Syo�m'Page 3-13 ' Refer toVolume Chart. The pipe size chosen 'is 30 inch. The'vo|ume per foot of 3/8 in. 3�6mi. Wuk���75by�e��]p�e - \- 47.5 ML `m�`. � ~~' '~— — 37.5 m| x 475 ft. = 1781 m| total volume The mox��um volume . hr ^^ allowed a�CL�0� 1910 m|. Uhenehona. 30 in. pipe is acceptable for this 'system. ` ' L Figure 3-21 UILEX 3470 pw551274 October 1.20O1 ' � Chapter 3'7 System Design Step No. 5 Check to make certain minimum,volumes and maximum volume allowed between first nozzle and last nozzle are not exceededit,(Tarlk,Chart),. . Check each, rule in °General Piping Requirements" to make certain none have been exceeded. If any requirement is exceeded, change to a different pipe size and recalculate. See Figure 3=22. Refer to Tank Chart Minimum Pipe` Volume for P.CL=300 is 300 milliliters protecting a fryer, wok, or range (Example system pipe volume is 1,781 milliliters. therefore OK) Maximum Pipe Volume for PCL -300 is 1910 milliliters.(Example system pipe volume is 1781, milliliters, therefore OK) Maximum'Volume Allowed Between First Nozzle and Last Nozzle for PCL -300 is 1125 milliliters (Example system, the amount of 3/8 in. piping between G and L. is 25.5 feet. 25.5 feet x 37.5 mis./ft. = 956.3 ml, therefore, OK) Refer to General Piping Requirements 1. Split piping and straight piping are both allowed on PCL -300 and PCL -460 sys- tems. (Example system OK) 2. PCL -600 systems must use split piping only, with no nozzle located before the split, and with a maximum of 14 flow points per side. 1/2 in. minimum piping must be used up to the first split. (Example system N/A) 3. Maximum volume for 1/4 in. pipe between a nozzle and the preceding tee is 410 mis. (Example system N/A) 4. Maximum flow numbers for 1/4 in. pipe is 6. (Example system N/A) 5. Maximum number of elbows between a nozzle and the preceding tee is 5. (Example system has a maximum number of 2, therefore, OK) 6. Maximum of 25 elbows are allowed in the total piping system. (Example system has 11 elbows, therefore. OK) 7. Maximum difference in elevation between the tank outlet and any nozzle, or the tank outlet and the highest or low- est horizontal pipe run, is 10 ft. (Example system has 5'-6", therefore. OK) 8. No traps are allowed in the piping net- work. (Example system has no traps, there- fore, OK) 9. Pipe lengths are measured from center to center of fittings. (Example system pipe lengths were measured from center to cen- ULEX 3470 October 1, 2001 PN551274 ter of fittings, therefore, OK) 10. The internal equivalent length volume of fittings does not have. to be considered as part of the total pipe 5610•me. - (Example system OK) 11. When utilizing different size pipe in the total system, the largest size must start first and the additional pipe must . decrease as it approaches the nozzle. (Example system N/A) 12. Elbow(s) or swivel adaptors located at the nozzles do not have to be counted in the 25 elbow maximum requirement. (Example system OK) 13. Additional piping requirements when protecting a range, wok, or a fryer: • PCL -300 - Minimum of 300 ml and four (4) flow numbers required in total sys- tem. Of that minimum, 239 ml and two (2) flow numbers must be utilized at or before the range, wok, or fryer. (Example system has 1781 ml and 10 flow numbers, therefore. OK. The exam- ple system has 1050 ml and :3 flows before the frver, therefore, OK) • PCL -460 — Minimum of 660 ml and ten (10) flow numbers required in total sys- tem. Of that minimum. 180 ml and two (2) flow numbers must be utilized at or before the range, wok, or fryer. • PCL -600 — Minimum of 960 ml and four- teen (14) flow numbers required in total system. Of that minimum, 120 ml and 2 flow numbers must be utilized at or before the range, wok, or fryer. GEN. PIPING RULE NO. 1. E. 4 TANK CHART MINIMUM.'MAXIMUM PIPE VOLUME GEN. PIPING RULE NO. 10 TANK CHART MAX. VOL. GEN. BETWEEN FIRST PIPING — AND LAST NOZZI RULE NO. 7 GEN. PIPING +RULE NO. 6 �I I I GEN. PIPING RULE NO. 13 o 0 c 0 0 006193PC Figure 3-22 GEN. PIPING RULE NO. 5 TANK CHART MAX. VOL. BETWEEN FIRST AND LAST NOZZLE GEN. PIPING RULE NO. 12 Chapter 3 — System'D'esign !0..Page 3-15 I� DETECTOR PLACEMENT Detectors are required over, •ccoking`applrances and in the •_ ^~ s:� :r -. duct(s) of, protected ventilation hoods. Detectors shall be located in the plenum area of the ventilation hood. 1. Exhaust Duct(s). Each exhaust duct must have atf least one (1) detector installed in the duct entrance, located in the air stream of the cooking vapors at a maximum of 12 feet into the duct.. centered. See Figure 3-25. 2. Cooking Appliance(s). Each cooking appliance with a continuous cooking surface not exceeding 48" x 48" shall be protected by one (1) detec- tor. Cooking appliances with a continuous cooking surface exceeding 48" x 48" shall be protected by one (1) detector per 48" x 48" cooking area. Detectors used for cooking appli- ances must be located within the perimeter of the protected appliance toward the exhaust duct side of the appliance. The detector should be located in the air stream of the appliance to enhance system response time. If a cooking appliance is located under a duct opening where a detector has been mounted. it lis not necessary to utilize an additional detector provided the duct detector is not more than 12" into the duct opening. If two (2) appliances are located under a duct opening where a detector has been mounted, it is not necessary to utilize an additional detector provided the duct detector is not; more than 12" into the duct opening. See Figure 3-23. r I I A g C' APPLIANCE i APPLIANCE APPLIANCE I APPLIANCE j COVERED COVERED COVERED COVERED BY BY BY BY DETECTOR I DETECTOR DETECTOR I DETECTOR A B B C Figure 3-23. Proper Detector Placement. 0029.0PC U LEX 3470 PN551274 October 1, 2001 _•_Chapter3.—System Design Page 3-16 NOTES: ULEX 3470 October 1, 2001 PN551274 CHAPTER IV SYSTEM INSTALLATION GENERAL This chapter will detail the basic information necessary for proper installation of the Pyro-Chem Kitchen Knight II Restaurant Fire Suppression System. However, before attempting any installation it is necessary to attend a Factory Certification Training Class andbecome Certified to install the Pyro-Chem Kitchen Knight II Restaurant Fire Suppres- sion System. Because it is difficult to completely understand every aspect of an intricate pre-engineered system simply by reading the Technical Manual, Pyro-Chem Kitchen Knight II will not be responsible for system installations or mainte- nance performed by any non -Certified person(s). Pipe and fittings for the discharge piping, conduit (EMT), pipe straps, pipe hangers, mounting bolts, and other miscel- laneous equipment are not furnished as part of the Pyro-Chem Kitchen Knight II Restaurant Fire Suopression System. These items must be furnished by the installer. Before attempting any installation, unpack the entire system and check that all necessary parts are on hand. Inspect parts for damage. Verify that cylinder pressure is within the acceptable range as shown on the gauge CYLINDER INSTALLATION The cylinder and valve assembly is shipped with an anti recoil plug in the valve discharge port. CAUTION The anti -recoil plug must remain in the valve discharge port until the discharge piping is connected to the valve. RING ;Chapter 4—System Installation Pade:4-1 The cylinder must be mounted vertically. The Models PCL - .t 300 and PCL -460 cylinders must be mounted using a Model MB -15 Mounting Bracket .Kit. The Model PCL -600 cylinder must be mounted using a Model MB -1 Mounting Bracket Kit. The bracket must be securely anchored to -the wall using bolts or lag screws. The wall to which the bracket is attached must be sufficiently strong to support the cylinder. The bracket should never be fastened to dry wall or similar material. If this type of wall is encountered, studs must be located and the bracket fastened to them. See Figure 4-1. STRAP 7 MOUNTING BRACXET CYLINDER MOUNTING HOLES 0 Figure 4-1. Cylinder and Mounting Bracket Installation. 0029<5PC CONTROL HEAD INSTALLATION 1. Single Cylinder Installations. For single cylinder system installations the Model MCH3/ECH3/NMCH3 Control Head can be installed directly onto the cylinder valve. When the control head is properly aligned in the desired position, tighten the knurled locking ring to secure the assembly. See Figure 4-2. PULL GUTMPI CONNECTION AEWTE PULL GMUX TERLINATIC Figure 4-2. Single Cylinder Installation Using Model ECH3/MCH3/NMCH3 Control Head. 6MI.Pc / 003N7Pc PN551274 ULEX 3470 October 1, 2001 "Chapter 4 - System Installation Page 4-2 2. Multiple Cylinder Installations. A. Multiple Cylinder Actuation Using MCH3YECH3/NMCH3 Control Head. The Model MCH3/ECH3/NMCH3 Control. Head can be used to pneumatically actuate a maximum of three (3) agent cylin- ders. When a control head is used for multiple cylinder actu- ation, it cannot be mounted directly onto a cylinder valve. The control head must be installed remotely using a Model MB -P2 Control Head Mounting Bracket. The bracket must -be anchored to the wall using bolts or lag screws. In order to actuate the agent cylinder(s) from a control head, a 1/4" NPT x 45''1/4" flare type fitting (conforming to SAE J513c) must be screwed into the base of the control head actuator. Pneumatic tubing is then used to connect the con- trol head to the valve cap assembly of each agent cylinder valve. See Figure 4-3. NOTE Pneumatic tubing used for remote cylinder actuation shall have an outside diameter of 1/4" with a minimum wall thickness of 1/32". This is commonly known as refrigeration -type cooper tubing. All tubing fittings shall be Of the 1/4", 45' flare type conforming to SAE J513c. Compression type fittings are not acceptable. MCH3. NMCH3. ORECH3 CONTROLHEAD A single Model MCH3/ECH3/NMCH3 Control Head can actuate three (3) agent cylinders with a maximum of eight (8) feet of-0euM, tr tubing. S. Multiple Cylinder Actuation Using Model PAC -10 Pneuma# E •Actuation Cylinder. The Model PAC -10 Pneumatic Actuation Cylinder must be .used if:m6re.than three (3) agent cylinders require simulta- neous`actuation. The Model PAC -10 must be used in con- junction with a Model MCH3/ECH3/NMCH3 Control Head. The. control head is mounted on. the Model PAC -10 valve assembly. 1/4" OD COPPER TUBING 96" MAX TOTAL FOR 3 CYLINDER ACTUATION The Model PAC -10 is shipped complete with a mounting bracket. The cylinder must be mounted vertically with the nameplate facing out. The bracket must be securely anchored to the wall using bolts or lag screws. The- wall to which the bracket is attached must be sufficiently strong to support the pneumatic cylinder. The bracket should never be fastened to dry wall or similar material. If this type of wall is encountered, studs must be located and the brackE�t fas- tened to them. See Figure 4-4. 45' 1/4" FLARED TUBING NUT 1/4^ NPT X 45° 114" FLARE TYPE F!, i ING (SAE J513c1 Figure 4-3. Multiple Cylinder Actuation,Using Model MCH3/ECH3/NMCH3 Control Head. 00-28PC ULEX 3470 October 1, 2001 PN551274 Figure 4-4. Model PAC -10 Pneumatic Cylinder Installation. 0028%+Pc In order to, actuate the agent cylinders from a Model PAC -10 Pneumatic Actuation Cylinder, a 3/4" NPT x 1/4" NPT bush- ing must be screwed into the pneumatic cylinder's discharge port. A 1/4" NPT x 45° 1/4" flare type fitting (conforming to SAE J513c) must then be screwed into this bushing. Pneumatic tubing is then used to connect the PAC -10 pneu- matic cylinder to the valve cap assembly of each agent cylin- der valve. See Figure 4-5. r i Chapter 4 —System Installation Page 4-3 NOTE -'P euitatic-tubing used for remote cylinder actuation shall have an outside diameter of 1/4" with a minimum wall thickness'of 1/32". This is commonly known as -refrigeration-type copper tubing. All tubing fittings shall be of the "1/4`', 450 flare type conforming to SAE J513c. Compression type fittings are not acceptable. The Model PAC=10 pneumatic cylinder can actuate a maxi- mum of ten (10) agent cylinders with a maximum of 100 feet of pneumatic tubing. MCH3. NMCH3, OR ECH3 CONTROL HEAD 1/4. 00 COPPER TUBING 1/4" NPT X 45. 1/4" FLARE TYPE FITTING / i (SAE J513c) PAC CYLINDER 114" NPT X WV NPT / BUSHING (\\ 45° FLARED TUBING NUT 1/4 x 1/4 x 1/4 45° FLARE TEE (TYPICAL) TO REMAINING CYLINDERS —0— Figure 4-5. Multiple Cylinder Actuation Using Model MCH3/ECH3/NMCH3 Control Head. OOW27PC ULEX 3470 PN551274 October 1, 2001 Chapter 4 = System Installation k, Page'4-4• FUSIBLE LIN,K-DETECTOR INSTALLATI.QN, ,.w,, ,,:.: Fusible links area?ways used in conjunction with the Model MCH3 Mechanical Control Head. After mounting the cylinder and control head', the' fusible link line can be installed. The first step to installing the fusible link line. is to install the detector bracket(s). These brackets must be installed in the plenum area of the ventilation hood over all protected appli- ances and ineachduct.See Chapter III for detector place- ment guidelines. Note: Only ML -style Fusible Links can be used. Connect the fusible link brackets together using 1/2" conduit and the conduit connectors supplied in the detector kit (Model FLK -1/1A). A Pyro-Chem Kitchen Knight II corner pulley must be used whenever a change in conduit direction is necessary. The conduit is connected to the control head throueh a knockout in the upper left -side corner. In general, fusible links centered in the detector brackets are connected in series using 1/16" diameter stainless steel cable. The spring plate in the control head maintains tension on this series of fusible links. If the tension is released for any reason (i.e., a fusible link separates), the control head will operate and actuate the system. Maximum limitations for the fusible link detection line are as follows: Fusible links can be installed with or -without fusible link hangers (see Chapter II for description). l Fusible Link Line Limitations When Used with Model EN-MCU3, MCH3, and NMCH3 Control Heads and CSP -1, SBP -1, and WBP-1 Pulley Elbows Maximum # of detectors: 20 .Maximum length of cable: 150 feet Maximum # of pulleys: 40 1. Fusible Link Installation Without H.3naers. Begin installing links at the terminal bracket. The link is con- nected to the far side of the terminal bracket using an "S" hook. The "S" hook must be crimped closed after the link is installed. A tight loop is then made in the cable and secured by the crimp provided. This loop is connected to the other side of the terminal link (see Figure 4-6) and the cable fed through the conduit to the next bracket. The cable proceed- ing from the terminal link will be used to connect the series links (see Figure 4-7). Series links must be centered in their detector brackets. After the last link in the series is connected, the cable should be fed through the conduit back to the control head. Thread the cable through the hole in the fusible link ratchet wheel. The line must then be crimped, and the crirrio oosi- tioned inside the center of the ratchet wheel. LINK DETECTOR BRACKET TERMINAL LINK S-HCCK - Figure 4-6. Terminal Link Installation. 002B49.PC 1/18' STAINLESS STEEL CABLE FUSIBLE UNK' SERIES LINK Figure 4-7. Series Link Installation. 002NYbPC CABLE CRIMP 12" EMT CONNECTOR ULEX 3470 October 1, 2001 PN551274 - „ Chapter 4 —,System Installation .Page 4-5 NOTE Crimps,musN- fways_be.used in conjunction with two (2) .cb6re lengths. Loops are the accepted method of con- necting:Ahe cable to mechanical components. The crimp milst never'be used on a single cable. The fusible link line -can now be put into a set position by applying tension to the fusible link line. This is accomplished by using a 1/2” hex wrench on the fusible link line ratchet wheel. The ratchet wheel will be ratcheted in a clockwise direction until the spring plate makes contact with the top of the control head box. The fusible link line is now in a set position.' See Figure 4-8. FUSIBLE LINK LIN FUSIBLE LINK RATCHET WHEEL SPRING PLATE Figure 4-8. Fusible Link Line Termination. 006215PC 2. Fusible Link Installation Using Model FLH-1 Fusible Link Hangers. Beginning at the control head, feed the stainless steel cable through the conduit and brackets to the terminal bracket in one continuous length. Allow approximately two and one-half (2.5) inches of slack at each bracket for the installation of the Fusible Link Hangers. At the terminal link, a tight loop is made in the cable and secured by the crimp provided. The cable is attached to the far side of the terminal bracket using an "S" hook. The "S" hook must be crimped closed after the cable is installed. See Figure 4-9. TERMINAL LINK _C3 APPROX. 21/1' SLACK CRIMP 'S' HOOK Figure 4.9. Terminal Bracket Connection. 002877PC Begin installing the Fusible Link Hangers at the terminal bracket and work toward the control head. Loop the cable through the oval opening in the hanger and hook the fusible link on the loop. See Figure 4-10. Note: Only ML -style Fusible Links can be used. Figure 4-10. Fusible Link Connection. 00237OPC Hook the bottom of the link onto the bottom leg of the hang- er. See Figure 4-11. Figure 4-11. Fusible Link/Hanger Connection. 002879PC Center the hanger/link in the fusible link bracket by sliding it along the link line. This is easily accomplished before any tension is applied to the link line. Repeat this procedure for all fusible links. After the last hanger/link in the series is connected, the cable should be fed throuah the hole in the fusible link ratch- et wheel. The line must then be crimped, and the crimp posi- tioned inside the center of the ratchet wheel. NOTE Crimps must always be used in conjunction with two (2) cable lengths. Loops are the accepted method of con- necting the cable to mechanical components. The crimp must never be used on a single cable. The fusible link line can now be put into a set position by applying tension to the fusible link line. This is accomplished by using a 1/2" hex wrench on the fusible link line ratchet wheel. The ratchet wheel will be ratcheted in a clockwise direction until the spring plate makes contact with the top of the control head box. The fusible link line is now in a set position. See Figure 4-8. ULEX 3470 PN551274 October 1, 2001 11 11 SPRING PLATE Figure 4-8. Fusible Link Line Termination. 006215PC 2. Fusible Link Installation Using Model FLH-1 Fusible Link Hangers. Beginning at the control head, feed the stainless steel cable through the conduit and brackets to the terminal bracket in one continuous length. Allow approximately two and one-half (2.5) inches of slack at each bracket for the installation of the Fusible Link Hangers. At the terminal link, a tight loop is made in the cable and secured by the crimp provided. The cable is attached to the far side of the terminal bracket using an "S" hook. The "S" hook must be crimped closed after the cable is installed. See Figure 4-9. TERMINAL LINK _C3 APPROX. 21/1' SLACK CRIMP 'S' HOOK Figure 4.9. Terminal Bracket Connection. 002877PC Begin installing the Fusible Link Hangers at the terminal bracket and work toward the control head. Loop the cable through the oval opening in the hanger and hook the fusible link on the loop. See Figure 4-10. Note: Only ML -style Fusible Links can be used. Figure 4-10. Fusible Link Connection. 00237OPC Hook the bottom of the link onto the bottom leg of the hang- er. See Figure 4-11. Figure 4-11. Fusible Link/Hanger Connection. 002879PC Center the hanger/link in the fusible link bracket by sliding it along the link line. This is easily accomplished before any tension is applied to the link line. Repeat this procedure for all fusible links. After the last hanger/link in the series is connected, the cable should be fed throuah the hole in the fusible link ratch- et wheel. The line must then be crimped, and the crimp posi- tioned inside the center of the ratchet wheel. NOTE Crimps must always be used in conjunction with two (2) cable lengths. Loops are the accepted method of con- necting the cable to mechanical components. The crimp must never be used on a single cable. The fusible link line can now be put into a set position by applying tension to the fusible link line. This is accomplished by using a 1/2" hex wrench on the fusible link line ratchet wheel. The ratchet wheel will be ratcheted in a clockwise direction until the spring plate makes contact with the top of the control head box. The fusible link line is now in a set position. See Figure 4-8. ULEX 3470 PN551274 October 1, 2001 "Chapter 4, -.;-System Installation Page 4-6 Check to ensure that the fusible link hanger(s) remain cen- tered in the bracket after the fusible link line is set. See ,Fioure 4-12. NOTE . If wire rope. requires, splicing', a -spliee is do be a mini- mum of 12 in. from any pulley elbow or conduit adaptor to avoid interference.. . THERMAL DETECTOR INSTALLATION Thermal detectors are always used in conjunction with the Model ECH3 Electrical-Ccntrol Head. After mounting the cvlinder and control head, the thermal detector(s) can be installed. Install the thermal detector(s) in the plenum area of the ventilation hood over all protected appliances and in each duct. See Chapter III for detector placement guide- lines. Follow the instructions included with the detector for proper detector mounting procedures. SETTING THE CONTROL HEAD 1. Model MCH3/NMCH3 Mechanical Control Head. Once the fusible link line is set, the control head can be placed in the set position. To set the control head, the slide'plate is moved from right to left, ensuring the bolt extending from the cam arm is in the slot provided in the slide plate. Continue mov- ing the slide plate to the left until the latching arm is in the locked position. Insert the pull pin into the hole in the slide plate ULEX 3470 October 1, 2001 PN551274 above the latching arm. This will lock the control head in,the set position, eliminating accidental actuation during the rest of the installation procedure. See Figure 4-13. LATCHING ARM PULL PIN Figure 4-13. Control Head In Set Position. 006219Pc 2. Model ECH3 Electrical Control Head. Once the thermal detectors have been installed, the control head can be placed in the set position. To set the control head. the slide plate is moved from right to left, ensuring the bolt extendine from the cam arm is in the slot provided In the slide plate. Continue moving the slide plate to the left until the latch- ing arm is in the locked position. Insert the pull pin into the hole in the slide plate above the latching arm. This will lock the control head in the set position, eliminating accidental actuation during the rest of the installation procedure. Once the Model ECH3 Electrical Control Head is in the set position, it can be connected to the detection/actuation circuit. FUSIBLE LINK KIT (SOLD SEPARATELY) FUSIBLE LINK (SOLD SEPARATELY) FLH-1 _- FUSIBLE LINK HANGER Figure 4-12. Fusible Link/Hanger In Set Position. 002e.eovc NOTE No electrical Conception,shall be made inside the control head. AI!reiegtncal wiring shallexit the control head through the knock -out on the side of the box. All electrical connectidns must be made in an approved electrical box. Connect one of the black wires on the solenoid in the control head. to.the red.wire-of the Model MS-SPDT Miniature Switch. The brown wire from the miniature switch is then connected to one side of the first thermal detector in series. Connect the other side of the first thermal detector in series and the remaining black wire on the solenoid in the control head to the appropriate powersource after installino the Model SM -24/120 Solenoid Monitor. v CAUTION The solenoid must never be wired "hot" (not through the micro -switch). If wired this way, the non -field replaceable solenoid will be damaged and the complete control head will require replacement. NOTE A Model SM -24/120 Solenoid Monitor must always be used with an Electrical Control Head to supervise the actuation/detection circuit. Where electrical detection and/or actuation is provided. supervision shall be provided in accordance with NFPA- 17A. Alarms and indicators along with a supervised backup power source shall be provided in accordance with NFPA 72. The National Fire Alarm Code. Electrical wiring and equipment shall be installed in accordance with NFPA 70, National Electric Code or the requirements of the authority having jurisdiction. The Model ECH3-24 Electrical Control Head requires a 24VOC power supply with a minimum 2A rating. The Model ECH3-120 Electrical Control Head requires a 1A. 120VAC power supply. 'Chapter -4— System Installation Page 4-7 SOLENOID MONITOR INSTALLATION 1. Solenoid Monitor Installati* n-4wDetection Circuit. After installing the.thermal detectors and�,the control head, the Model SM -120724 Solenoid Monitor can' be iristalled.,The Solenoid Monitor is connected to the wires leading from the last thermal detector. It should be mounted in a location where it can be readily observed. The Solenoid Monitor is .an end -of -line device that supervis- es the actuation/detection circuit. It is comprised of a push - type switch with a built-in indicator light, a plug -type relay, a relay socket, and a cover plate. The light, when illuminated. indicates that the detection/actuation circuit is in the normal condition. The Solenoid Monitor also provides two sets of dry contacts. The Solenoid Monitor's cover plate is used to mount the Solenoid Monitor in a standard 6" x 4" x 3" deep electrical box. See Figure 4-1.4. 3-1/Z- MIN \l Figure 4-14. Solenoid Monitor Installation. 002881PC N L. 120 VAC - - - - - - - - - - - -- I I a 12 B � 1 q g SM 120 L_ _ _ _ - - - - - - - - SOLENOID MONITOR Figure 4-14.1. Wiring Diagram, Solenoid. =582PC ULEX 3470 PN551274 October 1, 2001 Cha0ter4 :Sys<tem Installation Page 4-8 All wire for circuits using,the Model SM -24 shall be 18 gage REMOTE PULL STATION minimum, or as required by local code. All wire for circuits using the Model SM -120 shall.be 14 gage minimurrt. or',as'"'" ,.... aINSTALLATION required by local code. The basic 'Wiring -diagram`for both the The Model RPS -M Remote Mechanical Pull Station is used Model SM -24 and Model SM -120 is shown in Figure 4'=14.1. for remote mechanical actuation of all system releasing deviggs., It is to be located near an exit in the path of egress After the Solenoid.Monitor has been installed, the detec- from the hazard area no more than five feet above the floor. tion/actuation circuit can be connected to the appropriate power source and energized. To energize the detector/actua- NOTE tion circuit, depress the switch on the Solenoid Monitor. The A Model RPS -M Remote Mechanical Pull Station must light will illuminate to indicate that the circuit is properly be used for manual activation of a Model EN-IvICU3 or installed. If the light fails to illuminate, the wiring must be a Model NMCH3 releasing device. checked. 2. Solenoid Monitor When Used As A Reset Relay The Model SM -24/120 can be used as a reset relay when required. A reset relay is required whenever an electrical gas shut-off valve is used in conjunction with the Pyro-Chem Kitchen Knight II Restaurant Fire Suppression System. For typical wiring connections, see Figure 4-15. SOURCE VOMER SOURCE re - The Pull Station can be surface mounted or flush mounted. For flush mounting a RACO #232 4" deep electrical box or equivalent must be used (dealer supplied). It is connected to the releasing device using 1/16" diameter stainless steel cable. The cable enters the pull station box through the cen- ter hole in the bottom, top, either side, or the center back hole. The cable enters the control head through the MICRO SWITCH MOUNTED IN CONTROL HEAD / sa.e*ao MERG= l(/ (SFIUMi EiIEROI�C) Solenoid Mondor uc-4+r CIN-a?cur n OMMIL PUSH TO RESET. Figure 4-15. Solenoid Monitor'Wiring With Electrical Gas Shutoff Valve. 002882PC ULEX 3470 October 1, 2001 PN551274 top -center knockout. The cable must be enclosed in 1/2" conduit with a Pyro=Chem Kitchen"Knight II corner pulley at each change in conduit; direction. Maximum limitations fetes : 1/2' EMT the Model RPS -M Remote MAchanjcal.Pull-Station are as CONNECTC follows: , i Model RPS -M Cable Run Limitations When Used with Model ECH3, MCH3, EN-MCU3, and NMCH3 Control Heads and CSP -1, SB13-1, and WBP-1 Pulley Elbows Maximum length of cable: 150 feet Maximum # of pulleys (1/16"): 40 After mounting the pull, station box and conduit, feed the stainless steel cable from the releasing device, through the conduit, and into the pull station box. Feed the cable throuah the bushing and through'the hole provided in the pull handle. Loop the cable through the pull handle and secure it with the crimp provided (see Figure 4-16). PULL STATION TERMINATIO PULL STATION / CONNECTION _f^ `:"..Chapter 4 - System Installation - Page 4-9 I nvu PULL BUSHING HANDLE Figure 4-16. Model RPS -M Remote Pull Station Installation. 00288APC Cut and thread the cable through the hole in the latching arm of the control head and pull the cable ticht. Crimp the cable approximately ten (10) to twelve (12) inches below the latching arm. Note: NFPA-17A requires the pull length to be no more than 14 in. NOTE Crimps must always be used in conjunction with two (2) cable lengths. Loops are the.accepted method of con- necting the cable to mechanical components. The crimp must never be used on a single cable. Pull the pull handle until the crimp touches the latching arm. See Figure 4-17. Coil the excess cable in the pull box and attach the cover plate with the four screws provided. Insert the pull handle into the cover plate and insert the plastic break rod. PULL CLITION CokwcTiON AFMIOTE PULL STATIC TERMINAnc Figure 4-17. Model RPS -M Remote Pull Station. 00821OPG007847PC ULEX 3470 PN551274 October 1, 2001 '1��111111Nn111111111111111�;/ CJ �� as • 111 _f^ `:"..Chapter 4 - System Installation - Page 4-9 I nvu PULL BUSHING HANDLE Figure 4-16. Model RPS -M Remote Pull Station Installation. 00288APC Cut and thread the cable through the hole in the latching arm of the control head and pull the cable ticht. Crimp the cable approximately ten (10) to twelve (12) inches below the latching arm. Note: NFPA-17A requires the pull length to be no more than 14 in. NOTE Crimps must always be used in conjunction with two (2) cable lengths. Loops are the.accepted method of con- necting the cable to mechanical components. The crimp must never be used on a single cable. Pull the pull handle until the crimp touches the latching arm. See Figure 4-17. Coil the excess cable in the pull box and attach the cover plate with the four screws provided. Insert the pull handle into the cover plate and insert the plastic break rod. PULL CLITION CokwcTiON AFMIOTE PULL STATIC TERMINAnc Figure 4-17. Model RPS -M Remote Pull Station. 00821OPG007847PC ULEX 3470 PN551274 October 1, 2001 Chapter 4 System Installation Page4-10. GAS SHUT-OFF VALVE INSTALLATION 1. Mechanical Gas Shut -Off Valve Installation. The Model MCH3/NMCH3 Control Head is used to operate the mechanical gas shut-off valve. This valve is located in the fuel gas supply line to the cooking appliance(s). The valve body has an arrow which indicates direction of gas flow through the valve.' The gas shut-off valve is spring loaded and requires five pounds of force to hold it open. This force is supplied by a 1/16" diameter stainless steel cable that is connected to the control head. After the valve is installed in the gas line, 1/2" conduit must be run from the top center knockout of the gas valve box to the lower right-hand knockout in the control head. A Pyro- Chem Kitchen Knight II corner pulley is used wherever a change in conduit direction is required. Gas Valve Cable. Run Limitations When Used with Model MCH3, EN-MCU3, and NMCH3 Control Heads and CSP -1, SBP -1, and WBP-1 Pulley Elbows Maximum length of cable: 100 feet Maximum r of oullevs: 30 Remove the gas valve cover and thread the stainless steel cable through the conduit back to the control head. Thread the cable through the hole in the gas valve ratchet wheel. The line must then be crimped, and the crimp positioned inside the center of the ratchet wheel. NOTE Crimps must always be used in conjunction with two (2) cable lengths. Loops are the accepted method of con- necting the cable to mechanical components. The crimp must never be used on a single cable. At the gas valve, loop the cable through the valve stem and secure it with the crimp provided (see Figure 4-18). ULEX 3470 October 1, 2001 PN551274 UNION VALVE BODY UNION Figure 4-18. Gas Valve Installation. 002886PC CAUTION Do not overtigh ten gas valve. Overtightening the gas valve may cause the valve to not close com- pletely, thus not fully shutting the fuel supply off to the appliance. The gas valve line can now be put into a set position by applying tension to the gas valve line. This is accomplished by using a 1/2" hex wrench on the cas valve ratchet wheel. The ratchet wheel will be ratcheted in a clockwise direction until the gas valve is, fully open. See Instruction Sheet. Part No. 550571, included in gas valve shipping assembly, for detailed information. Secure the gas valve cover ;date to the cas valve box with the four (4) screws provided. The gas valve line is now in a set position. See Figure 4-19. Figure 4-19. Gas Valve Line Termination. 006217PC 2. Electrical Gas Shut -Off Valve Installation. The Model MCH3/ECH3/NMCH3 Control Head is used to operate the, electrical gas shut-off valve. This valve is locat- ed in the fuel gas supply line to the cooking appliance(s). The valve body has an arrow which indicates direction of gas flow through the valve. A reset relay must always be used with an electrical gas shut-off valve. For proper wiring of the electrical gas shut-off valve, see Figure 4-15. 1/2" EMT CONNECTOR �- CONTROL BOX VALVE BODY UNION Figure 4-18. Gas Valve Installation. 002886PC CAUTION Do not overtigh ten gas valve. Overtightening the gas valve may cause the valve to not close com- pletely, thus not fully shutting the fuel supply off to the appliance. The gas valve line can now be put into a set position by applying tension to the gas valve line. This is accomplished by using a 1/2" hex wrench on the cas valve ratchet wheel. The ratchet wheel will be ratcheted in a clockwise direction until the gas valve is, fully open. See Instruction Sheet. Part No. 550571, included in gas valve shipping assembly, for detailed information. Secure the gas valve cover ;date to the cas valve box with the four (4) screws provided. The gas valve line is now in a set position. See Figure 4-19. Figure 4-19. Gas Valve Line Termination. 006217PC 2. Electrical Gas Shut -Off Valve Installation. The Model MCH3/ECH3/NMCH3 Control Head is used to operate the, electrical gas shut-off valve. This valve is locat- ed in the fuel gas supply line to the cooking appliance(s). The valve body has an arrow which indicates direction of gas flow through the valve. A reset relay must always be used with an electrical gas shut-off valve. For proper wiring of the electrical gas shut-off valve, see Figure 4-15. r TEE PULLEY INSTALLATION The Model TP -1 Tee Pulley is., used to connect two (2) mechanical gas valves or two (2) remotermechanical�pull stations to a single control head. The cable proceeding, from the control,head must always enter the branch of the tee pulley. See Figure 4-20. r'• A tee pulley that is used to close two (2) gas valves can only be used to close gas valves with similar stem travel. Gas valves from 3/4" up to 1 1/2" can be used on the same tee pulley. A 2" gas valve can be used only with another 2" gas valve. Gas valves from 2 1/2" up to 3" can be used on the same tee pulley. As an example, using a 3/4" gas valve with a 3" gas valve will not allow the 3" valve to fully open. CAUTION The tee pulley must never be used to connect multiple fusible link lines to a single control head. Figure 4-20. Tee Pulley Installation 002888PC MINIATURE SWITCH INSTALLATION The Model MS -SPOT, MS-OPDT, MS -VDT, or MS-4POT Miniature Switch is available for use where an electrical out- put is required. These switches can be field installed in the control head. See Figure 4-21 and Figure 4-22 and refer to Instruction Sheet, Part No. 551159, included with switch shipping assembly, for detailed mounting instructions. Figure 4-21. Miniature Switch Installation in Model MCH3 /NMCH3Control Head. 006218PC PULL STATION CONNFCTM REMOTE PULL turn TEANINATIC Chapter 4 — System -Installation Page*4-11 Figure 4-22. Miniature Switch Installation in Model ECH3 Control Head. 0006. _Pc NOTE The Model ECH3 Control Head is supplied with a Model MS-DPDT Miniature Switch. However. one set of con- tacts on the switch must be used in the actuation/ detection circuit and cannot be used for electrical output. NOTE No electrical connections shall be made inside the con- trol head. All electrical wiring shall exit the control head through the knock -out on the side of the box. All electri- cal connections must be made in an approved electrical box. These switches may be used to provide an electrical signal to the main breaker and/or operate electrical accessories pro- vided the rating of the switch is not exceeded. Wiring con- nections are shown in Figure 4-23. The contact ratings for the switch is as follows: Contact Ratings For Miniature Switches 21 amps 1 HP, 125, 250, 277 VA -C or 2 HP, 250, 277 VAC BLACK RED BROWN Figure 4-23. Wiring Diagram For Model MS-SPDT Miniature Switch. 002903PC ULEX 3470 PN551274 October 1, 2001 �111'I'..� 'NII 111 'n Q� Figure 4-21. Miniature Switch Installation in Model MCH3 /NMCH3Control Head. 006218PC PULL STATION CONNFCTM REMOTE PULL turn TEANINATIC Chapter 4 — System -Installation Page*4-11 Figure 4-22. Miniature Switch Installation in Model ECH3 Control Head. 0006. _Pc NOTE The Model ECH3 Control Head is supplied with a Model MS-DPDT Miniature Switch. However. one set of con- tacts on the switch must be used in the actuation/ detection circuit and cannot be used for electrical output. NOTE No electrical connections shall be made inside the con- trol head. All electrical wiring shall exit the control head through the knock -out on the side of the box. All electri- cal connections must be made in an approved electrical box. These switches may be used to provide an electrical signal to the main breaker and/or operate electrical accessories pro- vided the rating of the switch is not exceeded. Wiring con- nections are shown in Figure 4-23. The contact ratings for the switch is as follows: Contact Ratings For Miniature Switches 21 amps 1 HP, 125, 250, 277 VA -C or 2 HP, 250, 277 VAC BLACK RED BROWN Figure 4-23. Wiring Diagram For Model MS-SPDT Miniature Switch. 002903PC ULEX 3470 PN551274 October 1, 2001 �111'I'..� �•nn•niil/ 111 'n Figure 4-21. Miniature Switch Installation in Model MCH3 /NMCH3Control Head. 006218PC PULL STATION CONNFCTM REMOTE PULL turn TEANINATIC Chapter 4 — System -Installation Page*4-11 Figure 4-22. Miniature Switch Installation in Model ECH3 Control Head. 0006. _Pc NOTE The Model ECH3 Control Head is supplied with a Model MS-DPDT Miniature Switch. However. one set of con- tacts on the switch must be used in the actuation/ detection circuit and cannot be used for electrical output. NOTE No electrical connections shall be made inside the con- trol head. All electrical wiring shall exit the control head through the knock -out on the side of the box. All electri- cal connections must be made in an approved electrical box. These switches may be used to provide an electrical signal to the main breaker and/or operate electrical accessories pro- vided the rating of the switch is not exceeded. Wiring con- nections are shown in Figure 4-23. The contact ratings for the switch is as follows: Contact Ratings For Miniature Switches 21 amps 1 HP, 125, 250, 277 VA -C or 2 HP, 250, 277 VAC BLACK RED BROWN Figure 4-23. Wiring Diagram For Model MS-SPDT Miniature Switch. 002903PC ULEX 3470 PN551274 October 1, 2001 Chapter 4,=•System ,lnstallation Page 4-12 - .. PIPE AND NOZZLE INSTALLATION Allpipeends shall"'1 e61horoughly reamed after cutting and all oil and foreign matter removed from the pipe. It is recom- mended that the following procedures be followed: 1. Use Schedule 40 black iron, chrome. -plated, or stainless steel pipe and fittings. Do not use hot -dipped galvanized iron pipe or fittings in the agent distribution piping. 2. Before assembling the pipe and fittings, make certain all ends are carefully reamed and blown clear of chips and scale. Inside of pipe and fittings must be free of oil and dirt. 3. The distribution piping and fitting connections, located in ther hood or the protected area, must be sealed with pipe tape. When, applying pipe tape, start at the second male thread and wrap the tape (two turns maximum) clockwise around the threads, away from the pipe opening. 4. Do not over -tighten, but be sure the pine is snug. Do not back -off sections of pipe to make them fit better. If the pipe was cut too short. re -cut another pipe to the proper length. CAUTION Do not apply Teflon tape to cover or overlap the pipe opening, as the pipe and nozzles could become blocked and prevent the proper flow of agent. Do not use thread sealant or pipe joint compound. All piping shall be securely fastened by means of pipe hand- ers and/or pipe straps. A union should be installed in the dis- charge piping, as close to the cylinder valve as possible, to permit disconnection and removal for inspection and service. Dry air or nitrogen should be blown through the discharge piping to remove chips and other debris prior to installation of nozzles. Nozzles shall be installed in accordance with the limitations described in Chapter Ill of this manual. Blow -off caps are provided for each nozzle. These will prevent dirt and grease from clogging the nozzle. SYSTEM CHECKOUT AFTER INSTALLATION, 1. Model MCH3/NMCH3 Mechanical Control Head. Before putting the system into service, all components must be checked for proper operation. During this checkout, assure that the carbon dioxide pilot cartridge is not installed in the control head actuator. Remove the pull pin from the hole in the slide plate. ULEX 3470 October 1, 2001 PN551274 To check satisfactory operation of the control. head, cut the terminal link or the "S" hook holding the link. This will relieve all tension on the fusible link line `and op&ate the control head. The slide°plate will have moved fully to the right. The gas valve cable will have been released, causing the gas valve to close. Any auxiliary equipment connected to the dry contacts of the solenoid monitor and/or the Miniaiure Switch in the control head will have operated. If any of these events fail to occur, the problem must be investigated and repaired. Repair the terminal link and put the fusible link line back into the set position. This is accomplished by using a 1/2" hex wrench on the fusible link line ratchet wheel. The ratchet wheel will be ratcheted in a clockwise direction until the spring plate makes contact with the top of the control head box. Once the fusible link line is set (note: Refer to page 4 through 4-6 for fusible link installation details), the control head can be placed in the set position. To set the control head, the slide plate is moved from right to left. ensuring the bolt extending from the cam arm is in the slot provided in the slide plate. Continue moving the slide plate to the left until the latching arm is in the locked position. Once the control head is set, pull the pull handle on the remote pull station to assure that the control head ooerates. If the control 'head operates normally, the control head can be reset as described above. Insert the pull pin into the hole in the slide plate above the latching arm. Replace the pull station handle. pull pin, and nylon tie. Assure that the gas valve is fully open by ratcheting the eas valve ratchet wheel. CAUTION Before screwing the carbon dioxide pilot cartridge into the actuator, ensure that the actuator has a Teflon 0 -ring installed. Using a felt -tipped marker, write the date of installation in the gray area of the carbon dioxide pilot cartridge. Screw the cartridge into the control head actuator until hand -tight. Never use a wrench to tighten the cartridge into the actuator. Remove the pull pin from the hole in the slide plate and install the control head cover. Insert the pull pin through the local manual control handle and into the bushing. Secure the pull pin with the nylon tie provided. 2. Model ECH3-24/120 Electrical Control Head. 6e, fore putting the system into service, all components must be'checked for proper operation. 'During this checkout, assure that the carbon dioxide pilot cartridge is not installed in the control head actuator. Remove the pull pin from the hole in the slide plate. To check satisfactory operation of the control head, apply heat to the last thermal detector in series. This will operate the control head. The slide plate will have moved fully to the right. The indicator light on the solenoid monitor will go out. Any auxiliary equipment connected to the dry contacts of the solenoid monitor and/or the Miniature Switch in the control head will have operated. If any of these events fail to occur, the problem must be investigated and repaired. Once the thermal detector has cooled, the control head can be placed in the set position. To set the control head, the slide plate is moved from right to left, ensuring the bolt extending from the cam arm is in the slot provided in the slide plate. Continue moving the slide plate to the left until the latching arm is in the locked position. Once the control head is set, pull 'the pull handle on the remote pull station to assure that ,the control head operates. If the control head operates normally, the control head can `- be reset as described above. Insert the pull pin into the hole in the slide plate above the latching arm. Replace the pull station handle, pull pin, and nylon" tie. Energize the actuation/detection circuit by depressing the push button on the solenoid monitor. CAUTION Before screwing the carbon dioxide pilot cartridae into the actuator, ensure that the actuator has a Teflon O-ring installed. Using a felt -tipped marker, write the date of installation on the carbon dioxide pilot cartridge. Screw the cartridge into the control head actuator until hand -tight. Never use a wrench to tighten the cartridge into the actuator. Remove the pull pin from the hole in the slide plate and install the control head cover. Insert the pull pin through the local manual control handle and into the bushing. Secure the pull pin with the nylon tie provided. Chapter 4 — System Installation Page -4.13 ULEX 3470 PN551274 October 1, 2001 r A}t Chapter 4— System, Installationi Page, -4_14 r ENCLOSURE INSTALLATION_ INSTRUCTIONS MODEL EN-MCU3 (P/N 551208) ., w. AND MODEL EN -S (P/N 550966) MOUNTING The Model EN-MCU3 and/or EN -S Enclosure must be securely anchored to the wall using bolts or lac screws. The wall to which the enclosure is attached must be sufficiently strong. The enclosure should never be fastened to dry wall or similar material. If this type of wall is encountered, studs must be located and the enclosure fastened to them:' Three (3) center mounting holes allow either enclosure to be mounted on a single stud. Four (4) corner mounting holes are also available. See Figure 4-24. FUSIBLE LINK DETECTOR INSTALLATION The Model EN-MCU3 Enclosure can support a fusible link detection system. The Model EN -S EIclosure cannot support a fusible link detection system and must be used in conjunction with the Model EN-MCU3 Enclosure or a Model MC-13/ECH3/NMCH3 Control Head. After mounting the enclosure, the fusible link line can be installed. The first step to installing the fusible link line is to install the detector brackets. These brackets must be installed in the plenum area of the ventilation hood over all protected appii- ances and in each duct. See Chapter III for detector placement guidelines. Connect the fusible link brackets together using 1/2" EMT conduit and the conduit connectors supplied in the detector kit (Model FLK -1/1A). Pyro-Chem Kitchen Knight II corner pulleys must be used whenever a change in conduit direction is necessary. The conduit is connected to the enc!csure through a top knockout. See Fusible Link Detector Installation Section of this chapter (pages 4-4 - 4-6) for fusible link installation guidelines. Before attaching the stainless steel cable to the fusible iink line ratchet wheel, it must be run below the fusible link line pulley in the enclosure. See Figure 4-25. TO REMOTE MANUAL PULL STATION To DISCHARGE PIPING TO GAS VALVE SHUT-OFF Mounting Holes TO FUSIBLE LINKS I I I I TO ADDITIONAL CYLINDERS OPTIONAL TO ADDITIONAL CYLINDERS � MINIATURE SWITCH CONNECTION i Mounting Holes I I i I I� I I ! Model EN-MCU3 Model EN -S TO GAS VALVE SHUT-OFF Figure 4-24. Models EN-MCU3 and EN -S Enclosures. 002946PC ULEX 3470 October 1, 2001 PN551274 Chapter 4 — SystgTdnstalladon Y Page 4:;'l Fusible Link To Remote Pulley Pull Station Fusible Link 'Ratctiet Wheel c G, L47n o � r . oa r0 0J 0 Figure 4-25. Model EN-MCU3 Fusible Link Line and Remote Pull Station Termination. ocze:•=c SETTING THE MODEL EN-MCU3 After the last link in the series is connected, the cable should be fed throueh the conduit back to the Model EN-MCU3. It must be fed under the fusible link line pulley and through the hole in the fusible link ratchet wheel. The line must then be crimped, and the crimp positioned inside the ratchet wheel. NOTE Crimps must always be used in conjunction with two (2) cable lengths. Loops are the accepted methoc of connecting the cable to mechanical components. The crimp must never be used on a single cable. Crimps must always be used in conjunction with two (2) cable lengths. Loops are the accepted method of connectins the cable to mechanical components. The crimp must never be used on a single cable. - i The fusible link line can now be put into a set position by tensioning the fusible link line. This is accomplished by using a 1/2" hex wrench on the fusible link line ratchet wheel. The ratchet wheel will be ratcheted in a clockwise direction until the spring plate is parallel to the top of the enclosure. The fusible link line is now in a set position. Once the fusible link line is set. the Model EN-MCU3 Enclosure can be placed in the set position. To set the Model EN- MCU3, the slide plate is moved from right to left, ensuring the bolt extending from the cam arm is in the slot provided in the slide plate. Continue moving the slide plate to the left until the latching arm is in the locked position. Insert the pull pin into the hole in the slide plate above the latching arm. This will lock the control mechanism in the set position, eliminating acci- dental actuation during the rest of; the installation procedure. See Figure 4-25. REMOTE PULL STATION INSTALLATION The Model RPS -M Remote Mechanical Pull Station is used for remote manual actuation of the Model EN-MCU3 It is to be located near an exit in the path of egress from the hazard area no more than five feet above the floor. The Pull Station is connected to the Model EN-MCU3 using 1/16" diameter stainless steel cable. The cable enters the Model EN-MCU3 through a knockout in the top of the enclosure. See Figure 4-25. See Remote Pull Station In Section of this chapter for remote pull station installation guidelines. ULEX 3470 PN551274 October 1, 2001 Chapter. -,4 -'-:System Installation a Page+16. GAS SHUT-OFF VALVE INSTALLATION The Model EN-MCU3 can be used to operate a- mechanica'.. gas shut-off valve. This valve is located in the fuel gas supply line to the cooking appliance(s}..T,he valve`body has an arrow which indicates direction of gas flow through the valve -.,The,, -- gas shut-off valve is spring loaded and requires -five pounds of force to hold it open. This force is supplies by a 1/16" diameter stainless steel cable that is connected to the Model EN-MCU3. See "Gas Shut -Off Valve Installation" section of this chapter for gas valve shut-off installation guidelines. After the valve is installed in the gas line, 1/2" conduit must be run from the top center knockout of the gas valve box to the top or bottom knockout in the enclosure. See Figure 4-24. A Pyro-Chem Kitchen Knight II corner pulley is used wherever a change in conduit direction is required. Remove the gas valve cover and thread the stainless steel cable through the conduit back to the Model EN-MCU3. If the cable enters the enclosure through the bottom knockout, the cable must be run over the gas valve line pulley (see Figure 4- 26). If the cable enters the enclosure through the top knockout, the cable must be run under the gas valve line pulley (see Figure 4-27). Thread the cable through the hole in the gas valve ratchet wheel. The line must then be crimped, and the crimp positioned inside the center of the ratchet wheel. CAUTION The gas valve cable must always utilize the gas valve pulley and exit the top or bottom of the enclosure. The gas valve cable cannot exit the side of the enclosure. 4 At the eas valve, loop the cable throuah the valve stem and secure it with the crimp provided (see Figure 4-13. pane 4-10). The gas valve line can now be put into a set position by applying tension to the gas valve line. This is accomplished by using a 1/2" hex wrench on the gas valve ratchet wheel. The ratchet wheel will be ratcheted in a clockwise direction until the gas valve is fully open. Secure the gas valve cover plate to the gas valve box with the four (41) screws provided. The gas valve line is now in a set position. See Figure 4-26 and/or Figure 4-27. CAUTION Do not overtighten gas valve. Overtightening the gas valve may cause the valve to not close completely, thus not fully shutting the fuel supply off to the appliance. ULEx 3470 October 1, 2001 PN551274 , J Chapter 4—System Installation- , Page4-17,', ELECTRICAL PROVIDED E O' GAS VALVE LINE PULLEY Figure 4-26. Gas Valve / Miniature Switch Installation. 0029+BPC -LECT�;ICAL EOX �s PEOVIDEE oY OTHE=S , 1 d 1 0 \ 1• GAS VALVE LINE PULLEY Figure 4-27. Gas Valve / Miniature Switch Installation. 002949PC MINIATURE SWITCH INSTALLATION The Model MS-SPDT, MS-DPDT, MS-SPDT, or MS-4PDT-EN Miniature Switch is available for use where an electrical output is required. These switches can be field installed in the Model EN-MCU3. See Figure 4-26 and/or Figure 4-27. These switches may be used to provide an electrical signal to the main breaker and/or operate electrical accessories provid- ed the rating of the switch is not exceeded. Wiring connections for the Model MS-SPDT are shown in Figure 4-23 (page 4- 11). The contact ratings for both switches are as follows: Contact Ratings For"Miniature Switches: 21 amps 1 HP, 125, 250, 277 VAC or 2 HP 250 277 VAC Three (3) knockouts are provided for Miniature Switch wiring. The upper right -side knockout must be used when the gas valve line exits the bottom of the enclosure (see Figure 4-26). The lower right -side knockout must be used when the gas valve line exits the top of the enclosure (see Figure 4-27). An additional knockout located on the top of the enclosure is also provided (see Figure 4-24) and'may be used in either situation. NOTE No electrical connections shall be made inside the control head. All electrical wiring shall exit the control head through the knock -out on the side of the box. All electrical connections must be made in an approved electrical box. i J ULEX 3470. PN551274 October 1, 2001 Chaptee41=,System Installation Page 4-i8' CYLINDER INSTALLATION 1. Single Cylinder. InstaLlaticin - PCL -300%460:. - :... The Model EN-MCU3 can be used for single cylinder installations. It can support either the Model PCL -300 or PCL -460 cylinder assemblies. The cylinder must be placed in the enclosure=,avith the discharge port to the left. No additional mount- ing bracket is required when the Model EN-MCU3 is used. In order to actuate the agent cylinder from the Model EN-MCU3's control mechanism, pneumatic tubing must be used to connect the actuator to the valve cap assembly of the agent cylinder valve. A 1/4" NPT x 1/4", 45° flare type elbow is includ- ed and must be installed in the actuator of the Model EN-MCU3 Enclosure. See Figure 4-28. NOTE Pneumatic tubing used for cylinder actuation shall have an outside diameter of 1/4" with a minimum wall thickness of 1/32". This is commonly known as refrigeration -type copper tubing. All tubing fittings shall be of the 1/4", 45° flare type conformino to SAE J513c. Compression type fittings are not acceptable. Figure 4-28. Single Cylinder Installation with Figure 4-29. Multiple Cylinder Installation with Model EN-MCU3 Mechanical Control Unit. Model EN-MCU3 Enclosure and Model EN -S Enclosure. 002950Pc 2. Multiple Cylinder Installation - PCL -300/460. The Model EN -S can be used in conjunction with the Model EN-MCU3 Enclosure or Model MCH3/ECH3 Control Head for multiple cylinder installations. A sinaie Model EN-MCU3 can be used to pneumatically actuate a maximum of three (3) agent cylinders. One (1) agent cylinder can be installed in the Model EN-MCU3 Enclosure; the additional agent cylinder(s) can either be mounted in a Model EN -S Enclosure or with a Model MB -15 Mounting Bracket. When an enclosure is used, the cylinders must be placed in the enclosure(s) with the discharge port to the left. No additional mounting bracket is required when a cylinder is.installed in the Model EN-MCU3 or EN -S Enclosure. In order to actuate the agent cylinders from the Model EN-MCU3, pneumatic tubing must be used to connect the EN-MCU3 actuator to the valve cap assembly of each agent cylinder valve. Pneumatic tubing must be run from the actuator in the Model EN-MCU3 to the Model EN-S(s) through the side knockout. A 1/4", 45° flare x 1/4", 45' flare x 1/4" NPT tee is includ- ed with the Model EN -S and must be installed in the Model EN-MCU3 actuator. See Figure 4-29. NOTE Pneumatic tubing used for remote cylinder actuation shall have an outside diameter of 1/4" with a minimum wall thick- ness of 1/32". This is commonly known as refrigeration -type copper tubing. All tubing fittings shall be of the 1/4", 45° flare type conforming to SAE J513c. Compression type fittings are not acceptable. A single Model EN-MCU3 can actuate a maximum of three (3) cylinders with up to 8' of copper tubing. ULEX 3470 October 1, 2001 PN551274 I Chapter 4 System lnstallation�. E z a _ tit a Pa' . . ge 4-19 SYSTEM CHECKOUT AFTER INSTALLATION Before putting the system into service, all comppnentsempst be checked for proper operation. During this checkout, assure that the carbon dioxide pilot;cartridge is,raC installed in the Model EN-MCU3 actuator. Remove the pull pin from the 'hole -in - ' the slide plate. To check satisfactory operation of,' the control mechanism, cut-tfie terminal link or the "S" hook holding the link. This will relieve all tension on the fusible link line and operate the control mechanism. The slide plate will have moved fully to the right—The-gas valve cable will have been released, causing the gas valve to close. Any auxiliary equipment connected to the dry contacts of the solenoid monitor and/or the Miniature Switch in the Model EN-MCU3 will have operated. If any of these events fail to occur, the problem must be investigated and repaired. Repair the terminal link and put the fusible link line back into the set position. This is accomplished by using a 1/2" hex wrench on the fusible link line ratchet wheel. The ratchet wheel will be ratcheted in a clockwise direction until the spring plate is parallel to the top of the enclosure. Once the fusible link line is set, the control mechanism can be placed in the set position. To set the control mechanism, the slide plate is moved from right to left, ensuring the bolt extendine from the cam arm is in the slot provided in the slide plate. Continue moving the slide plate to the left until the latching arm is in the locked position. Once the control mechanism is set. Pull the pull handle on the remote ipull station to assure that the control head operates. If the control mechanism operates normally, the control mechanism can be reset as described above. Insert the pull pin into the hole in the slide plate above the latching arm. Replace the pull station handle. pull pin, and nylon tie. Assure that the gas valve is fully open by ratcheting the pas valve ratchet wheel. Do not overtighten. CAUTION Before screwing the carbon digzide pilot cartridoe into the actuator, ensure that the actuator has a Teflon O-ring installed. Using a felt -tipped marker, write the date of installation on the carbon dioxide pilot cartridge. Screw the cartridoe into the Model EN-MCU3 actuator until hand -tight. Never use a wrench to tighten the cartridge into the actuator. Remove the pull pin from the hole;in the slide plate. Secure the Model EN-MCU3 or EN -S cover with the screws orovided. U LEX 3470. PN551274 October 1, 2001 -7:. Chapter 5 Maintenan6e.. -5 Page, CHAPTER V SYSTEM MA'INTENANCE "AGENERAL ANNUAL MAINTENANCE This chapter'w*6 detail the basic information necessary for 1. Inspect as per semi-annual mai6te'n-ance instructions. Do proper maintenance of the Pyro-Chem Kitchen Knight 11 not reconnect control head at this time. Restaurant Fire Suppression System. However. -before attempting any system maintenance, it is necessary to attend a Factory Certification Training Class and become I Pyro-Chem Kitchen certified to install and maintain the� Knight 11 Restaurant Fire Suppression System. Because it is difficult to completely understand every aspect of an intricate pre-engineered system simply by reading the Technical Manual. Pyro-Chem Kitchen Knigh,t 11 will not be responsible for system maintenance performed' by any non-cerTified per- son(s). SEMI-ANNUAL MAINTENANCE 1. Check that the hazard area has not chanced. 2. Check that the system has not!been tampered with. ie.. nozzles removed, nozzles not i aimed properly. piPino not suPported properly, blow off caps in place. 3. Check the entire system for mechanical damace. 4. Check all nozzle orifices to make certain thev are not piva-g-ed. Replace blow off caps or O-ring if necessary, CAUTION Before continuing, remove the cover from the con- trol head and insert the safety pin in the hole in the slide plate above the latching arm. This will secure the system. preventing accidental dis- charae. S. Disconnect the control head or1pneumatic tubing -from the valve cap assembly of each agent cylinder. Remove the carbon dioxide pilot cartridge in the control head. Remove the safety pin from the slide plate. Actuate the control head to ensure it is functioning properly. Make certain the gas sh6t-off valve a ':nd remote pull station are functioning properly. 6. Inspect the fusible link detectors and pulley elbows for excessive grease -buildup. Clean or replace links or elbows if necessary. 7. Reinstall the carbon dioxide pi.Ict cartridge, reconnect the control head, and replace the control head cover and nylon tie. 8. Inspect the cylinder pressure. Tap the gauge lightly to ensure the needle is moving freely. 2. Disconnect the discharge pi ' oing from the valve outlet. Using air or nitrogen, blow out the piping. Replace all nozzle caps. 3. Remove the cylinder to verify the fill weight as shown on the nameplate. 4. Replace the carbon dioxide Pilot cartrido.e. 5. Replace all fusible link detectors. 6. Reconnect the control head. Replace the control head cover and nvIon tie. 12 -YEAR MAINTENANCE Along with the reo ' uired annual maintenance requirements, the fanks must be removed from the system. pro ' pedy dis- cnaroed. and hvdrostatically tested per the requirements of NFPA-17A. The tank should be refilled with fresh agent. ULEX 3470 PN551274 October 1, 2001 CHAPTER VI SYSTEM RECHARGE GENERAL v, This chapter will detail'-fhe basic information necessary for proper recharge of the Pyro-ChemiKitchen Knight II Restaurant Fire. Suppression System. However, before, attempting any system recharge, it is necessary to attend a Factory Certification Training Class and become certified to install, maintain, and recharge the Pyro-Chem Kitchen Knight 11 Restaurant Fire Suppression System. Because it is difficult to completely understand every aspect of an intricate pre-engineered system simply by reading the Technical Manual, Pyro-Chem Kitchen Knight II will not be responsible for system recharge performed by any non -certified person(s). SYSTEM CLEANUP CAUTION Before attempting any cleanup. make certain that all fuel sources to the equipment to'be cleaned have been shut off. Make certain that the exhaust hood and all appliance electrical controls have been de -energized to avoid any chance of electrical shock resulting from the cleaning process of electrically conductive alkaline liq- uid agent and/or its residue. - Make certain all surfaces to be cleaned have cooled down to room temperature. Do not use water to clean any appliances that contain hot grease or cooking oils. Doing so may result in vio- lent steaming and/or scattering. SYSTEM RECHARGE NOTE Determine the cause of system discharge and correct II immediately before performing system recharge. After discharge, inspect the entire system for mechanical damage. If the tank has sustained any mechanical dam- age, it must be hydrostatically tested before refilling. 2. Disconnect the 1/4 in. actuation tubing or the control head from the top of the tank valve. 3. Relieve the pressure from the top chamber of the tank valve by depressing the core of the valve in the valve cap assembly. By performing this operation, the valve will close. t,.Chapter 6 -System Recha F 4 - rg6VZ 4. Slowly remove the valve and siphon tube. If there is any residual pressure left in the tank, it -will bleed out through the pressure relief slot in the valve threads: The complete piping system must be flushed after a discharge. Flushing solution, Part No. 79656, must be used when flushing the system. The solution is shipped in a 32 oz. container. A PCL -300 tank requires 1 contain- er of solution. A PCL -460 requires 1 1/2 containers, and a PCL -600 requires 2 containers. To prepare the system for flushing: a. Pour the required amount of flushing solution into the tank. b. Fill the tank approximately half full with warm, clear water. Agitate the tank for a few seconds and then add more warm water to bring the level -to the required fill line using the measuring stick. Part No. 551039. c. Reinstall valve and pickup tube and pressurize tank to 225 psi and reinstall to piping network. 6. With nozzles in place. attach control head and manually actuate the tank. Allow the tank to completely discharge through the piping network. 7. After the discharge is completed, the entire pipina net- work must be blown out with air or nitroaen until no more mist is visual coming out of the nozzles. 8. Remove. clean. and reinstall all nozzles. 9. Remove the tank from the system. Slowly remove the valve and siphon. If there is any residual pressure left in the tank. it will bleed out through the pressure relief slot in the valve threads. The valve and pressure regulator (located in outlet of valve) must be cleaned and rebuilt after each discharge. To rebuild the valve, use rebuilding kit, Part No. 550698. To rebuild the pressure regulator, use rebuilding kit, Part No. 551061. Each kit includes an instruction sheet listing detailed rebuilding instructions. 10. Fill tank with required amount of Kitchen Knight agent, Part No. 551188, using measuring stick, Part No. 551039. Tank should be filled to a tolerance of—0/=1/8 in. from the mark level on the measuring stick. NOTE During filling, the agent temperature should be 60 °F to 80 °F (16 °C to 27 °C). ULEX 3470 PN551274 October 1, 2001 Chapter 6 = Systern Recharge Page 6=2 11. Reinstall valve and pickup tube and pressurize tank to 225 psi (using ?echarge adaptor, Part No. 551240). Invert the tank after'pre ' ssurizing to clear any air trapped in the pickup tube. Using a soap solution, check for leaks. Reinstall to piping ,network. NOTE The._pressure gauge attached to the tank valve should not be used to determine when the charging pressure has been reached. A pressure regulator must be used. 12. Replace all fusible links by following the instructions list- ed in the Installation Section. 13. Reset control head(s). accessories. pull stations and cas valves by following the instructions listed in the Installation Section. ULEX 3470 October 1, 2001 PN551274ii t