Loading...
HomeMy WebLinkAbout3605 AN ORDINANCE adopting the 1979 Uniform ~-- Plumbing Code, including IAPMO installation ~~\ standards, administration chapter, appen- dices, tables and insulation standards. THE CITY OF BREMERTON DOES ORDAIN: Section 1. The 1979 Edition of the International Association of Plumbing and Mechanical Officials Uniform Plumbing Code, including the administration chapter, IA'PMO installation standards, appendices, tables, insulation standards and any amendments thereto, and excluding Chapter II Appendix I, is adopted by this reference pursuant to the provisions of RCW 35.21.180 as the official plumbing codeof the City of Bremerton. Such adoption by reference shall be subject to the amendments and additions to the adopted Uniform Plumbing Code as set forth in this chapter. Section 2. Ordinance No. 3401, Section 4 shall be amended as follows: Whenever the terms "administrative authority" or "building official" are used in this code, it shall mean the Chief of the Building Department or his authorized representa- tive. There shall be a "plumbing official" under the authority of the Chief building official. The plumbing official shall have had a minimum of five years experience in the plumbing trade as a journeyman plumber and shall hold a Washington State certificate of competency for five years as a Building Trades Journeyman Plumber. The plumbing official shall be responsible for the inspections and enforcement of the Uniform Plumbing Code and the Uniform Mechanical Code. The plumbing official shall be responsible to the chief building official for enforcement of these codes and any other related requirement that the chief building official may request. Section 3. Ordinance 3401, Section 9, sub-section (a) is amended as follows: Plans, specifications and drawings may be required to be filed and approved before issuance of any permit for all buildings except single family dwellings. The official may require such plans and specifications to be prepared and de- signed by an engineer or architect licensed by the State of Washington to practice as such. The approval of any plans or specifications shall not be conStrued to sanction any violations of this code. Section 4. Section 315, Chapter 3 of the Uniform Plumbing Code is amended by adding the following subsections: (g) All water piping installed in any unheated spaces shall be protected from freezing. (h) All water piping shall be installed so that the completed systems, including both hot and cold water systems, can be drained. Section 5. Appendix D, Part A, Section D1.0 (c) is amended to read as follows: All rainwater piping located underground outside any building, with twelve inches or less cover, shall be service weight cast iron soil pipe, Type L copper tube, schedule 40 A.B.S. or R.V.C. or other material approved by the building official. Section 6. Appendix D, Part A, Section D1.0 is amended to add the following: (e) Down spout drains arenottO be connected to foundation drain. All rainwater and surface water is to be controlled. Plans for such systems shall be required and approved by the building official. (f) Foundation drains shall be of approved materials and installed to manufacturer's standards. The drains shall run to a location twenty- four inches beyond the building before connecting with a roof drainage system and then drain to an approved location with solid, smooth piping. Section 7. Part 1, Section 20.7, Schedule of Fees subsection shall be amended to read as follows: For issuing each permit $ 4.50 In addition For each plumbing fixture or trap or set of fixtures on one trap (including water, drainage piping and backflow protection therefore) 3.00 For each building sewer and each trailer park sewer 5.00 Roof drains inside building 3.00 Rainwater systems 5.00 For each water heater and/or vent 3.00 For each gas piping system of one (1) to four (4) outlets 3.00 For each gas piping system of five (5) or more, per outlet 5.00 For each industrial waste per- treatment interceptor, including its trap and vent, excepting kitchen type grease interceptors functioning as fixture traps. 5.00 For installation, alteration or repair of water piping and/or water treating equipment 3.00 For repair or alteration of drainage or~'~en~ ~iping 3.00 For each lawn sprinkler system on any one meter, including backflow protection devices therefore 5.00 FOr ea~hadditional sprinkler head .30 For vacuum breakers or back flow protective devices on tanks, vats etc. or for installation on unprotected plumbing fixtures in- cluding necessary water piping - one (1) to four (4) 3.00 Ground works 7.50 Post and beam 7.50 Swimming pool - public 40.00 Swimming pool - private 20.00 Hot tub or spa over 2 ft. deep 10.00 Section 8. Ordinance No. 3401, Section 2, Section 6, Section 10, Section 11 and Section 12 are hereby repealed APPROVED by the City Commissioners on the first reading this _ ~'T~ day Of September, 1980. PASSED by the City Commissioners of the City of Bremerton, signed by the Mayor and attested by the City Clerk in authentication of such passage this ~ ~ day of September, 1980. ATTEST: HLEEN L. MANDIO, City Clerk