AN ORDINANCE adopting the Washington State Building Code Act,
RCW 19.27, providing for building and fire safety within the
City limits of the City of Bremerton and repealing Ordinances
#3427, 2815, 1417, 3755, 3582, 3548, 2824, 2428, 2106, 2041,
1221, 1119, 3439, 3675, 3605, 3401, 3394, 3678, 3639, 3428,
2802, 2479, 3498, 3730, 3617, 3607, 3112, 2270, 2213, 2170,
2168, 2162, 3277, 2149 and 3966.
This Ordinance is entitled "Building and Fire Safety Code."
SECTION 1: This section provides for the title of this
Ordinance.
SECTION 2: This section provides for the repeal of existing
Building Exit Code, Uniform Building Code, Fire Zones provisions,
Building Inspector provisions, Dangerous Buildings Code, Plumbing
Code, Swimming Pool Code, Fire Code and Fire Prevention Codes,
Life Safety Code, Mechanical Code, Gas Fitters and Mechanical
Installers License, Sign Code, Billboards provisions, and the
Building and Fire Safety Code.
SECTION 3: This section sets forth the purpose of the City
of Bremerton Building and Fire Safety Code to enhance the health,
safety and welfare of the public as a whole.
SECTION 4: This section adopts by reference the following
codes and regulations, subject to the modifications and/or
amendments set forth in Sections 8, 9 and 10:
a. Uniform Administrative Code, except Table 3B.
b. Uniform Building Code and Uniform Building Code
Standards, with appendices in Chapters 1,
SS and ?0; provided Sections 45OS(e) and 4SO6(b) are not adopted.
c. Uniform Mechanical Code. with Chapter 22 and
appendices A, B and C.
d. Uniform Fire Code and Uniform Fire Code Standards,
with appendices IA, lB, IIB, IIC, IliA, IIIB, IVA, VA. and VIA.
e. Uniform Plumbing Code and Standards, with
appendices A, B. C, D. G. and H; provided Chapter 11 is not
adopted.
f. Uniform Sign Code.
g. Uniform Code for the Abatement of Dangerous
Buildings.
h. Regulation for Barrier-Free Facilities, adopted
pursuant to RCW 70.92.100; and
i. Washington State Energy Code, WAC 51-12.
SECTION 5: This section provides for conflicts among the
codes and which shall govern.
SECTION 6: This section provides various abbreviations for
this Ordinance.
SECTION 7: This section provides that the Building Official
is charged with the administration and enforcement of this
Ordinance, except that the Fire Chief shall enforce Section 4d
(U.F.C.).
SECTION 8: This section provides for amendments to the
Uniform Building Code, Sections 108; 109; 110; 111; 112; 113;
114; 115; 116; 301; 304; 305; 2516; 3802; 5401; 5406; Part I,
Chapter 3; Part IV, Chapter 25; Part ×, Chapter 38 and Chapter
54; and Appendix Chapter
SECTION 9: This section provides for amendments to the
Uniform Fire Code, Appendix Division IA.
SECTION 10: This section provides for amendments to the
Uniform Plumbing Code, Sections 20.6; 20.7; and 20.9.
SECTION 11: This section provides for amendments to the
Uniform Sign Code, Chapter 2, Section 203; and Chapter 15,
Sections 1501, 1502, 1503, 1504, 1505, 1506, 1507. 1508, 1601.
1602, 1603, and 1604.
SECTION 12: (a) This section provides the definition of
"mobile home."
(b) This section provides for the exclusion of mobile
homes from the provisions of the Uniform Building Code, Uniform
Mechanical Code, Uniform Plumbing Code (but only as such applies
to internal plumbing) and Regulations for Barrier-Free Facilities
as provided by RCW 19.27.060(3).
(c) This section provides for the obtaining of a permit
before the placing or location of any mobile home on a lot or
parcel and provides the fee therefor.
(d) This section provides for the issuance of a permit
if the mobile home conforms to the requirements of the City of
Bremerton Zoning Ordinance and the mobile home installation
requirements of WAC 296-150B.
SECTION 13: (a) This section provides the definition of
"factory-built housing."
(b) This section provides for the exclusion of
factory-built housing from the provisions of the Uniform Building
Code, Uniform Mechanical Code, Uniform Plumbing Code (but only as
such applies to internal plumbing) and Regulations for Barrier-
Free Facilities.
(c) This section provides that each unit of factory-
built housing shall have a permanent foundation and provides for
the submission of plans, permit fees, zoning ordinance
requirements, and proper construction review.
SECTION 14: This section provides for amendments to the
Dangerous Building Code Sections 401-404, 701, 702, 703, 909-911,
and 912.
SECTION 15: This section provides that if any section,
subsection, sentence, clause, or phase of the City of Bremerton
Building and Fire Safety Code is found to be invalid, the
remainder thereof shall not be affected.
SECTION 16: Penalties - Unless otherwise more specifically
provided, any person, firm, or corporation violating any of the
provisions of the City of Bremerton Building and Fire Safety Code
shall be deemed guilty of a misdemeanor, and each such person,
firm, or corporation shall be deemed guilty of a separate offense
for each and every day or portion thereof during which any
violation of any of the provisions of the City of Bremerton
Building and Fire Safety Code is committed, continued or
permitted, and upon conviction of any such violation such person,
firm, or corporation shall be punished by a fine of not more than
One Thousand Dollars ($1,000.00) or by imprisonment for not more
than ninety (90) days, or by both such fine and imprisonment for
each violation.
Any person desiring the full text of the foregoing Ordinance
may so request from the City Clerk and it shall be provided
~ithout charge.
Approved by the City Council on the first reading on
day of ~/~_f.~ ..... , 1986.
Passed by the City Council of the City of Bremerton, signed
by the Mayor and attested to by the City Clerk in authentication
of such passage on _~__~z~ day of ~_~_z/z~/Z, , 1986.
GENE L~E, Mayor
City of Bremerton
ATrE~:
KATI~J~ L. IVI~CLUSKEY, City Clerk
Director of A(tninistrative Services
AN ORDINANCE adopting the Washington State Building Code Act,
RCW 19.27, providing for building and fire safety within the
City limits of the City of Bremerton and repealing Ordinances
#3427, 2815, 1417, 3755, 3582, 3548, 2824, 2428, 2106, 2041,
1221, 1119, 3439, 3675, 3605, 3401, 3394, 3678, 3639, 3428,
2802, 2479, 3498, 3730, 3617, 3607, 3112, 2270, 2213, 2170,
2168, 2162, 3277, 2149 and 3966.
WHEREAS, Ordinance 3966 was adopted to ensure that the
City of Bremerton administer and enforce The State Building Code
Act (RCW 19.27) within the city limits.
WHEREAS, Ordinance 3966 contained desirable
modification's and/or amendments to the State Building Code Act.
WHEREAS, additional modifications and/or amendments are
necessary to insure that the City has a lien on property
whenever they have a dangerous condition, to adopt the 1985
Edition of the Uniform Administrative Code, and to designate the
BuilGing Official as the enforcement officer of Appendix 70 of
the Uniform Building Code and to increase the penalties for a
violation of the Ordinance.
THE CITY OF BREMERTON DOES HEREBY ORDAIN:
~~_l~_~Iam~.
This ordinance shall be known as the City of Bremerton
Building and Fire Safety Code.
fu~C~_~_~9~e_~ of ordinance 93427, 2815, 1417 (Building Exit
Code, B.M.C. 17.06); ordinance #3755, 3582, 3548 (Uniform
Building Code, B.M.C. 17.04); ordinance #2824, 2428, 2106, 2041,
1972 (Fire Zones, B.M.C. 17.08); ordinance 1221, 1119 (Building
Inspector B.M.C. 17.12); ordinance #3439 (Dangerous Buildings
Code, B.M.C. 17.20); ordinance ~3675, 3605, 3401 (Plumbing Code
B.M.C. 17.28); ordinance 3394 (Swimming Pool Code, B.M.C. 17.52);
ordinance #3678, 3639, 3428, 2802, 2479 (Fire Code and Fire
Prevention Codes, B.M.C. 18.04); ordinance #3498 (Life Safety
Code, B.M.C. 18.16); ordinance #3730, 3617, 3607 (Mechanical
Code, Gas Fitters and Mechanical Installers License B.M.C.
-- 1 --
17.48); ordinance #3112, 3071, 2270, 2213, 2170, 2168, 2162 (Sign
Code, B.M.C. 17.44); and ordinance #3277, 2149 (Billboards,
B.M.C. 17.46); and ordinance 3966 (Building and Fire Safety
Code).
The purpose of the City of Bremerton Building and Fire
Safety Code is to enhance the health, safety and welfare of the
public as a whole by ensuring that buildings, dwellings,
structures, and land will be constructed, maintained and/or used
in a manner so as to reduce hazards, increase durability and
require consistent patterns of Community Development; ~_iQY_i~,
notwithstanding anything in this ordinance or in the codes
adopted in Section 4 to the contrary, this ordinance and the
codes adopted in Section 4 establish duties owed to the public as
a whole and not any duties to protect any person or class of
persons.
~iT~Q~_&~_A~9~ign_~_~9£~re~es.
The following codes and regulations are hereby adopted by
reference subject to the modifications and/or amendments set
forth in Sections 8, 9, 10:
a. International Conference of Building Officials,
Uniform Administrative Code (1985 ed.)
Except: Table 3 B
b. International Conference of Building Officials,
Unifor~__~il~_i~!!~__~D~d~ and
~]~q/l~a, (1985 ed.) together with those appendices
in Chapters 1, 7, 11, 32, 35, 38, 49, 55 and 70;
provided Section 4505 (e) and Section 4506 (b) are
not adopted.
c. International Association of Plumbing and Mechanical
Officials and International Conference of Building
Officials, ~i~i~r3~k___M~_h_a_n_i_c~____C~ (1985 ed.)
together with Chapter 22 and Appendices A, B and C.
- 2 -
d. Western Fire Chiefs Association and International
Conference of Building Officials, ~niform Fire
~D~d_i!D~9~m__~__~Q_0_~_~Bda~d (1985 ed.) together
with Appendices I A, I B, II B, II C, III A, III B,
IV A, V A, and VI A;
e. International Association of Plumbing and Mechanical
Officials and International Conference of Building
Officials, ~/D~l~__~u_m_~b'n_g__C~td_~d_~ndard~ (1985
ed.) together with Appendices A, B, C, D, G, and H
~9¥~d~d, Chapter 11 is not adopted.
International Conference of Building Officials,
~ai~_~SD_~od~ (1985 ed.).
g. International Conference of Building Officials,
(1985 ed.);
h. Washington State Building Code Advisory Councils,
R_9_~iga__~or __~aX~i~_~c_~; adopted
pursuant to R.C.W. 70.92.100 and
i. Washington State Building Code Advisory Councils,
current ~IDJ~i~~_~_~[~Y Code (current
edition), WAC 51-12.
~~_~~s_Among CoOe s.
In cases of conflict among the codes adopted in Section 4
A-I, the Code first named shall govern in descending listing.
a. International Conference of Building Officials,
~niform Buildin~_Qode (1985 ed.) shall be known as
Uniform Building Code or UBC.
b. International Conference of Building Officials,
Uniform Adminis~ratioB_Code (1985 ed.) shall be known
as the Uniform Administrative Code or the UAC.
c. International Association of Plumbing and Mechanical
o~ficials and International Conference of Building
Officials, in~_~__M_e_c_ka_~ical ~ode (1985 ed.) shall
be known as the Uniform Mechanical Code of UMC.
-- 3 --
d. Western Fire Chiefs Association and International
Conference of Building Officials,
(1985 ed.) shall be known as Uniform Fire Code or
UFC.
e. International Association of Plumbing and Mechanical
Officials and International Conference of Building
Officials, ~nif~m P u~i~t_~9_~d (1985 ed.) shall be
known as Uniform Plumbing Code of UPC.
f. International Conference of Building Officials,
(1985 ed.) shall be known as the Dangerous Buildings
Code or DBC.
g. International Conference of Building Officials,
~niform_~_QO_~ (1985 ed.) shall be known as the
Uniform Sign Code or USC.
The Building Official is charged with the administration
and enforcement of the City of Bremerton Building and Fire Safety
Code, except that the Fire Chief shall enforce Section 4d (U.F.C)
above with associated amendments in Section 9 below. To this end
he/she may retain necessary personnel, conduct inspections and
investigations, issue appropriate permits, maintain necessary
records and files, and do, or cause to be done, all things
necessary and proper for the administration and enforcement of
the City of Bremerton Building and Fire Safety Code. Appendix 70
of the UBC shall be enforced by the Building Official.
~ECT~Q~ 8._~Bl~p_~_~_~gilding C9~9_m_~D~dmeDts.
a. Permit exemption for repair amendments. UBC, Section
301 (a), is hereby amended to read as
follows:
Section. 301 (a) Permits Required. It shall be
unlawful for any person, firm or corporation to
erect, construct, enlarge, alter, repair, move,
improve, remove, convert or demolish any building or
- 4 -
structure regulated by this code, except as specified
in subsection (b) of this section or causes same to
be done without first obtaining a separate permit for
each building or structure from the Building
Of f i c i al:
b. Deletion of exceptions. UBC, Section 301 (b) (1) (2)
are hereby deleted.
c. Addition to an exemption. UBC, Section 301 (b)(8) is
amended to read as follows; painting, papering and
similar finish work a[~___instal ]at~ on _~_~
a~ pa d,
d. Fee Schedule ~endment. Section 304 ~))is hereby
amended to read as follows: Plan Review Fees. When
a plan or other data is required to be submitted by
Section (b) of Section 302, a Plan Review Fee shall
be paid at the time of submitting plans and
specifications for review. Said Plan Review Fee
shall be 65% of the building permit fee as shown in
table No. 3-A; ~~,
~~~~h~n~nd~m~. Where plans are
incomplete or changed so as to require additional
plan review, an additional Plan Review Fee shall be
charged at the rate shown in table No. 3-A.
e. Deleation of under-floor inspection. Section 305 (e)
(2) is hereby modified to read. CONCRETE SLAB
Inspection: to be made after all in-slab building
service equipment, conduit, piping accessories and
other ancillary equipment items are in place but
before any concrete is poured.
-- 5 --
f. Amendments regarding foundation ventilation for
certain occupancies.
(1) UBC, Section 2516 c (6) shall have no
application to group R and M occupancies.
(2) UBC Section 2516 (c) is amended to add a new
sub-section (12) which shall be as follows:
(12) TJie__i~/~__"~]~_cb__Q~_~hall_/ltaN_e__~ ne t
~DA__of~_ no]~_~e_s s__th_an_l_s ~._fL~-_~r__~a_c~_!5_Q_ ~q,
ft._Df_ unde]L~lo o r_-ar_~a '_'_i~_ to_b_~_revised_t~ read
a s_/n~~_ _i31 _t h 9_ ~_933_~_udg__tJaa[_v~n til aJLtgn
ia_ Io_ hg_Dla_ced_/s_ oDDo_sln_~_ N alla_t o_all_o~__c& o s s
ventllaIion .... ~n_~! ..... _S/l~__ ___r e_~_d, aa
fo~ oN s: __F~kgnd at~_gD_¥e n_til a_tign_~9 r _G~_oup_ R and
ymn! il_at e_d_kY__an_a~Dr~v ed_m9 chani~al_.m~am_s_mx by
mme_ninSm__s, ho1.L_h~_v.9__a__n_e_t__a_r._e_a__~_f.__ne t_l e a_s_~ h an
6D__a_%uar._e.__/n~ke.~__f~__~c~_i2~ia~_~e~ of
cl_o~els_to_ ~.]~_e_cn r_ne rs_as_i_s_~rom~ica~__an~_.~hal~
~ o~ c r__wi~h_ _cm~j_o_simm_ _ r e_s i~ t a_n t __re=ak_ no t_._L~_~
Ih_at__lY4"__a_n~d__m_ot
di~~n.
g. This section provides amendments to Part I, Chapter
3; Part IV, Chapter 25; Part X, Chapter 38 and
Chapter 54; and Appendix Chapter I of the Uniform
Building Code. The amendments to Part I, Part IV and
part X include deleting permit requirements of
Section 301 (a) for buildings within group R-3 and
group M occupancies where repair costs are less thaan
$200.00; deleting exceptions contained in Section 301
(b) (1) (2); broadening a permit exemption contained
in Section 301 (b) (8) to include installation of
floor covering material; consol idating the plan
- 6 -
review fee of Section 304 (b) when an individual
submits plans for two or more identical buildingsss
of group R-3 or group M occupancies; deleting the
requirement of Section 305 (e) for an underfloor
inspection; exempting group R and M occupanciess
from the foundation ventilation requirements of
Section 2516 (c) (6) and instead requiring group R
and M occupancies to comply with the 1979 foundation
ventilation reqirements; amending sprinkler system
requirements in Chapter 38 requiring that group R
occupanciesss be subject to Chapter 54, except that
for R-3 occupancies glazing located more than
ei§hteen inches (18") above the surface used as a
walking surface, glazing which is no greater than
eighteen inches (18") in any dimension and glazing
protected by a guardrail, handrail, or other approved
barrier are not considred hazardous locations under
Section 5406 (d).
The amendments to Appendix Chapter 1 entitled "Life
Safety Requirements for existing Buildings" include
redefining and renumbering the stated purpose of
Section 108 (a) to be to protect the general public
as a whole and amending and renumbering Section 108
(b) to allow an owner eighteen (18) months after
notice of non-compliance with the Apendix to submit
plans for compliance and another eighteen (18) months
to bring the building into conformance with the
Appendix; provided, however, that this lenient time
compliance requirements does not apply if the
existing building is otherwise declared to be
dangerous under the Uniform Code for the Abatement of
Dangerous Buildings. A new subsection states that
the owner of a building remains liable for code
violations, even though an obligation is imposed on
occupants of the building and even though the owner
has, by agreement, imposed on the occupant the duty
- 7 -
of furnishing required equipment to comply with this
code. Every owner, or his agent, is also responsible
for keepin9 that part of the building or premises
which he occupies or controls in a clean, sanitary
and safe condition, including the shared or public
areas in a buildin9 containing two (2) or more
dwelling units. This "responsibility" subsection
further imposes on an owner the duty to furnish
required and approved sanitary facilities and
facilities for the prevention and extermination of
insect and rodent infestation. The occupany of a
dwelling unit is responsible for keeping in a clean,
sanitary and safe condition that part of the dwelling
or premises which he ocupies and this includes
properly disposing of his rubbish, garbage or other
organic waste and maintaining where required by the
health ordinance or the health officer approved
devices, equipment or facilities. A new subsection
is added designating substandard buildings as a
public nuisances and requiring abatement under the
procedures of Section 203 (b) of the Uniform Building
Code using the more lenient compliance time
requirements of Appendices Chaper 1, unless the
condition also constitutes a dangerous building, in
which case compliance time requirements as set forth
in the Uniform Code for the Abatement of Dangerous
Buildings must be followed. A new section is added
defining a nuisance as a public nuisance known as
common law or in equity jurisprudence as an
attractive nuisance, overcrowding, insufficient
ventilation or illumination, inadeuate or unsanitary
sewage or plumbing facilities, uncleanliness and
conditions which render air, food or drink
unwholesome or detrimental to human health. The exit
requirements contained in Section 109 (b) are
renumbered and the requirement that exterior stairs
- 8 -
be of non-combustible construction is deleted. A new
subsection is added to the exit requirements as the
appendices, which requires that every dwelling unit
or guestroom shall have access directly to the
outside or to a public corridor; all buildings or
portions therof shall be provided for exits, exit
ways and appurtenances as required by Chapter 38 of
the Uniform Building Code. A new section is added
defining substandard buildings to include public
nuisances defined above, buildings with inadequate
exits, inadequate fire protections or fire fighting
equipment, and improper occupancy.
h. Amendments regarding automatic fire extinguishing
systems.
(1) UBC Section 3802 is hereby amended as follows:
(C) Group A occupancy
1. Nightclubs, discos, an automatic sprinkler
system shall be installed in rooms primarily
usesd for extertaining occupants who are
drinking or dining where the total area
exceeds 5,000 square feet, and all
unseparated accessory uses where the total
area exceeds 10,000 square feet. For uses
to be considered as separate, the separation
shall not be less than required for a one
hour occupancy separation.
2. An automatic sprinkler system shall be
installed in all basements classified as
Group A Occupancy.
3. Exhibition and Display rooms. An automatic
sprinkler system shall be installed in Group
A Occupancies which have more than 10,000
square feet of floor area.
(2) UBC Section 3802 (d) is hereby amended as
follows:
- 9 -
(d) Group B, Division 2 Occupancies. An
automatic sprinkler system shall be
installed in all areas classed as Group B,
Division 2 Occupancies where the total floor
area is 10,000 square feet or more.
(3) UBC Section 3802 (e) is hereby amended as
follows:
(e) Group E Occupancciies. An automatic
sprinkler system shall be installed in all
Group E Occupancies of 10,000 or more square
feet.
(4) UBC Section 3802 (f) Sub-section 4 is amended as
follows:
(f) H. Group H, Division 4. An automatic fire
extinguishing systems shall be installed in
all Group H, Division 4 Occupancies more
than one story in height or 10,000 or more
square feet in area.
(5) There is hereby added to UBC Section 3802 (f) a
new subsection 5, which shall be as follows:
(5) Group H, Division 5. An automatic fire
extinguishing sydstem shall be installed in
all Group H, Division 5 Occupancies of
10,000 or more square feet in area.
(6) There is hereby added to UBC Section 3802, a new
subsection (g) which shall be as follows:
3802 (g) Group R, Division 1 Occupancies. An
automatic sprinkler system shall be installed in
Group R, Division 1 Occupancies of 10,000 or
more square feet or having five or more dwelling
units.
g. Amendment regarding glass and glazing.
(1) UBC, Section 5401 (a)1 is hereby amended to read
as follows:
(a) Exterior glass and glazing in all
occupancies except Group M not over three
stories in height; and,
- 10 -
(2) UBC Section 5406 (d) is amended to add a new
subsection 7 which shall read as follows:
7. Subsection (d) hereof shall have no
application to R-3 occupancies in the following
situations:
(a) For glazing located more than eighteen (18)
inches above the surface normally used as a
walking surface;
(b) For glazing which is no greater that
eighteen (18) inches in any dimension; and
(c) For glazing protected Dy a guardrail,
handrail or other approved barrier.
i. Appendix Chapter 1 is amended to read as follows:
GENERAL
Section 107.
(a) Purpose. The purpose of this chapter is to
enhance the health, safety and welfare of the
general public by providing for alterations to
certain such existing buildings which do not
meet the minimum requirements of the Code.
EXCEPTION: Group R, Division 3 or Group M
Occupancies.
(b) Effective Date. Within 18 months after notice
to the owner of a violation of this appendix,
plans for compliance shall be submitted and
approved, and within 18 months thereafter, the
work shall be completed or the building shall be
vacated until made to conform, provided that if
the Building Official declares that conditions
in violation of this appendix also constitute a
dangerous building under Section 302 of the
Dangerous Building Code or Section 203 of the
UBC, the Building Official shall determine the
time compliance requirements in accordance with
Section 401 of the uniform code for the
Abatement of Dangerous Buildings.
- 11 -
(c) Alternate Materials and Methods. Alternate
materials and methods may be used, provided such
materials or methods comply with the spirit and
intent of this appendix.
The Building Official may modify any of the
provisions of this appendix in conformance with
Section 106 of this code.
(d) Responsibilities Defined. Every owner remains
liable for violations of duties imposed upon him
by this code even through an obligation is also
imposed on the occupants of his building, and
even though the owner has, by agreement, imposed
on the occupant the duty of furnishing required
equipment to comply with this code.
Every owner, or his agent, in addition to being
responsible for maintaining his building in a
sound structural condition, shall be responsible
for keeping that part of the building or
premises which he occupies or controls in a
clean, sanitary and safe condition, including
the shared or public areas in a building
containing two or more dwelling units.
Every owner shall, where required by this code,
the health ordinance or the health officer,
furnish and maintain such approved sanitary
facilities as required, and shall furnish and
maintain approved devices, equipment or
facilities for the prevention of insect and
rodent infestation, and where infestation has
taken place, shall be responsible for the
extermination of any insects, rodents or other
pests when such extermination is not
specifically made the responsibility of the
occupant by law or ruling.
Every occupant of a dwelling unit, in addition
to being responsible for keeping in a clean,
- 12 -
sanitary and safe condition that part of the
dwelling or dwelling unit or premises which he
occupies and controls, shall dispose of all his
rubbish, garbage and other organic waste in a
manner required by the health ordinance and
approved by the Health Officer.
Every occupant shall, where required by this
code, the health ordinance or the health
officer, furnish and maintain approved devices,
equipment or facilities necessary to keep his
premises safe and sanitary.
(e) Substandard Buildings. Ail buildings or
portions thereof which are determined to be
substandard as defined in Section 116 of this
Appendix are hereby declared to be public
nuisances and shall be abated by repair,
rehabilitation, demolition or removal in
accordance with the procedure specified in
Section 401 of the Dangerous Building Code;
provided however that the time compliance
requirements of Section 107(b) of the Appendix
will apply if the condition(s) are determined by
the Building Official to be substandard and not
rise to the level of a dangerous building
defined in Section 301 of the Dangerous Building
Code or Section 203 of UBC.
DEFINITIONS
Section 108 Nuisance.
The following shall be defined as nuisances:
1. Any public nuisance known at common law or in
equity jurisprudence.
2. Any attractive nuisance which may prove
detrimental to children whether in a building, on
the premises of a building, or upon an unoccupied
lot. This includes an~~ abandoned wells, shafts,
- 13 -
~asements or excavations; amandoned refrigerators
and motor vehicles; or any structurally unsound
fences or structures; or any lumber, trash,
fences, debris or vegetation which may prove a
hazard for inquisitive minors.
3. Whatever is dangerous to human life or is
detrimental to health, as determined by the
health officer.
4. Overcrowding a room with occupants.
5. Insufficient ventilation or illumination.
6. Inadequate or unsanitary sewage or plumbing
facilities.
7. Uncleanliness, as determined by the health
officer.
8. Whatever renders air, food or drink unwholesome
or detrimental to the health of human beings, as
determined by the Health Officer.
EXITS
Section 109.
(a) Number of Exits. Every floor above the first
story used for human occupancy shall have access
to at least two separate exits, one of which may
be an exterior fire escape complying with
Subsection (d) of this section. Subject to the
approval of the Building Official, an approved
ladder devise may be used in lieu of a fire
escape when the construction feature or location
of the building on the property make the
installation of a fire escape impracticable.
EXCEPTION: In all occupancies, second stories
with an occupancy load of 10 or less may have
one exit.
An exit ladder device when used in lieu of a
fire escape shall conform with U.B.C. Standard
No. 33-3 and the following:
- 14 -
Serves an occupant lo~~ of 10 or less or a
single dwelling unit or guest room.
2. The building does not exceed three stories
in height.
3. The access is adjacent to an opening as
specified for emergency egress or rescue or
from a balcony.
4. Shall not pass in front of any building
opening below the unit being served.
5. The availability of activating the device
for the ladder is accessible only from the
opening or balcony served.
6. So installed that it will not cause a person
using it to be within 6 ieet of exposed
electrical wiring.
(b) Stair Construction. All required stairs shall
have a minimum run of 9 inches and a maximum
rise of 8 inches and shall have a minimum width
of 30 inches exclusive of handrails. Every
stairway shall have at least one handrail. A
landing having a minimum 30-inch run in the
direction of travel shall be provided at each
point of access to the stairway.
EXCEPTION: Fire escapes as provided for in this
Section.
EXCEPTION: On building of Types III, IV and V,
provided the exterior stairs are constructed of
wood not less than 2-inch nominal thickness.
(c) Corridors. Corridors of Groups A, B, E, I, H
and R, Division 1 Occupancies serving as an exit
for an occupant load of 30 or more shall have
walls and ceilings of not less than one-hour
fire-resistive construction as required by this
code. Existing walls surfaced with wood lath
and plaster in good condition or 1/2 inch gypsum
wallboard or openings with fixed wired glass set
- 15 -
~.n steel frames are permit~-d for corridor walls
and ceilings and occupancy separations when
approved. Doors opening into such corridors
shall be protected by 20-minute fire assemblies
or solid wood doors not less than 1 3/4-inch-
thick. Where the existing frame will not
accommodate the 1 3/4-inch-thick door, a 1 3/8-
inch-thick solid bonded wood core door or
equivalent insulated steel door shall be
permitted. Doors shall be self-closing or
automatic-closing by smoke detection. Transoms
and openings other than doors from corridors to
rooms shall comply with Section 3305 (h) of this
code or shall be covered with a minimum of 3/4-
inch plywood or 1/2-inch gypsum wallboard or
equivalent material on the room side.
EXCEPTION: Existing corridor walls, ceilings
and opening protection not in compliance with
the above may be continued when such buildings
are protected with an approved automatic
sprinkler system throughout. Such sprinkler
system may be supplied from the domestic water
system if it is of adequate volume and pressure.
(a) Fire Escapes.
1. Existing fire escapes which in the opinion
of the Building Official comply with the
intent of this section may be used as one of
the required exits. The location and
anchorage of fire escapes shall be of
approved design and construction.
2. Fire escapes shall comply with the
following:
Access from a corridor shall not be through
an intervening room.
All openings within 10 feet shall be
protected by three-fourths-hour fire
- 16 -
assemblies. When located within a recess or
vestibule, adjacent enclosure walls shall be
of not less than one-hour-fire-resistive
construction.
Egress from the building shall be by a clear
opening having a minimum dimension of not
less than 29 inches. Such openings shall be
openable from the inside without the use of
a key or special knowledge or effort. The
sill of an opening giving access shall be
not more than 30 inches above the floor of
the building or balcony.
Fire escape stairways and balconies shall
support the dead load plus a live load of
not less than 100 pounds per square foot and
shall be provided with a top and
intermediate handrail on each side. The
pitch of the stairway shall not exceed 60
degrees with a minimum width of 18. inches.
Treads shall be not less than 4 inches in
width and the rise between treads shall not
exceed 10 inches. All stair and balcony
railings shall support a horizontal force of
not less that 50 pounds per lineal foot of
railing.
Balconies shall be not less that 44 inches
in width with no floor opening other than
the stairway opening greater that 5/8 inch
in width. Stairway openings in such
balconies shall be not less that 22 inches
by 44 inches. The balustrade of each
balcony shall be not less that 36 inches
high with not more than 9 inches between
balusters.
Fire escapes shall extend to the roof or
provide an approved gooseneck ladder between
- 17 -
the top floor landin~ and the roof when
serving buildings four or more stories in
height having roofs with less than 4:12
slope. Fire escape ladders shall be
designed and connected to the building to
withstand a horizontal force of 100 pounds
per lineal foot; each rung shall support a
concentrated loan o£ 500 pounds placed
anywhere on the rung. All ladders shall be
at least 15 inches wide, located with 12
inches of the building and shall be placed
flatwise relative to the face of the
building. Ladder rungs shall be 3/4 inch in
~iameter and shall be located 12 inches on
center. Openings for roof access ladders
through cornices and similar projections
shall have minimum dimensions of 30 inches
by 33 inches.
The lowest balcony shall be not more that 18
feet from the ground. Fire escapes shall
extend to the ground or be provided with
counterbalanced stairs reaching to the
ground.
Fire escapes shall not take the place of
stairways required by the codes under which
the building was constructed.
Fire escapes shall be kept clear and
unobstructed at all times and maintained in
good working order.
(e) Exit and Fire Escape Signs. Exit signs shall be
provided as required by this code.
EXCEPTION: The use of existing exit signs may
be continued when approved by the building
official.
All doors or windows providing access to a fire
escape shall be provided with fire escape signs.
- 18-
(f) Exits. Every dwelling unit or guest room shall
have access directly to the outside or to a
public corridor. All buildings or portions
thereof shall be provided with exits, exitways
and appurtenances as required by Chapter 33 of
the Building Code.
Every sleeping room below the fourth story shall
have at least one operable window or exterior
door approved for emergency escape or rescue.
The units shall be operable from the inside to
provide a full clear opening without the use of
separate tools.
All escape or rescue windows from sleeping rooms
shall have a minimum net clear opening of 5.7
square feet. The minimum net clear opening
height dimension shall be 24 inches. The
minimum net clear opening width dimension shall
be 20 inches. Where windows are provided as a
means of egress or rescue they shall have a
finished sill height not more than 44 inches
above the floor.
ENCLOSURE OF VERTICAL SHAFTS
Section 110.
Interior vertical shafts, including but not limited
to stairways, elevator hoistways, service and utility
shafts, shall be enclosed by a minimum of one-hour
fire-resistive construction. All openings into such
shafts shall be protected with one-hour fire
assemblies which shall be maintained self closing or
be automatic closing by smoke detection. All other
openings shall be fire protected in an approved
manner. (Existing fusible link-type automatic door
closing devices may be permitted if the fusible link
rating does not exceed 135 Degree F.).
- 19 -
EXCEPTIONS:
1. ~n other than Group 10ccuFancies, an enclosure
will not be required for openings servin9 only
one adjacent floor.
2. Stairways need not be enclosed in a continuous
vertical shaft if each story is separated from
other stories by one-hour fire-resistive
construction or approved wired glass set in steel
frames. In addition, all exit corridors shall be
sprinklered and the openings between the corridor
and occupant space have at least one sprinkler
head above the openings on the tenant side. The
sprinkler system may be supplied from the
domestic water supply if of adequate volume and
pressure.
3. Vertical openings need not be protected if the
building is protected by an approved automatic
sprinkler system.
FIRE PROTECTION
Section 111.
Ail buildings or portions thereof shall be provided
with the degree of fire-resistive construction as
required by the Building and Fire Safety Code for the
appropriate occupancy, type of construction and
location on property; and shall be provided with the
appropriate fire-extinguishing systems or equipment
required by Chapter 38 of the Uniform Building Code.
BASEMENT ACCESS OR SPRINKLER PROTECTION
Section 112.
An approved automatic sprinkler system shall be
provided in basements or stories exceeding 1500
square feet in area and not having a minimum of 20
square feet of opening entirely above the adjoining
ground level in each 50 lineal feet or fraction there
- 20 -
of exterior wall on at least one side of the
building. Openings shall have a minimum clear
dimension of 30 inches. Exception: Group R,
Division 3, Occupancies.
If any portion of a basement is located more that 75
feet from required openings, the basement shall be
provided with an approved automatic sprinkler system
throughout. Sprinkler system must meet the approval
of fire chief or building official in those
structures as required above.
STANDPIPES
Section 113.
Any buildings over four stories in height shall be
provided with an approved Class I or Class III
standpipe system.
SMOKE DETECTORS
Section 114.
Every dwellin§ unit and every guest room in a hotel
or lodging house used for sleeping purposes shall be
provided with smoke detectors installed in accordance
with this code.
SEPARATION OF OCCUPANCIES
Section 115.
Occupancy separations shall be provided as specified
in Section 503 of this code. When approved by the
building official, existing wood lath and plaster in
good condition or 1/2-inch gymsum wallboard may be
acceptable where one-hour occupancy separations are
required.
SUBSTANDARD BUILDINGS
DEFINITION
Section 116.
- 21 -
(a) General. Any building or portion thereof,
including any dwelling unit, guest room or suite
of rooms, or the premises on which the same is
located, in which there exists any of the
followin~ listed conditions to an extent that
endangers the life, limb, health, property,
safety or welfare of the public or the occupants
thereof shall be deemed and hereby is declared
to be a substandard building.
(b) Nuisance. Any nuisance as defined in this code.
(c) Inadequate Exits. All buildings or portions
thereof not provided with adequate exit
facilities as required by this code except those
buildings or portions thereof whose exit
facilities conformed with all applicable laws at
the time of their construction and which have
been adequately maintained and increased in
relation to any increase in occupant loan,
alteration or addition, or any change in
occupancy.
When an unsafe condition exists through lack of,
or improper location of exits, additional exits
may be required to be installed.
(d) Inadequate Fire-protection or Fire-fighting
Equipment. All buildings or portions thereof
which are not provided with the fire-resistive
construction, fire-extinguishing systems, or
early warning equipment required by this code,
except those buildings or portions thereof which
conformed with all applicable laws at the time
of their construction and whose fire-resistive
integrity and fire-extinguishing systems or
early warning equipment have been adequately
maintained and improved in relation to any
increase in occupant load, alteration or
addition, or any change in occupancy.
- 22 -
(e) Improper Occupancy. Ail buildings or portions
thereof occupied for living, sleeping, cooking
or dining purposes which were not designed or
intended to be used for such occupancies.
a. Appendix Division I A to read as follows:
1. GENERAL
(a) Purpose. The purpose of this chapter is to
enhance the health, safety and welfare of
the general public by providing for
alterations to certain such existing
buildings which do not meet the minimum
requirements of the Code.
EXCEPTION: Group R, Division 3 or Group M
Occupancies.
(b) Effective Date. Within 18 months after
notice to the owner of a violation of this
appendix, plans for compliance shall be
submitted and approved, and within 18 months
thereafter, the work shall be completed or
the building shall be vacated until made to
conform, provided that if the Fire Chief
declares that conditions in violation of
this appendix also constitute a dangerous
building under Section 302 of the Dangerous
Building Code or Section 2.201 of UFC, the
Fire Chief shall determine the time
compliance requirements in accordance with
Section 401 of the Dangerous Building Code.
(c) Alternate Materials and Methods. Alternate
materials and methods may be used, provided
such materials or methods comply with the
spirit and intent of this appendix.
The Fire Chief may modify any of the
provisions of this appendix in conformance
with Section 2.301 of this code.
- 23 -
(d) Responsibilities Defined. Every owner
remains liable for violations of duties
imposed upon him by this code even through
an obligation is also imposed on the
occupants of his building, and even though
the owner has, by agreement, imposed on the
occupant the duty of furnishing required
equipment to comply with this code.
Every owner, or his agent, in addition to
being responsible for maintaining his
building in a sound structural condition,
shall be responsible for keeping that part
of the building or premises which he
occupies or controls in a clean, sanitary
and safe condition, including the shared or
public areas in a building containing two or
more dwelling units.
Every owner shall, where required by this
code, the health ordinance or the Health
Officer, furnish and maintain such approved
sanitary facilities as required, and shall
furnish and maintain approved devices,
equipment or facilities for the prevention
of insect and rodent infestation, and where
infestation has taken place, shall be
responsible for the extermination of any
inspects, rodents or other pests when such
extermination is not specifically made the
responsibility of the occupant by law or
ruling.
Every occupant of a dwelling unit, in
addition to being responsible for keeping in
a clean, sanitary and safe condition that
part of the dwelling or dwelling unit or
premises which he occupies and controls,
shall dispose of all his rubbish, garbage
- 24-
and other organic waste in a manner required
by the health ordinance and approved by the
Health Office.
Every occupant shall, where required by this
code, the health ordinance or the Health
Officer, furnish and maintain approved
devices, equipment or facilities necessary
to keep his premises safe and sanitary.
(e) Substandard Buildings. All buildings or
portions thereof which are determined to be
substandard as defined in Section 10 of this
Appendix are hereby declared to be public
nuisances and shall be abated by repair,
rehabilitation, demolition or removal in
accordance with the procedure specified in
Section 401 of the Dangerous Building Code;
provided however that the time compliance
requirements of Section l(b) of this
appendix will apply if the condition(s) are
determined by the Fire Chie~ to be
substandard and not rise to the level of a
dangerous building defined in Section 302 of
the Dangerous Building Code or Section 2.201
of the UFC.
DEFINITIONS
Nuisance.
The followin§ shall be defined as nuisances:
1. Any public nuisance known at common law or in equity
jurisprudence.
2. Any attractive nuisance which may prove detrimental to
children whether in a building, on the premises of a
building, or upon an unoccupied lot. This includes any
abandoned wells, shafts, basements or excavations;
abandoned refrigerators and motor vehicles; or any
structurally unsound fences or structures; or any
- 25-
lumber, trash, fences, debris or vegetation which may'
prove a hazard for inquisitive minors.
3. Whatever is dangerous to human life or is detrimental to
health, as determined by the Health Officer.
4. Overcrowding a room with occupants.
5. Insufficient ventilation or illumination.
6. Inadequate or unsanitary sewage or plumbing facilities.
7. Uncleanliness, as determined by the Health Officer.
8. Whatever renders air, food or drink unwholesome or
detrimental to the health of human beings, as determined
by the Health Officer.
2. EXITS
(a) Number of Exits. Every floor above the first story
used for human occupancy shall have access to at
least two separate exits, one of which may be an
exterior fire escape complying with Subsection (d)
of this section. Subject to the approval of the
Building Official or Fire Chief, an approved ladder
device may be used in lieu of a fire escape when
the construction feature or location of the
building on the property make the installation of a
fire escape impracticable.
EXCEPTION: In all occupancies, second stories with
an occupancy load of 10 or less may have one exit.
An exit ladder device when used in lieu of a fire
escape shall conform with U.B.C. Standard No. 33-3
and the following:
1. Serves an occupant load of 10 or less or a
single dwelling unit or guest room.
2. The building does not exceed three stories in
height.
3. The access is adjacent to an opening as
specified for emergency egress or rescue or
from a balcony.
- 26 -
4. Shall not pass in front of any building opening
below the unit being served.
5. The availability of activating the device for
the ladder is accessible only from the opening
or balcony served.
6. So installed that it will not cause a person
using it to be within 6 feet of exposed
electrical wiring.
(b) Stair Construction. All required stairs shall have
a minimum run of 9 inches and a maximum rise of 8
inches and shall have a minimum width of 30 inches
exclusive of handrails. Every stairway shall have
at least one handrail. A landing having a minimum
30-inch run in the direction of travel shall be
provided at each point of access to the stairway.
EXCEPTION: Fire escapes as provided for in this
Section.
EXCEPTION: On building of Types III, IV and V,
provided the exterior stairs are constructed of
wood not less than 2-inch nominal thickness.
(c) Corridors. Corridors of Groups A, B, E, I, H and
R, Division 1 Occupancies serving as an exit for an
occupant load of 30 or more shall have walls and
ceilings of not less than one-hour fire-resistive
construction as required by this code. Existing
walls surfaced with wood lath and plaster in good
condition or 1/2 inch gypsum wallboard or openings
with fixed wired glass set in steel frames are
permitted for corridor walls and ceilings and
occupancy separations when approved. Doors opening
into such corridors shall be protected by 20-minute
fire assemblies or solid wood doors not less than 1
3/4-inch-thick. Where the existing frame will not
accommodate the 1 3/4-inch-thick door, a 1 3/8-
inch-thick solid bonded wood core door or
equivalent insulated steel door shall be permitted.
- 27 -
Doors shall be self-closing or automatic-closing by
smoke detection. Transoms and openings other than
doors from corridors to rooms shall comply with
Section 3305 (h) of this code or shall be covered
with a minimum of 3/4-inch plywood or 1/2-inch
gypsum wallboard or equivalent material on the room
side.
EXCEPTION: Existing corridor walls, ceilings and
opening protection not in compliance with the above
may be continued when such buildings are protected
with an approved automatic sprinkler system
throughout. Such sprinkler system may be supplied
from the domestic water system if it is of adequate
volume and pressure.
(d) Fire Escapes.
1. Existing fire escapes which in the opinion of
the Fire Chief comply with the intent of this
section may be used as one of the required
exits. The location and anchorage of fire
escapes shall be of approved design and
construction.
2. Fire escapes shall comply with the following:
Access from a corridor shall not be through an
intervening room.
All openings within 10 feet shall be protected
by three-fourths-hour fire assemblies. When
located within a recess or vestibule, adjacent
enclosure walls shall be of not less than one-
hour-fire-resistive construction.
Egress from the building shall be by a clear
opening having a minimum dimension of not less
than 29 inches. Such openings shall be
openable from the inside without the use of a
key or special knowledge or effort. The sill
of an opening giving access shall be not more
than 30 inches above the floor of the building
or balcony.
- 28 -
Fire escape stairways and balconies shall
support the dead load plus a live load of not
less than 100 pounds per square foot and shall
be provided with a top and intermediate
handrail on each side. The pitch of the
stairway shall not exceed 60 degrees with a
minimum width of 18 inches. Treads shall be
not less than 4 inches in width and the rise
between treads shall not exceed 10 inches. All
stair and balcony railings shall support a
horizontal force of not less that 50 pounds per
lineal foot of railing.
Balconies shall be not less that 44 inches in
width with no floor opening other than the
stairway opening greater that 5/8 inch in
width. Stairway openings in such balconies
shall be not less that 22 inches by 44 inches.
The balustrade of each balcony shall be not
less that 36 inches high with not more than 9
inches between balusters.
Fire escapes shall extend to the roof or
provide an approved gooseneck ladder between
the top floor landing and the roof when serving
buildings four or more stories in height having
roofs with less than 4:12 slope. Fire escape
ladders shall be designed and connected to the
building to withstand a horizontal force of 100
pounds per lineal foot; each rung shall support
a concentrated load of 500 pounds placed
anywhere on the rung. All ladders shall be at
least 15 inches wide, located with 12 inches of
the building and shall be placed flatwise
relative to the face of the building. Ladder
rungs shall be 3/4 inch in diameter and shall
be located 12 inches on center. Openings for
roof access ladders through cornices and
- 29 -
similar projections shall have minimum
dimensions of 30 inches by 33 inches.
The lowest balcony shall be not more that 18
feet from the ground. Fire escapes shall
extend to the ground or be provided with
counterbalanced stairs reaching to the ground.
Fire escapes shall not take the place of
stairways required by the codes under which the
building was constructed.
Fire escapes shall be kept clear and
unobstructed at all times and maintained in
good working order.
(e) Exit and Fire Escape Signs. Exit signs shall be
provided as required by this code.
EXCEPTION: The use of existing exit signs may be
continued when approved by the Fire Chief.
All doors or windows providing access to a fire
escape shall be provided with fire escape signs.
(f) Exits. Every dwelling unit or guest room shall
have access directly to the outside or to a public
corridor. All buildings or portions thereof shall
be provided with exits, exitways and appurtenances
as required by Chapter 33 of the Uniform Building
Code.
Every sleeping room below the fourth story shall
have at least one operable window or exterior door
approved for emergency escape or rescue. The units
shall be operable from the inside to provide a full
clear opening without the use of separate tools.
All escape or rescue windows from sleeping rooms
shall have a minimum net clear opening of 5.7
square feet. The minimum net clear opening height
dimension shall be 24 inches. The minimum net
clear opening width dimension shall be 20 inches.
Where windows are provided as a means of egress or
rescue they shall have a finished sill height not
more than 44 inches above the floor.
- 30 -
4. ENCLOSURE OF VERTICAL SHAFTS
Interior vertical shafts, including but not limited to
stairways, elevator hoistways, service and utility
shafts, shall be enclosed by a minimum of one-hour fire-
resistive construction. All openings into such shafts
shall be protected with one-hour fire assemblies which
shall be maintained self closing or be automatic closing
by smoke detection. All other openings shall be fire
protected in an approved manner. (Existing fusible
link-type automatic door closing devices may be
permitted if the fusible link rating does not exceed
135 - F.)
EXCEPTIONS:
1. In other than Group 1 Occupancies, an enclosure will
not be required for openings serving only one
adjacent floor.
2. Stairways need not be enclosed in a continuous
vertical shaft if each story is separated from other
stories by one-hour fire-resistive construction or
approved wired glass set in steel frames. In
addition, all exit corridors shall be sprinklered
and the openings between the corridor and occupant
space have at least one sprinkler head above the
openings on the tenant side. The sprinkler system
may be supplied from the domestic water supply if of
adequate volume and pressure.
3. Vertical openings need not be protected if the
building is protected by an approved automatic
sprinkler system.
5. FIRE PROTECTION
Ail buildings or portions thereof shall be provided with
the degree of fire-resistive construction as required by
the Uniform Building Code for the appropriate occupancy,
type of construction and location on property; and shall
be provided with the appropriate fire-extinguishing
- 31 -
systems or equipment required by Chapter 38 of the
Uniform Building Code.
6. BASEMENT ACCESS OR SPRINKLER PROTECTION
An approved automatic sprinkler system shall be provided
in basements or stories exceeding 1500 square feet in
area and not having a minimum of 20 square feet of
opening entirely above the adjoining ground level in
each 50 lineal feet or fraction there of exterior wall
on at least one side of the building. Openings shall
have a minimum clear dimension of 30 inches. Exception:
Group R, Division 3, Occupancies.
If any portion of a basement is located more than 75
feet from required openings, the basement shall be
provided with an approved automatic sprinkler system
throughout. Sprinkler system must meet the approval of
fire chief and building official in those structures as
required above.
7. STANDPIPES
Any buildings over four stories in height shall be
provided with an approved Class I or Class III standpipe
system.
8. SMOKE DETECTORS
Every dwelling unit and every guest room in a hotel or
lodging house used for sleeping purposes shall be
provided with smoke detectors installed in accordance
with this code.
9. SEPARATION OF OCCUPANCIES
Occupancy separations shall be provided as specified in
Section 503 of this code. When approved by the Fire
Chief, existin9 wood lath and plaster in good condition
or 1/2-inch gymsum wallboard may be acceptable where
one-hour occupancy separations are required.
- 32 -
10. SUBSTANDARD BUILDINGS
DEFINITION
(a) General. Any building or portion thereof,
including any dwelling unit, guest room or suite of
rooms, or the premises on which the same is
located, in which there exists any of the following
listed conditions to an extent that endangers the
life, limb, health, property, safety or welfare of
the public or the occupants thereof shall be deemed
and hereby is declared to be a substandard
building.
(b) Nuisance. Any nuisance as defined in this code.
(c) Inadequate Exits. All buildings or portions
thereof not provided with adequate exit facilities
as required by this code except those buildings or
portions thereof whose exit facilities conformed
with all applicable laws at the time of their
construction and which have been adequately
maintained and increased in relation to any
increase in occupant loan, alteration or addition,
or any change in occupancy.
When an unsafe condition exists through lack of, or
improper location of exits, additional exits may be
required to be installed.
(d) Inadequate Fire-protection or Fire-fighting
Equipment. All buildings or portions thereof which
are not provided with the fire-resistive
construction or fire-extinguishing systems, or
early warning equipment required by this code,
except those buildings or portions thereof which
conformed with all applicable laws at the time of
their construction and whose fire-resistive
integrity and fire-extinguishing systems or early
warning equipment have been adequately maintained
and improved in relation to any increase in
occupant load, alteration or addition, or any
change in occupancy.
- 33 -
(e) Improper Occupancy. Ail buildings or portions
thereof occupied for living, sleeping, cooking or
dining purposes which were not designed or intended
to be used for such occupancies.
a. Addition of a permit exemption. UPC, Section 20.6 is
hereby amended to read as follows:
Application for Permit
20.6 Any person legally entitled to apply for and
receive a permit shall make such application on forms
provided for that purpose. He shall give a
description of the character of the work proposed to
be done, and the location, ownership, occupancy and
use of the premises in connection therewith. The
Administrative Authority may require plans,
specifications or drawings and such other information
as he may deem necessary. Permits shall only be
issued to persons certified pursuant to RCW 18.106;
~Dvided, the owner of real property may obtain a
permit to do plumbing or drainage work on his real
property.
If the Administrative Authority determines that the
plans, specifications, drawings, descriptions or
information furnished by the applicant are in
compliance with this Code, he shall issue the permit
applied for upon payment of the required fee as
hereinafter fixed.
b. Supplement regarding permit fees. The "Schedule of
Fees" within UPC, Section 20.7 is hereby supplemented
to include the following:
For Group R, Division Basic fee only when plumbing
and/or mechanical permit
3, and Group M obtained in conjunction with
occupancies ...... building permit for new or
remodel work; all other work
- 34 -
shall use appropriate
provisions of Section 20.7
For each private
swimming pool ..... $40.00
For each semi-public
swimming pool ..... $50.00
For each public
swimming pool ..... $75.00
c. Amendment regarding inspection notification. UPC,
Section 20.9 is hereby amended to read as follows:
Notification
20.9 It shall be the duty of the person doing the
work authorized by the permit to notify the
Administrative Authority, orally or in writing, that
said work is ready for inspection.
It shall be the duty of the person doing the work
authorized by the permit to make sure that the work
will stand the test prescribed elsewhere in this
Code, before giving the above notification. Any
person who calls for and receives a test and/or
inspection where, in fact, the work is not ready to
be tested and/or inspected shall pay to the
Administrative Authority a fee of $30.00 which must
paid prior to any further call for inspection and/or
test.
SECTION ~_~_~_~_O_~__AD~9~ts.-
a. Addition sections added to Uniform Sign Code:
Add a definition to Chapter 2
Section 203.
Billboard.
Means a flat surface, as of a panel, wall or fence on
which bills are posted, a bulletin board or a
structure built for posting or placing advertising,
pictures and reading matter.
-35-
b. Add Chapter 15 to read as follows:
Section 1501.
Conformance to Zoning Regulations.
Signs may be constructed and maintained in those
districts within the City authorized by the current
City of Bremerton Zonin~ Ordinance.
Section 1502.
Certificate of Insurance - owner to file when -
Amount every person who owns a billboard(s) shall
keep on file with the City Clerk a Certificate of
Insurance for the amount of one million dollars per
occurrence for bodily injury and property damage.
No insurance shall be required for a billboard the
solid portion of whose advertising surface contains
less than forty - eight square feet.
Section 1503.
Zoning Compliance.
Billboards may be constructed and maintained in those
districts within the City authorized by the current
City of Bremerton Zoning Ordinance.
Section 1504.
Construction - Dimension and Open Space Requirements.
a. A vertical dimension of a billboard located on
the ground and having a solid face shall not
exceed fifteen (15) feet nor shall the height
above the ground exceed thirty (30) feet Except
when determined by the Building Official that the
ground beneath the billboard is below sidewalk
grade, in which case the billboard shall not be
higher than thirty (30) feet above the sidewalk
in front of the billboard.
b. Billboards located on the 9round shall have an
open space of at least eighteen (18) inches
- 36 -
between the lower edge thereof and the ground.
This space may be occupied by lattice work,
provided that the open spaces in said lattice are
at least equal in width to the width of the
members of which the lattice is constructed.
Section 1505.
Obstructing or Projecting Billboards Prohibite~ When.
a. Billboards placed on walls or roofs of buildings
shall be located so as not to interfere with the
use of any fire escape or standpipe or obstruct
necessary windows or interfere with egress from
the building.
No billboards placed against the walls of a
building shall project into any street or alley a
greater distance than is permitted for appendages
on buildings.
Section 1506.
Billboards Located Above Building Roofs -
Restrictions.
a. No billboard, other than electric sign, shall, if
located above the roof of a building, have an
advertising surface whose vertical dimension
exceeds twenty feet, nor shall it be higher than
twenty-five feet above the roof. Electric signs
located above the roof of a building shall not be
higher than seventy-fire feet above said roof.
b. All bents supporting the face of a billboard
shall, if located above the roof of a building,
be at least six feet apart and the bottom of the
face shall be at least five feet above the roof.
c. The advertising surface of such billboard must be
no closer to the front lot line than five feet,
or be in line with the average depth of the front
line of the buildings adjacent on each side.
- 37 -
Section 1507.
Unsafe or defective billboards - Notice to Repair or
Remove Authorized When.
Any Dillboard which may be or become unsafe or
defective, and any billboard which may be hereafter
erected, altered or reconstructed contrary to the
requirements of this chapter, shall be removed or
made to conform to the terms and requirements of this
chapter by the owner thereof or by the owner of the
ground upon which the same is built, upon receipt of
notice so to do from the building inspector. It
shall be the duty of the building inspector to serve
notice on any person maintaining any billboard not in
conformity with the provisions of this chapter, which
notice shall require the immediate removal of such
billboard or alteration thereof to conform to the
requirements of this chapter.
Section 1508.
Billposter's Name Required Where.
Every billposter shall cause his name to plainly
appear at all times on every structure, or portion
thereof, upon which he placed advertisements.
d. Add Chapter 16 to read as follows:
Political Signs. Ail signs relating to the
nomination or election of any individual for
public political office or advocating any measure
to be voted upon at any special or general
election are political signs and shall be subject
to the following regulations:
Section 1601.
Political signs shall not be displayed more than
seven days after a general election; provided, that
those signs which relate to candidates or issues
- 38 -
which appeared on the ballot for a primary election
but shall not appear on the ballot for a general
election shall be removed within seven days after the
date of the primary election.
Section 1602.
No political sign shall be erected upon any property
without the permission of the resident or owner
thereof.
Section 1603.
No political sign of any nature shall be attached in
any manner to any utility pole, light standard,
directional signpost of right-of-way fence, or in any
manner which would obstruct the vision of drivers
upon streets or alleys.
The fee for politi ~ [_~0~'~~ one dollar,
except that no fee sx a political
sign thirty inches by _~r inches, or under,
in size. All persons putting up political signs of
any size shall first obtain a permit for such purpose
from the building department prior to the placement
of any signs.
~12~_ Mobile Homes~
a. Definition. "Mobile home" shall mean a factory-
assembled structure having more than three hundred
twenty (320) square feet of gross floor area, capable
for using as a dwelling unit, with its own chassis
and capable of being towed on public highways through
the use of its own axles and wheels; Provide, a
mobile home shall not lose its character as a mobile
home by the removal of its wheels and axles or its
placement on a permanent foundation.
- 39 -
b. Pursuant to the authority of RCW 19.27.060(3) mobile
homes are hereby excluded from the provisions of the
Uniform Building Code, Uniform Mechanical Code,
Uniform Plumbing Code (but only as such applies to
internal plumbing) and Regulations for Barrier-Free
Facilities. Mobile homes are not exempted from the
remainder of the City of Bremerton Building and Fire
Safety Code.
c. Before any mobile home is located or placed on any
lot or parcel, the person desiring to locate or place
the mobile home must obtain a permit from the
Building Official. The fee for such permit shall be
seventy-five dollars ($75.00) except that it shall be
fifty dollars ($50.00) within a mobile home park.
d. The Building Official shall issue the permit if the
mobile home conforms to the requirements of the City
of Bremerton Zoning Ordinance and meets the mobile
home installation requirements of WAC 296-150B, as
not or hereafter amended.
SECTION 13. Factory - B~]~
a. Definition. "Factory-built housing" shall mean any
structure designed primarily for human occupancy
(other than a mobile home) the structure or any room
of which is either entirely or substantially
prefabricated or assembled at a place other than the
building site.
b. Pursuant to RCW 43.22.450 through RCW 43.22.490 and
RCW 19.27.060(3), factory-built housing is hereby
excluded from the provisions of the Uniform Building
Code, Uniform Mechanical Code, Uniform Plumbing Code
(but only as such applies to internal plumbing) and
Regulations for Barrier-Free Facilities. Factory-
built housing is not exempted from the remainder of
the City of Bremerton Building and Fire Safety Code.
- 40-
c. Each unit of factory-built housing shall have a
permanent foundation. No unit of factory-built
housing shall be located or placed upon any lot or
parcel until the following have occurred:
(1) A person desiring to locate or place a unit of
factory-built housing shall submit to the
Building Official a foundation plan which must
be approved by the same. If the plan is
approved the Building Official shall issue a
permit authorizing the placement or location.
(2) A fee in the amount of seventy-five dollars
($75.00) shall be paid to the Building
Department at the time plans are submitted.
This fee shall be used to defray the inspections
set forth in (3) and (4) below.
(3) The Building Department shall ascertain that the
unit of factory-built housing meets the
requirements of the City of Bremerton Zoning
Ordinance and that the foundation forms have
been properly set;
(4) Subsequent to the inspection mentioned in (3)
above the Building Official shall, once the
foundation has been poured, the forms removed,
and the mud sill in place, ascertain if the
foundation has been properly constructed.
(5) Those approvals mentioned in Item 3 above have
been obtained.
~ Danger~_~~Code Amendments
1. ADDITION OF COMPLAINT PROCEDURES - DBC 401-404 are
amended to read as follows:
401:
(a) Commencement of Proceedings. Whenever the
Building Official has inspected or caused to be
inspected any building and has found and
determined that such building is a dangerous
- 41 -
building, (s)he shall commence proceedings to
cause the repair, vacation or demolition of the
building.
(b) Complaint. The Building Official shall issue a
complaint to the record owner and such other
persons with a legal interest in the building or
land as set forth in 401~ and shall post the
complaint in a conspicuous place on the
property. The complaint shall contain:
1. The street address and legal description
sufficient for indentification of the
premises upon which the building is located.
2. A statement that the Building Official has
found the building to be dangerous with a
brief and concise description of the
conditions found to render the building
dangerous under 302 of this Code.
3. A statement that a hearing will be held
before the Board of Appeals, at a place
therein fixed, not less than ten (10) days
nor more than thirty (30) days after the
serving of the complaint, and that all
parties in interest shall be given the right
to file an answer to the complaint, to
appear in person, or otherwise, and to give
testimony at the time and place in the
complaint.
(c) Hearing on the Complaint. The rules of evidence
prevailing in courts of law or equity shall not
be controlling in hearings before the board or
officer. A copy of such complaint shall also be
filed with the auditor of the county in which
the dwelling, building, or structure is located,
and such filing of the complaint or order shall
have the same force and effect as other lis
pendens notices provided by law.
- 42 -
(d) Imminent Danger. If the building or structure
is in such a condition as to make it immediately
dangerous to the life, limb, property, or safety
of the public or adjacent property, the Building
Official may dispense with the complaint
procedures and immediately issue a notice
containing an order.
(e) Notice Containing Order. If, after the hearing
on the complaint, the Building Official
determines that the building or structure is a
dangerous building as defined by 302, (s)he
shall issue a notice containing an order
directed to the record owner of the building.
The notice and order shall contain:
1. The street address and a legal description
sufficient for identification of the
premises upon which the building is located.
2. A statement that the Building Official has
found the building to be dangerous with a
brief and concise description of the
conditions found to render the building
dangerous under the provisions of 302 of
this Code.
3. A statement of the action required to be
taken as determined by the Buildin9
Official.
(i) If the Building Official has
determined that the building or
structure must be repaired, the order
shall require that all required
permits be secured therefor and the
work physically commenced within such
time (not to exceed 60 days from the
date of the order) and completed
within such time as the Building
Official shall determine is reasonable
under all of the circumstances.
- 43 -
(ii) If the Building Ofiicial has
determined that the building or
structure must be vacated, the order
shall require that the building or
structure shall be vacated within a
time certain from the date of the
order as determined by the Building
Official to be reasonable.
(iii) If the Building Official has
determined that the building or
structure must be demolished, the
order shall require that the building
be vacated within such time as the
Building Official shall determine is
reasonable (not to exceed 60 days from
the date of the order); that all
required permits be secureG therefor
within 60 days from the date of the
order, and that the demolition be
completed within such time as the
Building Official shall determine is
reasonable.
4. Statements advising that is any required
repair or demolition work (without vacation
also being required) is not commenced within
the time specified, the Building Official
(i) will order the building vacated and
posted to prevent further occupancy
until the work is completed, and
(ii) may proceed to cause the work to be
done and charge the costs thereof
against the property or its owner.
5. Statements advising
(i) that any person having any record
title or legal interest in the
building may appeal from the notice
- 44 -
containing the order to the Appeals
Board, provided the appeal is made in
writing as provided in this Code and
filed with the Office of the Building
Official within thirty (30) days from
the date of service of such notice and
order;
(ii) that the cost of said appeal is $75.00
which is refundable in the event the
appellant prevails at said hearing;
and
(iii) that failure to appeal will constitute
a waiver of all right to an
administrative hearing and
determination of the matter.
(f) Service of Complaint Notice and Containing
Order. The complaint and the notice containing
the order, shall be posted on the property; and
one copy thereof shall be served on each of the
followin9 if known to the Building Official or
disclosed from official public records; the
holder of any mortgage or deed of trust or other
lien or encumbrance of record; the owner or
holder of any lease of record; and the holder of
any other estate or legal interest of record in
or to the building or the land on which it is
located. The failure of the Building Official
to serve any person required herein to be served
shall not invalidate any proceedings hereunder
as to any other person duly served or relieve
any such person from any duty or obligation
imposed on him by the provisions of this
section.
(g) Method of Service. Service of the complaint
notice containing the order shall be made upon
all persons entitled thereto either personally
- 45 -
or by mailing a copy of such notice and order by
certified mail, postage prepaid, return receipt
requested, to each such person at his address as
it appears on the last equalized assessment roll
or the county or as known to the Building
Official. If no address of any such person so
appears or is known to the Building Official,
then a copy of the notice and order shall be so
mailed, addressed to such person, at the address
of the building involved in the proceedings.
The failure of any such person to receive such
notice shall not affect the validity of any
proceedings taken under this Section. Service
by certified mail in the manner herein provided
shall be effective on the date of mailing.
(h) Proof of Service. Proof of service of the
complaint and notice containing the order shall
be certified to at the time of service by a
written declaration under penalty of perjury
executed by the persons effecting service,
declaring the time, date, and manner in which
service was made. The declaration, together
with any receipt card returned in
acknowledgement of receipt by certified mail
shall be affixed to the copy of the notice and
order retained by the Building Official.
402:
If compliance is not had with the order within the
time specified therin, and no appeal has been
properl~ and timely filed, the Building Official
shall file the notice containing the order in the
office of the county auditor. Whenever the
corrections ordered shall thereafter have been
completed or the building demolished so that it no
longer exists as a dangerous building on the property
- 46 -
described, the Building Official shall file a
certificate with the county auditor certifying that
the building has been demolished or all required
corrections have been made so that the building is no
longer dangerous, whichever is appropriate.
403:
Standards to be Followed. The following standards
shall be followed by the Building Official in
ordering the repair, vacation or demolition of any
dangerous building or structure:
1. Any building declared a dangerous building under
this Ordinance either shall be repaired in
accordance with the current building code or
shall be demolished at the option of the building
owner.
2. If the building or structure is in such condition
as to make it immediately dangerous to the life,
limb, property, or safety of the public or its
occupants, it shall be ordered to be vacated.
404:
Notice to vacate.
(a) Posting - Every notice containing an order to
vacate shall, in addition to being served as
provided in 401(f), be posted at or upon each
exit or the building and shall be in
substantially the following form:
DO NOT ENTER
UNSAFE TO OCCUPY
It is a misdemeanor to occupy this building,
or to remove or deface this notice.
Building Official of the City of Bremerton
(b) Compliance - Whenever such notice is posted, the
Building Official shall include a notification
thereof in the notice and order issued by him
under Subsection (e) of 401, reciting the
- 47 -
emergency and specifying the conditions which
necessitate the posting. No person shall
remain in or enter any building which has been
so posted, except that entry may be made to
repair, demolish or remove such building under
permit. No person shall remove or deface any
such notice after it is posted until the
required repairs, demolition or removal have
been completed and a Certificate of Occupancy
issued pursuant to the provisions of the
Building Code. Any person violating this
subsection shall be guilty of a misdemeanor.
701:
(a) General. After any order of the Building
Official or Board of Appeals made pursuant to
this Code shall have become final, no person to
whom any such order is directed shall fail,
neglect or refuse to obey any such order unless
such order is appealed to the superior court.
Any such person who fails to comply with any
such order is guilty of a misdemeanor.
(b) Failure to Obey Order. If, after any order of
the Building Official or Board of Appeals made
pursuant to this Code has become final, the
person to whom such order is directed shall
fail, neglect or refuse to obey such order, the
Building Official may
(i) cause such person to be prosecuted under
Subsection (a) of this section or
(ii) institute any appropriate action to abate
such building as a public nuisance. Such
work shall not be commenced if the
individual appeals to the superior court
until all judicial proceedings are
concluded.
- 48-
(c) Failure to Commence Work. Whenever the required
repair or demolition is not commenced within
thirty (30) days after any final notice and
order issued under this Code becomes effective.
1. The Building Official shall cause the
building described in such notice and order
to be vacated by posting at each entrance
thereto a notice reading:
DANGEROUS BUILDING
DO NOT OCCUPY
It is a misdemeanor to occupy this building,
or remove or deface this notice.
Building Official, City of Bremerton
2. No person shall occupy any building which
has been posted as specified in this
subsection. No person shall remove or
deface any such notice so posted until the
repairs, demolition or removal ordered by
the Building Official have been completed
and a certificate of occupancy issued
pursuant to the provisions of the Building
Code.
3. The Building Official may, in addition to
any other remedy herein provided, cause the
building to be repaired to the extent
necessary to correct the conditions which
render the building dangerous as set forth
in the notice and order, or, if the notice
and order required demolition, to cause the
building to be sold and removed and the lot
cleaned. Any such repair or demolition work
shall be accomplished and the cost thereof
paid and recovered in the manner hereinafter
provided in this Code. Any surplus realized
from the sale of any such building, or from
the demolition thereof, over and above the
cost of demolition and of cleaning the lot,
- 49 -
shall be paid over to the person or persons
lawfully entitled thereto.
702:
Upon the receipt of an application from the person
required to conform to the order and an agreement by
such person that he will comply with the order if
allowed additional time, the Building Official may,
in his discretion, grant an extension of time, not to
exceed an additional 120 days, within which to
complete said repair, rehabilitation or demolition,
if the Building Official determines that such an
extension of time will not create or perpetuate a
situation imminently dangerous to life or property.
The Building Official's authority to extend time is
limited to the physical repair, rehabilitation or
demolition of the premises and will not in any way
affect the time to appeal his notice and order.
703:
No person shall obstruct, impede or interfere with
any officer, employee, contractor or authorized
representative of this jurisdiction or with any
person who owns or holds any estate or interest in
any building which has been ordered repaired, vacated
or demolished under the provisions of this Code, or
with any person to whom such building has been
lawfully sold pursuant to the provisions of this
Code, whenever such officer, employee, contractor or
authorized representative of this jurisdiction,
person having an interest or estate in such building
or structure, or purchaser is engaged in the work of
repairing, vacating and repairing, or demolishing any
such building, pursuant to the provisions of this
Code, or in performing any necessary act preliminary
to or incidental to such work or authorized or
directed pursuant to the Code.
- 50 -
g. AMENDMENTS CONCERNING LIEN PROCEDURES DBC 909-911 are
amended to read as follows:
909:
After confirmation of the report the Treasurer shall
certify to the County Treasurer the amount of such
assessment due and owing.
910:
If the County Assessor and the County Tax Collector
assess property and collect taxes for this
jurisdiction, a certified copy of the assessment
shall be filed with the County Auditor on or before
August 10th. The descriptions of the parcels
reported shall be those used for the same parcels on
the County Assessor's map books for the current year.
911:
The County Treasurer shall enter the amount of such
assessment upon the tax rolls against the property
and pursuant to RCW 35.80.030 the same or the annual
installment shall become a part of the general taxes
for that year to be collected at the same time and
with interest at such rates and in such manner as
provided for in RCW 84.56.020, as now or hereafter
amended, for delinquent taxes.
If the legislative body of the jurisdiction has
determined that the assessment shall be paid in
installments, each installment shall become a part of
the general taxes for that year to be collected at
the same time with interest at such rate and in such
manner as provided for in RCW 84.56.020 as now or
hereafter amended, for delinquent taxes.
912:
Ail money recovered by payment of the charge or
assessment or from the sale of property at
- 51 -
foreclosure sale shall be paid to the treasurer of
this jurisdiction, who shall credit the same to the
repair and demolition fund.
Unless otherwise more specifically provided, any person,
firm, or corporation violating any of the provisions of
the City of Bremerton Building and Fire Safety Code shall
be deemed guilty of a misdemeanor, and each such person,
firm, or corporation shall be deemed guilty of a separate
offense for each and every day or portion thereof during
which any violation of any of the provisions of the City
of Bremerton Building and Fire Safety Code is conm~itted,
continued or permitted, and upon conviction of any such
violation such person firm or corporation shall be
punished by a fine of not more than one-thousand
($1,000.00) or by imprisonment for not more than ninety
(90) days, or by both such fine and imprisonment for each
violation.
f~ETIQ~_i~_~m~ e_fabill ty,
If any section, subsection, sentence, clause or phase of
the City of Bremerton Building and Fire Safety Code or
its application to any person or circumstances, is then
invalid, the remainder of the City of Bremerton Building
and Fire Safety Code, or the applications to other
persons or circumstances, shall not be affected.
- 52 -
Approved by the City Council on the First reading
this ___/f~-~_ day of ~_, 1986.
Passed by the City Council of the City of Bremerton,
Washin§ton, signed by the Mayor and attested by the City Clerk in
authentication of such passage this __~_~__. day of
~__~.~b , 1986.
OBE, Mayor
ATTEST:
KATHLEEN L. McCLUSKEY, Clerk
DD:ceu
- 53 -