HomeMy WebLinkAbout2173 ORDINANCE NO. 2173 v[2~-~ ,~2'~_.~ ~
AN ORDINANCE regulating the erection, construction, enlargement,
alteration, repair, moving, removal, conversion, demolition, occupancy,
equipment, use, height, area and maintenance of buildings or structures
in the City of Bremerton, providing for the issuance of permits and col-
lection of fees therefor, declaring and establishing fire districts, pro-
viding penalties for the violation thereof and repealing Ordinances No.
1418, 1582, 1583, 1542, 1561, 1593, 1616, 1718, 1766, 1942, 1970, and
all Ordinances and parts of ordinances in conflict therewith.
THE CITY OF BREMERTON DOES ORDAIN:
Section 1. That a certain document, three copies of which are on
file in 't~e Office ol the City Clerk in the City of Bremerton, being de-
signated and marked as the Uniform Bulldlng Code, l~ Edition, be and
the same hereby is, with ~he following amend~uents, adopted as the Build-
ing Code of the City of Bremerton, regulating the erecbion, construction,
enlargement, alteration, repair, moving, removal, conversion, demolition,
occupancy, use, height, area and maintenance of buildings or structures
in the City of Bremerton, providing for the issuance of permits and col-
lection of fees therefor, declaring and establishing fire zones, provid-
ing penalties for the violation of said Code and each and all of the con-
ditions, provisions, regulations, penalties and terms of such Uniform
Building Code, 1955 Edition, with amendments, on file in the office of the
Oity Clerk, are hereby adopted and made a part hereof as if fully set forth
in this Ordinance.
Section 2. That Ordinances No. 1418, 1582, 1583, 1542, 1861, 159Z,
1618, ~'%~1~, 1768, 1942 and 1970 and all other ordinances or parts of ord-
inances in conflict therewith are hereby repealed.
Section 3. The City Clerk of the City of Bremerton shall keep on
file in his office at least three (3) copies of said Uniform Building
Code, 198~ Edition, with ~he following amendments, for the use of the
general puDlic and shall provide for such additional copies for sale,
distribution, or other use to persons interested, as shall be determined
by the City Commission.
Section 4. That Section ~0~ of the Uniform Building Code, 1958
Edition, is amended by adding thereto Sections £02-F, ~02-G and 20~-h,
to read as follows, to-wit:
"Section ~02-F. Liability: Any officer or employee charged
with the enforcement of this Code, acting for the City in
the Discharge of his duties, shall not thereby render himself
liable personally. He is hereby relieved from all personal
liabilities for any damage that may occur to persons or pro-
petty as a result of any ac~ required or permitted in the dis-
charge of his duties; any suit brought against an officer or
employee because of such act performed by him in the enforcement
of a provision of this Code shall be defended by the City of
Bremerton until the final termination of the proceedings. The
City of Bremerton agrees to indemnify all e~ployees of the City
Building Department for any and all personal liability ~hey incur
in the performance of ~heir official duties."
"Section 20~-g. Demolition. Handling of materials: All materials
shall be handled within the building area or within the area bounded
by a barricade approved by the Building Official."
"Section 202-h. Prevention of dust; All debris shall be suffic-
ently wet at all times of handling to prevent dust from arising."
Section 8. That Section 801-c of the Uniform Building Code, 1985
Edition, 'is'~'reby amended to read as follows:
"Section ZOl-c. Plans and Specifications. There shall be
filed with bhe application for permit two (~) sets of printed
drawings and specifications fully describing the extend and
natu~e of the work for which the permit is desired. They
shall also show the location of the proposed building or other
structure and of every existing building or structure on the
site or lot. Computations, strain sheets, stress diagrams and
other date necessary to show the correctness of the plans
shall accompany the plans and specifications when required by the
the building official. Should such drawings or specifications
be incomplete, indefinite, or unintelliOle, the building official
Ordinance No. 2173 (Con't)
shall reject the same and refuse to issue a permit based there-
on. All such printed drawings shall be made to a scale and not
less than one-eithth (1/8) of an inch to the foot, shall show all
necessary distances and dimensions and Shall be accurate, explicit
and complete. All drawings submitted with the application for
permit except for those provisions as listed below, shall be pre-
pared by or under the direction of an architect licensed to prac-
tice architecture in the State of Washington, and each sheet
thereof shall bear the signature and seal of said architect; or
the drawings shall be made by or under the direction of a struct-
ural engineer who is licensed as such by the State of Washington,
in which case each sheet shall bear signature and seal; provided,
however, that any person who is capable of making~drawings which
conform to the requirements of the 'building code may prepare same
for the contemplated work on a building or other structure which
does, or will when completed, belong to said person, inwh~ch case
each sheet shall bear the owner's signature and~certify that the
drawings were prepared by said owner.
Exceptions: ~hen authorized by the building official, plans and
specifications need not be submitted for the following:
1. One story buildings of Type V convemtional wood-stud
construction with an area not exceeding 600 square
feet.
E. Group 1, Section 1401 and Group J, Section 1501,
Division 1, occupancies of Type V conventional
wood-stud construction;
3.Small and unimportant work,
Provided, however, that every application for permit must be
accomp~nied by two (~) printed drawings of the site or plot
indicating the legal description, address, location of the
proposed building and of every existing building on the pro-
perty. The property owner shall certify that the proper cor-
ners of the property to be built on are correct, or shall
submit two (~) printed drawings of a survey of the property
prepared by a civil engineer licensed to practice in the
State of Washington."
Section 6. That Section 304 of the Uniform Building Code, 1955
EditiOn, is amended by adding thereto Section 304-a (1) to read as
follows:
"Section 304-a (1) Regardless how estimate cost is deter-
mined for a building or structure, no deduction shall be
made of the cost of any ~lectrical, Plumbing, Furnace or
other installations for which a separate permit is required."
Section 7. The second paragraph of ~ection 40~ is hereby amended
to read as foilows:
"Section ~05. D~ELLINGS: ~ere used in ~his code shall mean a
detached building ordinarily occupied by one family exclusiv~y, as
a dwelling place and the usual sccessory buildings, provided that
such building shall no~ be occupied by more than two families, with
the usual accessory buildings."
Section 8. The first paragraph of Section 407 is hereby amended to
rea~ as follOws:
"Section ~07. FANILY: Family is one person living alone or any
number of related individuals, ~ut not mo~e than five ~) unrelated
persons livin~ togeDher as a single housekeeping unit, and doing
their cooking on ~he premises including domestic help."
Section 9. That Section 408 of the Uniform Building Code, 19~5
Edition, is amended by substituting the following paragraph in lieu of
the s~cond un, numbered paragraph ~nd by subsequently adding thereto
Sections ~08-a and 408-b.
"Section 408. PRIVATE GARAGE: Private garage is a building or por-
tion of a building not more than Six Hundred and Fifty (650) square
feet in area in which only ~otor vehicles used for tenants of the
building or Ouildings on ~he premises are stored or Xept. Carport
is a building, open on two sides or more, used for ~he tenants of
the buildings on the premises, where cars are ~tored or ~ept. They
shall meet the same requirements as a private garage."
Ordinance No~ 217~ (Cch't)
"Section 408-a. A grage or car-port is at~ached to a residence
by a breezeway. Fire protection may be omitted if attached gar-
age or carport is 5' or more from the dwelling provided any con-
cealed or enclosed space in such breezeway shall be effectively
fire-stopped, as required for the separated wall."
"Section 408-b. Garage for Business establishments; is a build-
ing or a portion of a building for the storage or repair of motor
vehicles owned by a business and uses solely for conducting the
business. Where no storage or repair is done for others, or the
general public, it shall oe considered a business house garage."
Section 10. That the fifth un-numbered paragraph of Section 420
of the Unifbrm'Building Code, 1955 Edition is hereby amended to mead
as follows:
"Section 420. STORY. Story is that portion of a building in-
cluded between the upper surface of any floor and the upper surface
of the floor next above, except that the topmost story shall be that
portion of a building included between ~he upper surface of the top-
most floor, and the ceiling or roof above. A basement shall not be
considered a story unless 50 per cent or more of its area is used as
a place of habitation, or where 50 per cent or more of its area is
used for general public, (such as a salesroom).
Section ll. That Section 505 of the Uniform Building ~ode, 1955
Edition, 'Is amended by substituting the following paragraph 505-c and
by subsewuently adding thereto Sections 505-d, 505-e, 505-f, 505-g,
505-h, and by amending Table 5-C to read as follows, to-wit:
"Section 505-c. Separation areas Fire Walls.
(1) Fire walls shall be so located in buildings that the
floor area between exterior walls or between exterior walls and
fire walls does not exceed the floor area limits of Table 5-C.
(2) Fire walls shall re so located that the aggregate
floor area between exterior wall or between exterior wall and
fire walls of adjoining buildings utilizing walls a~apted for
joint service between 2 buildings does not exceed the floor
area limits of Table 5-C."
"Section 505-d. (1) Fire walls shall be of non-combustible
material having a fire resistance rating of not less than 4
hours, and have sufficient structural stability, under fire
conditions, to allow collapse of construction on either side
without collapse of the wall.
(2) Walls constructed of solid masonry or of hollow masonry
units or of reinforced concrete shall be considered as meeting
the above requirements for structural stability under fire con-
ditions when conforming to this Section 505-c and, .except as
otherwise specifically provided in this Section, also conforming
to Chap~r 23, 24 and 26.
(3) Fire walls shall start at the foundations and extend
continueusly through all stories to and above the roof, except
where the roof is of fire-resistance construction and the wall
is carried up tight against the under side of the roof slab.
(4) Where structural members project into hollow masonry
units, the hollow space shall 0e filled with noncombustible
material the full thickness of the wall and 6 inches or more
above, between and below such member."
"Section 505-e. (1) Thickness of solid masonry walls except
panel wa~lls. Fire walls of solid masonry shall 0e not less
than 12 inches thick for the uppermost 35 feet of their
height, and shall 0e increased 4 inches in thickness for each
successive 35 feet or fraction thereof measuring downward
from the top of the wall.
(2) ~here solid masonry fire walls are stiffened at dis-
tances not greater than 12 feet apart by masonry cross walls
or by reinforced concrete floors or roof, they may be 12 inches
thick for the upMermost 70 feet, measured downwards from the
top of the wall, and shall be increased 4 inches in thickness
for each successive 70 feet or fraction thereof."
Section 505-f. (1) Thickness of hollow masonry walls except
panel walls: Fire Walls of hollow masonry units including
brick-faced hollow masonry walls shall have a total thickness
of not less than 4 inches greater than required in Section e-1
for solid masonry walls."
Ordinance No. 2175 (Con't)
"S$ction 505-g. (1) Thickness of reinforced concrete walls
except panel walls. Fire walls of reinforced concrete shall
have a thickness of not less than 1/28 o£ the unsupported
height or width, whichever is the shorter, but in no case
shall it be less than 9 inches thick for the upper, host 55
fe~t and increase 2 inches in thickness for each ~uccessive
55 feet or fraction thereof measured downward from the top
of the wall.
(2) Exception.~tO~.thickness requirements for panel walls:
~here fire walls are constructed as panel walls in a framework
of columns and girders having fire resistance rating of not
less than 4 hours and no panel exceeds 40 feet in length nor
12 feet in height between supports, they may be 12 inches thick
if constructed of hollow masonry mnits or 8 inches if construct-
ed of solid masonry or reinforced concrete.
(Z) Parapets required: Parapets shall be provided on
fire walls in accordance with Section 170~e
"Section 50§-h. (1) Size and protection of openings: In
unsprinkled buildings no opening in a fire wall shall exceed
120 square feet in area with no dimension greater than 12
feet, and the aggregate width of all openings at any level
shall not exceed 25 per cent of the length of the wall; except
that in sprinkled buildings the size and aggregate width of
openings in a fire wall are not limited.
(2) Every opening in a fire wall required by Section
505-c (1) shall be protected on each side of the wall with an
approved automatic or self-closing fire-door; except that
when a fire wall serves also as a horizontal exit way it shall
have no openings other than door openings not exceeding 48
square feet in area, ~nd one of the doors at each opening
shall be a self-closing fire-door.
AREA TABLE
Table No. 5-C
Basic allowable Floor Area for Buildings One Story in.Height
(in square feet)
Area of one Area of Bldg.
Type of Construction story bldg. over one story
Type I no limit no limit
Type II 18,000 sq. ft. 12,000 sq. ft.
Type III - i hr.-H.T.* 12,000 sq. ft. 8,000 sq. ft.
Type III N* 9,000 sq. ft. !~6,000 sq. ft.
Type IV 9,000 sq. ft. 6,000 sq. ft.
Type V -lhr. 9,000 sq. ft. 6,0~O.S~. ft.
Type V N* 6,000 sq. ft. i~,000 sq. ft.
*N - No general requirements for fire resistance
*H.T. - Neavy Timber
Section 12. That Section 506-e of the Uniform Building Code,
1955 E~ition,' {s hereby amended to read as follows:
"Section 506-e. Unlimited Area: Outside of fire~ne l, the
area of any one or two story buildings of Group F, Group G
and Division 5 of Group E occupancies shall not be limited,
if the building is provided with an approved automatic fire
extinguishing system throughout, as specified in Chapter 58
and entirely surrounded by public space, street, or yards not
less than sixty (60') feet in width.
Section l~. ~A~hat Section 802 of the Uniform Building Code, 1955
Edition, is hereby amended by adding thereto a new Section 802-c, to
read as follows:
"Section 802-c. All interior walls, partitions, and under floor
usable spaces, when of metal or wood construction shall be not less
than one hour fire resistance."
Section 14. That Section 1002 of the Uniform Building ~Code, 1955 Edition
is hereby amended by adding thereto a new Section lO02-c, to read as fol-
lows:
Ordinance No. 2175 (Con't)
"Section 1002-c. Division 2-5-4- occupancy shall be constructed
of not less than one hour fire resistance or incombustible con-
struction throughout and shall not be more than one story in
height when of Type V construction."
Section 15. That Section 1008 of the Uniform Building Code, 1985
Edition, is hereby amended by adding thereto a new un-numbered paragraph
to read as follows:
"Every boiler or f~rnace room shall be separated from
the rest of the building by not less than one-hour fire resistance
construction throughout."
Section 18. That Section ll02 of the Uniform ButldingOode,
Edition,~s~eby amended by adding thereto a new Section, ll02-c to
read as follows:
Section ll02-c. Special provisions. Division 1-2 occupance
whall be of not less than one hour fire resistance construction
throughout."
Section 1V. That Section ll02 of the Uniform Building Code,
Editibn, is hereby amended b'j adding thereto a new Section, ll02-d, to
read as follows:
"Section ll02-d. Rat-proofing. Every building used for the stor-
age, sales, or ~andling of foods~for man or beast shall be pro-
vided with the following rat-proofing~
1. The floor of such building shall 0e on concrete not
less than three inches (5") thick laid directly on the
ground, unless such floor is over a cellar or base-
ment with a headroom of not less than six (8') feet.
The basement shall be provided with such concrete
floor.
2. The foundation of the exterior walls of such buildings
sha~l extend at least eighteen inches (18") below
grade on Ohe exterior of the building.
The walls of such buildings shall be rat-proofed with
masonry at least eight inches (8") above the finished
floors."
Section 18. That Section ll0S of the Uniform Building Code, 1958
Edition, is hereby amended by adding thereto two un-numbered paragraphs
to read as follows:
"Floor drains shall ~e provided in the toilet room of all taverns,
clubs and other places of business where the toilets are provided
for public use. Retail stores handling food shall be equipped with
at least one all purpose sink."
"The garage floors of service stations, par~ing lots, etc., where
cars are washe~ or stored, must provide for adequate floor and yard
drainage. Plans for drive-ways over sidewalks within ~he City of
Bremerton must ~e approved by the City Engineer p~ior to construc-
tion.''
Section 19. That Section ll08 of the Uniform Building ~ode, 1~5~
Editio~' is hereby amended by adding thereto an additional un-numbered
paragraph to read as follows:
"Every boile~~ or f~rnace room cont~ining a heating plant
shall be separated from the rest of ~he building by a one
hour fire resistive occupance separation."
Section 20. That Section 1JO2-b of the Uniform Building ~ode,19SS
Edition, is hereby amended to read as follows:
"Section 1002-b. Special provisions: Group H Occupance
more than on~ story in height or having more than three
thousand (ZOO0) square feet of floor area shall 0e of not
less than one hour fire resistance construction throughou~."
Section 21. That Section 1508 of the Uniform Building ~Code, 19~5
Edition, is hereby amended by adding thereto Sections 1ZOS-d, 1ZOB-e,
l~05-f, 1ZOS-g, & l~08-h to rea~ as follows:
Ordinance No. 2175 (Con't)
"Section 1Z08-d. Every place of habitation occupied by one
or more families, shall have constructed within each space
occupied by only one family, a room or rooms designed to
contain at least one toilet, bath or shower, lavatory, and
sink for the exclusive use of each family, also means must
be provided for the washing of clothes, such as laundry
trays or connections for automatic washing machines. There
shall be no direct openings from a room in which a water closet
is located into a room in which food is prepared or stored."
"Section l~OS-e. Rooms in which toilets are located in
restaurants or places ~here foods or confectionery is prepared,
concocted or manufactured for public consumption~or for sale,
must not open directly into any room where such work is being
carried on, but must be through a vestibule."
"Section l~05-f. Every room containing one or more toilets or
urinals shall be ventilated either by window opening to
the outer air by an individual vent duct or by mechanical
ventilating system installed and operated in accordance with
all the provisionsof the ordinances of the City of Bremerton
pertafnin~ thereto."
,Section l~05-g. Each sleeping room designed for the accom-
modation of mo~,e than one person shall provide not less than
five hundred 'twelve (512) cubic feet of air space for each
person of fourteen years of abe or over and not less than
three hundred cubic feet (300) of air space for each child
under fourteen years of age."
"Section 1305-h. No living or sleeping room in any place of
habitation, refuge or detention shall hereafter be built or
located in a cellar, rrovided, that there may be placed in
basements, rooms for living an~ sleeping purposes provided
that the floors of such rooms are not more than an average d
8epth of three feet (O') below grade and at no point shall
the fl~or be more than fiYe feet (B') below grade, and all
of such rooms are to be carefully checked and inspected by
the Building Inspector for light, ventilation and dryness.
No such living or sleeping rooms shall be located in any part
of a basement unless the exterior of the walls and the fl$or
of such room or rooms are rendered damp-proof."
Section ~. That Section 1308 of the Uniform Building ~ode,
Edition, is hereby amended by adding thereto an additional un-numbered
paragraph to read as follows:
"Boiler or furnace rooms containing a heating plant shall
be separated from the rest of the building by a two-hour
fire resistance occupancy separation."
Section ~. That Section 1~05 of the Uniform Building Code,
Edition, is hereby amended by adding thereto Sections l~O$-d and 1~05-
®, to read as follows:
"Section l~O8-d. Sani~ation: Every building or family
unit shall be provided with kitchen sink, lavatory, toilet
and bath or shower, for the exclusive use of each family,
also means must be provided for the washing of clothes,
such as laundry trays or connection for automatic washing
machine."
"Section l~O8-e. No living or sleeping room in any place of
habitation, refuge or detention shall hereafter be built or
located in a cellar, provided tha~ there may be placed in
basements, rooms for living and sleeping purposes provided
tha~ the floors o~ such z.ooms are not more than an average
depth of three feet (~') 0elow grade and at no poinO shall
the floor be more than five feet (8') below grade, and all
of such rooms are t be carefully checked and inspected by
the Builging Inspector for light, ventilation and dryness.
No such living or sleeping rooms shall ~e located in any
part of a basement unless the exterior of the wa~ls and the
floor of such room or rooms are rendered damp-proof."
Section ~. That Section 1~08 of the Uniform Building Code,
Edition, is hereby amended by adding thereto an additional un-numbered
paragrap~ to read as follows:
Ordinance No. 217~ (Con't)
"Where a furnace or similar heating device is placed in an
area occupied as a private garage; the heating device shall
be separated from the garage by ~ot less than one hour fire
resistance separation. Any openings from the garage into the
furnac~ area shall be protecte~ with a class~iE or F fire door.
An approved mental duct shall be provided leading directly .~
from the furnace room to the open air."
Section 20. That Section 801 of the Uniform Building Code, 1955
Edition, r~lating to Fire Zones is not adopted as part of this ordinance.
(See Ordinance No. 1867 relative to Fire Districts.)
Section 28. That Sectionl60~ of the Uniform Building Code,
Edition, is he4eby amended by adding thereto Section 1O0~-d to read as
follows:
"Section 1603-d. Buildings shall ~e of non. combustible con~
struction or of not less than one-hour fire resis'oance or as
permitted in Chapter 20 for Type III heavy timber construction.
Exterior walls less than ~wenty feet (20') from adjacent pro-
perty shall e not less than two (2) hour fire resistance
construction."
Section 27. That Section 1709 of the Uniform Building Code,
Edition, iS hereby amended in its entirety by substituting Sections
1709-a, 1709-b, 1709~c, 1709-d, 1709-e to read as follows:
"Section 1709-a. Except as listed below, parapets shall be
provided on all fire walls and exterior walls required to
have a fire resistance rating of 2 hours or more. Parapets
are not required on:
(1) Exterior walls and fire walls connecting with
roofs of fire resistance construction;
(2) An exterior wall of a building the roof of which
is at least $ feet lower than the roof of, or any
opening in, an adjacent building wall;
(~) Exterior wall facing on a street having a width
of ~0 feet or more;
(~) Exterior wall of a building which is ~0 feet or
More distant in all directions from the nearest
i line to which o~her buildings are or may be legally
built and from other buildings on the same lot;
(5) Exterior walls of a building which is $0 feet or
more distant in all directions from the nearest
line to which other buildings are or may '0e legally
built but less than ~0 feet distance to one or more
buildings on ohe same lot, where the total area of
~the buildings within ~0 feet of each other does not
exceed 1½times the allowable area for any one of
the buildings considered;
(8) Exterior walls of a detached dwelling, or of a
building not exceeding 1,O00 square feet in area;
(7) Exterior walls of a building where the roof has an
angle of more than 20 degrees with the horizontal.
"Section 1709-b. Parapets shall have fire resistance rating
not less than required for the exterior wall or fire alll
on which it is provided."
Section 1709-c. Parapets on exterior walls required to have
a fire resistance rating of 2 hours shall extend not less
than 2 feet above the roof; parapets on exterior walls re-
quired to have a fir~ resistance rating of ~ or ~ hours shall
extend not less than ~ feet above the roof; parapets on fire
walls shall extend at least to the same height as any part of
the roof through which the fire wall passes within lB feet of
the parapet and in no case shall it extend less than Z feet
above the point where the parapet and roof intersect."
"Section l?09-d. Masonry or reinforced concrete parapets
shall be at least as thick as the required thickness of the
wall on which it is provided but need not be more than 12
inches thick on exterior walls."
"Section 1709-e. Parapets shall 0e properly coped and
flashed with non-combusitble, weather-proof material. All
corners of ~sonry parapet wa±ls shall 0e reinforced with at
least one ~" bar in every third joint, continuous around the
corner and extending into the masonry at least 3 feet from
Ordinance No. 2175 (Con't)
Section 28. That Section 2Z12 of the Uniform Building Code, 1955
Edition, is h~'beb~ amended by adding thereto an additional un-numbered
paragraph to read as follows:
"All masonry buildings over six hundred and twenty-five (825) sq.
feet in area shall be provided with a reinforced concrete beam
at each floor or roof line above the ground floor, floor or roof
Joist shall be anchored to the Oond beam with joist anchors as
provided in Section 2517. It shall be reinforced with not less
than 4 pieces of 5/8" reinforced bars; reinforced bars shall ex-
tend around the corner not less than two (2) feet."
Section 29. That Section 251B-c of the Unifomn Building Code, 1955
Edition, is hereby amended to read as follows:
"Section 2515-c. Girders supporting first floor joists in
resident buildings shall ~e not less than six (6) inches by
six (6) inches for spans of six (6) feet or less, nor less
than six (6) inches by eight (8) inches placed on edge for
spans not more than eight (8) feet."
Section 30. That the second un-numbered paragraph of Section 3206,
entitle~ Exceptions, is hereby amended to read as follows:
"Exceptions. Roofs of all buildings shall be so that they
will drain to gutters and downspouts, which shall carry the
water down from ~he roof to an effective dry well, or by
conductors under the sidewalk and through the curb gutter,
to protect the adjacent property from damage."
Section 31. ~l~at ~he first un-num0ered paragraph of Section 3302-b
of the 0nifor~ ~Bui.lding Code, 1955 Edition is hereby amended to read as
follows:
"Group D and Group H occupancies having an occupant loan of ~L. L.,~
more than lO shall have not less than two exits. Other
occupancies having an occupant load of more than 50 shall
have not less than two exits."
Section 32. That Section 3702 (a) of the Uniform Building Code, 1955
Editio~,'i~ hereb~ amended by adding thereto Section 3702-(a-1) to read
as follows:
"Section 3702-(a-1) Every chimney shall be wholly supported on
an approved masonry or non-combustible foundation. Each
chimney shall have a clean-out conveniently located."
Section. 33. That Section 3802 of the Uniform Building Code, 19S5
EditiOn~'' is h~eby amended by adding thereto the following paragraphs,
to read as follows:
"Required automatic fire-extinguishing system sh~ll comply
in all respects with ~he regulations set forth in U.B.C.
Standards No. 38-1, 38-2 and Pamphlet No. 13 of National
Board of Fire Underwriters."
~'Sprinklers ReQuired: Inbuildings erected or altered to
increase the'area'o~ height, appro~d automatic sprinkler
systems shall be installed and maintained in accordance with
the following paragraphs. The areas referred to shall 0e the
area enclosed hy exterior walls or fire walls or a combination
thereof, except that in buildings of fire resistance construc-
tion the area shall ~e ~hat enclosed by exterior walls, fire
walls or walls of non-combustible material having a fire
resistance rating of not less than 2 hours, or a combination
thereof. Combustible tools or merchandise shall include those
made of wood, paper or rubber; thoze containing flammable
liqui~ds; those packed with excelsior, moss or paper; and
other goods or merchandise of equivalent or greater combusti-
bility.
(a) Buildings over ~ stories in height used for the manu-
facture, sales, or storage of combustible goods, merchandise
{not including garages) and exoeeding in area 8,000 square
feet when of ~ype II construction.
(b) Buildings over ~ stories in height used for the manu-
facture, sales or storage of combustible goods or merchandise
(not including garages) and exceeding in area 10,000 square
feet when of fire resistive construction or Type I.
Ordinance No. 2173 (Con't)
(c) Buildings over 2 stories in height used for the manu-
facture, sales, or storage of comOustible goods or merc~ancise
(not including garages) and exceeding in area 6,000 square
feet of constnuction, or Type III or Type V construction.
(d) Buildings over 50 feet in height used for storage of
combustible goods or merchandise ~no'~ including garages),
regardless of area, where of Type I construction or of Type
II construction.
(e) Buildings over 35 feet in height used for storage of
combustible goods or merchandise (not including garages),
regardless of area, when of Type III H.T., of Type III one-
hour construction or of Type IV unprotected construction.
(f) Buildings exceeding 2 stories in height or in excess
of 2,000 square feet in area on any floor above the first or
ground floor, which do not have suitable access, as defined in
this paragraph, to each story above the basement on at least
one-accessible side of She Building. Suitable access shall
be deemed as requiring an opening for fire department use
through the wall at each story at least 32 inches wide, 48
inches high and with the sill not more than 32 inches above
the floor; ~he openings shall oe so spaced that there will be
one opening above the floor; the openings shall Oe so spaced
tha~ there will be one opening in each 50 feet of exterior
wall on an accessible side of ~he building.
(g) Enclosed parking garages over 65 feet in height and
exceeding in area lO,O00 square fe.~t if of Type I fire resis-
tive construction or 8,000 square feet if of Type II construc-
tion or 6,000 squa~e fet if of Type III H.T. or one hour
construction.
(h) Open air parking garages over 6~ feet in height and
exceeding 15,000 square feet in area.
(i) Repair Garages~:
(1) Repair garages over one story in height or
located below another occupancy, exceeding lO,O00
square feet in area. ~hen of Type I construction,
8,000 square feet in area when of Type II construc-
tion, or 6,000 square feet in area when of Type III
of ~V or V construction.
(2) One-story repair garages exceeding 15,000 square
feet in area when of Type I construction, 12,000 square
feet in area when of Type II construction, 9,000 square
feet in area when of Type III or IV construction, or
6,000 square feet in area when of Type V construction.
(j) Basement having an area exceeding 2,500 square feet,
when used for the manufacture, sales or storage of combustible
goods or merchandise, (not including garages). In 'buildings
used for assembly, education, insiitutional or residential
occupancies, the automatic spri, nkler system shall be required
only in such portions oI' the basement as are used for storage
purposes or work shops.
(k) Basement garages below other occupancies and exceeding
5,000 square feet.
(1) In places of assembly having a stage complying with
~hapter 600 and 3900 at all locations on the stage side of the
proscenium opening such as under the roof of the stage, under
the gridiron the rigging loft and fly and tie galleries, under
the s~age, ~n?.dreasing ~ooms, scene docks, work shops and stor-
age rooms.
Section= 34. That Section 4402 of the Uniform Building Code, 1955
Edition, is hereby amended by adding thereto Section 4402-e to read as
follows:
"Section 4402-e. In front of a building for which a permit
was issued the amount of sidewalk, road-way or public pro-
perty that may be used in connection with any construction
work, shall ~ determined by the Building Inspector with the
Ordinance No. 2173 (Con't)
approval of the City Engineer, and the Chief Traffic Officer
A plan must be submitted and approved, detailing the amount
of street and sidewalk to be used; on the walkway and canopy,
lights must be installed to give a clear vision; of the length
of the walk, detailing the type of protection to be installed
and have the same approved."
Section 3§, That Chapter 51, Heat-Producing Appliances of the
appendix of the Uniform Building ~ode, 1955 Edition, is hereby adopted
by reference thereto as a part of the Building Code of the City of
Bremerton and by this reference made a part of this Ordinance.
APPROVED on first reading this 23rd day of May, 1956.
PASSED AND APPROVED by the City Council of the City of Bremerton,
signed by the Mayor and attested by the City Clerk in authentication
of such passage this 6th day of June, 1956.
ATTEST: H.O. DOM'S-TA1)' -M~f~'o~ ~
E.H.T. McGOWAN, ~City Clerk