HomeMy WebLinkAboutCORBET DR., 1910 '" <: .~.~ E:'Lr I ~ BREMERTON PE~MIT CENTER 286 4th Street" Bremerton~ WA 98337 Phone: ( 360 ) , 478-5275 FAX; (360) 478-5278 , BUILDING PERMIT Job Addr: 1910 CORBET DR Location: Parcel No: 3786000-009-0302 Permit No: 00..0024 Status: ISSUED Applied: 01/14/2000 Issued: 03/03/2000 Expires:. OtV30/2000 , Applicant:. POSHUSTA, JOHN 360'-377-7214 1910 CORBET DR BREMERTON. WA 98312 Owner: POSHUSTA. JOHN 360-377-7214 1910 CORBET DR BREMERTON. WA 98312 Contractor: SELF Lie tt: SELF Exp: Su-bcontr: ,.[1leso: ADDITION TO EXISTING SFR 1...1.**...1**...******..******************.*-********11_*.*1_***...********************...*. Valuation % Permit fees: 705.50 Total Calculated Fee: 1~062.79 40,000.00 * Plan Check Fees: 352.7(~ Additional. Fees: ,,00 * Oth~r Fees~ 4.50 Total Permit Fee: 1,062.79 . _...*****************************_********************..**********i***********************,**. :MECHANXCAl/PLUMBING FIXTURE$--- MECH-Wt,od/Pell:et Stove.......: 1 ~1ECH"Ci'a$ piping (outlets).... ~ 1 Mf'XH-Heat Pl.1mp 0- :3 hp".."...: 1 HECH-RaftS.,<e Hood (-res)........r. 1 PlJ5!.G-Wiater Closet...,.....'.....: i P1.l3l!d3at.htub......"...,,".......: 1 Pf.BG-lav<i:eOyy.... .'....." ."....: 1: PlBG-"$hr.'..wer..." ~...""..."... ;': 1, PLBG-Ki'tcherl Sink.".....,.".,,: 1 PlBG;~OishwasheY".."" . ."... .. .... r. 1, PLBG--LaundYy TyS:Y.............. t. 1 Pl'eG-Clothe'$ Wa.$he)'............: 1 PLBG-Watey Heater... n. . .. . . . . : 1 PlBG-Fl.:;oy 5i nk/oY$!.lri.. . . . ... . : 1 PleG-Roof Ondns.............,: 1 * * )!"i()I(){()/( *** *)1( * * *)1( * ** * * *,)1()1( *)1()1:: lfCIOK** ***)1( ***** *)1( * * :/i*l!()I( *::4()I:;:I( **)/()I( * lI<)!(:t()!(:I()j( * *lli *)1()(( *)I()\( * *)!( * * *)\(* **)1( * *)/( *)\()(< * ** 1'hi$p~rrr(it sh$.l1 become null and void if the building 0'( wod: authoYized by this pehnit is not. cOffif1W'nced ,wit.hin, 180 days fyOM tht'l chid:,/? of such pel"mi.t.. OY if this building OY wot'k $.uth(,Yi:ted by such p\~rmit 1.s suepended or abarrjtmed at, any time after' thb!> w.;,y'k 1$ comw.mced for' a period of 180 days. .NOTICE - It is t.he responsibility of the perinit holder. not. the City of Bro..'OWyton or BuildJng Offic~.al to see . to it. t.l1ai:: requ,iYed in",p~.tction$ aye ffro:l.de.. The paymil holdeY must notify the Build:l.ng Official when n;ad>' fOr' in$j:)ecth)!'1s.. Failure of l~he penoit holder to notify the Bu.ildir19 Official of requiyed inlSpection$ may yesult , 'in the st.QPpa$e of the woyk uf'ttil $lJ.ch time that tre permit holdey can substantiate to the building official that the c()flcealed wo)'k me0te m' exceeds code r~qui,remer,t$. Any demcJliticn, t.e$tins., 0)' fina:nc:ial buYden shall . b(#' borne eli Yecth' b>' the pe:rmi t holde'r'. Pailuni~ to substantiate code yequi n;ment,~ will ,. nderrlni fy the City a~inst li\T1Y and all nilsPo1'1sibility or liability cormected with the <;xm~d::)'uction. t.rue state' c:ont.Y$.ctoY"$ reS,listration la.",I, \.I11'::'.er ~_.-:_________ "oa.;: __..___;;-____-----:'..,_:___.__ Da t e: --::1..-::"_2__~.(5 D :",,~,....<....' "~. ~ 'J?:{,;~ ',~J~" U" (~ \ ) BREMERTON PERMIT CENTER 286 4th street$ Bremerton$ WA 98337 " Ph,one-: (360) 478-5?:75, FAX: (360) 478-5;1:78 ,,";~~t: Building Job -A~ress: 1910,; CORBET DR L.,ocation": ' ~ Assr Acct.'No: 3786000-009-0302 , I t€im :. Item: Item: Item: , Item: .' Item:. Item: :U,em: ~'~t.. . " R E QUI RED INS P E C T I 0 N$ ~:j,-/~ 'j, ~D Permit No:' 0'0~'0024 . Status:. ~ ISSUED <1 ssued: 03/03/2000 Expires: 08/30/2'000, Division: Division:. Division: Division: Division: ' D1visi(,)n:' Division: Division: ,*~******************************************************************************* TESTING: Must be recognized by the Washington Association of Building Officials SPECINSP: Must be registered with the State of WA ST 'OF WA: State of WA Dept. of labor and Industries HEALTH:: Brem6rton/Kitsap Health Dist.rict 01100 01200 01400 01600 01700 0180t) 01900 02700 FOUND~TION-FOOTINGS \ FOUt"':DATION-WALLS MECHA\'IJICAL PLUMBING ROUGH-IN FRAMIN'~ INSULA1ION SHEETR~:CK NAILING F J NAL "'-1.BLDG SLDG BLDG 8LOG SLDG SLDG SLDG SLOG SLDG 478-4921 478--5235\ ';~~, ...-~.,,#f(i:,,"'f>!.'!J~"'i' '.., ~." '0'" c..-.L- "''''''''''l..\ <" ;.0" ALL INSPECTIONS PERFORMED BY THE CITY OF BREMERTON MUST BE SCHEDULED THROUGH THE . Pf:PI'HT CENTER, (360) 478-5275" . *****. '*. . *. **** ('*4**********~*~' **. ********************************:*'*\***************7 'Permit HOl--:er/s, - '2- 0 519"aJUrer- , _, - _' ______ Date'_...L-:3:;ZQ;l~~ Dept~ Dept: Dept: Dept, Dept.: Dept: Dept: Dept, : ,,* . ~-;, ~\li '~~~ \ \ ,,'. ,'\, C,.I_.r I rZA:;lJ ",~~^1.5:-~':::::.:~e;;:.,~;::::;.r.::..: ~';;::'z,::;, =,:,:=': ~ ~=::;x:=%~;:c; =:::: ~'-:"'''1.:;;:"!Z.~':: ::;;:::-::::.::;:;::::;;:r:: ~=;:;::~::::'::. =:.::::::=~ ~'ZC=:::.:::::: =~ ~;;:::t;:;:.:=:.;=. t::::'~ 'Zt.";h':.=::::::::::: ;,"~;: -::::. =11:: =.t;: ;::,:;:::;: =:== ::::. BREMERTON PERMIT'CENTER PERMIT CONDITIONS Permit No: OO~0024 :1':;:: P<.')ge: 1 ,~=~=========:========.=~====~====,=====~========~==~==========================~= ',V Job Addressl 1910 CORBET DR Assy' Acct No:' 3786000-009~0302 L.ocation: Applied: 01/14/2000 \ APprove>-g :.., 03/03/2000 Issuea;~03/03/2000 Applicant: POSHUSTA, JOHN Owner: POSHUSTA. JOHN ContY'8ct:-or: SELF DescY'iption: ADDITION TO EXISTING SFR ,'Conditions: 1. BLJIU>ING--APPROVED l~/ REVISIONS DENOTED ON PLANS.. ,', i::.... ,',-:3.. B'U1I L D I NG.APPROVED WITH ATTACHED CHECKLIST AND/OR NOTtE;;~ ON PLANS.. , ~MO:~;~ DETECTORS m::OUIRED IN ALL' Sl_EEPING AREAS, ADJPiC.:ENT HALl.tWA YS AND FLOOf< LEVELS.. .' ' ',' , ' 4,. l~IN,b;bws IN SLEEPING AREAS MUST MEET EMERGENCY EGReSS REJ4c(J~REt1ENTS .. B Date~"~-=,~~2J;iiq :', , ~ '.i' ',,\ , .,' *" ...,/ , '.IJ. ~ ,. 'J:, , -" '. PERMIT CENTER 286 Fourth Street, Bremerton W A 98337 Phone: (360)478-5275 Fax: (360)478-5278 RESIDENTIAL PLAN REVIEW CHECKLIST OWNER:~htl\ rOShGL<;~ CONTRACTOR: n u.JV\e-f SITE ADDRESS:! q I D C.lJ ( b e:f Qr .PERMIT # \\ 0 nOD (~1::.. PLANS EXAMINER: S L DATE:-L=-L4- - 0 0 ...,...199'7uNIFORMBmLDINGttODE(t,IBC)...,..."..,...,.................'......'.'.'.....r.....,...,..'......,.. ...,.............................'................ ... .......i997uMFbtOO:M~cHANicAbc6n~tUM:G}........'.'.......'.......'.....",yr'.....'..'.. '...',..'.............,.,...,.'........'......'... .' ..,...,i997'{!~9~1'~~~~qp~i(Y~~)....'.'......'...........,.'...,....r..i....Jm........i.. .......'.'...'..'.'.'.....,.'..'.'..............," , ... ..,n.l~~7.'W'#.~G~91'f~~~~~l!1~g(;~q9R#fW$,~(:lm.~4€?1-.d!........,.,...........'....,.....'...'..........'...". !.....' ....1?97.WA$lIffl(:rr(jrfST~T:i<:y$Nrm;t\T~6i\{AN:D.~OQR1\$QUA[tjjiMCq:Dj15..........,....." n(W$YJ.A.Qj,-JrA9~i.4~../n , n, nnnnnn nn ,n'nn,nn, , nwnn n, 'n, , , ". . . . . ..........-. n. ........ ....... ..... ..... ...................... ............ ... ._. ..... .......... ........ ........_....... ...... ...._.......... ............... n... .................. n. o . . _ . . .....,.. n... .. .. ....... ...._...... ..... . . ..._....................... ....... .. .... .. . .... ._....... '. ....... ........... .............. .......... ... ............. .... . ..........._........... . .... ... ......... .... . ..... .................... ........ ............................. .... ............... .... ...... ..... ................ ......-. ...................--....... ........... ....... . - -. -.... ... ...... ...-.... .... ........ . ......... ...--.. ...... ........ ...... ............ ... ............... .... ....-...... ........ ..................... ....................... ..... ..................... .... .. .... . .... ........ .................. ................ ............... .... ............ ........-..-.... ......... .......... ............. ....... ......................... ......-.............. .. .... ....- . .... ..... .... ......-- .... .... ..............-............ ......... ........ ....-.... ................ ................ .... ............ .... ................. ........ . . . . ... ..... .. -.... . ..... . ........-........ -... .... ................. ........ ....... ................. ...... .......................-.. ....... .. ............. ............... ........ . ..- . .. .I1.......~7iiteef::g~ff;jftJrlt!:!~~Blfktff-~~fdt~1~~..~?~~.:'jf~.!iJqi1).."!iJ.tbs~.p~r'..,............ The numbered items on the following pages are associated with the above referenced codes, as adopted by the City of Bremerton. This checklist is submitted as information only, and shall not be construed as an all-inclusive list of code requirements. Office hours are from 8:00 a.m. to 5:00 p.m. Monday through Friday. Inspections . can be scheduled by calling 478-5275 before 9:00 a.m. one business day in advance. You must know your permit number when requesting an inspection. ", 1. FLOOR PLAN 1. ROOM IDENTIFICATION: UBC Section 106.3.1 Each room and the intended use must be clearly defined on the plans by the applicant for plan review purposes. 2. EGRESS WINDOWS: UBC Section 310.4. All sleeping rooms and basements are required to have egress windows. The window shall have a minimum net clear openable area of 5.7 square feet. The minimum net clear openable height dimension shall be 24". The minimum net clear openable width dimension shall be 20". The window shall have a finished sill height not more than ..J.4" above the floor. Window wells shall be provided when egress windows have a finished sill height belO\v adjacent ground elevation. The well shall allow the window to be fully opened and provide a minimum accessible net clear opening of 9 square feet with a minimum dimension of 36". Window wells with a vertical depth of more than ..J...J." shall be equipped with a permanent ladder. Refer to handout for additional information. 3. SMOKE DETECTORS: UBC Section 310.9.1. A detector shall be installed in each sleeping room and at a point centrally located in the corridor or area giving access to each separate sleeping area. Where the ceiling height of the room open to the hallway serving the bedrooms exceeds that of the hallway by 24" or more, smoke detectors shall be installed in the hallway and in the adjacent room. Each floor and basement shall have at least one detector. Required smoke detectors shall receive their primary power from the building wiring and shall be equipped with a battery backup. Detectors shall be interconnected to provide audibility in all areas. When the valuation of an addition, alteration or repair exceeds $1.000 and a permit is required, smoke detectors shall be installed (E.:\:ception: Repairs to tlie exterior surfaces of a Group R occupancy are e..l:empt from these requirements). 4. SAFETY GLAZING: UBC Section 2406.4. All glass located in an area which the UBC considers hazardous must be safety glazed : 1. Glazing in ingress and egress doors. 2. Glazing in sliding door assemblies and panels in swinging doors (wardrobe doors excluded). 3. Glazing in storm doors. 4. Glazing in all unframed swinging doors. 5. Tub/shower enclosures and any glazing in a wall enclosure within 60" of standing surface. 6. Glazing in any opening adjacent to a door within 24" where the bottom is less than 60" above the walking surface. 7. Glazing that meets all of the following conditions: A. Exposed area of an individual pane >9 square feet. B. Exposed bottom edge <18" above the floor. C. Exposed top edge >36" above the floor. D. 1 or more walking surfaces within 36" horizontally of the plane of the glazing. 8. Glazing in railings See code for exceptions for Items 1 through 8. <). Glazing in walls and fences used as the barrier for indoor and outdoor s\vimming pools and spas when all of the following conditions are met: 9.1 The bottom edge of the glazing is less than 60 inches above the pool side of the glazing. 9.2 The glazing is within 5' of a swimming pool or spa's water edge. 10. Glazing in walls enclosing stairway landings or within 5' of the bottom and top of stairways where the bottom edge of the glass is less than 60" above a walking surface. UBC Section 2406.6 Glass Railings. Glazing in railings shall be one of the following: . Single fully tempered glass. · Laminated fully tempered glass. · Laminated heat-strengthened glass. l'-'or all types, the minimum nominal thickness shall be 1/-1 ". 5. NATURAL LIGHT & VENTILATION: UBC Sections 1203.2, 1203.3. Habitable rooms shall be provided with naturallie,ht by means of exterior glazed openings with an area not less than one tenth of the .floor area of such rooms with a minimum of 10 square feet. Habitable rooms shall be provided with natural ventilation by means of openable exterior openings with an area of not less than one twentieth of the jloor area of such rooms with a minimum of 5 square feet. 6. EXHAUST FANS: WSVlAQ Section 302.2.1. Exhaust fans are required in each kitchen, bathroom, water closet room, laundry facility, indoor swimming pool, spa and other rooms where excess water vapor or cooking odor is produced. UBC SectionI703.3. The point of discharge 1 of exhaust air shall be at least 3' from any opening into the building or property line (this includes dI}'er exhausts and kitchen range hoods). See energy section of this checklistfor more specific requirements. 7. CLOTHES DRYERS: UNIC Section 504.3. Clothes dryer exhaust ducts shall terminate outside the building, and be equipped with a backdraft damper. Ducts shall not be connected with sheet metal screws or other fasteners which \vill obstmct the flow. Duct length shall not exceed a total combined vertical and horizontal length of 14', including 2 900 elbows. Two feet shall be deducted for each 900 elbow in excess of 2. Approved flcxible duct conncctors not more than 6' in length may be used, provided they are not concealed within constmction. 8. RANGE HOOD: UNIC Section 906. The vertical distance between the cooking top of a domestic range and the hood shall not be less than 30". Refer to WSVL4Q Section 302.1 & Table 3-1 for more specific requirements. 9. WATER CLOSET CLEARANCES: UBC Section 290'+. Water closet shall be located in a clear space not less than 30" in width. The clear space in front shall not be less than 24". 10. SHOWER AREAS: UPC Section '+12.6,412.7. All showers shall have a minimum finished interior floor area of 1024 square inches and shall also be capable of encompassing a 30" circle. These dimensions shall be maintained to a point 70" above the shower drain outlet. Threshold shall be of sufficient \yidth to accommodate a minimum 22" door. It. FACTORY BUILT CHIMNEYS & FIREPLACES: UBC Section 3102.5.1. Factory-built chimneys and fireplaces shall be installed per the terms of their listings and the manufachlrer's instmctions as specified in the UMC. 12. TIGHT-FITTING DOORS (FIREPLACE): WSVIAQ Section 402. Solid fuel burning appliances and fireplaces shall be provided with tight-fitting glass or metal doors. An outside source of combustion air shall be ductcd to the firebox. 13. FIREPLACE HEARTH EXTENSION: UBC Sections 3102.7.11, 3102.7.12. An approved noncombustible hearth must exiend at least 16" from the front of, and at least 8" beyond each side of the fireplace opening. Where the fireplace opening is 6 square fect or larger, the hearth exiension shall exiend at least 20" in front of, and at least 12" beyond each side of the fireplace opening. 14. CLEARANCE TO COMBUSTIBLES (FIREPLACE & CHIMNEYS): UBC Section 3102.3.3 & Table 31-B. When masonry chimneys are built within a stmcture. a 2" clearancc to combustibles is required. When the chimney is placed on the exterior of the structure, a 1" clearance is allowed. UBC Section 3102.7.8. Combustible matcrial shall not be placed within 6" of fireplace opening. No combustible material placed within 12" of the fireplace opening (such as mantles or decorative fireplace surrounds) shall project more than 118" for each 1" clearance from tlle opening. 15. COMBUSTION AIR: UNIC Chapter 7. In buildings of unusually tight constmction, fuel-burning appliances shall obtain combustion air from outside (excluding' cooking appliances and clothes dryers). 16. APPLIANCE LOCATIONS: UNIC Section 304.5. UPC Section 1309. Fuel burning warm-air furnaces or water heaters shall not be installed in a bedroom, batllroom, closet or in any enclosed space with access only through such room. Exception: direct vent appliances. 17. APPLIANCES LOCATED IN GARAGE: UPC Section 510.2, UMC 303.1.3. Heating and cooling equipment and water heaters installed in garages shall be guarded from damage when located in the normal vehicle path. When such equipment generates a glow, spark or flame capable of igniting flammable vapors, it shall be installed Witll sources of ignition at least 18" above the floor. 18. WATER HEATER: UPC Section 510.5. Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. UPC Section 608.5. Temperature and pressure relief valves shall be drained to outside. Drain may not be trapped and must tenninate no more than 2' nor less than 6" from the ground. WSEC Section 504.2.1. All electric hot water heaters shall be placed on an R-1O pad when located in an unheated space or on a concrete floor. 19. L.P,G. (PROPANE) APPLIANCES: UNIC Section 304.5. L.P.G. burning appliances shall not be installed in a pit, basement or similar location where heavier-than- air gas might collect. Appliances so fueled shall not be installed in an above-grade under-floor space or basement unless such location is provided with an approved means of removal of unburned gas. UNIC Section 304.7. Containers for storage ofL.P.G. shall be installed in accordance with the Fire Code. 20. MANUFACTURER'S SPECS: UNIC Section 302.1. The installer shallleave the manufacturer's installation and operating instmctions attached to the appliance. 21. VACUUM BREAKERS: UPC Section 603.3.4. Potable water outlets \,yith hose attaclmlents other than \vater 2 heater drains and clothes washer attachments shall be protected by a listed non-removable backflow preventer. 22. TRAP PRIMERS: UPC Section 1007. Floor drains or similar traps connected to the drainage system and subject to infrequent use shall be provided \\'ith an approved automatic means of maintaining their water seals. 23. GARAGE/DWELLING DOOR: UBC Section 302.4. The door between the dwelling and garage must be self- closing and either 1-3/8" solid wood or have a 20 minute rating (labeled). Unrated metal doors will not be accepted. 2-l. GARAGE/DWELLING SEPARATION: UBC Section 302.4 Exception 3. The required I-hr fire-resistive construction between a garage and a dwelling as set forth in table 5-A has an exception that allows the I-hr fire- resistive construction to be limited to the garage side topically 5/8" Type '~:r" gypsum wallboard}. Section 302.2 requires that where the occupancy separation is horizontal (ceiling), structural members supporting the separation shall be protected by equivalent fire-resistive construction (this includes all supporting walls). There shall be 2 layers of 5/8" Type "X" GWB applied to the ceiling when framing members are 24" on center. 25. SEPARATION BETWEEN DWELLING UNITS: UBC Section 310.2.2. Walls and floors separating dwelling units in the same building shall not be less than l-hr fire-resistive construction. 26. FIRE-RESISTANCE OF EXTERIOR WALLS: UBC Table 5-A. I-hr fire-resistive construction required \',ithin 3 feet of property lines. openings not permitted less than 3'. For apartments, the requirement is 5' for both. 27. FLOOR AREA: UBC Section 310.6.2. Dwelling units shall have at least one room with not less than 120 square feet of floor area. Other habitable rooms except kitchens shall have an area of not less than 70 square feet. Section 310.6.3 requires that habitable rooms other than a kitchen shall not be less than 7' in any dimension. 28. MINIMUM CEILING HEIGHTS: UBC Section "110.6.1. Habitable spaces shall have a ceiling height of not less than 7'6" except for kitchens, halls or bathrooms ,"vhich may be no less than 7'. 29. ATTIC ACCESS: UBC Section 1505.1. Attics with a minimum vertical height of 30" must be provided with minimum access openings of not less than 22" x 30" and located in a hallway, corridor, or readily accessible location. 30. DOORS: UBC Section 1003.3.1.3. At least 1 doorway shall be of a size as to permit the installation of a door not less than 3' in width and not less than 6'8 " in height. The door shall be mounted so that the clear net width is not less than 32". 31. LANDINGS: UBC Section 1003.3.1.7. 1003.3.3.5. There shall be a floor or landing on each side of all doors. The floor or landing shall be not more than I" lower than the threshold of the doorway. In private dwellings, an interior door may open on the top of a flight of stairs or on an exterior landing, provided the door does not swing over that top step or exterior landing (except that sCreen and storm doors mG.];') and the landing in not more than 8" below the floor level. Where a door opens over a landing. the landing shall have a length not less than the width of the door. Exterior landings may have a slope not to exceed 1/4" per foot. Landings shall have a length measured in the direction of travel not less than 36". 32. GUARDRAILS: UBC Sections 509.1,509.2,509.3. Stairs, landings, ramps, balconies or porches which are more than 30" above grade require guardrails. The top of the guardrail shall not be less than 36" high (./1" when other than individual dwelling units). Open guardrails shall be designed such that a sphere 4" in diameter cannot pass through. 33. HANDRAILS: UBC Section 1003.3.3.6. All stairways with -l or more risers shall have at least one handrail. Such handrails shall be placed not less than 34" nor more than 38" above the nosing of the treads. The handgrip portion of the handrail shall not be less than 1-1/4 " or more than 2" in cross-sectional dimension. Handrails may project into the required stair width a distance of 3- 1/2". There shall be a space of not less than 1-1/2" between the wall and the handrail. Refer to handout. 34. STAIR WIDTH: UBC Section 1003.3.3.2. Stairways serving an occupant load of 49 or less shall not be less than 36" in width. 35. STAIR RISE & RUN: UBC Section 1003.3.3.3. Private stainvays serving an occupant load of less than 10 may be constructed with an 8" maximum rise and a 9" minimum run (7" and ll"for all others). No riser can be less than 4". The largest tread run may not exceed the smallest by more than 3/8". The greatest riser height may not exceed the smallest by more than 3/8". 36. STAIR HEADROOM CLEARANCE: UBC Section 1003.3.3.4. Every stairway shall have a headroom clearance of not less than 6'8". See exceptionfor spiral stainmys. 37. USABLE SPACE UNDER STAIRS: UBC Section 1003.3.3.9. The walls and soffits of enclosed usable 3 STRUCTURAL SPECIFY FOUNDATION FOOTING SIZE: UBC Section 1806.1 and Table 18-I-D. · Supporting 1 floor: minimum 6" by 12". · Supporting 2 floors: minimum 7" x 15". · Supporting 3 floors" minimum 8" x 18". space under stairs shall be protected on the enclosed side by not less than 1-hour fire-resistive construction. 38. WINDING STAIRWAYS: UBC Section 1003.3.3.8.2. \\:/inding staiC\Vays shall have no width of run less than 6" and a required width of run (9'') provided at a point 12" from the narrow side. . 40. 41. FOOTING REINFORCEMENT: UBC Section 1907. As a minimum standard, refer to the attached handout: Prmrij)tive Foundation ReinfOrrement Requirements, as provided by the Olympic Peninsula Chapter of lCBO. 42. SPECIFY FOUNDATION WALL SIZE: UBC Table 18-I-D. · Supporting 1 floor: minimum 6" wide. · Supporting 2 floors: minimum 8" wide. · Supporting 3 floors: minimum 10" wide. 43. FOUNDATION WALL REINFORCEMENT: UBC Section 1907. As a minimum standard, refer to the attached handout: Prescriptive Foundation ReinfOrcement Requimneents, as provided by the Olympic Peninsula Chapter of lCBO. Walls exceeding 8' in height must be designed and stamped by a design professional licensed with the State of Washington. 44. SPECIFY FOOTING DEPTH: crBC Secrion 1806.1 and Table 18-I-D. · Supporting 1 floor: 12" below grade. · Supporting 2 floors: 18" below grade. · Supporting 3 floors: 24" below grade. 45. SPECIFY FOUNDATION WALL HEIGHT: UBC Section 1806.1. Wall must extend at least 6" above grade. \,/alls exceeding 8' in height must be designed and stamped by a design professional licensed with the State of Washington. 46. ANCHOR BOLTS: UBC Section 1806.6. Bolts shall be not less than 1/2" diameter, embedded at least 7", spaced no . more than -1-' apart. There shall be a minimum 'of 2 bolts per piece (sill plate), with 1 bolt located within 12" of each end of each piece. A properly sized nut and washer shall be tightened to the plate. 47. DA.iVfP-PROOF FOUNDATION WALLS: UBC Section 1402.4. Foundation walls enclosing a basement 39. SPIRAL STAIRWAYS: UBC Section 1003.3.3.8.3. Spiral stairs may be used for exits when the area served is limited to -1-00 square feet. The tread must provide a clear \valking area measuring at least 26" from the outer edge of the supporting column to the inner edge of the handrail. A run of at least 71/2" is to be provided at a point 12" from where the tread is the narrowest. The rise must be sufficient to provide 6'6" headroom. The rise of the steps shall not exceed 9 1/2 inches. below fmished grade shall be damp-proofed on the outside by approved methods and materials. -1-8. PIER PADS: UBC Table 18-I-D. Same as footings. 49. FOOTING /PIER SETBACK FROM SLOPE: CBC Section 1806.5.3. Footings adjacent to slopes shall be founded in firm material with an embedment and setback sufficient to provide vertical and lateral support. See Table 18-I-D. 50. CHIMNEY FOUNDATION: UBC Section 312.7.2. When an approved design is not provided, foundations for masonry and concrete fireplaces shall be not less than 12" thick, and meet the depth requirement for a footing. 51. FOUNDATION VENTILATION: UEC Section 2306.7. Under floor-areas must be provided with openings having a net area of not less than 1 square foot for each 150 square feet of under-floor area. Openings shall be located as dose to comers as practical and shall provide cross- ventilation. The openings shall be equally spaced and located on at least 2 sides. They shall be covered with corrosion-resistant wire mesh with openings of 1/4" in dimension. 52. WOOD IN CONTACT WITH CONCRETE At"ill MASONRY: UBC Section 2306.2. Wood embedded in the ground or in direct contact with the earth shall be treated wood. All foundation plates or sills and sleepers on a concrete or masonry slab, which is in direct contact wid1 earth, and sills which rest on concrete or masonry foundations shall be treated wood or foundation redwood. 53. COLUMNS At'ID POSTS: UBC Section 2306.5. Columns and posts located on concrete or masonry floors or decks exposed to the weather or to water splash or in basements shall be supported by concrete piers or metal pedestals projecting above floors unless approved wood of natural resistance to decay is used. The pedestals shall project at least 6" above exposed eanh and at least 1" above such floors. Individual concrete or masonry piers shall project at least 8" above exposed ground unless the columns or posts which they support are of approved wood of natural resistance to decay or treated wood. y 54. GIRDERS ENTERING MASONRY OR CONCRETE WALLS: UBC Section 2306.6. Ends of wood girders entering concrete or masonry walls shall be provided with a 1/2" airspace on tops. sides and ends unless approved wood of natural resistance to decay or treated wood is used. 55. POST-BEAM CONNECTIONS: USC Section 2314. Positive connections shall be provided at post-beam connections to ensure against uplift and lateral displacement. USC Section 1603.3.5. Anchorage of \valls and columns to foundations shall be provided. 56. SPECIFY WOOD SPECIES & GRADES: USC Section 2304.1. All wood used in construction shall confonn to the applicable standards or grading rules of the USC and shall be identified by a grade mark. 57. FLOOR FRAMING: USC Section 2320.7,2320.8. Beams and girders supported by concrete or masonry shall have not less than 3" of bearing. Floor joists shall be supported laterally at the ends and at each support by solid blocking except where the ends of joists are nailed to a header or rim joist or to an adjoining stud or other approved means. Joist framing from opposite sides of a beam or partition shall be lapped at least 3". See Tables 23-I-V-J-1 & 23-I-V-J-2 for allowable spans. 58. BEARING PARTITIONS: USC Section 2320.8.5. Bearing partitions perpendicular to joists shall not be offset from supporting girders, walls or partitions more than the joist depth. Joists under and parallel to bearing partitions shall be doubled. 59. UNDER-FLOOR CLEARANCE: UBC Section 2306.3. When floor joists are located within 18" or beams are located within 12" of the ground in crawl spaces, all components of the floor assembly shall be wood of natural resistanc~ to decay, or treated material. Included are the posts, beams or girders, joists and sub-floor. 60. UNDER-FLOOR ACCESS: USC Section 2306.3. Under-floor areas shall be supplied with a minimmn 18" x 24" opening unobstructed by pipes, ducts or similar construction. 61. WALL FRAMING: UBC Sections 2320.11. Utility grade studs shall not be spaced more than 16" on center, or support more than a roof and ceiling, or exceed 8' in height for exterior and load bearing walls or 10' for interior non-bearing walls. Studs shall be placed with their wide dimension perpendicular to the wall. Bearing and exterior walls shall have double top plates that overlap at comers and partitions. End joints in double top plates shall be offset at least 48". The minimum length of any stud shall not be less than 14". Cutting and notching: may not exceed 25% in bearing or exterior walls, may not exceed 40% in non-bearing walls. Bored holes: may not exceed 4lVYo, except that 60% is allowed in non-bearing walls. See Table 23-I-R-3 for additional infomlation. 62. WALL BRACING: UBC Section 2320.11.3. All exterior walls and main cross-stud partitions shall be braced to resist wind and seismic forces. Walls must be braced at each.end of wall and every 25'. 25% of wall length must be sheathed on the 1st story of a 2 story building, or the 2nd story of a 3 story building. 40% of walllcngth must be sheathed on the 1 st story of a 3 story building. See Table 23-I-W for types of bracing allowed. 63. HEADERS: USC Section 2320.11.6. All openings more than 4' wide shall be provided with headers consisting of either two pieces of 2" framing lumber placed on edge and securely fastened together or 4" lumber. Each end of the header shall have at least 1-1/2" of bearing for the full width. Headers shall be designed to support the loads specified by the UBe. 64. FIRE-BLOCKS & DRAFT-STOPS: USC Section 708. Fire-blocking and draft-stopping shall be installed to cut off all concealed draft openings (both vertical and horizontal) and shall fonn an effective barrier between floors, between a top story and a roof or attic space, and shall subdivide attic spaces, concealed roof spaces and floor-ceiling assemblies. Fire blocking shall be provided every 10' both vertically and horizontally, in concealed spaces of stud walls and partitions and at the ceiling and floor levels, including soffits, drop ceilings, cove ceilings, . stair stringers, around vents, pipes, ducts, chimneys, and fireplaces, and similar openings which afford a passage for fire at ceiling and floor levels. Draft stopping shall be installed so that the area of the concealed space does not exceed 1,000 square feet and completely separates dwelling units. 65. SPECIFY SIDING TYPE: UBC Section 2310.2. Ensure proper fastening for type used, wood siding may not be less than 3/8" thick. 66. WEATHER RESISTIVE BARRIER/SIDING: DEc Section 1402.1. All weather-exposed surfaces shall have a weather-resistive barrierto protect the interior wall covering. The felt or paper shall be applied horizontally, with the upper layer lapped over the lower layer not less than 2". Where vertical joints occur, felt or paper shall be lapped not less than 6". 67. VENEER: USC Section 1403.6.4.2. Anchored veneer shall be supported on footings, foundations or other noncombustible support. Wall ties shall be corrosion resistant and spaced so as to support not more than 2 square feet of wall area but shall not be more than 24" on center horizontally. In seismic zones 3 and 4, anchor ties shall have a lip or hook on the extended leg that will engage or enclose a horizontal joint reinforcement wire 5 NO.9 gauge or equivalent. Joint reinforcement shall be continuous. Anchor ties shall be completely embedded with cement mortar. Weep holes shall be provided at the lowest course. When applied over stud construction, the studs shall be spaced a maximum of 16" on center and 15# felt shall first be applied over the sheating or wires between studs and mortar shall bc slushed into the 1" space between spacing and paper. 68. SIDING/EARTH SEPARATION: UBC Section 2306.8. Wood used within 6" of earth shall be treated or ,yood of natural resistance to decay. 69. DECKS & EXTERIOR STAIRS: UBC Section 2306.12. Uncovered decks, porches or extcrior stairs shall be constructed of approved wood of natural resistance to decay, or treated. Included are joists, beams, girders, decking and posts. 70. TRUSSES: UBC Section 1704. Must be accompanied with engineering data and installation specifications, and must indicate the type of roofing to be used. Specs shall be available on site at framing inspection. 71. RAFTERS: UBC Sections 2320.12.3, 2320.12.6, 2320.12.8. Rafters shall be framed directly opposite each other at the ridge. The ridge board shall be at least I" nominal thickness, and all valley or hip rafters shall be at least 2" nominal thickness. Rafter ties shall be placed not more than 4' on center. See Tables 23-I-V-R-l through 23-I-V-R-12 for allowable spans. Roofrafters and ceiling joists shall be supported laterally at points of bearing by solid blocking to prevent rotation. See Section 2306.7 for type of blocking required. . 72. RAFTER OPENINGS: UBC Section 2326.12.5. Trimmer and header rafters shall be doubled when the span of the header exceeds 4'. The ends ofrafters more than 6' long shall be supported by framing anchors or rafter hangers unless bearing on a beam, partition or wall. 73. CEILING JOISTS: UBC Section 2320.12.8. Ceiling joists shall be supported laterally to prevent rotation at bearing points. See Tables 23-I-V-J-3 & 23-I-V-J-4 for allowable spans. 74. SPECIFY ROOF SLOPE: UBC Table 15-B-l & 15-B- 2. Must be indicated on plans to ensure selected roof covering is allowed on designed pitch. 75. SPECIFY ROOF COVERING: UBC Section 1507. Selected roof covering must be specified and installed in accordance with manufacturer's specifications in addition to UBC requirements. 76. ATTIC VENTILATION: UBC Section 1505.3. Enclosed attics and rafter areas shall be supplied 'with cross-ventilation. The net free ventilating area shall not be less than 1/150 of the area of the space ventilated, unless 50% of the ventilating area is provided from the upper portion of the space to be ventilated, then 1/300 is allowed. 77. CHIMNEY HEIGHT: UBC Table 31-B. Must terminate at least 2' above any part of building within lO'. GENERAL 78. PREMISES IDENTIFICATION: UBC Section 502. Address shall be provided in such a position as to be plainly visible and legible from the street fronting the property. 79. APPROVED PLANS: UBC Sections 106.4.1, 106.4.2. The approved plans shall not be modified, changed or altered without authorization from the Building Official. The building permit and one (1) set of approved plans for the project must be kept on site at all times during which the work authorized thereby is in progress. 80. HEATING: UBC Section 310.11 Every dwelling unit and guest room shall be provided with heating facilities capable of maintaining a room temperature of 700 F at a point 3' above the floor in all habitable rooms. 81. SKYLIGHTS: UBC Section 2409.2,2409.3. All skylights must be laminated glass under tempered glass, unless provided with screens. Exception: Laminated glass need not be provided within individual dwelling units when fully tempered glass is used as single glazing or in both panes of an insulating glass unit when all the following conditions are met: · The area of each pane (single glass) or unit (insulating glass) shall not exceed 16 square feet. · The highest point of the glass shall not be more than 12' above any walking surface or other accessible area. · The nominal thickness of each pane shall not exceed 3/16". 82. GYPSUM WALLBOARD: UBC Section 2512. When gypsum is used as a base for tile or wall panels for tub/shower enclosures, water-resistant gypsum shall be 6 used. Water resistant gypsum wallboard may not be used over a vapor retarder, or on ceilings where frame spacing exceeds 12" on center. 83. GYPSUM WALLBOARD NAILING: UBC Tables 25- G & 25-H: · 3/8" minimum from edge and ends for nails or screv..s. · Fastening (nails): 7" o.c. max. ceiling, 8" walls. · Fastening (screws): 12" o.c. ceiling, 16" o.c. walls when wall framing is 16" o.C., 12" when wall framing is 24" o.C. 84. FIRST STORY: UBC Section 220. The first story is the lowest story in a building which qualifies as a story, except that a floor level in a building having only one floor level shall be classified as a first story, provided such floor level is not more than 4 feet below grade for more than 50% of the total perimeter, or not more than 8 feet below grade at any point. 85. HEIGHT OF BUILDING: UBC Section 209, Table 5- B. Single-family residences or duplexes shall not exceed 40' in height. Height shall be measured from the ground to the highest point of a flat roof or the deck of a mansard roof or to the average height of the highest gable of a pitched roof on a flat lot. On a sloped lot, height is measured from the highest ground level within 5' of the exterior wall, provided this ground level is not more than 10' above the lowest grade. If the highest grade is more than 10' above the lowest grade, the height of the building is determined by using an elevation 10' higher than the lowest grade. Note: Zoning regulations may limit the height of residential structures more stringently. Check with your local jurisdiction for height limitations. 86. RETAINING WALLS: UBC Section 1609.2. Shall be designed to resist the lateral pressure of the retained material in accordance with accepted engineering practice. ENERGY CODE 87. FOUNDATION INSULATION: WSEC Section 502.1A.8. Slab-on-grade insulation, installed inside the foundation wall, shall extend downward from the top of the slab for a minimum distance of 24" or downward and then horizontally beneath the slab for a minimum combined distance of 24". Insulation installed outside the foundation shall extend downward to a minimum of 24" or to the frostline. Above grade insulation shall be protected. For monolithic slabs, the insulation shall extend downward from the top of the slab to the bottom of the footing. 88. UNDER-FLOOR INSULATION: WSEC Section 502.1.4.7. Floors over unconditioned spaces, such as vented crawl spaces, unconditioned basements and garages shall be insulated to not less than the nominal R-value shown for floors over unconditioned spaces on the energy code application for compliance option chosen. 89. WALL INSULATION: WSEC Section 502.1.4.6: Above grade exterior walls shall be insulated to not less than the nominal R-value as specified on the energy code application for the compliance option chosen. See Chapter 6 Tables. Faced batts shall be face-stapled (not inset-stapled), to avoid compression. 90. ATTIC INSULATION: WSEC Section 502.1.4.5. Ceilings below vented attics shall be insulated to not less than the nominal R-value shown for attics on the energy code application for the compliance option chosen. See Chapter 6 Tables. 91. VAULTED CEILING INSULATION: WSEC Section 602.1. Vaulted ceilings shall be insulated to not less than the nominal R-value shown on the energy code application for the compliance option chosen. See Chapter 6 Tables. WSEC Section 502.1.6.3. Vaulted ceiling cavities shall be of sufficient depth to allow a minimum 1" vented air space above the insulation. Faced batts shall be face-stapled (not inset-stapled). 92. HATCHES AND DOORS: WSEC Section 502.1.4.4. Access doors from conditioned to unconditioned spaces (attics and crawl spaces) shall be weather-stripped and insulated to a level equivalent to the insulation on the surrounding surfaces. 93. DUCT INSULATION: WSEC Sections 503.9,503.10 & Table 5-11. All heating ducts within unconditioned spaces shall be insulated to R-8. Ducts installed under slabs shall be insulated to R-5. 94. PIPE INSULATION: WSEC Section 503.11 & Table 5- 12. Water pipes outside of the conditioned space shall be insulated to a minimum of R - 3. 7 95. VAPOR RETARDER: WSEC Section 502.1.6. Vapor retarders shall be installed on the wann side (in winter) of insulation. Vapor retarders shall not be required in roof !ceiling assemblies where the ventilation space aboye the insulation averages 12" or greater. 96. VAPOR BARRIER IN CRAWL-SPACE: WSEC Section 502.1.6.7. A ground cover of 6 mil black polyethylene shall be laid over the gromld within crawl . spaces. The ground cover shall be overlapped 12" minimum at the joints and shall extend to the foundation wall. The ground cover may be omitted in crawl spaces if the crawl space has a concrete slab with a minimum thickness of 3-l/2". 97. WINDOWS: WSEC Section 502.1.5 & Tables 6-1 through 6-6. The required V-value for windows will be detennined by calculating the percentage of glazing desired. Brand, model and V-value must be stated on energy application. Any change in windows must be approved by the Building Department before . installation. NFRC compliance stickers shall remain on the windows until the framing inspection has been approved by the Building Department. 98. EXTERIOR DOORS: WSEC Sections 502.1.5.2, 602.6. Doors which are more than 50% glazing shall be considered vvindows for the purposes of energy code requirements. All other doors shall comply with V- value shown for compliance option chosen. 99. EXHAUST FANS: WSVIAQ Table 3-1: Ml~HIL\I SOURCE SPECIFIC VENTIL.\.TION CAPACITY REQUIREMENTS TABLE 3-1 LAUNDRY KITCHENS OR BATIIROO:\1 s Intermittently SO cfm 100 cfm Operating Continuous 20 cfm 25 cfm Ooeration NOTE: ALL FANS SHALL PROVIDE THE REQUIRED FLOW WHEN TESTED AT .25 WATER GAUGE. Fk~S LARGER THAL", THE ABOVE PRESCRIPTIVE SIZES "'L\.Y BE :'iECESSARY TO ATTAIN THE REQUIRED j<'LOW. 100. WHOLE HOUSE FAN: WSVlAQ Section 302.2.2, 302.3.2, 302,{. Each dwelling unit shall be equipped \vith a whole house ventilation system which shall be capabkofproviding at least .35 air changes per hour, but not less than 15 cubic feet per minute per bedroom plus an additional 15 cubic feet per minute. This fan shall have an automatic and manual timer. Fans shall have a flow rating at 0.25" water gauge and a sone rating of 1.5 or less measured at 0.1" water gauge. WHOLE HOUSE EXHAUST FAN PRESCRIPTIVE REQUIREMENTS Table 3-2 Number of CFM CFM Bedrooms Minimum Maximum 2 or less 50 75 3 80 120 -4 100 150 5 120 180 101. VENTILATION DUCTS: WSVlAQ Section 302.5. All ducts shall terminate outside the building. Fan ducts shall be equipped with back draft dampers and shall be insulated to a minimum of R -4 in an unconditioned space. 102. WINDOW OR WALL PORTS: WSVlAQ Section 302.6.2. Individual room outdoor air inlets shall have a controllable and secure opening and be capable of a total opening area of not less than -4 square inches. 103. DISTRIBUTION: WSVIAQ Section 302.6.4. Where outdoor air supplies (window or wall ports) are separated from fan locations by doors. adequate air flow shall be ensured by undercutting doors or installing grilles or transoms. Doors shall be undercut to a minimum of 1/2" above the surface of the finished floor covenng. 104. MAKE-UP AIR THROUGH FURt~ACE: WSVIAQ Section 302.6.3 & Table 3-5. The outdoor air connection to the return air stream shall be located upstream of the forced-air system blower and shall not be connected directly into a fl.lrnace cabinet. . 8 PERMIT CENTER 286 Fourth Street, Bremerton WA 98337 Phone: (360)478-5275 Fax: (360)478-5278 20" CLEAR ~ MINIMUM J ~ . 34"CLEAR J . . ~...~.. . . / OPENABLE . AREA . 41" CLEAR . . . . . . ... ~LE.... 5.7 SQ. FT. MINIMUM . . . . . . . .. . .. AREA 5.7 SQ. FT. .... MINIMUM .... . . . . 24" CLEAR MINIMUM MINIMUM SIZE VVNXJN FCA . 20" CLEAR WIDTH MINL\1UM SiZE 'NlNrXJ..N FOR 24" a...EAR HEIGHT SILL HEIGHT 44" MAXIMUM A.O:::R MINIMUM SIZED RESCUE OR ESCAPE WINDOWS FROM SLEEPING ROOMS PERMIT CENTER 288 Fourth Street, Bremerton WA 98337 Phone: (360)478-5275 Fax: (380)478-5278 Acceptable Handrail Details 1 . 1/2" HANDRAIL r 1 1/2'. .minimum /' 2'. maxImum, or equivalent gripping surface min, 111:' MIN. . . ~~ -~ NOTE: . OTHER SHAPES MAY BE ACCEPTABLE IF THEY PROVIDE AN EQUIVALENTGRIPPrNG SERVICE. NOT ACCEPTABLE PERMIT CENTER 286 Fourth Street, Bremerton WA 98337 Phone: (360)478-5275 Fax: (360)478-5278 6'8" MINIMUM HEADROOM HANDRAIL 9" MINIMUM RUN OCCUPANT LOAD LESS THAN 10 (Private Stairway) 6'8" MINIMUM HEADROOM HANDRAIL OCCUPANT LOAD OF 10 OR MORE ~T A.IC'^' A. Vc:. ': ALTElli'f~T.E BR.\CED WALL PAl'iEL (A.B\VP) PER lJBC SECTION 2326.11.4, ITENf 1: ~ STRUCTURE DETAIL HEADER /' L-=--=--=--=- \ .. \ I 2" X_ STJCS - .\f.A IL SHEA THING -J ,~:"L S~JCS & PU TcS 'H/ 8d ::~eN OR GALlI. BOX ,I.U.ILS 9 3" OIC ~ ECGES & 12" ~ OIC ~ :,'r;"e,:;:_\,jECJ2:~ Ie SUPFCRTS AND ::..O(~=O ~T ~LL PLYHCCO ~=c=s- T~3L= Z3-I-Q z- L/2"XfO" ANCHOR ~ClTS '~TH 7~ MI~ :NBEC~E~T AND PLACED 9 PANEL ONE QUARTER PO I HTS 2- NO. 4- REFCRCE.l.1ENT BARS ,I.1IN GruCE #J e 3" ,4I~ FRa.l r:COTVK BOTTa.l ( 12",4IN LAP ~ SPLICE ) h 32 INCH MIN - IF LESS ~ ENGINEERING IS REOUIRE~ _ I OVER 4- FT- ABWP NOT REQ.--t ------------- ~ 2 - rx _ TOP PLAI::S NAIL SHEATHING TO EAC, PLA TE WITH 3d Ccu.+cN CR GALV. BOX ti 6" eN CElli.: Tll,! ----n-----:i I I I I I I I I I I ! I I r I I I I I ! I ) ! , I I I I 1 I I I I I I ! I I I I I I j I I I I I i I I I I 1 I I , I I I I I I I WALL ASSENBL Y MAX HEIGMT 10 FT TO TOP OF PLA IE !>C'i.3/8" A.P.A. ~TEJ PL'tWeCO SHEA THING eN ONE SIeE OF WAL:.. APPROVED STt=L HOLD CC~NS IN CONCRETe (1800 La ~I~ UFLIFT CAPACITY) INSTALL== PER ,4ANUFACT0REO S?ECS i - Z";c PLATE (BOTTCM PLA TE PRESSURE TREATeD) NAIL SHEAHlING TO EACH PU TE 'HIT:--f 8d CC~N CR GAL'I. BOX e 6" ON ( c:'fi= ?, I r I r ------ ~ ~ NO.4 MIN FOUNDATION CAK ( 12 ,. MIN LAP SPLICE ) ----------------- CONTINUOUS FOOTING & REINFORCE4ENT BAR Th~ fol1owlilg Simpson COtU1ec~ors are sufficienc for iliese ABW Panel applications: 6" fOllad~rion W"lll I 2000p3i concrete.. !leldown 5" min from end of wall. HD2A., HD5A. PHDZ & PHD5 all wi 5/3~ SSTB 16 9" foundation w311I 2000p3i concrete.. holdown min, If2~ from end of wall. STIID 10 I STHD l 0 RJ &SnID [4 I ST:>-fD [..HU 3" CQUnd:1i10n w'1ll/2000pji concrete.. heldown min. In~ from end ofW"3lI.- LJ 5 E-i? A_YD'Z2. St:-m 111 .~ "TIm 1() R r . I .... ~ . .... AL TElli'\fA TE BR~CED 'VALL PANEL (AB\VP) PER UBC SECTION 2326.11.4, lTENf 1 & 2: nvo STORY STRUCTURE DETAlL H EA D E R L.____ \_---- \ 4- \ I h 32 INCH MIN - IF LESS ~ ENGINEERING IS REQUIRED. OVER 4 FT- AB'rVP . NOT REO. ---------___L 11 - -11- - - -Ii - - -II ~ I I I I I I I } I I I I I I I } I I I I I I I I I I I I I I I I I I I I I I : I I I I I I I I I I I [ I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 2"X_ STUDS - NAIL SHEATHING TO ~ll STUDS & PLATES WI Sd :':C~J.iON OR GALV. BOX NAILS @ :3 '. OIC @ EDGES & 12" El OIC ? INTER~EDIATE SUPPORTS AND 3l0CKEO AT ALL, PL Yr'iCOO =DGES- TABLE 23-I-Q 3- VZ"X12" ANCHOR BOL TS 'HITrl 7" MIN 1M BEa.iENT AND PLACED @ PANEL ONE FIFTH RENTS 2- NO. 4 ~iNFORCEMENT BARS ,~IN GRADE 40 @ 3" MIN FRCM FC()TING BOTTCM". ( 12" MIN LAP , SPLICE ) I I I ---~~- ----------------- The following Simpson connectors are sufficient for these A8 W Panel applications: ~ 2 - 2"X _ TOP PLATES NAIL SHEATHING TO EACH PLATE WITH 3d C~N CR GALV. BOX ~ 6" ON CElli: WALL ASSENBLY MAX HEIGHT 10 FT TO TOP OF PLA TE MIN.3/S" A.P.A. RATED Pl YHOOO SHEATrlING ON BDTH SIDES OF WALL ( OUTSIDE & INSIDE ) APPROVED STEEL HOLD CC~NS IN CONCRETE C3ggg LB ~IN UPLIFT CAPACITY) INSTALLEC PER MANUFACTURED SPECS 2- Z";c PLATES (BDTTCM PLATE PRESSURE TREATED) NAIL SHEATHING TO EACH PLATE WITH 8d CC~~N OR GAlV. BDX @ 6" ON CENTER NO.4 MIN FOUNDATION BAR ( 12" MIN LAP SPLICE ) CONTINUOUS FCQTING & REINFORCEMENT BAR 8" foundation wall I 2000 Dsi concrete - holdown 5" min. from ,;:nd of wall. HD5A. PHD2, PHD5A & HTT 16 wi 5/3" SST8 16 8" foundation wall I 2000 Dsi concrete - holdown 1/2" min. From end of wall. STHD l4 & STHD 14 RJ L/- /" .~,. ~ ti \ OIX~ PIC PE","'\SlTLA CHAPTER ~)FICBO Prescriptive'Foundation ReinforcelDent ReqWrements: . *Single FamilyResidential~.;. II feet and less* . "'" 6" or 8" walls III t.l Cll - III "0 '1jj ,S; P E 0 ~ . ... !,L. N , , L___J I ' [~:__~-~i____ _________. f-f- - ------- --- ----'7 1\ /1 . 11'1 r\'1 1",'1 II' r'll !/ ~l r \: ' l\tIINIMUM FOOTING REINFORCEMENT: (2) #4 bars, typical all cases. VERTICAL WALL REINFORCEMENT: #4 bars not to exceed spacing of 18" on center. f... MINIMUM HORIZONTAL WALL REINFORCEMENT Dimensi()n "I)" Horizontal Steel' . Less than 24" 1 #4 Bar Over 24" to 36'" 2 #4 Bars1 Over 36" to 48" 3 #4 Barsl 1 Spacing not to exceed 18" on center, top bar placed not more than 7" from top of wall. FOUNDATIONS FOR STUD BEARING WALLS MINIMUM REQUlREMENTSl Number of "A" .oR" "C', . floors supported Depth to Minimum Mfuimum by foundation . bottom of footing ft)()ting !Ootin!! thickneSs width 1 12" 6" 12" 2 18" T' 15" 3 24" 8" 18" 1 Based on UBC Table 29-A Minimum concrete strength 2000 psi at 28 days. AJinimum grade 40 reinforcing steel. Lap splices shall be a minimum of 12". Anchor bolts (1/2"x10") shall be placed a maximum spacing of 48" on center. Any variation to the prescribed reinforcement must be approved by the Building Official. This. information has been provided asa guideline for minimum steel placement in residential foundations, as recommended by the Olympic Peninsula Chapter of the International Conference of Building Officials. Local jurisdictions have authority in . -.. - . the enforcement of these requirements~ Pleas~consultyour local Building Dept. .(. ,,--I -~.-... N \ OLY~ PIC PESISSI'LA CHAPTER . ~Fj('BOPrescriptive lloundatioD -. . . . . . Reinforcement Requirements: *Single Family Residential-- over 4 feet to 8 feet* . . , " ,:\.f" ,. ..,~ ~. l!, .~: ~~ :A- " L'L . S'_Q" Max. , , , , 1---.... .1._._... 1-0__....________ ___ iT------------~ " ,I " !: .MINIl\'lUM FOOTING REINFORCEMENT: (2) #4 bars, typical all cases. ~ 2"From inside face , , , , , , t::-:_i fT:"-::"~=~=- =-=."-= =--;..= ,I ': !'..L VERTICAL WALL REINFORCEMENT: #4 bars not to exceed spacing of 18" on center. fol (0 MINIMUM HORIZONTAL WALL REINFORCEMENT: 6" wall (5'0" max): (4) #4 bars, spacing not to exceed 18" on center :: 8" wall (8'0"max): #4 bars at 1 0" on center or #5 bars at 15" on center E o . ... u. N Top bar placed not more than 7" from top of wall in all cases. ~ FOUNDATIONS FOR STun BEARING WALLS MINIMUM REQUIREMENTS! . Number of , "'A" ., "'B" "C" floors supported Depth to Minimmn .' Minimum by foundation, .. bottom of footing footing , footm!! thickness Width 1 12" 6" 12" 2 18" 7" 15" 3 24" 8" 18" 1 Based on UBC Table 29-A j~linimum concrete strength 2000 psi at 28 days. Floor diaphragms and slab must be in place prior to backfill. j}linimum grade 40 reinforcing steel. Lap splices shall be a minimum of 12". Anchor bolts (l/2"x10") shall be placed a ma.,\:imum spacing of 48" on center. Any variation to the prescribed reinforcement must be approved by the Building Official. , . This information has been provided as a guideline for minimum steel placement in residentialfo~ndations~ as recommended by the OlympiC Peninsula Chapter of the international Conference of Building Officials. Local jurisdictions have authority in '. the enforcement of these requirements. ' Please consult your local Building Dept. , APPLICATION NUMBER: 00 - 0 ()~+ '5Dfvr-. fos~~ . APPLICANT: .;' II SCOPE OF WORK: 0 . NEW iE'. ADDITION 0 . REMQDEL II HEATING SYSTEM: BTU RATING: TOTAL HEATED SQ. FT. /5bt-/ . .J2J9% TOTAL GLAZING SQ. FT. ~/75 . COMPLIANCE OPTIONS OPTIONS GLAZING GLA71NG DOORS CEILING VAULTED .. WALLn INTWALL- EXT W ALL- . FLOOR. SLAB ON t "..:Ie <>Or f % FLOOR U-VAl.UE U-VALUE . CEILING " ABOVE "BEWW BELOW " GRADE ARPA" " GRADE GRADE GRADE 1. 10% 0.70 0040 R-30 R-30 R-15 R-15 R-I0 R-19 R-I0 2. 12% 0.65 0040 R-30 R-30 R-15 R-15 R-I0 R-19 R-IO ;r3.* ') 21% 0.75 0040 R-30 R-30 R-19 R-19 R-I0 R-19 R-I0 \..y 21 'Yo 0.65 0.40 R-30 R-30 R-19 R-19 R-I0 R-19 R-I0 5. 21O/~ 0.60 0.40 R-30 R-30 R-19 R-19 R-I0 R-19 R-I0 6. 25% 0.50 0040 R-38 R-30 R-19 R-19 R-I0 R-25 R-I0 '7 30% 0045 0040 R-30 R-30 R-19 R-19 R-I0 R-25 R-I0 /. 'This option requires the HV AC to have a high efficienq rating (AFUE of 0.88). Applicant must provide documentation_ 'Jf To comply with the WSEC you may choose one of the above options. Indicate which optionjs equal to or greater than the percentage obtained by dividing your glazing;'square footage by your total heated square footage. Follow the line across to determine the required insulation values of building elements for that option. A heat loss calculation mt!y: be su~itted in lieu of choosing one of these options, but will be subject to review and approval by the Building Official . WHOLE HOUSE VENTIlATION Outdoor air shall be supplied to the conditioned space at the rate of 15 cfm for each bedroom Ius 15 cfm for the remainil). livin area. Choose one 0 these 0 tions: WINDOW PORTS WALL PORTS MAKE UP AIR THROUGH FURNACE (submit HVAC contracto,.'sdesign) WINDOW SCHEDULE ON FOLLOWING PAGE MUST BE COMPLETED (a (-V l 12 r L0't'cLRe IV\. cd e )(? rl e J/"". . A^ ^ 0 o...J:J2 ." c~f!A\ h- 'J C'l \ or C 6Y\cfL f i 0 V\ f> r S lJYVvr - ~ L GlV-r \..Q ;' W.f ,~+h e ~ f"\fA.. (~r ~ ~ ?n () \.:) (3- -s p-e € 0( 0 A..~ ~ V-V\1l c:.e -~ VICINITY MAP " i fAd] (IV;! 8~1 " /9JE- (\ . -- 0 -, ~ R /7 Sl t I.oh ftF'/ k . STo-p / Ii 51 , /C:;r r~Jrfl 0/ff( . PERMIT CENTER Residential Site Plan Review Questionnaire Permit :1pplications are reviewed by our staff to make ;1 preliminary determination of the presence or absence of unique areas on the property. To help us make this determination, please supply the following information with a scaled and dimensioned site plan. I Applicant Name: -',' n i . + I _/~ ~ l\ -YO':; ""- u.::. G- I Description of Proposal: I he. ~ ~ cl,d ~ + j 0 if.. I Street Address (or cross streets if no address has been assigned): I /9/0 - c.. Oi- b.e....T \l::)r Critical Area Questions: 1. Is there any standing or running water on the surface of the site at ANY time during the year) If YES, please describe conditions: '\ /' YES X NO 2. Has any portion of the site been identitled as a \vetland? YES ~O If yes please describe: 3. Is the site characterized as: -+. Is the slope of the property: Forest t1at Cleared gentle slope 15 f1: or :more Steep (15%+) 3 ft or less -I Flat (0% to 3%) 100 ft. l The applicant hereby certities that all of the above statements and the information contained in any other transmittals made here\vith are true, and the applicant acknowledges that ,my action taken by the City of Bremerton based in whole or in part on this application may be reversed if it develops that ,my such st:1tement or other information contained herein is false. ~o I) D ~ rv~\;v'-' I" rJv~---,':> SignaMre of "-\pplicant r /d--J9-97 Date -f ~ ~ '-4 >. z <I> ~ '" !.o, f ~ " 0 .11 !.,; -.D I] -- .9 ~ ~ "" J c 1T~:'.;:.'~~"""-~ i' ~'1 r r""-'~" ~ ay ~~____ I ;,T~ ~--- el DA:r!:: !~~;o.,;;::,;:g.""..A;'.:,,;.!~l~~.J,:...~"~.'~~-::;-""::~'-M ,_..,,:.: i"~;~;~gn ~';~.-7>.""m.'?t;~~~~.-'~" rf:j'f~~ .5. ~, TrfU" d~ ~ - ,- ~_.- l~::,::2;~l~~/2. ,'T , FILE DO -~DOd 4- ,,' :'.1 '. "- ,.() ~ '-.. .\ f'r.~pe,.7't L 1J'l.f? 751 o ro...<; S ~().cky~d. WIT"\.-.. 6.. l...1<'f"'-T qt'a.d~ slof'<-. V t:' , - ..J /- 1. ~ o <.. ~ .____.--7 ._----~_._-, '. __._.,__np_~ ~. ,.---- .~'-...-.--~ r, -. 10'-::' i I ; I ~ht I ~~~ II Sf,eel. ') t f:\BIC<-k.. I l .... ~. U."ll ~ 1~5fJt!1 \;f / I I I ~ T~ CClI'c.re. f'{,\.fl~ I / / /~ ,10' ~ ] I 5,~~g~l~ : I I €f- . t-j ~ , i l~/ ~ ,/ ~ , Co..lr // I I fn-T I:;; J,. '1 . I>.J 0-'-/ \),("\ \l t. t.. \ ~ \'<v l\ ~ ~ " . 'I' -..9 ''; '-9 )- ~ '<. "'tI ~ ~- ~ o D :>. ;t ~ ..v ~ \) 'k '" "" ~l.... '0 \, \'/ ~-~; (\evJ Con S{ ruuftov\ oil) Hort\e ~. " :::,. ..l .3 'lJ => - ,. Q --,. " t J.. I - ..i ~ cr- - 11 g- c; cy . s::: -.\ I " j?:' .. '. L I~ ')' 0 ct III ~ /'Il \I .... - T ....sJ , <VI ~ J ,- v '" " 8 '\ .e .. {~~ o 0 (11'\ ,,~ ~ E--,..,s~ /9'0 c..orb.e.v'1 ()'(', fronT 0 F !+C>l.<.;,-e.. ,1>. ~., PrOfl4..t'T't LI/Il. -e ~ 1 l . . 'f~< 1;" . .**I***.~*.****.**...*****%*~*E..*W.*.**~.***'...********.z...** FtECEIP r *.~*~..I~******._*.*t***~***.~**.*..~***~*.**~.~*~*y..****_*_*** l~fCFIPr Nutilber 0000\J1.~\O i'~moHflt ~ ?J.O,QO O:J/03/00 Jl:d)6 Payment j'1ethDd~ (;1( ~ Notat ion:: fi(}SHU':~T(\ CI<Inj,t:t VW Permit NQ~ 00-0024 Type: BLDG Pnrcel N{)~ 3713600()--009"tJ307: Site Address: 1910 CORBEl DR FH,nfi Pfj;-~MIT W'/1'1€:CH/P Total fr:;i:i:~~: .1,06;;:..79 this Payment 110.00 Total ALL Pmls= 1,0&2.19 nalallt:;t-:~ .00 *.***.***~****..***....**K.********...**~*t.*..*.*****...***.SI* tlc:count (:(jdc r)ii;scriptl{))IPIl!lOllnt hr;'<3;Z~:).HJOl (2211) BUIUJINC PEF!11I'f FEC'S ~,42.1S 16-322.1005 (2215) MECHANICAL PERMIl FEES 65.75 l6-3~2.1003 (2213) PLUMBING PERMtf FEES 97.00 443,,23;"',13 (OZ36) SU11T OF juti SURCHf'lRGi::: 4.:10 :~:"'!f/ " .. ." SF- d-- OlS+- Co BUILDING PERMIT APPLICATION 286 4th Street Bremerton, WA 98337 Phone: (360) 478-5275 FAX: (360) 478-5278 APPLICANT: ~ OWNER D CONTRALI'OR D OTIIER: oo-O~4 <,ITl ^lJ[)RE~~: 19/0 - C-olrber- 'Or O\VNFR: -:S-!O kr"- ~"}~h<4 ~t-v..., T-e..t-,' r3ervt"On CONTRACTOR: 6CUne r ~ok ~ P.!)shll,(f"" ASSESSOR PARCEL #:37 fro - D 6 b.-ODQ < 036~ ADDRESS:. /C}/p- c. e>r boLT r/) r ADDRESS: UlNTRACTOR LICENSE # u )~T^CT PERSON: ~ (V\. ~s"'<(.s f(;- EXPIRATION DATE: CONTACT PHONE # ~ 7 7 - 7 c')... I ~I " ~ SFR D DUPLEX D SIGN D DEMO ~ NEW D REPAIR 18l SEWER D MULTI-FAMILY D BUSINESS D OTHER: D MOVE BLDG. D MOBILE D GRADlNG(yds): D REMODEL ~ADDITION D OTIIER: D SEPTIC INTENDED USE:rCl-ort i '7 t..., v~"'-9 NATURE OF WORK PROPOSED: A-dJ '^- 'lew 6..dJ.. l'tl~" to ,lQ. H-Ot.L.s~ cz(~1 ~~;"""'IL d h-Pk/M/J) (,-h:!rlitY~, h#o.Cl!Ja~tEcu;"'~<- cr C~~OO/1 ).?n1 m:~ .':,(.).UARE FOOTAGE: Dwelling: I ej l:. If ~t FT Garage: Decks: ./l (J F< D U Of 'or efJllrlment ,"Ie "rv VALUATION PLAN REVJEW FEE PERMIT FEE SURCHARGES TOTAL FEES J, $ 368 :u- $ ENERGY: $50.00 $ LfD (ooe) STATE: $4.50 Applications for which no permit is issued within 180 days following the date of application shall expire by limitation, and plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the building official. The building official may extcnd the limc for action by the applicant for a pcriod not exceeding 180 days on request by the applicant showing that ci:cumSlances beyond the cOlHrol of the applicant have prevented action from being taken. No application shall be extended more than once. . In order to renew action on an application after expiration, the applicant shall resubmit plans and pay a new plan review fee. / hereby certify that the above infirmation is correct to tbe best o/my knowledge. APPLICANT'S SIGNATURE:~ ?~ DATE: Id.- - <J-1O~ 9'1 hl'dl'I' Jut rcvid 1/13/97 ***.***~**..*****.******.**~.*~~**.***.*2*****.*~****~'*.~..**** RECEIPT *~~.**.**.~..****.*.*.****~.*.~~*****.*c*~**.*w**.*.**.*~.****** REtfIPl Numb~r: 00000033 Amount: 352.79 01/14/00 14=13 Pa~lm~~nt t'le~1!10d:~ CHELr: H{f"LiU10l):; POSHU:;TI~::.1.79 ndt, 'i'VR .,',.~ ."', ",. "...,.., ".. ,,~."'~ ,.... -".. .....,> """ '.... '_, ~., ~'~ ..... "'"" "".., ", ., ,,,' ... ",", ..,'..... ',,\o-...~ '~',,~..... ,... _," ~,_ ,,' '..., ~........ y" .... ~'." "-'-, _I"'u _ <.~ ""'....~ ,-,. '-'~' ".~ ,., ._, Permit Nn: 00-0024 lype: SlDG Paleel No: 378bDOe~009-0~C2 ~;jUr (-ick,1:es$;: 1~:q () CORBET Uf;;; 8LOG PERMIT W/MECHiP Tatal. ~e@!: 1.062.J9 This Pdyment ~52.79 10t01 ALL rmts: 352./9 8a12nce: 710.CO **~I#~*.*I..*.~****.***.******~.~***~%*~****~******J*.***m1t**** rtc C,(\!l) 1\ Cod(!c O(~~jj(;r ip ~ ion ,::;:!10 l.ln1 J~~<.i,\~L (:r300 \ 4~,eO) f!;UIU)U'4G PL{iN i';HH:K FEE:'; :~3S? ,/'t "Jim~W!~~37~~~~~'f?~1(~I~~}~;~~t~;T MECHANICAL PLUMBING Type of Fuel: Occupancy: Electric )( Residential i 9/0 - ~or be.) \br- Gas Commercial Oil Site Address: Ov.rner: """""' \ \ L -...) ~ ""'- 0 S 1'\..'" ') r "'- Address: I c; 10 - C Dr ~~ T f.::If'. '-:'bO' ~J7-7J..j Phone: ContLlctor: Address: Phone Contractor's License Number/Expiration Date: No. TYPE OF EQUIPMENT No. I mE OF FIXTURE I RA.i.'-JGE I I WATER CLOSET i ; WOOD/PE~~ET STOVE/GAS FIREPL\CE , I BA TIIn.:B I i . tu: I I LWATORY (bath sink) '7:;;;.- I , CO!\ivERSION BURNER btu: I I SHOWER i UNIT HEATER bru: I I KITCHEN SINK I I BOILER btu: I I i DISHWASHER I , / I GAS PIPING I I i L\CNDRY TRAY ! I 1 I EVc\POIL'\TION COOLERS btu: I 01 CL01HES WASHER. i I ~\C UNIT btu: I t WATER HEATER 1 i I J I HE1\. T PLJvfP bru: i URI:\LU- i I I 1 I REHEAT BOX bru: I DRINKING FOUNT.~'\i 1 I : , AIR H.~'JDLING UNIT bru: I I FLOOR SINK OR DILU:.'\i I I . ! I E..v-iACST FA,'-JS I SLOP SINK i i I RA."JGE HOOD (residential) WATER PIPING & c\.LTEIL\TION 1 IL\J.'\iGE HOOD (commercial) GREASE TRAP/L"JTERCEPTOR .1 CLOlliES DRYER i HOSE BIBBS : i INCINEIL\TOR , I L\ WN SPRINKLER SYSTEv[ i I I DCCT ~\LTERATION SWIM:\fING POOL I TA..'JKS type: BLDG. SEWER (mobile/moved house) i REFRIGERATION UNIT I ROOF DILAJNS I I OTHER: OTIffiR: I .0ifECI-lAL"JI CAL FEES: PLU.0ifBI~G FEES: CITY SURCI-L.-\RGE: TOT"AJ.. FEES: ~ , ~~P~[C~NT'S ~[~N"~TUR~f^~ 9~ DATE:~'- d-.tb--q OJ , '- PERMIT CENTER 286 Fourth Street Bremerton, W A 9833i' 360-478-5275 II INSPECTION REPORT II PERMIT#: OO-Obz.4 ADDRESS: ,q 10 CORBeT fl UMb1V1) (f) Vall F Tf/~'jS wel V@V7i(\~ (J) 1M flu JfII (JI n~ Ve-Nr~ (9 (J p3:>/cJe doWI/l GJ - Nol I4f/ow Cl1 -A y.rvves 111//::1- &- Vt'A/J J4l\1cA drl41al '3,~. /\PI CQy~~r Schedule a reinspection when the above items are corrected. all 360..478-5275 by 5:00 p. . for next day inspection. Date: t flJ Time: (' INSPECTOR ~ .I, " Plan Revision 3/28/00 Exiting floor f line add step up into raised elevation p (0 V I de... mtAV\lAfadlAve r S /sp.e.c 5 @ -R-tfmlv1~ .iflSfeLh'cYl t'\) e..nS' ~re (i llol.,UtJ..101 e s:paf\ 11 718" floor buss wI 14" t&g subfloor on 2x6 p.t. sill plate secure with 10" j-bolt as req. 4" concrete slab match floor ht. at jst. section gr.ade ft. 2x6 cont.bearing wall 112" ply. 1 side for shear ::::~=:'a concrete retaining wall fill and compact I pour concrete slab into wall at fll1Sh floor ht. . connect wall at ftg. wI lO"j-bolt 48" o.C. ~~~~:~~~:~~~1 l::~ ik'i\.l. 1 2DOO' :s; i . 'B 1,.@"J ~. / / \---.{".,t---=-______ / ~'~-.9 Q9Y1- REV" ION AT ~ ~ ~.~.W,fE fDJ D .. ... A PRO 5 <'OU0 REMERTON \ \ ~ BUILDING DEPARTMENT \y l q J 0 ~--{/k;(- 00 - {){);Lf Scope of work: Address: Owner: Contractor: BREMERTON BUILDING DEPARTMENT Inspection Report Permit Number:~4- Phone:_ Phone: Inspection card/approved plans on site Setbacks -- Wails required steel placement Footings: required steel placement Footlllgs. required width & depth Walls. required size ._~--- .~-- -- sp-eciaTTrlspector (when applicable) Hearing soil (soils analysis if applicable) FOUNDATION COMMENTS: FOOTINGS APPROVED: _ ._WALLS APPROVED: ~ FRAMING 4- -L.-'f - 00 Electrical approved Plumbing & mechanical approved ---- Crawl space access (min. 18 X 24) Floor joists and beams/proper clearance to earth Positive connections posts & beams Foundation vents --- Posts properly supported Anchor bolts: nuts & washers in place - Mudsill: treated material Floor joists: size & spen Beams/girders size & span Notching & drilling joists & beams, studs Smoke detectors: all required locations Exhaust fans: where required --- Exhaust fans insulated unconditioned space Whole house fan, outside air intakes each bedroom Fans terminating directly outisde Range hood .---- -- Dryer exhaust vent All vent terminations: windows & property line .-~-- ~---- ------ --.---- ._--------~------ Fireplace combustion air Windows: meets egress requirements ._-~.- ----------- Windows. proper U valve Windows: safety glazed where required ._------ -------- ------------_.~--_.- Ceiling heights Stairs: headroom clearance ---- Stairs rise & run; proper width Fireblocking: wall to ceiling, furred walls every 10' -- Fire blocking; stairs, soffits, lowered ceilings Fire blocking: tubs/showers Fire blocking: lids in void spaces, shafts Fire blocking: stuff holes top & bottom plates ------ .---- Sheetrock backing Wall bracing ---.--- ..-- Rafters size/notching Trusses: specs, bracing Attic access Attic ventilation Wall & roof sheathing Shear nailing ~--- Building dried in COMMENTS: .- rAD '()(L Co I/i .~ /yo1 Q(AfJ 'l o 1J4ei7 r'lfJ 1ft. ,<-F- BR k'l-- '"1,- JcOl R<....--- 'l;c/i>>!7 ~ jOl/J. 0 )f!P~oll~ 0 APPROVED: [ -.--- Insulation. proper R value Insulation: proper fastening ._---- .~----- ~ Insulation: vapor barrier Bottom plates caulked to floors -- --- Pen~~rat.io~s caulked as r~_qt~red Electrical boxes gasketed or caulked 6 mil black poly in crawl space ------"--.. ENERGY CODE COMPLIANCE COMMENTS: UNDER FLOOR/FOUNDATION INSULATION APPROVED: WALL INSULATION APPROVED: CEILING INSULATION APPROVED: Appliance location and access, proper support Appliance clearance to combustibles ----- Venting: size & support Venting clear ance to combustibles ------- ----- Combustion air Vent termination --.------ --------..--. ."'!._-~--~------- Ducts size & support Gas pipe under test -- Gas pipe size & support Gas pipe underground min 12" below grade -- Gas shutoff within 3' of appliance Gas pipe within 6" or underground-coated .--.-------- --------------- Gas logs: damper permanently open Gas logs safety shut-off -------- ~--- ._---~ ------------~-_.__._-------- Wood stoves EPA certified Woodstoves & fireplaces' Tight-fitting doors ~---- -- --- Manufacturer's specs on site Woodstoves & fireplaces proper hearth --- .[--- Chimney liner: when required Chimney. separate flues when required MECHANICAL ,~, ' ~l~ COMMENTS: GAS PIPING APPROVED: FURNACE APPROVED: OTHER APPLIANCES APPROVED: PLUMBING DWV & water piping under test DWV: proper grade .-- ---------------- DWV proper sizing DWV: proper drainage fittings where required DWV & water piping proper support DWV: required cleanouts --- Vent termination All fixtures vented properly --- Water supply: proper sizing Shut-off valves on all fixtures ---- r--- Water heater gate valve on cold water supply Vacuum breakers: where required -.----- ~ ----- Water heater relief valve drain to outside Water heater. siesmic strap ---. R- . -------~-----------------------------_.- -10 pad under water heater when requrred Water-piping insulated as required ---- Grease traps/interceptors where required Proper indirect wastes where required "2 t;~v-l 5/CC~ COMMENTS: lZCM4btl1j Q::>yV ~ - I ' PLUMBING GROUNDWORK APPROVED: PLUMBING ROUGH-IN APPROVED SHEETROCK ...... Proper fastening nails-?" oc. horiz. plane nails 8" oe. vertical plane -- Proper fastening' screws.12" oc horiz. plane (1/2") SCI eWs-12" o. c. horiz plane (1/2") 24" oc. framing Proper fastening serews-16" oe. vert. plane (1/2") screws-12" o.c. vert. plane (1/2") - 24" o.c. framing ------ Proper fastening screws-12" 0 c. horiz. plane (5/8") screws-12" o. c. horiz plane (5/8") - 24" O.c. framing -- Proper fastening' screvvs- 16" o.C. vert plane (5/8") screws-12" 0 c vert plane (5/8") - 24" 0 c framing ---- - Area & occupancy separation walls Draftstops where required -- I---- - Usable space under stairs (5/8" required) Water board where required (not on ceiling) -. --- Corridors COMMENTS: SHEETROCK APPROVED: FINAL Energy code requirements met, exhaust fans Plumbing & mechanical -- Garage/dwelling door self closing solid core Smoke detectors where required ------- --.. -- --- -----. Handrails & guardrails, as required Fire ratings rnaintained ------. - ..---.- .----~- Exit signs when required Emergency lighting when required - Occupant load posted when applicable Building weathertight __n ------ Wood siding to earth separation (6" Building Address posted t--. Radon monitor when required -. COMMENTS: FINAL APPROVED: