Loading...
HomeMy WebLinkAbout4851 Contract Number: 4851 Vendor: CUMMINS NORTHWEST LLC Subject: Trailer-mounted Generator for Water Utility Department: Water Resources File Class: LEG 12-1 Begin Date: 09/10/2009 � End Date: 10/10/2009 Review Date: 02/15/2011 Vault Date: O1/O1/2011 Comments : . GOODS AND SERVICES AGREEMEN' THIS AGREEMENT, is entered into between the City ofBremerton, a Washington Municipal Corporation ("City"), and Cummins Northwest, LLC ("Vendor"), whose mailing address is: 811 SW Grady Way PO Box 9811 Renton, W A 98057-3000 The parties agree as follows: 1. VENDOR SERVICES. The Vendor shall provide the following goods and materials and/or perform the following services for the City: A 150-kW trailer-mounted portable generator as specified in the attached specification. 2. TIME OF COMPLETION. Vendor shall complete the work and provide all goods, materials and services within 30 calendar days from the date all parties have signed this Agreement. 3. COMPENSATION. The City shall pay the Vendor the total amount of$ 65,469.51, including applicable Washington State Sales Tax, for the goods, materials and services contemplated in this Agreement. The City shall pay the Vendor the following amounts according to the following schedule: Payment Term Net 30 days following invoice. Retention not to exceed 5% of the contract total may be withheld; retention shall be due and payable within 30 days from initial power start. A. Defective or Unauthorized Work. The City reserves its right to withhold payment from Vendor for any defective or unauthorized goods, materials or services. If Vendor is unable, for any reason, to complete any part of this Agreement, the City may obtain the goods, materials or services by Agreement or otherwise, and Vendor shall be liable to the City for any additional costs incurred by the City. "Additional costs" shall mean all reasonable costs, including legal costs and attorney fees, incurred by the City beyond the maximum Agreement price specified above. The City further reserves its right to deduct the cost to complete this Agreement, including any Additional Costs, from any and all amounts due or to become due the Vendor. 4. INDEPENDENT CONTRACTOR. Contractor is and shall be at all times acting as an independent contractor and not as an employee of the City. The Contractor shall secure at its expense, and shall be responsible for all payments of income tax, social security, state disability insurance compensation, unemployment compensation, and all other payroll deductions for the Contractor, officer, agents, employees and sub-contractors. The Contractor shall also secure all applicable business licenses, if required, in connection with the contract services, including all required licenses for Contractor's officers, agents, employees and sub-contractors. 5. TERMINATION. The City may temlinate this Agreement for good cause. "Good cause" shall include, without limitation, any one or more of the following events: A. The Vendor's refusal or failure to supply a sufficient number of properly skilled workers or proper materials for completion of this Agreement. Goods and Services Agreement 3-09 Cummins Northwest, Inc. Trailer-mounted Generator Page 1 B. C. D. E. The Vendor's failure.omPlete this Agreement within the time speciln this Agreement. The Vendor's failure to make full and prompt payment to subcontractors or for material or labor. The Vendor's failure to complete with federal, state or local laws, rules or regulations. The Vendor's filing for bankruptcy or becoming adjudged bankrupt. If the City terminates this Agreement for good cause, the Vendor shall not receive any further monies due under this Agreement until the goods, materials and services required by this Agreement are completed and fully performed. 6. CHANGES. The City may issue a written change order for any change in the goods, materials or services to be provided during the performance of this Agreement. If the Vendor determines, for any reason, that a change order is necessary, Vendor must submit a written change order request to an authorized agent of the City within fourteen (14) calendar days of the date Vendor knew or should have known of the facts and events giving rise to the requested change. If the City determines that the change increases or decreases the Vendor's costs or time for performance, the City will make an equitable adjustment. The City will attempt, in good faith, to reach agreement with the Vendor on all equitable adjustments. However, if the parties are unable to agree, the City will determine the equitable adjustment as it deems appropriate. The Vendor shall proceed with the change order work upon receiving either a written change order from the City or an oral order from the City before actually receiving the written change order. If the Vendor fails to require a change order within the time allowed, the Vendor waives its right to make any claim or submit subsequent change order requests for that portion of the contract work. If the Vendor disagrees with the equitable adjustment the Vendor must complete the change order work; however, the Vendor may elect to protest the adjustment as provided below: A. Procedure and Protest bv the Vendor. If the Vendor disagrees with anything required by a change order, another written order, or an oral order from the City, including any direction, instruction, interpretation, or determination by the City, the Vendor shall: 1. Immediately give a signed written notice of protest to the City; 2. Supplement the written protest within fourteen (14) calendar days with a written statement that provides the following information: a. The date of the Vendor's protest. b. The nature and circumstances that caused the protest. c. The provisions in this Agreement that support the protest. d. The estimated dollar cost, if any, of the protested work and how that estimate was determined. e. An analysis of the progress schedule showing the schedule change or disruption if the Vendor is asserting a schedule change or disruption. 3. The Vendor shall keep complete records of extra costs and time incurred as a result of the protested work. The City shall have access to any of the Vendor's records needed for evaluating the protest. The City will evaluate all protests, provided the procedures in this section are followed. If the City determines that a protest is valid, the City will adjust payment for work or time by an equitable adjustment. No adjustment will be made for an invalid protest. B. Vendor's Duty to Complete Protested Work. In spite of any protest, the Vendor shall proceed promptly to provide the goods, materials and services required by the City under this Agreement. Goods and Services Agreement 3-09 Cummins Northwest, Inc. Trailer-mounted Generator Page 2 . e C. Vendor's Acceotance of Changes. The Vendor accepts all requirements of a change order by: (1) endorsing it, (2) writing a separate acceptance, or (3) not protesting in the way this section provides. A change order that is accepted by Vendor as provided in this section shall constitute full payment and final settlement of all claims for contract time and for direct, indirect and consequential costs, including costs of delays related to any work, either covered or affected by the change. D. Failure to Protest Constitutes Waiver. By not protesting as this section provides, the Vendor also waives any additional entitlement and accepts from the City any written or oral order (including directions, instructions, interpretations, and determination). E. Failure to Follow Procedures Constitutes Waiver. By failing to follow the procedures of this section, the Vendor completely waives any claims for protested work and accepts from the City any written or oral order (including directions, instructions, interpretations, and determination). 7. CLAIMS. The Vendor shall give written notice to the City of all claims other than change orders within fourteen (14) calendar days of the occurrence of the events giving rise to the claims. Any claim for damages, additional payment for any reason, or extension of time, whether under this Agreement or otherwise, shall be conclusively deemed to have been waived by the Vendor unless a timely written claim is made in strict accordance with the applicable provisions of this Agreement; or, if (and only if) no such provision is applicable, unless that claim is set forth in detail in writing and received by the City within seven (7) calendar days from the date Vendor knew, or should have known, of the facts giving rise to the claim. At a minimum, a Vendor's written claim must include the information set forth regarding protests in Section 7(A)(2)(a)-(e). FAILURE TO PROVIDE A COMPLETE, WRITTEN NOTIFICATION OF CLAIM WITHIN THE TIME ALLOWED SHALL BE AN ABSOLUTE WAIVER OF ANY CLAIMS ARISING IN ANY WAY FROM THE FACTS OR EVENTS SURROUNDING THAT CLAIM OR CAUSED BY THAT DELAY. Vendor must, in any event, file any claim or bring any suit arising from or connected with this Agreement within 120 calendar days from the date the contract work is complete. 8. WARRANTY. Manufacturer's warranty applies. Cummins northwest makes no representation or warranty as to the fitness of the equipment for any particular use or purpose, as to the condition, quality or merchantability of the equipment, or any other representation or warranty, express or implied, and makes no warranties of any kind, express or implied, except that the equipment shall be free from defects in workmanship and material under normal use and service and except as provided in warranty materials delivered to the customer, the receipt of which customer acknowledges by accepting delivery of the equipment. The sole responsibility of Cummins northwest under this sales order is to repair or replace the equipment, in the manner described in such warranty materials, and it shall not be liable under any express or implied warranty or noncontractual theory ofliability for any special, indirect or consequential damages, including loss of time, inconvenience, loss of use of the equipment, liability for personal injury or property damage, in any way arising out of customer's purchase of the equipment, or commercial losses. Goods and Services Agreement 3-09 Cummins Northwest, Inc. Trailer-mounted Generator Page 3 . e 9. INDEMNIFICATION. Vendor shall defend, indemnify and hold the City, its officer, officials, employees, agents and volunteers harmless from any and all claims, injuries, damages, losses or suits, including all legal costs and attorney fees, arising out of or in connection with the performance of this Agreement. Vendor's obligation to indemnify shall not extend to that portion of damages caused by the City's sole negligence. The City's inspection or acceptance of any of V endor's work when completed shall not be grounds to avoid any of these covenants of indemnification. Should a court of competent jurisdiction determine that this Agreement is subject to RCW 4.24.115, then, in the event ofliability for damages arising out of bodily injury to persons or damages to property caused by or resulting from the concurrent negligence of the Vendor and the City, its officers, officials, employees, agents and volunteers, the Vendor's liability hereunder shall be only to the extent of the Vendor's negligence. IT IS FURTHER SPECIFICALLY AND EXPRESSLY UNDERSTOOD THAT THIS INDEMNIFICATION CONSTITUTES THE CONSULTANT'S WAIVER OF IMMUNITY UNDER INDUSTRIAL INSURANCE, TITLE 51 RCW, SOLELY FOR THE PURPOSES OF THIS INDEMNIFICATION. THE PARTIES ACKNOWLEDGE THAT THEY HAVE MUTUALLY NEGOTIATED THIS WAIVER. The provisions of this section shall survive the expiration or termination of this Agreement. 10. INSURAN CEo The Vendor shall procure and maintain for the duration of this Agreement, insurance against claims for injuries to persons or damage to property that may arise from or in connection with the performance of the Contract work by the Vendor, its agents, representatives, employees or subcontractors. Before beginning work on the project described in this Agreement, the Vendor shall provide a Certificate ofInsurance evidencing: 1. Automobile Liabilitv insurance with limits no less than $1,000,000 combined single limit per accident for bodily injury and property damage; and 2. Commercial General Liabilitv insurance written on an occurrence basis with limits no less than $1,000,000 combined single limit per occurrence and $2,000,000 aggregate for personal injury, bodily injury and property damage. Coverage shall include but not be limited to: blanket contractual; products/completed operationslbroad form property damage; and employer's liability. Any payment of deductible or self insured retention shall be the sole responsibility of the Vendor. All required policies shall be provided on an "occurrence" basis except professional liability insurance (if required), which shall be provided on a "claims-made" basis. The City shall be named as an additional insured on the Commercial General Liability insurance policy, as respects work performed by or on behalf of the Vendor and a copy of the endorsement naming the City as additional insured shall be attached to Goods and Services Agreement 3-09 Cummins Northwest, Inc. Trailer-mounted Generator Page 4 the Certificate of Insurance. .City reserves the right to receive a certified C!f all the required insurance policies. The Vendor's Commercial General Liability insurance shall contain a clause stating that coverage shall apply separately to each insured against whom claim is made or suit is brought, except with respects to the limits of the insurer's liability. The Vendor's insurance shall be primary insurance as respects the City and the City shall be given thirty (30) days prior written notice by certified mail, return receipt requested, of any cancellation, suspension or material change in coverage. The City also reserves its unqualified right to require at any time and for any reason, proof of coverage in the form of a duplicate of the insurance policy with all endorsements as evidence of coverage. 11. MISCELLANEOUS. A. Licenses and Taxes. Vendor shall possess a current Bremerton Business License and any regulatory license required to fulfill Vendor's obligations under this contract. B&O taxes shall be paid when due, and Vendor, by this agreement, assigns any payments due under this contract to the City Clerk for payment of such taxes which have been declared delinquent. B. Conflict and Precedence. In the event of a conflict between the contract documents, the document which rates higher on the following list shall take precedence: 1. Addenda, if any, 2. Contract, 3. Specifications, 4. Terms and Conditions, 5. Contractor's proposal. C. Documents Incorporated bv Reference. The following documents are incorporated by reference, to include, but not be limited to: 1. Terms and Conditions, 2. Specifications, 3. Proposal, and 4. Non-Collusion Affidavit. D. Nondiscrimination. In the hiring of employees for the performance of work under this Agreement the Vendor, its subcontractors, or any person acting on behalf of Vendor shall not, by reason of race, religion, color, sex, sexual orientation, national origin, or the presence of any sensory, mental, or physical disability, discriminate against any person who is qualified and available to perform the work to which the employment relates. E. Compliance with Laws. Vendor shall comply with all federal, state and local laws, rules and regulations throughout every aspect in the performance of this Agreement. F. Work Performed at Vendor's Risk. Vendor shall take all precautions necessary and shall be responsible for the safety of its employees, agents, and subcontractors in the performance of this Agreement. All work shall be done at Vendor's own Goods and Services Agreement 3-09 Cummins Northwest, Inc. Trailer-mounted Generator Page 5 risk, and Vendor sha.responsible for any loss of or damage to materi!ools, or other articles used or held for use in connection with the work. G. Governing Law. This Agreement shall be governed and construed in accordance with the laws of the State of Washington. If any dispute arises between the City and Vendor under any of the provisions of this Agreement, resolution of that dispute shall be available exclusively under the jurisdiction, venue and rules of the Kitsap County Superior Court, Kitsap County, Washington. H. Attornev's Fees. In any claim or lawsuit for damages arising from the parties' performance of this Agreement, each party shall be responsible for payment of its own legal costs and attorney's fees incurred in defending or bringing such claim or lawsuit; however, nothing in this subsection shall limit the City's right to indemnification under Section 9 of this Agreement. I. Written Notice. All communications regarding this Agreement shall be sent to the parties at the addresses listed below, unless otherwise notified. Any written notice shall become effective upon delivery, but in any event three (3) calendar days after the date of mailing by registered or certified mail, and shall be deemed sufficiently given if sent to the addressee at the address stated in this Agreement. Notices to be sent to: Notices to be sent to: VENDOR: CITY: Attn: Richard Dickson Cummins Northwest, LLC PO Box 9811 Renton, W A 98507-3000 Attn: Kathleen Cahall City of Bremerton 3027 Olympus Drive Bremerton, W A 98310 J. Assignment. Any assignment of this Agreement by the Vendor without the written consent of the City shall be void. K. Modification. No waiver, alteration, or modification of any of the provisions of this Agreement shall be binding unless in writing and signed by a duly authorized representative of the City and Vendor. L. Severabilitv. If anyone or more sections, sub-sections, or sentences of this Agreement are held to be unconstitutional or invalid, that decision shall not affect the validity of the remaining portion of this Agreement and the remainder shall remain in full force and effect. M. Entire Agreement. The written provisions and terms of this Agreement, together with any attached Exhibits, supersede all prior verbal statements by any representative of the City, and those statements shall not be construed as forming a part of or altering in any manner this Agreement. This Agreement and any attached Exhibits contain the entire Agreement between the parties. Should any language in any Exhibit to this Agreement conflict with any language contained in this Agreement, the terms of this Agreement shall prevail. IN WITNESS WHEREOF, the parties below have executed this Agreement. Goods and Services Agreement 3-09 Cummins Northwest, Inc. Trailer-mounted Generator Page 6 . . VENDOR: CITY: ~~ \....... 5 ~c~..........~\ \.U. , BY~~~ Print Name: '"'2 \'\"-( \^-l \.L-Sc:::Y\J Its: \.l \ ~. ,?c::>............,Q.v- (:::r- r"'<"'~d~ Date: '\. -,--~~ City of Bremerton B~~~~ Print Name: C e..c l /..... ("1 (> COP,{) eLL Its: Date: 0/1 % 9- APPROVED AS TO FORM: BY~i~~~ ATTEST: ~ By:(',A1A.I'~ )~~.A.1 ' ~)O!f.tfity Clerk Goods and Services Agreement 3-09 Cummins Northwest, Inc. Trailer-mounted Generator Page 7 RX DatelTime 02/18/2009 10:45 FEB-IT-ZOOS IO:33PM FROM-Cu~mlns Ncrt~wast +425 235 8202 +~25-Z35-8Z02 P.OOl r-082 POOl Hao . , (j) Cummins Northwest, Inc. 811 SW Grady Way (98055) PO Box 9811 Renton, WA 98057-3000 (425) 235-3400 Fax: (425) 235-8202 c. Power System Quotation Date: February 17, 2009 To: Kathleen Cahall # Pages: 31 Fax Number: 360-473-5398 Company: City of Bremerton Phone Number: 360-473-5270 From: Richard Dickson Title: Power Generation Sales Direct line: 425-277-5340 Email: richard.dickson@cummins.net Project Name: 150 kW Generator Quotation Kathleen Attached js Cummins Northwest quotation to supply a 150 kW trailer - mounted Portable Generator. Thank you for the opportunity to provide this quotation. Richard Dickson Direct 425 277-5340 Cell: 206794-9801 EmaiJ: richard.dickson@cummins.com PowerfUl Solollons - Dependable SUDDon - 1VlftY nMt www.cumminsnorthwest.com Thb tr.lI1S[Ili)~iQn is iIllcndttl for the ~ole \1$<: of the il1dividu:lI:w1 entity 10 wbolO It is i1ddrcs~ed. ilIld lIlay COl1tllin infgrmation that is privilCSed. cOflfjdc:oLial ;llId CAomJpl !TolD (!iscloslU1: under applil::Ible law. You ~ bl.>t'Cby noufied dmt illl)' di~semiutlrlon. dislribulfon ur duplic,tiun of thi~ transmission by someone olher rh,n the inlcnclt!.d adorcss,,~ or 1(.0; c1:si~au:d agent is ,aicd)' pr.llubitc:d. lr your nx:cipl (lr this Ir:U'snlission is in error, pk:!!1c notify lhis rum illlm::rualely by collel:t c:lll and send rh~ crigirull tra1\5missioQ to Uo' by rerum mnil al i.he llbo,"" .ddl'C'S" C Power - . Generation anon m. 120104-1 RX DateJTime 02/18/2009 10:45 FEB-17-2009 IO:33PM FRO~-Cum~ins North~est +425 235 8202 +4Z5-m-8Z0Z P.002 T-08Z P.OOl F-SSO (2;J '1 ' . . '.: '. . .' : ". ..' '..,. ;..~., ~ . "C' -'. .. ......' " . . ,. . ." . - Power .:. ..... ..'. ". .: ',. .:: '.: . Generation ;'ourenergywOrf<ingfor'you.". .... .. ..... >;.::......... "'" ,. .,... . Quotation Cummins Northwest, LLC 811 SW Grady Way Renton W A 98057 United states February 18, 2009 Project Name: City of Bremerton 150kW Trailer Mounted Gensel auotation: 167300000D029031 Thank you for your Inquiry. We are pleased to quote as follows; . Item USD - Description Diesel Genset: 60Hz-150kW InstaJl-US-Nonroad Installation-In USA,Nonroad 150DSGAC A331-2 L09D-2 L 119-2 F173-2 R002-2 6268-2 H702-2 8184-2 A366-2 H536-2 H609-2 A362-2 H606-2 KAOS-2 K631-2 A292.2 KP81-2 KU11.2 KT86-2 F206-2 F1 79-2 C127-2 Genset-Diesel,60Hz, , 50kW Duty Rating-Standby Power L1sting-UL 2200 Cert-EPA.Nonroad Cl,Tier 3 per 40 CFR 89 Enclosur&-Steel,Sound AU,level 2,w/Exhaust System Voltage-2n /480,3 Phase, Wye,4 Wire Altemator-60Hz,12 Ld, Broad Rng,Full1 Ph Outp, 1 05C GENSET CONTROL-POWERCOMMAND 2.2 Exciter/RegulatorAPmg, 3 Phase Sensor Engine Governor-Electronic, Isochronous Only Display language-English Control Mounting-Left Facing Heater-Control Cabinet, 120V AC Meters-AC Output,Analog Alarm-Audible, Engine Shutdown Relays-Genset Status, User Configured Heater-Alternator, 120 Volt AC Circuit Breaker Or Entrance Box-Right & Left Side CirBrkr-500A, Left,3P ,600/690V, SS RMS,80%, ULlIEC CircuitBreakerA250A, Aight,3P ,240V ,TM,80%U L Wind Aaling-150 MPH,Steel Housing Skidbase-Housing Ready Sl!:parator-Fuel/Wat~r 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 R)( DateJTime 02/18/2009 10:45 FEB-iT-200B IO:34PM FROM-Cummins ~orthwest +425 235 8202 +4 Z 5- 235 -8 2 0 Z T-08Z P 003 F-680 (g A422-2 A333-2 1;125-2 H389-2 E089-2 H036-2 0038-2 L028-2 L031-2 A322-2 F06S-2 F180-2 H268-2 CP01-2 SPEC-B 3rd Breaker LOW FUEL ALARM ISOLATORS Battery Charger Trailer Posi Lock Freight Engine Starter - 12 vaG Motor Battery Charging Alternator-Normal Output Engine Cooling-High Ambient Air Temperatura Shutdown-Low Coolant Level Extension-Engine Coolant Drain Coolant Heatar-120 Volt Ac, Single Phase Engine Air Cleaner-Heavy Duty Test ReCOrd-Certified Genset Warranty-5 Year Comprehensive Packing-Skid, Poly Bag Rack-Battery Window-Enclosure,Control Viewing Extension-Oil Drain Common Parts Listing Product Revision - B Circuit Breaker 250 Amp, 3 pole wI shunt trip. 600 VAC, wired to 120/208 VAC Low Fuel alarm in daytank - 35%, annunciated at control pane'- Kortund pad type isolators Sens 10 am p NFP A 110 battery charger with float. Tandem axle, 10,000 GVWR trailer with Integral single wall 200 gallon fuel tank, stabilizer jacks (4), tongue jack, electric brakes. breakaway safety switch, toolbox, adjustable receiver height. Spare tIre and rim. Crouse Hinds E0200 Male PosHock Distribution Panel Wired to 200 Amp BreaKer. Incoming Trailer Freight Voltage Selector 3 position voltage selector switch. 120/208V & 277/480V 3 phase and 120!240V 1 ptlase Hubbels Hubbel receptacles lor coolant heater, charger, auto start signal. 20 A circuit breaker box. P.003 1 1 1 1 , 1 1 1 1 1 1 1 1 1 1 1 1 4 1 1 1 RX DatelTime 02/16/2009 10:45 FEB-iT-Z009 10:34PY FROM-Cum~ins Northwest +425 235 8202 +425-235-8202 P.004 T-082 P 004 F-680 L.::!J Battery HD Starting battery. Lead acid. 1 LITERATURE O&M Manuals in CNW Binder 3 Upfit Up-fit Labor to install Post-lock Panel, charger, 3rd breaker, 3-position selector switch, HUbbell connector. MOunt Generator 1 TRAINING One on-site training session 4 hours for up to 10 persons. 1 Delivery Delivery to jobsite. 1 STARTUP On-site startup and 2 liOur loadbank test. 1 Commercial Accessories Commercial Accessories Grand Total $60,825.00 OPTIONAL DEDUCT Startup, 2 hour loadbank test, acceptance testing, and training al CNW Renton in Lieu of on-site_ Same day. -$1500.00 NOTES: 1. THIS QUOTATION IS SUBJECT TO CUMMINS NORTHWES-r, LLC STANDARD TERMS & CONDITIONS - SEE ATTACHMENT 2. A ONE YEAR MAINTENANCE AGREEMENT IS NOT INCLUDED IN THIS QUOTATION, AVAILABLE FOR AN ADDITIONAL PRICE. 3. REGARDING SELECTIVE COORDINATION FOR NEC ARTICLE 700 AND 701 LOADS. CUMMINS GENERATORS ARE EQUIPPED WITH THE MANUFACTURERS RECOMMENDED THERMAL MAGNETIC CIRCUIT BREAKER. INFORMATION REGARDING THIS DEVICE CAN BE SUPPLIED UPON REQUEST. THIS QUOTATION IS NOT VALID IF ANY CHANGES TO THIS CIRCUIT BAEAKER(S) IS REQUIRED TO COORDINATE WITH OTHER DEVICES IN THE ELECTRICAL DISTRIBUTION SYSTEM. IF g.~ <JO Seclti- ~ tw{ ~. 5,;;J, 30, '1~ RX DatelTime 02/18/2009 10:45 FEB-IT-20DS 10:3~PM FROM-Cummins NorthwBst +4252358202 +425-m-820Z CHANGES ARE REQUIRED. THE CUSTOMER MUST PROVIDE A COpy OF THE COORDINATION STUDY LISTING THE MANUFACTURERS MODEVPAAT NUMBER OF THE DISCONNECT DEVICE TO BE SUPPLIED WITH THE GENERATOR AND A REVISED QUaT ATION WILL BE ISSUED. Submitted by ichard Dickson, Industrial Generator Sales rlchard.dickson@cummins.com Direct: 425-2n-5340 Mobile: 206-794-9801 Fax: 425-235-8202 T-OS2 PODS P.005 HSO \..:V RX DatelTime 02/18/2009 10:45 FEB-17-Z009 10:34P~ FROM-Cummins Northwest +4252358202 +425-235-9202 P.006 T-092 P 00S/031 F-S80 ........ Cummins Northwest, LlC Attachment to Quotation -Exclusions- Fuel System: All fuel for testing and initial fill. Electrical: Field terminations of wiring. and lugs other lhan those detailed in our submittal. Miscellaneous: Third PartY electricallesling and certification. seismic calculations, coordination studies, stampod engineering calculations. emissions testing, all other services and material not specIfically listed in the precedIng quotation. Documentation: Unless stated otherwise, three selS of 0 & M manuals are available upon request. Electronic documentation may be available at an additional cost Taxes and Permits: Any applicable sales tax, permits. licenses. All items listed are excluded and will OI1~ be supolied bv Cummins Northwest. LLC If aareed UDon. in writina. bv a sales representative for Cummins Northwest. LLC. Current facfory lead time is 12-14 weeks after drawing approvals. -Terms and Conditions- . This offer and quotation incorporates and is contingent upon acceptance of 1he terms and conditions in the standard Sales Order of Cummins Northwest, LLC. Purchase Orders or other documents with terms and conditions that are inconsistent with the CNW standard Sales Order will not be accepted unless agreed to in writing by an officer of Cummins Northwest. LLC. . Prices are valid far 30 days . If Included In the quotation, all on-site startup, testing and training assumes weekdays. during standard CNW business hours. Additional charaes mav be added far work requested to be done on overtime. weekends. and holldavs. . F.O.B. factorY. freiaht allowed to icbsite. off-loadlnQ is not included . Factory direct shipments require credit approval prior to shipment . Terms are C.O.D. or net 30 days uDon a""roval of credit . Equipment held for longer than 30 days rnay be charged a monthly storage fee . Cancellation charges are 25% minimum alter release of order CLARIF'ICA nONS AND COMMENTS Gensel quoted is Cummins current 150 kW Generator with a Model QSB1. 7 litre ( 408 cu. in.) in-line 6 cylinder 4 cycle engine. This rephu:es the previous 9 liter (543 cu. in.) engine for this kilowatt range. 120204 rev. 2107 RX Date/Time 02/18/2009 10:45 FEB-17-2009 10:34PM FROM-Cummins NorthwBst +425 235 8202 +m-235-8202 P.007 T-OB2 P 007/031 F-6BO (j; I ;Ii '.1; .,. 'I; i'l ':'1 " ., ,. _... - ____, I' .' .:,.:'::..;.~'~./ ~.":?~',",il .......:..~.....,. CITY OF BREMERTON PUBLIC WORKS AND UTILITIES DEPARTMENT WATER RESOURCES DIVISION EQUIPMENT SPECIFICATIONS: PORTABLE, DIESEL, TRAILER-MOUNTED GENERATOR Bidders may list variations to these minimum specifications in the "COMMENTS" section of the Bid sheets. Bidders may also suggest alternatives to specified name brand products specified by the aty of 8remerton in the "COMMENTS" section as an "Approved Equal'. To be considered as an "Approved Equar, the specifications of the suggested alternative JJ.'!l!S be attached for our review. Bidders are also encouraged to list and price any options which are felt to enhance the use of item bid and/or would be desirable. All standard equipment is to be induded, specified or not. VENDOR Cu/1,M 'rJ S 1\1 b (( TI-J w ~ s -r I. L L G # PART 1 - GENERAL REQUIRED CRITERIA MEETS 1.01 . Scope SPEC? COMMENTS YES NO A. Provide complete factory assembled generator set equipment with digital (microprocessor-based) electronic generator set controls, digital governor. and digital voltage 'i. regulator. Generator to be installed on a tandem axle transportable trailer for a complete operating system; including. but not limited to, the items as specined hereinafter. a Provide factory test, startup by a supplier authorized by Y.. the equipment manufacturer(s), and on-site testing of the system. C. The generator set manufacturer shall warrant all 'i equipment provided under this section, whether or not it Is manufactured by the generator set manufacturer, so there Is one source for warranty and product service. Technicians specifically trained and certified by the manufacturer to support the product and employed by the generator set supplier shall service the generator set. Page 1 of 25 RX DatelTime FEB-17-2Q09 10:34PM 02/18/2009 FROM-Cummins Northwest 10:45 +425 235 8202 +425-235-B202 T-0B2 P 00B/031 (!;) P,OOB HBO D. The manufacturer shall provide product literature. V perfolTTlance data, and engineered shop drawings of the ^ generator set and trailer at the time of bid submittal. MEETS 1.02 - Codes and Standards SPEC? COMMENTS YES NO A. The generator set and its installation and on-site testing ~ shall conform to the requirements of the following codes and standards: 1. C5A C22.2, No. 14 - M91 Industrial Control X Equipment 2. C5A 282, 1969 Emergency Electrical Power Supply 'X. for Buildings 3. EN50082-2, Electromagnetic Compatibility - Generic Y- Immunity Requirements, Part 2: Industrial. 4. EN55011, Limits and Methods of Measurement of ::X. Radio Interference Characteristics of Industrial, Scientific and Medical Equipment. 5. FCC Part 15. Subpart B. X 6. IEC8528 part 4. Control Systems for Generator Sets 'A. 7. lEe Std 801.2, 801.3, and 801.5 for susceptibility, ~ conducted, and radIated electromagnetic emissions. 8. IEEE446 - Recommended Practice for Emergency X. and Standby Power 5ystems for Commercial and Industrial Applications Page 2 of 25 RX Date/Time 02/18/2009 10:45 FEB-iT-200e IC:34PM FROM-CUffi]lnS Northwest +425 2358202 +425-235-8202 P.009 T-CB2 P 009/031 F-6BO @ 9. IEEE587 for voltage surge resistance. '^- 10. Mil std 4610 -1993. Military Standard. X Electromagnetic Interference Characteristics. 11. Mil std 4620 - 1993. Military standard. '^- Measurement of Electromagnetic Interference Characteristics. 12. NEMA ICS10-1993 - AC Generator sets. X 13. NFPA70 - National Electlical Code. Equipment shall be suitable for use in systems in compliance to X Articles 700. 701, and 702. 14. NFPA99 - Essential Electrical Systems for Health X Care Facilities 15. NFPA 110 - Emergency and Standby Power Systems. Tile gener..stor set shall meet all X requirements for level 1 systems. Level 1 prototype tests required by this standard shall have been performed on a complete and fundional unit. Component level type tests will not substitute for this requirement. 16. UL508. The entire control system of rhe generator )( scrt shall be UL508 listed and labeled. 17. UL2200. The generator set shall be listed to Ul2200 X or submit to an independent third party certification process to verify compliance as installed. B. The generator set manufacturer shall be certified to ISO X 9001 International Quality Standard and shall have third party certification verifying quality assurance in design/development, production, installation, and service. in accordance with ISO 9001. Page 3 of 25 RX DatelTime 02/18/2009 10:45 FEB-li-2009 iO:34P~ FROM-Cum~ins Northwest +425 235 8202 +42H3H202 P.Ol0 T-082 P.O:O/031 F-680 ~ I Acceptable Manufacturers ' C. 1. This system shall be supplied by an approved, national supplier who has been regularly engaged In i the production of engine-driven alternator sets, automatic transfer switches, and associated controls for a minimum of ten years, providing one source of supply and responsibility. 2. To be classified as a manufacturer, the builder of the generator set must manufacture at least the engine X or alternator. 3. The manufacturer shall have printed literature and brochures describing the standam series specified, '/.. not a one-of-a-kind fabrication or package. Page 4 of 25 RX DatelTlme 02/18/2009 '10:45 FEB-17-2009 10:35PM FROM-C~m~ins Ncrthw9st +4252358202 +m-235-B202 P.Oll T-082 P,Ol1/031 F-680 (0 PART 2 - PRODUCTS 2.01 - OTHER EQUIPMENT TO BE MEETS COMMi:NTS SPEC? PROVIDED YES NO A. Trailer 1. Capable of transporting the unit at highway speeds. '/.-- Traner to be rated at the appropriate GVW to carry the genset, full fuel tank, and 1,500 pounds of accessories. Total trailer length not to exceed 18 feet. 2. Trailer consists of: dual axle assembly designed for low center of gravity consisting of steel bed, and X. radial tires Including spare. 3. Trailer chassis: welded steel channel construction with minimum 200 gallon integral ruel tank.. Provide: a. 6-inch adjustable height 25/16" ball hitch b. Electrfc brakes WIth breakaway system for both axles c. Safety chains with hooks X d. GVW rated four stabilizer jacks with feet e. Heavy duty tongue jack f. Steel fenders g. Ucense plate bracket h. 12 volt Ice 7 wire round trailer plug L Brake, turn, tall. and license plate lights j. Finish: 2 coats etching primer, 2 coats incjustriaJ enamel. Trailer is to be painted black or to match manufacture"s standard color. 4. Trailer shall comply with applicable State of 'J... WaShington Code and Federal Motor Vehicle Safety Standards (49 CFR Part 571). Page 5 of 25 RX DatelTime FEB-17-2009 10:35PM 02/18'2009 10:45 FROM-Cummins Northwest +425 235 8202 +425-235-9202 T-092 P 012/031 UJ;;I P.012 F-690 B. Outdoor, Weather.Protective, Sound Attenuating Housing 1. The generator set shall be provided with a sound- attenuated housing which allows the generator set to operate at futl rated load In the ambient conditions specified. The enclosure shall reduce the sound level of the generator set while opemting at full rated 'i load to a maximum of 17.5 dBA at any location 7 meters from the generator set in a free field environment. Housing configuration and matenals used may be of any suitable design which meets application needs, except that acoustical materials used shall be 011 and water resistant. No foam materials shall be used unless they can be demonstrated to have the same durability and life as fiberglass. 2. The enclosure shall indude hinged doolS for access to both sides of the engine~ and altemator, and the "h control equipment. Key-locking door latches shall be provided for all doors. Door hinges shall be stainless steel. 3. The enclosure shall be provided with an exhaust silencer which is mounted inside of the enclosure, "'/... and allows the generator set package to meet speClfled sound level requirements. Silencer and . exhaust shall include a rain cap and rain shield. 4. All sheet metal shall be primed for cOlTQslon protection and finish painted with the manufadurer's )( standard color. All surfaces of all metal parts shall be primed and painted. 5. Painting of hoses, clamps, wiring harnesses, and other non-metallic se"'ice parts shall not be '/.. acceptable. Fasteners used shall be corrosion resistant, and designed to minimize marr1ng of the painted surface when removed for normal instaUation or service work. Page 6 of 25 RX DatelTime FEB-IT-200S IO:35PM 02/18/2009 10:45 FROM-Cu~mins Northwest +4252358202 +425-235-B202 T-OB2 P.OI3/031 @ P.013 HBO MEETS 2.02 .. Generator Set SPEC? COMMENTS yes NO A. Ratings 1. The generator set shall operate at 1800 rpm and at a X. voltage of: 277/480 Volts AC. three phase, four-wire, 60 hertz. 2. The generator set shall be rated at 150 kW. 188 kVA at 0.8 PF, based on site conditions at allltude 1,000 .x ft. (330 meters), ambient temperatures up to 104 degrees F (40 degrees C). 3. The generator set rating shall be based on standby X. service. S.Performance 1. Voltage regulation shall be plus or minus 2 percent K. for any constant load between no load and rated load. Random voltage variation with any steady load from no load to full load shall not exceed plus or minus 2 percent. 2. Frequency regulation shall be isochronous from steady state no load to steady state rated load. "^- Random frequency variation with any steady load from no load to full load shall not exceed plU5 or minus 0.25%. 3. The diesel engine-generator set shall pick up a single step load of 100% nameplate kW and power factor. ~ less applicable derating factoJ'S, with the engine- generator set at operating temperatura. 4. MOlor stanlng capability shall be a minimum 01 no kVA. The generator set shall be capable of "^- recovering to a minimum of 90% of rated no load voltage following the application or the specified kVA load at near zero power factor applied to the ! generator set. Page 7 of 25 RX DatelTlme FEB-iT-Z009 iO:35P~ 02/18/2009 10:45 FROM-Cum~ins Northwest +425235 8202 +425-235-82DZ T-08Z P.OI4/031 (b) P.014 H80 5. The alternator shall produce a clean AC vollage I wavefonn. with not more than 5% total harmonic dis1artion at full linear load, when measured from line k to neutral, and with not more than 3% in any single hannonic. and no Jill order harmonics or their multiples. Telephone influence factor shall be less than 40. 6. The generator set shall be certified by the engine manufacturer to be suitable for IJse at the installed X location, and shall meet all applicable exhaust emission requirements at the time of commissioning. C. Construction 1. The engine-generator set shall be mounted on a ''1 heavy-duty steel base to maintain alignment between components. The base shall incorporate a battery tray with hold-down clamps within the rails. 2. All switches, lamps, and meters in the control system shall be oil-tight and dust-tight All active control 'k components shall be installed within a UUNEMA 3R enclosure. There shall be no exposed points in the control (with the door open) that operate in excess of 50 volts. 0_ Connections 1. A three position rotary selector switch to reconfigure the output voltage between any three combinations ot X. a. Low wye (120/208 VAC) b. Series delta (120/240 VAC) c. High wye (2n/480 VAC) 2. Thermal magnetic UL listed. shunt trip main line circuit breakers rated at 600 VAC 200 amps must be mounted on the side at the AC connection panel. X The line side connections are to be made at the factory. Equip the shunt trip circuit breaker to coordinate with the Crouse-Hinds Posi-Lok.limit switch and de-energize the circuit breaker when not ;5 use. Page 8 of 25 RX DatelTime FEB-IT-ZQ09 10:35PM 02/18/2009 10:45 FRO~-Cumnins Northwest +425 235 8202 +425-235-8202 T-082 P Oi5/031 (& P.01S H8D 3. Generator Main Line Circuit BreaKels: Provide molded case, 3 pole. minimum of 22,000 amp "1. interrupting capacity. provide separate breakers rated at 250 amps, 600 VAC and 500 amps, 240 VAe. 4. High wye (2771480 VAC): Install a Crouse-Hinds AC Power DIstribution System Posi-Lok panel. Model E0200-1662LS-S, connected to the 200 amp, 600 VAC main line circuit breaker. The limit switch on the X. Posi-Lok panel shall be wired to the shunt trip on the main line circuit breaker, such that the shunt trip breaker cannot be dosed until the 5th connector is inserted fully, and will trip the breaker if the 5th connector is rotated. Posl-Lok panel shall be wired for clockwise phase rotation for Black-Roo-Blue sequence. 5. Series delta (120/240 VAC): Install receptacle for f... standard three prong 120 VAC. 6. Low wye (1201208 VAC): Install lugs set up for 3 pole 240 VAC main line breaker. Maintain clockwise ~ phase rotation for L 1-L2-L3 sequence. MEETS 2.03 ~ Engine and Engine Equipment SPEC? COMMENTS YES NO A. The engine shall be diesel, 4 cycle, radiator and fan C) U b,. I Nts , c.. of ,-, ~ ill.. p.. , ij c:fe.1J. cooled. Minimum displacement shall be 543 cubic inches, ~ 40B c. U. I N ((,. (, '1 L) with S cylinders. The horsepower rating of the engine at its minimum tolerance level shall be sufficient to drive the {!/>J u I N' t. ~ T Pl!. 5' l\j c,u. ,,.I. alternator and all connected accessories. Two cycle engines 1!.r4G.I~! (.5 I~" L 0 rJ G e P- are not acceptable. A",.! U-B\..! ~~ft T f,U l50 tl.u.J C(~l!~A-z'o"-. [j) oc'T t1.. a t! ~ C. u.J.:... M t1. If: 1 J:. LoJ\.o ~ f(c..lfl~~"'fI~I'J' C3.n'l{J..'~ , Page 9 of 2S RX DateJTime FEB-17-Z009 10:35PM 02/18/2009 10:45 FROM-Cu[mln& Northw9&t .425 235 8202 +4Z5-235-8Z02 Engine accessories and features shall include: B. An electronic governor system shall provjde automatJc isochronous frequency regulation. The governing system dynamic capabilities shall be controlled as a function of engine coolant temperature to provide fast, stable operallon at v8J}'ing engine operating temperature conditions. The control system shall actively control the fuel rate and excitation as appropriate to the state of the generator set. Fuel rate shall be regulated as a funcUon of starting, accelerating to start disconned speed, accelerating to rnted speed. The governing system shall include a programmable wann up at idle and cool down at idle function. While operating in idle state. the control System shall disable the alternator excitation system. c. Skid-mounted radiator and cooling system rated for full load operation in 122 degrees F (50 degrees C) ambient as measured at the generator air inlet, based on 0.5 in H~O external static head. Radiator shall be sized based on a core temperature that is 20F higher than the rated operalion temperature, or prototype tested to verify cooling perfonnance of the engine/radiator/fan operation In a controlled environment.. The cooling system shall be filled with a SO/50-ethylene glycol/water mixture by the equipment manufacturer. Rotating parts shall be guarded against accidental contact o. Electric starter(s) shall be capable of three complete cranking cycJes without overheating. E. Unit shall inClude a positive displacement. mechanical, full pressure, lubrication oil pump. F. Full flow lubrtcation oil filters with replaceable spin-on canister elements and dipstick oil level indicator. G. An engine driven, mechanical, positive displacement fuel pump. Fuel filter with replaceable spin-on canister element Fuel cooler, suitable for operation of the generator set at full. rated load in the ambient temperature specified shall be provided jf required for operation due to the design of the engine and the installation. H. Replaceable dry element air cleaner with restriction indicator. Page 10 of 25 x "" x '" x ~ '" T-082 P.016/03! ~ P.016 H80 RX DateJTime FEB-I7-2009 JD:35PM 02/18/2009 10:45 FROU-Cummlns Northwest +425 235 8202 +-4ZS-Z35-SZ0Z T-asz p.D171a31 VY P.017 F-ssa I. Flexible supply and return fuel lines. X J. Engine mounted battery charging allernator, 40-ampere 'J.. minimum, and solid-state voltage regulator. K. Coolant heater 1. Engine mounted. thermostatically controlled. coolant X heater. Heater voltage shall be 120VAC. The coolant heater shall be UL499 listed and labeled. 2. The coolant heater shall be installed on the engine with silicone hose connections. Steel tubing shall be X. used for connections into the engine coolant system wherever the length of pipe run exceeds 12 inches. 3. The coolant heater installation shall be specifrcally designed to provide proper venting of the system. The coolant heater shall be installed using shutoff X valves to Isolate the heater for replacement of the heater element. The valves shall allow the heater element to be replaced without draining the engine cooling system or significant coolant loss. 4. The coolant heater shall be provided with a DC thennostat, installed at the engine thermostat X housing. An AC power connection box shall be provided for a single 120VAC power connection to the coolant heater system. S. The coolant heater(s) shall be sized as recommended by the engine manufacturer to warm the engine to a minimum of 104F (40C) in a 40F (4C) X ambient, in compliance with NFPA110 requirements, or the temperature required for starting and load pickup requirements of this specification. S. Install an electrical junction box for the coolant heater and battery charger. Install separate circuit breakers for the coolant heater and battery charger. On the X line side for the circuir breakers, connect to a flanged weatherproof inlet, 20 ampere. 125 V NEMA 5--20P configuration. The connected load for the coolant heater and batlery charger shall be limited to 16 amperes combined. Page 11 of 25 RX Date/Time FEe-17-2009 IO:35PM 02/18/2009 10:45 FROM-Cummins Northwest .4252358202 +425-235-8Z0Z L Provide vibration isolators. spring/pat! type. quantity as recommended by the generator set manufacturer. M. Starting and Control Battery(s) shall be calciuml1ead antimony type, 24 volt DC, sized as recommended by the engine manufacturer. complete with battery cables and connectors. N. Provide eXhaust silencer for engine of size and type as recommended by the generator set manufacturer and approved by the engine manufacturer. Exhaust system shall be Installed accotding to the engine manufacturer's recommendations and applicable codes and standards. O. A UL IIstedlCSA certified 10 amp voltage regulated battery charger with 120 VAC power supply shall be provided and installed in the generator enclosure, Input AC voltage and DC output voltage shall be as required. Charger shall be equipped with noat. laper and equalize charge settings. Operational monitors shall provide visual output along with individual form C contacts rated at 4 amps, 120 VAC, 30VDC for remole indication of: 1. Loss of AC power- red light 2, Low battery voltage - red light 3. High battery voltage ~ red light 4. Power ON - green light (no relay contad) Charger shall include an Analog DC voltmeter and ammeter, 12-hour equalize charge timer, and AC and DC fuses. Page 12 of 25 ~ x. )( 1\ T-OSZ P a1S/031 @ P.01S HSO RX DatelTime 02/18/2009 10:45 FEB-IT-ZOOe IO:36PM FROM-Cummins Northwest +425 2358202 +425-235-8202 P.019 T-082 P 019/03J F-680 CiY MEETS 2.04 - AC Generator SPEC? COMMENfS YES NO A. The AC generator shall be; synchronous. four pole, 2/3 pitch, revolving field. drip-proof construction, single pre- lubricated sealed bearing, air cooled by a dIrect drive centrifugal blower fan, and diredly connected to the engine 'J... with flexible drive disc. All Insulation system components shall meet NEMA MG1 temperature limits for Class H insulation system. Actual temperature rise measured by resistance method at full load shall not exceed 125 degrees Cent/grade. B. The generator shall be capable of delivering rated output X (kVA) at rated frequency and power factor, at any voltage not more tnan 5 percent above or below rated voltage. C. A pelTl'lanent magnet generator (PMG) shall be Included to prOVide a reliable source of excitation power for optimum motor starting and short circuit perfonnance. The PMG and ~ controls shall be capable of sustaining and regulating current supplied to a single phase or three phase fault at apprOximately 300% of rated current for not more than 10 seconCls. D. The subtransient reactance of the alternator shall not exceed 12 percent, based on the standby rating of the X generator set. MEETS 2.05 - Generator Set Control SPEC? COMMENTS YES NO A. The generator set shall be provided with a mic;roprocessor-based control system that is designed to provide automatic starting, monitoring, and control functions for the generator set. The control system shall also be X designed to allow tocal monitoring and control of the generator set. The control shall be mounted on the generator set. The control shall be vibration isolated and prototype tested to verify the durability of all components in the system under the vibration canditions encountered. Page 13 of 25 RX DatelTlme FE8-17-2009 IO:36PM 02/18/2009 10:45 FRO~~Cummins Northwest +4252358202 +425-235-8202 T-082 P.Q20/031 (0 P,020 H80 B. Control Switches The generator set mounted control shall include the following features and functions: 1. MODE SELECT Switch. The mode select switch J.. shall initiate the following control modes. When in the RUN or Manual position the generator set shall start, and accelerate to rated speed and voltage as directed by the operator. In the OFF position, the generator set shall immediately stop, bypassing all time delays. In the AUTO poslUon. the generator set shall be ready to accept a signal from a remote device to start and accelerate to rated speed and voltage. 2. EMERGENCY STOP switch. SWitch shall be Red "mushroom-head" push-button. Depressing the emergency stop switch shall cause the generator set 'i.. to Immediately shut down and be locked out from automatic restarting. 3. RESET switch. The RESEr switch shall be used to clear a fault and allow restarting the generator set ~ after it has shut down for any fault condition. 4. PANEL LAMP switch. Depressing the panel lamp switch shall cause the entire panel to be lighted with DC control power. The panel/amps shall X automatically be switched off 10 minutes after the switch Is depressed or after the switch is depressed a second time. C. Generator Set AC Output Metering The generator set shall be provided with a metering set Including the following features and functions: 1. Analog voltmeter, ammeter, frequency meter, power X. factor meter, and kilowatt (KW) meter. Voltmeter and ammeter shall display all three phases. Meter scales shall be color coded In the following fashion: green shall indicate normal operating condit/on, amber shall indicate operation in ranges that indicate potential failure, and red shall indicate failure impending. Metering accuracy shall be within 0.5%. Page 14 of 25 RX Date/Time 02/18/2009 10:45 FEB-17-2009 IO:36PM FRDU-Cummlns Northwest +425235 8202 +42H35-8202 P.021 T-082 P 021/031 F-68D 2. Digital metering set, 0.5% accuracy, to indicate generator RMS voltage and current, frequency, output current. output KW, KW hours, and power "A factor. Generator output voltage shall be available in line-to-lIne and IIne-ta-neutral voltages, and shall display all three-phase voltages (line to neutral or line to line) simultaneously. 3. The control system shall monitor tne total load on the generator set, and maintain data logs of total X. operating hours at specific load levels ranging from 0 to 110010 of rated load, in 10% increments. The control shall display hours of operation at less than 30% load and total hours of operation at more than 90% of rated load. 4. The control system shall log total number of operating hours, tatal KWH. and total control on ~ hours, as well as total values since reset. 5. 80th analog and digital meteling is required. The analog and digital metering equipment shall be driven "A by a single microprocessor, to provide consistent readings and performance. D. Generator Set AJann and Status Display 1. The generator set control shall include LED alann and status Indication lamps. The lamps shall be "k high-intensity LED type. The lamp condition shall be clearly apparent under brighllighting conditions. Functions indicated by the lamps shall include: 2. The control shall include five configurable alarm- X indicating lamps. The lamps shall be field adjustable for function, color. and control action (status, warning, or shutdown). 3. The control shall include green lamps to Indicate the generator set is running at rated frequency and voltage, and thai a remote start signal has been received at the generator set. Tfte running signal 'A shall be based on actual sensed voltage and frequency on the output terminals of the generator set. @ Page 15 of 25 RX DatelTime 02/18/2009 10:45 FEB-IT-2009 10:36PM FROM-Cummins Northwest +425 235 8202 +425-235-8202 P.022 T-082 P.022/031 F-S80 @ 4. The control shall include a flashing red lamp to indicate the control is not in automatic state and red "'- common shutdown lamp. 5. The control shall include an amber common warning 'A. indication lamp. 6. The generator set control shall indicate the existence of the following alarm and shutdown conditions on an l( alphanumeric digital display panel: a. low oil pressure (alarm) b. low oil pressure (shutdown) '" c. 011 pressure sender faiJure (alann) X d. low coolant temperature (alarm) :A e. high coolant temperature (alann) }< f. high coolant temperature (shutdown) )( g. high oil temperature (warning) i. . h. engine temperature sender failure (alarm) 'J... i. low coolant level (alarm or shutdown-selectable) X J. fail to crank (shutdown) )( k. fail to startlovercrank (shutdown) X I. overspeed (shutdown) X m. low DC voltage (alarm) X n. high DC voltage (alarm) ~ o. weak battery (alarm) X p. low fuel-daytank (alarm) X Page 16 of 25 RX DatelTime FEB-IT-2009 10:36PM 02/18/2009 10:45 FROM-Cummins Northwest +425 235 8202 +4Z5-235-BZ02 T-082 P.023/031 CiY P.023 H8D q. high AC voltage (shutdown) "1- r. low AC voltage (shutdown) X. s. under frequency (shutdown) X t. over current (warning) X. u. over current (shutdown) X v. short circuit (shutdown) X w. over load (alarm) X x. emergency slop (shutdown) 'A. 7. Provisions shall be made for indication of four customer-specified alarm or shutdown conditions. Labeling of the customer..specified alann or shutdown conditions shall be of the same type and quality as X. the above-specified conditions. The non-automatic indicating lamp shall be red, and shall flash to indicate the generator set is not able to automatically Il!spond to a command to start from a remote location. 8. The control shutdown fault conditions shall be X configurable for fault bypass. I E. Engine Status Monitoring 1. The following infofTTlation shall be available from a digital status panel on the generator set control: "'- a. engine oil pressure (psi or kPA) b. engine coolant temperature (degrees F or C) X. c. engine oil temperature (degrees F or C) "^ d. engine speed (rpm) X e. number of hours of operation (hours) X Page 17 of 25 RX Date/Time FEB-IT-ZOC9 lO:36PM 02/18/2009 10:45 FROM-Cummins Northwest +425 235 8202 +425-235-820Z T-C92 P.C24/031 ([j P.024 Hao f. number of start attempts x.. g. battery voltage (DC volts) X 2. The control system shall also incorporate a data logging and display provision to allow logging of the last 10 warning or shutdown indications on the generator set, as well as total time of operation at ~ various loads, as a percent of the standby rating of the generator set. F. Engine Control Functions. 1. The control system provided shall include a cycJe crankIng system, Which anows for user selected crank time, rest time, and # of cycles. Initial settlngs X. shall be for 3 cranking periods of 15 seconds each. with 15-second rest periOd between cranking periods. 2. The control system shall include an idle mode control, which allows the engine to run in idle mode In X. the RUN position only. In this mode, the alternator e.xcltatlon system shall be disabled. , 3. The control system shalllncJude an engine governor cantro', which functions to provide steady state frequency regulation as noted elsewhere in this "I... specification. The governor control shall include adjustments for gain, dampino, and a ramping function to control engine speed and limit exhaust smoke while the unit Is starting. 4. The control system shall Include time delay start (adjustable 0-300 seconds) and time delay stop X. (adjustable 0-600 seconds) functions. 5. The control system shall include sender failure monitoring logic for speed sensing, oil pressure. and X. engine temperature which is capable of discriminating between failed sender or Wiring components. and an actual faUure conditions. Page 18 of 25 RX DatelTime FEB-17-2009 IO:36PM 02/18/2009 10:45 FRO~~Cummin6 Ncrth~eit +4252358202 +m-235-B202 T-OB2 P.02S/03! (it) P.025 HBQ G. Alternator Control Functions 1. The generator set shall include a full wave rectified automatic digital vollage regulation system that is matched and prototype tested by the engine manufadurer With the governing system provided. It shall be immune from misoperation due to load- induced vo"age waveform distortion and provide a pulse width modulated output to the alternator exciter. The voltage regulation system shall be equipped with three-phase RMS sensing and shall control buildup of AC generator voltage to provide a 'J.. linear rise and limit overshoot The system shall include a torque-malching characteristic. which shall reduce output voltage In proportion to frequency below an adjustable frequenc)' threshold. Torque matching characteristic shall be adjustable for roll-off frequency and rate, and be capable of being curve- matched to the engine torque cUlVe with adjustments in the field. The voltage regulator shall include adjustments for gain, damping, and frequency roll-off. Adjustments shall be broad range, and made via dig ita' raise-lower switches, with an alphanumer1c LED readout to Indicate setting level. Rotary potentiometers for system adjustments are not acceptable. 2. Controls shall be provided to monitor the output current of the generator set and initiate an alann (over current warning) when load current excee<<ts "'^ 110% of the rated current of the genenltor set on any phase for more than 60 seconds. The controls shall shut down and lock out the generator set when output current level approaches the thermal damage point of the alternator (over current shutdown). The protective functions provided shall be in compliance to the requirements of NFPA70 article 445. Page 19 of 25 RX Date/Time FEB-17-Z009 lO:36PM 02118/2009 10:45 FROM-Cum~!ns Northwest +425 235 8202 +425-235-8202 T-08Z P.026/03! Ci9 P.026 F-680 3. Controls shall be provided to individually monitor all three phases of the output current fOr short circuit conditions. The control/protection system shall monitor the current level and voltage. The controls shall shut down and lock out the generator set when "^ output current level approaches the thenoal damage point of the alternator (short circuit shutdown). The protective functions provided shall be in compliance to the requirements of NFP A 70 article 445. 4. Controls shall be provided to monitor the KW load on the generator set, and initiate an alarm condition (over load) when total load on the generator set exceeds the generator set rating for in excess of 5 'A seconds. Controls shall indude a load shed control, to operate a set of dry contacts (for use in shedding customer load devices) when the generator set is overloaded. 5. An AC over/under voltage monitoring system that responds only to true RMS voltage conditions shall be provided. The system shall initiate shutdown of the generator set when alternator output voltage X exceeds 110% of the operator-set voltage level for more than 10 seconds, or with no intentional delay when vOllage exceeds 130%. Under voltage shutdown shall occur when the output voltage of the altemator is less than 85% for more than 10 seconds. Page 20 of 25 RX DatelTime 02/18/2009 10:45 FEB-17-2D09 IO:37PM FROM-Cu~mln5 NorthwBst +425 235 8202 +425- 235 -8 202 P.027 T-082 P.D27/031 F-S80 PART 3 - OPERATION cfY MeETS 3.01 . Sequence of Operation SPEC? COMMENTS YES NO A. Generator set shall start on receipt of a start signal from remote equipment. The start signal shall be via hardwired X. connection to the generator set control. B. The generator set shall complete a time delay start period 'i as programmed into the control. C. The generator set control shaH initiate the starting sequence for the generator set. The starting sequence shaJl X include the following functiDns: 1. The control system shall verify that the engine Is rotaling when the starter is Signaled to operate. If the engine does not rotate atter two attempts, the control system shall shut down and lock out the generator set, and indicate "fall to crank" shutdown. 2. The engine shall fire and accelerate as quickly as practicaJ to start disconnect speed. If the engine does not start, it shall complete a cycle cranking process as described elsewhere in this speciffcatlon. ~ , If the engine has not started by the completion of the cycle cranking sequence, it shall be shut down and locked out, and the control system shall indicate "fail to start'. 3. The engine shall accelerate to rated speed and the alternator to rated voltage. Excitation shaH be disabled until the engine has exceeded programmed 'f.... idle speed, and rugulated to prevent over voltage conditions and oscillation as the engine accelerates and the altemator builds to rated voltage. 4. On reaching rated speed and voltage, the generator set shall operate as dictated by the control system in "'- isochronous state. 5. When all start signals have been removed from the generator set, it shall complete a time delay stop X. sequence. The duration of the time delay stop period shall be adjusta!)le by the operator. 6. On completion of the time delay stop period. the 'A. generator set control SWitch off the excitation system and shall shut down. - Page 21 of 25 KX Uate/llme FEB-17-2009 10:37PM U~/1tH~UU~ 10:45 FROM-Cummins Northwest +425 235 8202 +425-235-8202 T-082 P 028/031 @ P.02S HaD 7. Any start signal received after the time stop sequence has begun shall immediately terminate the X stopping sequence and return the generator set 10 isochronous operation. - Page 22 of 25 RX oatelTime FEB-17-2009 10:37PM 02/18/2009 10:45 +4252358202 P.029 FROM-Cummins Northwnt +425-235-8202 H82 P 029/031 H8D @8) PART 4 - OTHER REQUIREMENTS MEETS 4.01 . Submittals SPEC? COMMENTS YES NO A. VVithin 10 days after award of contract. provide four sets of the following information for review: 1. Manufacturer's product literature and performance X data. sufficient to verify compliance to specification requirements. 2. A paragraph by paragraph specification compliance statement. describing the differences between the )( specified and the proposed equipment. 3. Manufacturer's certification of prototype testing. '/.. 4. Manufacturer's published warranty documents. ~ 5. Shop drawings showing plan and elevation views X wIth certified overall dimensions, as weU as wiring interconnection details. 6. Interconnection wiring diagrams shoWing all external connedions required, with field wiring terminals ~ marked in a consistent point-ta-polnt manner. 7. Manufacturer's installation instructions. }{ MEETS 4.02 - Factory Testing SPEC? COMMENTS YES NO A. The generator set manufacturer shall perform a complete operational test on the generator set prior to shipping from the factory. A certified test report shall be provided. 'k Equipment SUpplied shall be fully tested at the (actory for fundio" and performance. 8. Factory testing may be witnessed by the owner and I consulting engineer. Costs (or travel expenses will be the X responsibility of the owner and consulting engineer. Supplier is responsible fo provide two weeks notice for testing. Page 23 of 25 RX DatelTime FEB-iT-ZDD9 10:3TPM 02/18/2009 10:45 FROM-CuT.mlns ~orthwest +425 235 8202 +425-235-8202 T-082 P.03D/031 6g) P.030 F-68Q c. Generator set factolY rests on the equipment shall be perfoffiled at rated load and rared power factor. Generator I sets that have not been factory tested at rated power factor "" will not be acceptable, Tests shall include: run at full load, maxImum power, voltage regulalion, transient and steady- state governing, single step load pickup, and function of safety shutdowns. D. Equipment shall be initially started and operated by 'iL representatives of the manufacturer. MEETS 4.03 On-Site Acceptance Test SPEC? COMMENTS YES NO A. Unit acceptance tests to be conducted on-site shall include a "cold start" test, a two hour fuU load test. and a one 'k step rated load pickup test in accordance with NFPA 110. Provide a resistive load bank and make temporary connections for full load test, if necessary. B. Test each alarm and all automatic shutdowns of the generator set. "^- C. Demonstrate correct phase rotation. ""- D. Demonstrate proper operation of engIne water jacket heater and battery charger. X. E. Contrador shall deliver and Install the complete electrical generating system accordance with theCity.s instructfons "^ after award of contract Fuel for site test will be provided by City unless unit is rejected. On-wheel delivelY Is allowable. MEETS 4.04 Training SPEC? COMMENTS yes NO A. The equipment supplier shall provide training for the facility operating personnel covering operation anct i maintenance of the equipment provided. The training program shall be not less than 4 hours in duration and the class size shall be limited to 10 persons. Training date shall be coordinated with the facility owner. Page 24 of 25 RX DatelTime FEB-IT-200S JO:37PM 02/1 8/2009 10:45 FROM-Cummins Northwest +425 235 8202 +425-235-8202 T-092 P 031/031 ~ P.031 HaD MEETS 4.05 - Warranty SPEC? COMMENTS YES NO A. The generator set and associated equipment shall be warranted for a period of not less than 5 years from the dale X of commissioning against defects in malenals and workmanship. B. The warranty shall be comprehensive. No deductibles shall be allowed fDr travel time, service hours, repair parts ~ cost, etc. I MEETS 4.06 Owner's Manuals SPEC? COMMENTS YES NO A. Provide three sets Df owner's manuals specific to the product supplied and must accompany tho equipment on delivery. The general operating Instructions. preventative X. maintenance, wiring diagrams, schematics, and partS exploded view specific to this model must be Included. Page 25 of 25