HomeMy WebLinkAboutCARR BLVD., 1333 (. 345 - 6th Street, Bremerton, WA 98337 (360) 473-5275 Fax: (360) 473-5278 CITY OF BREMERTON DEPARTMENT OF COMMUNITY DEVELOPMENT PERMIT NUMBER 880600125 DATE ISSUED: 03/10/2006 ASSESSOR NUMBER: APPLICANT NAME: OWNER NAME: CONTRACTOR: LENDER NAME: ZONING: R10 PHONE: PHONE: PHONE: 1333 CARR BLVD PO BOX 5237, BREMERTON, WA 98312 PO BOX 5237, BREMERTON, WA 98312 SITE ADDRESS: ADDRESS: ADDRESS: ADDRESS: 3719-002-027-0001 SIMMONS STEVE SIMMONS STEVE SELF SUBMITTED: 03/10/2006 09/06/2006 STATUS: VALUATION: Fence Permit ISSUED Fence Permit Fees $25.00 2211 $4.50 0236 $29.50 Building Code Edition: Occupancy Group: Type of Construction: Flood Zone: Setbacks: Sanitation Method: Number of Bedrooms: ~ NEW SIDE YARD FENCE 3 FT TALL IN FRONT ifA~D SET BACK OF 15 FEET THEN 6 FEET TALL TO BACK OF PROP -R;f . . State Surcharge TOTAL FEES: Inspection Requests DCD: Building Inspections L&I: Department of Labor and Industries (360) 473-5870 (360) 415-4000 Fire Inspections HID: Bremerton, Kitsap County Health District PW: Department of Public Works (360) 473-5380 (360) 337-5285 (360) 473-5270 This permit shall become null and void if the described and authorized by this permit has not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned at any time after the work is commenced for a period of 180 days. it is the responsibility of the permit holder to see that the required inspections are made. Failure to obtain required inspections may result in stoppage of the work until such time that the permit holder can susbstantiate to the City of Bremerton that the concealed work meets or exceeds code requirements. Any demolition, testing, or financial burden shall be borne directly by the permit holder. Failure to substantiate code requirements will indemnify the City against any and all responsibility or liability connected with the construction. I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel provisions of any State or local law regulating construction or the performance of the construction. If listing the owner as general contractor, I certify that I am exempt from the requirements of the State Contractor's Registration Law under Section 3, Chapter 126, Laws of 1967. All revisions to an approved plan require DCD review and approval prior to performing work. All building and tenant occupancy permits are required to pass final inspection prior to permit expiration and obtain a certificate of occupancy prior to use or occupancy. all conditions of zoning, building codes, and State and Federal laws. SIGNATURE OF OWNER OR AGENT: 3 --- /c/-C>? PRINTED NAME: DATE: CONDITIONS City of Bremerton's approval of this application pertains only to the City's regulatory jurisdiction, and thus compliance with City regulations does not necessarily ensure compliance with federal or state laws. 1. (DCD-01) DCD: Prior to performing any renovation or demolition work, Puget Sound Clean Air Agency (Clean Air Agency) and Washington Department of Labor and Industries (L&l) regulations require an asbestos survey be performed to determine whether there are asbestos- containing materials in the work area or structure. The asbestos survey must be conducted by and EPA-certified (AHERA) building inspector (except renovation or owner-occupied single family residences).DCD: For more information, please contact Clean Air Agency through their web site at www.cleanair.org or by phone at 800-552-3565 or 206-689-4058. The L&I web site can be found at www.lni.wa.gov/p-ts/asbestos/asbestos.htm. DCD: Validity of permit. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Washington State Building code or of any other ordinance of the City of Bremerton. Permits presuming to give authority to violate or cancel the provisions of the Washington State Building code or other ordinances of the City of Bremerton shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the building official from requiring the correction of errors in the construction documents and other data. The building official is 2. (DCD-02) ~ ~~ Page 1 of 2 m ~~~~! CITY OF BREMERTON DEPARTMENT OF COMMUNITY DEVELOPMENT PERMIT NUMBER 880600125 DATE ISSUED: 03/10/2006 345 - 6th Street, Bremerton, WA 98337 (360) 473-5275 Fax: (360) 473-5278 ASSESSOR NUMBER: APPLICANT NAME: OWNER NAME: CONTRACTOR: LENDER NAME: SUBMITTED: 3719-002-027-0001 SIMMONS STEVE SIMMONS STEVE SELF ZONING: R10 PHONE: PHONE: PHONE: PHONE: SITE ADDRESS: ADDRESS: ADDRESS: ADDRESS: ADDRESS: 1333 CARR BLVD PO BOX 5237, BREMERTON, WA 98312 PO BOX 5237, BREMERTON, WA 98312 09/06/2006 STATUS: ISSUED also authorized to prevent occupancy or use of a structure where in violation of the Washington State Building code or of any other ordinances of the City of Bremerton. All portions of fence must be located on applicant's private property and may not encroach onto public property or the City's right-of-way. By signing this permit, applicant certifies that the depiction of property lines shown on site plan are true and correct. PERMIT CARD MUST BE POSTED IN A CONSPICUOUS PLACE ON FENCE AS SOON AS CONSTRUCTION BEGINS. MINIMUM INSPECTIONS REQUIRED Inspection requests must be received by 8:00am in order to be scheduled for same day. To request an inspection, please call (360) 478-5275 and be sure to provide your permit number, name on permit, site address, contact phone number, and inspection type. 3. (DCD-23) 4. (DCD-24) 5. (DCD-25) 03/10/2006 APPROVED: 03/10/2006 EXPIRATION: Final Inspection - Fence :id'~ ///L: .~ Page 2 of 2 , .~. w ~ ~M: ~ 00 ~6@ @) co~~,~p:~nnlt Application J:;8u b Od I 2..S" Klo \) (S') I l~lfitrnfjnt~'~ Department of Community Development 345 - 6th Street, Suite 600 Bremerton, W A 98337 (360) 473-5275 * Fax (360)473-5278 CITY OF BREMERTON Site Address: ( 32-1 ClJ- 'I?- K) BCU--lD ~R~.fY\\vJA, q~3/.:2- I CONTRACTOR: Address: I J:2-C( C"A ~R JJlrV D Cit , State, Zi : srl)'Vt ( v.-JA J ~g-3 / ~ Contact N;:tme: S\(G-J~ S I W\ \"V1.6 '(\5 Contact Phone #: ~2> 7'3 / III 3 / Tax IO/Parcel #: 37/9- 00;l ,- OA7- 00 D I Scope of work proposed: /30 P'i ~ p "6' R R l J/iGY f~;JL;C- ***********It is the property owner's responsibility to determine actual property lines************ Front Yard Back Yard Side Yard Fence Hei ht :3 K iO~ \ S"' ~ 0P Vicinity Map D Permit Fee Surcharge Total Fees :lS--~9- r,OV 2-7'6U Application for which no permit is issued within 180 days following the date of application shall expire by limitation, and plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the building official. The building official may extend the time for action by the applicant for a period not exceeding 180 days on request by the applicant, showing the circumstances beyond the control of the applicant have prevented action from being taken. No applicant shall be extended more than once. In order to renew action on an application after expiration, the applicant shall resubmit plans and pay a new plan review fee. /~/-"P ?~ ~;:;/ .. ~/;/.#: - ',--...------ // P;~,,/ .?~~'----~ _4!..../ Applicant's Signature -5//0-- Ob Date .,1 . BU1LDING PERMIT , INSPECTION CARD Site Address ~~~~~ A.J, N&\ Me..b -p, pE- NC~ .. - Building I!\.. Plumbing jt Mechanical D Alarm/Sprinkler DURING INSPECTIONS THE BUILDING PERMIT & APPROVED PLANS SHALL BE ON SITE Permit#!!!!Q~- 00 ~ For Inspections Call (360) 473- 5870 PROTECT THIS CARD FROM THE WEATHER D [P@~u @~ ~Du~ 1 st Erosion Control In Place f/OUNlJA TION no NOT 1'0111{ CONCRETE Foundation Footing PRIOI{ TO APPROV AI, Foundation Walls Plumbing Ground Work In Slab Mechanical Footing Insulation ~PUJMBING rA.. edL 1 (l;q. Rough In (lJUi- 3/z../o (. ~'l/ANI('AI, Duct I Vent I' , 3//u/;- -~PlPH Support I Test I Meter set I'd Under Floor Framing Va 3 PRAMIN(i If I.~I & 2 lid d Shear & Hold Down Connections . arf appf'(JI'e ~ L&I Electrical Approved Ventilation Requirements ~ Framing th Under-floor G' 4: INSULA TION Walls Ceiling -- 5th ~ SHEETROCK ~ ~ 6th BUILDING 473-5870 I:) FINAl, All of the above must he PI NAL ELE( 'TRICAL Dept. of Lahor & IllduWl' 415-4000 appmved priOl' to final WATER MAINTENANCE 473-5927 ...... Grease Trap, Back Flo1/'. Waler Meters PUBLIC Driveway Approach 473-5270 WORKS Sewer Connection 473-5270 FIRE 473-5384/5385 ILL FINAL INSPECTIONS COMPLETED Occupancy Approval (Single 473-5870 ramify Residence OnM Approved Date Notes "7 ~ - DO NOT OCClJPV B1JILDING WITHOliT BUILDING DEPARTMENT APPROVAL PROTECT THIS CARD FROM THE WEAl1fHR -R '-vs{ ~2's\- 3 } 11<> ~ O~~~ '\~S" \"A,-b~ ttJ g~~ VVle8.. ~ u.-G f{ ~ /)() 'l . " . t'l\ 1(;' v ( .JJ:'Do '3fl f' , \ j c.;- 0 t~O I b'6> .1 "'1 ...-' ~ I S-D R LM ~9 ~ -o~ " i ~ " .~, l b--i) 12 S ~ l ~'\ o.~ 12i 1t?'1 Y R M '3q~ (MeS-. SV~'J l2(.. Js-Y tS" ~ \fv..-(. 1'2 t{ ( ?Z- \ Z;V o x.. vvvA o~ YJruet V tLC /(0 lL;() r2~ Y2 ~ ''jl6 I C;-S- 1 -:;4 Iti" i ':,'""0 t c;S- (5) cJ1 ~M~ -------., -- - -'-. - I' B..........-. . . ... . ~: '" .. DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING DIVISION CITY OF BREMERTON Bremerton, Washington (360) 473-5275 INSPECTION REPORT PERMIT #: -5~ O,~ - 000 8 \ ADDRESS:2~20 ~ ~<2.VV'Y /lv.e (f) 1?<Z;t" ~.~Z"~~1I1{ -P\\.V~~mr Code} s-.eJ-,\-6"Y1 1'3~9J7} '"the 111 eJ ,'c.al 9 tL 5 f Ip. rtlJ /11 f.t, <?, + be 5 Cl- bYlj .. fi et:{ 'l-Q I 5 D PSI (:1 U(~ v1 i VM Ltm # t! IkVtJI~ f~d }-ilL~ S ~r e.. f,..oWl /( 0 To I 3tLJ>sj~ tD CV'thS &n1t1~d--t~ 'ies1- per tL.PQ.. t 327.1 ~ /t1liLL Joe J1~/ne~. ~tn1fA2t E~",LtIo :300-173-5727 , R. tYl 31 6 12fl1. .3 9~ /(14{ :3 60 o)(y I :l~ /';(? / /D MeJ 1~S /'J.~ I~~ I ~'3 - fVl~& V (1..(. J~ S- f ~:J /31 Date: :3/I[OG Phone(1(;,O 433-5.2<6t,. tilif JI~ · I INs'P~~OR ,~,.. 'l\ ..,. CITY OF BREMERTON DEPARTMENT OF COMMUNITY DEVELOPMENT PERMIT NUMBER 880600081 DATE ISSUED: 02/24/2006 Im.;mt :'. !"' ,~ " d '~ . . " "1 ~-'" 345 - 6th Street, Bremerton, WA 98337 (360) 478-5275 Fax: (360) 478-5278 <'\ ASSESSOR NUMBER: APPLICANT NAME: OWNER NAME: CONTRACTOR: LENDER NAME: 3967-004-001-0402 ZONING: INST SITE ADDRESS: 2520 CHERRY AVE STIRRETT JOHNSEN PHONE: ADDRESS: 5555 WESTGATE ROAD NW, SILVERDALE, WA 98383 HARRISON HOSPITAL PHONE: ADDRESS: 2520 CHERRY ST, BREMERTON, WA 98310 STIRRETT JOHNSEN INC PHONE: (360) 692-6128 ADDRESS: 5555 WESTGATE RD NW, SILVERDALE, WA 98383 PHONE: ADDRESS: SUBMITTED: 08/23/2006 STATUS: 02/24/2006 EXPIRATION: VALUATION: $850.00 $34.15 2215 $35.70 2211 $4.50 0236 $74.35 1 NEW MED GAS OUTLET Building Code Edition: Occupancy Group: Type of Construction: Flood Zone: Setbacks: Sanitation Method: Number of Bedrooms: mmercial Building Permit wi Mechanical/Plumbing Mechanical Fixture Fee Building Permit State Surcharge TOTAL FEES: Square Footage: Bid Price from Applicant Inspection Requests DCD: Building Inspections L&I: Department of Labor and Industries (360) 473-5870 (360) 415-4000 Fire Inspections HID: Bremerton, Kitsap County Health District PW: Department of Public Works ISSUED @ 1 TOTAL (360) 473-5380 (360) 337-5285 (360) 473-5270 This permit shall become null and void if the described and authorized by this permit has not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned at any time after the work is commenced for a period of 180 days. It is the responsibility of the permit holder to see that the required inspections are made. Failure to obtain required inspections may result in stoppage of the work until such time that the permit holder can susbstantiate to the City of Bremerton that the concealed work meets or exceeds code requirements. Any demolition, testing, or financial burden shall be borne directly by the permit holder. Failure to substantiate code requirements will indemnify the City against any and all responsibility or liability connected with the construction. I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel provisions of any State or local law regulating construction or the performance of the construction. If listing the owner as general contractor, I certify that I am exempt from the requirements of the State Contractor's Registration Law under Section 3, Chapter 126, Laws of 1967. All revisions to an approved plan require DCD review and approval prior to performing work. All building and tenant occupancy permits are required to pass final inspection prior to permit expiration and obtain a certificate of occupancy prior to use or occupancy. I have read, and agree to abide _~y t~.:.conditions of thi:~ng all conditions of zoning, building codes, and State and Federal laws. ~~~:iURE OF OWNER OR ~ --:-Yb~ PRINTED NAME: ~~.i-y rr DATE: ~I/~~~ CONDITIONS City of Bremerton's approval of this application pertains only to the City's regulatory jurisdiction, and thus compliance with City regulations does not necessarily ensure compliance with federal or state laws. 1. (DCD-01) DCD: Prior to performing any renovation or demolition work, Puget Sound Clean Air Agency (Clean Air Agency) and Washington Department of Labor and Industries (L&I) regulations require an asbestos survey be performed to determine whether there are asbestos- containing materials in the work area or structure. The asbestos survey must be conducted by and EPA-certified (AHERA) building inspector (except renovation or owner-occupied single family residences).DCD: For more information, please contact Clean Air Agency through their web site at www.cieanair.org or by phone at 800-552-3565 or 206-689-4058. The L&I web site can be found at www.lnLwa.gov/p-ts/asbestos/asbestos.htm. DCD: Validity of permit. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Washington State Building code or of any other ordinance of the City of Bremerton. Permits presuming to give authority to violate or cancel the provisions of the Washington State Building code or other ordinances of the City of Bremerton shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the building official from requiring the correction of errors in the construction documents and other data. The building official is 2. (DCD-02) ~ ~ Page 1 of 2 p.D1" -ii : ~; ,< ' j , \~~~~;,~~ ,,,j, - ", .1-... CITY OF BREMERTON DEPARTMENT OF COMMUNITY DEVELOPMENT PERMIT NUMBER 880600081 DATE ISSUED: 02/24/2006 345 - 6th Street, Bremerton, WA 98337 (360) 478-5275 Fax: (360) 478-5278 ASSESSOR NUMBER: 3967 -004-001-0402 ZONING: INST SITE ADDRESS: 2520 CHERRY AVE APPLICANT NAME: STIRRETT JOHNSEN PHONE: ADDRESS: 5555 WESTGATE ROAD NW, SILVERDALE, WA 98383 OWNER NAME: HARRISON HOSPITAL PHONE: ADDRESS: 2520 CHERRY ST, BREMERTON, WA 98310 CONTRACTOR: STIRRETT JOHNSEN INC PHONE: (360) 692-6128 ADDRESS: 5555 WESTGATE RD NW, SILVERDALE, WA 98383 LENDER NAME: PHONE: ADDRESS: SUBMITTED: 02/24/2006 APPROVED: 02/24/2006 EXPIRATION: 08/23/2006 STATUS: ISSUED 3. (OTHER) also authorized to prevent occupancy or use of a structure where in violation of the Washington State Building code or of any other ordinances of the City of Bremerton. Must be installed in accordance to the Uniform Plumbing Code 2000 Edition Chapter 13 paragraph 1302.0 ~ MINIMUM INSPECTIONS REQUIRED Inspection requests must be received by 8:00am in order to be scheduled for same day. To request an inspection, please call (360) 478-5275 and be sure to provide your permit number, name on permit, site address, contact phone number, and inspection type. Mechanical Plumbing Groundwork Plumbing Rough-In Final Inspection - Building Qty Description FIXTURE LIST Qty 1 Descriptior C-Miscellaneous Mechanical Equipment Page 2 of 2 ." BSolo [:Do;-, Tlt/S7 Dl.s'Jb Dept. of Community Development * 345 - 6th Street, Suite 600 * Bremerton * WA * 98337-1873 Site Address: c2 5;20 e1+~~Y !tve CONTRACTOR: Stirrett Johnsen Inc. Address: 5555 West ate Road NW Cit , State, Zi : Silverdale, WA 98383 License # & Ex . Date: STIRRJ*281 B6 Contact Phone #: 360-308-2080 OWNER: Harrison Medical Center Address: 2520 Cher Avenue Cit , State, Zi : Bremerton, WA 98310 Phone #: Tax ID/Parcel #: NO. TYPE OF EQUIPMENT NO. TYPE OF FIXTURE RANGE WATER CLOSET WOOD/PELLET STOVE/GAS FIREPLACE BATHTUB GAS FURNACE btu: LAVATORY (BATH SINK) CONVERSION BURNER btu: SHOWER UNIT HEATER btu: KITCHEN SINK BOILER btu: DISHWASHER GAS PIPING LAUNDRY TRAY EVAPORATION COOLERS btu: CLOTHES WASHER AlC UNIT btu: WATER HEATER HEAT PUMP btu: URINAL REHEAT BOX but: DRINKING FOUNTAIN EXHAUST FANS FLOOR SINK OR DRAIN RANGE HOOD (RESIDENTIAL) WATER PIPING & ALTERATION RANGE HOOD (COMMERCIAL) GREASE TRAPIINTERCEPTOR CLOTHERS DRYER HOSE BIBBS INCINERATOR LAWN SPRINKLER SYSTEM DUCT AL TERA TION SWIMMING POOL TANK TYPE: BLDG. SEWER: (MOBILE/MOVED HOME) REFRIGERATION UNIT ROOF DRAINS A 1 OTHER: - ---- I OTHER: YA/J JI ~ ~~,!:J tbLJ OTHER: OTHER: MECHANICAL FEES: PLUMBING FEES: TOTAL FEES: B i fJ ?tf- JLE ~ B SP..,o . --H-. ~ "? NOVo{ I y\ VJIN6 .;;. J~~<L Applicant's Signature ~/L3lb ~ Date . CITY OF BREMERTON DEPARTMENT OF COMMUNITY DEVELOPMENT 345 - 6th Street, Suite 600, Bremerton, WA 98337-1873 (360) 473-5275 Fax: (360) 473-5278 ~fli . .~.tJlrr:; ,~ashiel::;:PCONROY ':.: ..Mr, 02l24i2006~- ,'u ',"w;;;e:'" :;~~ , ,;17::;.' ription_ BB06 00081 BB06 00081 BB0600081 Mechanical Fixture Fee Building Permit State Surcharge Receipt Number: BDQQ005766- -, '- , \' ~ ' ' Paxer}Payee;Name::;' STIRR~::rrJOHJ'~SEt'LM~Thm T. ~,'-'. ,~ ~ ,w@t,C "'#'{'C 0:1*' "0~P:\"W .W;W: ;17::; Trao ;17::; "Co~ ;17::; " -~, ,:if: ' 1/2215 1/2211 1/0236 Rec~ftff# , RllY.l1lent' Metliod CHECK Previous,Paymeht Histt:\W Fe scription ..'<~' W;W W;W 7012 Total: -. $ 74.35 $74.35 ,F ;;;1' ,/ "'<$ Origfnal4:ee- ,;; 'M' 'Amount :;;, , :;;; '::~, , 0/:' , 0: $34.15 $35.70 $4.50 Total: $34.15 $35.70 $4.50 $74.35 ,/; i,-Y/ ~, ~Amoun{Paid .:L Permit # , ~{c.::.... 'c,>""v, 1=el;; Balance- $0.00 $0.00 $0.00 Page 1 of 1 ASSESSOR NUMBER: APPLICANT NAME: OWNER NAME: CONTRACTOR: LENDER NAME: SUBMITTED: VALUATION: Building Permit Plan Review Fee State Surcharge TOTAL FEES: CITY OF BREMERTON DEPARTMENT OF COMMUNITY DEVELOPMENT PERMIT NUMBER 8806 00333 DATE ISSUED: 06/05/2006 345 - 6th Street, Bremerton, WA 98337 (360) 473-5275 Fax: (360) 473-5278 3967-004-001-0402 HARRISON HOSPITAL HARRISON HOSPITAL FOX FIRE PREVENTION INC 05/15/2006 $1,951.00 $69.25 2211 $45.01 4580 $4.50 0236 $118.76 Inspection Requests DCD: Building Inspections L&I: Department of Labor and Indus~ries ZONING: INST SITE ADDRESS: 2520 CHERRY AVE PHONE: ADDRESS: 2520 CHERRY ST, BREMERTON, WA 98310 PHONE: ADDRESS: 2520 CHERRY ST, BREMERTON,WA 98310 PHONE: (360) 871-1985 ADDRESS: PO BOX 594, PORT ORCHARD, WA 98366 PHONE: ADDRESS: APPROVED: 06/01/2006 EXPIRATION: 12102/2006 STATUS: ISSUED Fire Sprinkler Permit HARRISON HOSPITAL - FIRE SPRINKLER INSTAllATION IN ANGlO SUITE Building Code Edition: Occupancy Group: Type of Construction: Flood Zone: Setbacks: Sanitation Method: Number of Bedrooms: Square Footage: Bid Price from Applicant 1 TOTAL (360) 473.5380 '(360) 337-5285 (360) 473-5270 This permit shall become null and void if the described and authorized by this permit has not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned at any time after the work is commenced for a period of 180 days. It is the responsibility of the permit holder to see that the required inspections are made. Failure to obtain required inspections may result in stoppage of the work until such time that the permit holder can susbstantiate to the City of Bremerton that the concealed work meets or exceeds code requirements. Any demolition, testing, or financial burden shall be borne directly by the permit holder. Failure to substantiate code requirements will indemnify the City against any and all responsibility or liability connected with the construction. I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority.to violate or cancel provisions of any State or local law regulating construction or the performance of the construction. If listing the owner as general contractor, I certify that I am exempt from the requirements of the State Contractor's Registration Law under Section 3, Chapter 126, Laws of 1967. All revisions to an approved plan require DCD review and approval prior to performing work. All building and tenant occupancy permits are required to pass final inspection prior to permit expiration and obtain a certificate of occupancy prior to use or occupancy. (360) 473-5870 (360) 415-4000 Fire Inspections H/D: Bremerton, Kitsap County Health District PW: Department of. Public Works PRINTED NAME: of this permit including all conditions of zoning, building codes, and State and Federal laws. DATE: G- -~ - DC:.. CONDITIONS . City of Bremerton's approval of this application pertains only to the City's regulatory jurisdiction, and thus compliance with City regulations does not necessarily ensure compliance with federal or state laws. 1. (CROSS-03) 2. (DCD-01) 3. (DCD-02) Cross Connection: Existing double detector check valve assembly must be tested after all work is completed. All approved assemblies must be tested by a certified Washington State backflow assembly tester. DCD: Prior to performing any renovation or demolition work, Puget Sound Clean Air Agency (Clean Air Agency) and Washington Department of labor and Industries (l&l) regulations require an asbestos survey be performed to determine whether there are asbestos- containing materials in the work area or structure. The asbestos survey must be conducted by and EPA-certified (AHERA) building inspector (except renovation or owner-occupied single family residences).DCD: For more information, please contact Clean Air Agency through their web site at www.cleanair.org or by phone at 800-552-3565 or 206-689-4058. The l&1 web site can be found at www.lnLwa.gov/p-ts/asbestos/asbestos.htm. DCD: Validity of permit. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Washington State Building code or of any other ordinance of the City of Bremerton. Permits presuming to give ~ ~. ~ Page 1 of 2 > i< '. CITY OF BREMERTON DEPARTMENT OF COMMUNITY DEVELOPMENT PERMIT NUMBER 8806 00333 DATE ISSUED: 06/05/2006 345 - 6th Street, Bremerton, WA 98337 (360) 473-5275 Fax: (360) 473-5278 ASSESSOR NUMBER: 3967-004-001-0402 ZONING: INST SITE ADDRESS: 2520 CHERRY AVE APPLICANT NAME: HARRISON HOSPITAL PHONE: ADDRESS: 2520 CHERRY ST, BREMERTON, WA 98310 OWNER NAME: HARRISON HOSPITAL PHONE: ADDRESS: 2520 CHERRY ST, BREMERTON, WA 98310 CONTRACTOR: FOX FIRE PREVENTION INC PHONE: (360) 871-1985 ADDRESS: PO BOX 594, PORT ORCHARD, WA 98366 LENDER NAME: PHONE: ADDRESS: SUBMITTED: 05/15/2006 APPROVED: 06101/2006 EXPIRATION: 12/02/2006 STATUS: ISSUED authority to violate or cancel the provisions of the Washington State Building code or other ordinances of the City of Bremerton shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the building official from requiring the correction of errors in the construction documents and other data. The building official is also authorized to prevent occupancy or use of a structure where in violation of the Washington State Building code or of any other ordinances of the City of Bremerton. Per NFPA 13 Hanger/bracing/coverage to be done on site MINIMUM INSPECTIONS REQUIRED Inspection requests must be received by 8:00am in order to be scheduled for same day. To request an inspection, please call (360) 478-5275 and be sure to provide your permit number, name on permit, site address, contact phone number, and inspection type. 4. (Project-Specific) ~ Cross Connection Control Fire Sprinkler Flush Fire Sprinkler Hydro Fire Sprinkler Cover Final Inspection - Fire Page 2 of 2 f;f30& 0 () 333 coif~ ,5 . ~ -( NST PERMIT CENTER ,<, Department of Community Development * 286 4th Street * Bremerton * W A * 98337 (360) 478-5275 * Fax (360) 478-5278 Building Permit Application APPLlCANT: 0 OWNER ~ CONTRACTOR 0 AUTHORIZED AGENT Site Address 1,020 ctlct(2..R. 5'\ Tax Account Number: 3~~+ -o~-CC\- 10'2. P~VtAr:rorJ OWNER or Authorized Agent: .A~lJ\. Address:?e> 1;0<< C;:)~ <-l City,.State, Zip ~(<.:"'\ O~t'~o (3Cec> )'31-1 /98 S- ~@@@DW[gill) MAY 15 2006 Check the type of application for below: D NEW SINGLE-FAMILY RESIDENCE o NEW DUPLEX D NEW MA"JUFACTURED HOME D RESIDENTIAL REMODEL D RESIDENTIAL ADDITI~N D RESIDENTIAL REPAIR o o o o COMMERCIAL REPAIR o NEvV MULTI-FAMILY ~ TENANT IMPROVEMENT NEW COMMERCIAL COMMERCIAL REMODEL COMMERCIAL ADDITJON BREMERTON-DEPT. OF ~M~~~~,&,Qf~T o NEW ACCESSORY SLOG D NEW SIGN D STRUCTURE DEMOLITION o GRADING ,(Cubic yards: _) ~ OTHER YES D NO D ~/Z-fr1 ic Lf/ZS IS THIS PROPERTY WITHIN 200 FEET OFA SHORELINE? Swpe of Work. Proposed: Ai.JO , hLoCA-rK:..1- ~Cl J e' ~~ I I Square Footage: Dwelling: G~rage: Decks: Valuation 1'1~/, (JiO ~5 Surcharge 50 Total Fees ':'" ""- Application for which no permit is issued wit n 180 days following the date of application shall expire by limitation, and plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the building official. The building official may eX\end the time for action by the applicant for a period not exceeding 180 days on request by the applicant showing the circumstances beyond the control of the applicant have prevented action from being taken. No applicant shall be extended more than once, In order to renew action on an application after expiration, the applicant shall resubmit plans and pay a new plan review fee. APPLICANTS SIGNATURE: ...-<// ~ 3 a DATE: S-~/Z-& ,f It '\! .rtF'''"r''''"':o f'; (. ,'"....,-" ',,- '......... \." ~ Bulletin 136 Rev.M ro c m. 5' . Reliabl~ Model F1 FR Model F1 FR Recessed Quick Response Sprinklers Model F1 FR Sprinkler Types Standard Upright 00 R rN R 0 \\n ~ [Q) A Standard Pendent D L5 ~ LS ~ LS 0 Conventional ' Vertical Sidewall MAY 1 5 2006 Horizontal Sidewall - HSW 1 Deflector BREMERTON-Df..:PT C j=- Model F1 FR Recessed &O.MMU~DEVELOP~ ENT . . ~pnllN y~ Recessed Pendent Recessed Horizontal Sidewall - HSW 1 Deflector Upright Listings & Approvals 1. Listed by Underwriters Laboratories, Inc. (UL) 2. Listed by Underwriters' Laboratories of canF' ~aO(iUlal'; 3. Certified by FM Approvals 4. Loss Prevention Council (LPC, UK) 5. NYC BS&A No. 587-75-SA 6. Meets MIL-S-901C and M1L-STD 167-1. TOM 7. Verband der Schadenversicherer (Vd~al'fY')l e(j~ 8. NYC MEA 258-93-E ~'" . r<?' UL Listing Category ~ ~APPRO' veo ~ Sprinklers, Automatic & Open <::> . cr Quick Response Sprinkler a ~~I~Uide Number JUN OiJ:l. .~ f Patents: US Patent No. 6,374,920' ppiiesto' Model F1 FR Vertical Sidewall sprink~ ~/ Product DescriPtlOn~ t. 0 0 ~ 3 Reliable Models F1 FR and F1 FR Recessed Sprinklers are quick response sprinklers which combine the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. . The Models F1 FR and F1 FR Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in Jaboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1 FR and F1 FR Recessed sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manu- factured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. The balance of parts are made of brass, copper and beryllium nickel. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid ex- Horizonta~ Sidewall HSW 1 Deflector -'- (;) OJ JJ m < ~ Pendent Conventional Recessed Pendent (Model FP Shown) pands, forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the watef\.vay and allowing the deflector to distrib- ute the discharging water. Application Quick response sprinklers are used in fixed fire protec- tion systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Asso- ciation or the approving Authority Having Jurisdiction. Quick response sprinklers are inten.ded for. installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Reliable Automatic Sprinkler Co., Inc. 525 North MacQuesten Parkway, Mount Vernon, New York 10552 ~ Model F1 FR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model 0 Sprinkler Wrench Installation Data: Sprinkler Type _K Factor __ Sprinkler Approval . Sprinkler Identification Standard-Upright (SSU) and Pendent (SSP) Number (SIN) Deflectors Marked to Indicate Position US Metric Height Organization SSU SSP r~" (15mm) Standard Orifice with )(" NPT IRJ~) Thread 5.6 80 2.2:' 156mm) 1,2,3,4,5,6,7 R3625 R3615 ';,~ "(20mm) Laroe Orifice with ~/" NPT (R%)Thread 8.0 115 2.3" 15Smm) 1,2,3,4,7,S R3622 R3612 ;<." (17mm) Small Orifice with };" NPT (Rl,) Thread 4.2 60 2.2" (56mm) 1,2,8 R3623 R3613 %" (1Omm) Small Orifice with)(" NPT (R};) Thread 28 40 2.2" 156mm) 1,2,S R3621 R3611 10mm Orifice XLH with R%" Thread 4.2 60 56mm 4,6,7 R3624 R3614 Conventional-Install in Uprioht or Pendent Position 10mm Orifice XLH with RYe Thread 4.2 60 56mm - R3674 15mm Standard Orifice witil )~" NPT (R);) Thread 5.6 80 56mm 4,6,7 R3675 20mm LarQe Orifice with %" NPT (R%)Thread 8.0 115 58mm 4,7 R3672 Upright Pendent Conventional Model F1 FR Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR1 Sprinkler Wrench Installation Data: Nominal Thread K Factor Sprinkler Approval(1) Sprinkler Identification Orifice Size US Metric Height Organizations Number (SIN) );" (15mm) X;' NPT (RY2) 5.6 80 2.2" (56mm) 1,2,3.4,5,7.8 R3615 '%2' (2Omm) %" NPT (R%) 8.0 115 2.3" (58mm) 1.2,3,8 R3612 7/;0" (11mm) );" NPT (RY2) 4.2 60 2.2" (56mm) 1,2,8 R3613 %" (1Omm) Y," NPT (RY2) 2.8 40 2.2" (56mm) 1,2,8 R3611 10mm R3' 4.2 60 56mm 4,7 R3614 ,8 (1) Refer to escutcheon data table for approvals and dimensions. r36FGOf_L (} ADJUSTMENT ~ ir'- 2 5/8" OIA [SS.7mmj ~ . HOLE: !N CElUNG 2 5/7S'" DIA. [58.7mm] --" CUP I 1-1;~ i i r ~==~~f~::L, I ! I 1 "'-1"Xl/2~REDUCER r----I-----y' I \. I / I I I ---; I .J----Li r OJ I'~ FACE OF FITTING ~ TO FAct OF CtlLlNG . . O!MIIDNITJ \. / ',,'"I>) t /36rGOS_' ~ L ? r/~ ~ HOLE Dir'<. '[~7.2mmJ w,." ADJUSI;;", I'! j ," if 1/2~ REDuCER TlJRN COLLA.P. UNTIL TiGHT Ac'4/NST S.J!lR1M<.L rR WRENCH 80SS-.... - "" '" [ -;;1/3;;-'--D~ - [72_2mmJ FACE: OF 1FIITlNG TO (I) J C[fUNC fMc.-NSION ~ [J.2mm} 'J.",(I) CEJUNG~ /,,~'V -'~S:I- b~'~,~ ... (1) REFfR ro Ff ~ F2 FSCUTCH[ON ClArA TAB?E FOR APPROvALS AND DfMmS/ONS. (r) REFER TO FP f:SCUTCHEON DtITA TABLE FOR APPROVALS AND DIMEN5fON5. 2. Model F1 FR Quick Response Vertical Sidewall Sprinkler i Installation Wrench: Model 0 Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Thread K Factor SWin kler Approval Sprinkler Identification Orifice Size US Metric eight Organizations Number (SIN) V2" W' NPT (RV2) 5.6 80 2.2" (56mm) 1,2,3,6,8 R3685 15mm W' NPT (RV2) 5.6 80 22" (56mm) 4(1) (1) LPC Approval is for Pendent position only. Orientation Deflector to Ceiling Dimension (Min. - Max.) Uoriqht 4" - 12" (102mm - 305mm) Pendent 6" -12" (152mm - 305mm) Vertical Sidewall I US Patent No. 6,374,920 Model F1 FR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model 0 Sprinkler Wrench Installation Data: Approval Organizations Sprinkler K Factor and Type of Approval Identification Nominal Thread Sprinkler Light Ordinary Number (SIN) Orifice Size US Metric Length Hazard Hazard )f" (15mm) y/, NPT(RY2) 5.6 80 2.63" (67mm) 1.2,3,5,8 1,2,5,8 R3635 NOTE: UL, ULC and MEA Listing permits use with F1 or F2 recessed escutcheon. Horizontal Sidewall 136FG04 ,~/j//%>//\. .. (7) FACE OF FiTTING TO U ~ WALL DIMENSION I J 1/4'. MIN. I I. [:57.8mm] I ,2 7/~: HOLE:, Dill. I f--1/S" 4'.-6' I [.."'](_2mm~ I I r3'"''' [101,6mffi-152Amm] I I .. i c_..<mm) CEiLING TO 1" X 1/2" REDUCER / '" 0~ 1 DCFLECTOR I ""ncic:./" 1- --,.1- I : ,~III': : 1 15/16" DfA.' nil;:: i tl! [49.2m""J n~, :--- ~Ji I 227/32" DiA. 1 I W:: ; J, I {72.2mm] ,\..~~\_l-__(,"--L.J ~ --../ ",,~J' TURN COLLAR UNTiL -j ~::y - - nCHT AG~INST SPRINh:LER ~ I WRENCH 80SS. ~ I (7) --i r-- AWUSIMtNI (1) REF[R TO EscumCEON DATA TABLE FOR APPROVALS AND DIMENSIONS. 3. Installation Quick response sprinklers are. intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Model F1 FR Recessed Quick Response Sprinklers 'are to be installed as sho,Nn. The Model F1 or F2 Escutcll80ns illus- trated are the only recessed escutcheons to be used vvith the Model F1 FR Sprinklers. The use of any other recessed escutch- eon will void all approvals and negate all warranties. When installing Model F1 FR Sprinklers, use the Model D Sprin- kler Wrench. When installing Model F1 FR Recessed Pendent or Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. RE- MOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Re- moval of the protectors before this time may leave the bulb vul- nerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Temperature Ratings . Sprinkler . Max. Ambient Bulb Classification Ten1DEiI'ature oc of' Temp. Color Ordinary 57 135 1ClCfF (28OC) Orange Ordinary 68 155 1000F (28OC) Red Intermediate 79 175 15O"F (66OC) Yellow Intermediate 93 200 15O"F (66OC) Green High (1) 141 286 225"F (107OC) Blue (1) Not available for recessed sprinklers. Escutcheon Data EscIJcheon '''A'l~ Face c:J Fitting Model Approvals Adjustment Dimensioo IoCeiIingCl' Wall Dimension 1); " F1 1,2.4,8 Max Recess (38.1mm) 31,0"-'%6" Min Recess Yo" (5mm - 24mm) (19.1mm) 1);" F2 1.2,3,4,5,7 ,8 Max Recess (38.1mm) %6"~111611 Min Recess '71, " (5mm-17mm) (24~ml Y;" FF 1,2 Max Recessed 16 1X;"(281mm) 111mml Push-wi 1X611 Thread-off 1,2 Min Recessed (24mml 1"(25.4mm) No Dimensional Figure for FP Maintenance The Models F1 FR and F1 FR Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- tle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to mini- mize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Sidewall (Vertical, Horizontal HSW1) Recessed Pendent Recessed Horizontal Sidewall HSW1 Finishes (1)(2) Standard Rnishes S rinkler Escutcheon Bronze Brass Chrome Plated Chrome Plated (3) White Polyester Coated White Painted (3) ial A lication Finishes inkier Escutcheon Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Satin Chrome Satin Chrome (1) Other finishes and colors are available on special order. Consult the factory for details. (2) FM Approvals is limited to bronze and brass, chrome or black plated finishes only. (3) FP Push-onfThread-off escutcheon Ordeiing Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Orifice Size 4. Deflector Type 5. Temperature Rating 6. Sprinkler Finish 7. Escutcheon Type 8. Escutcheon Finish (where applicable) Note: When Model F1 FR Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of govemmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputa- ble spnnkler contractors located throughout the United States, Canada and foreign countries. Manufactured by t:\ Recycled ~ Paper neliilbl~ The Reliable Automatic Sprinkler Co., Inc. (800)431-1588 Sales Offices (800)848-6051 Sales Fax (914)668-3470 Corporate Offices WWN.reliabI8sprinkier.com Internet Address Revision lines indicate updated or new data EG, Printed in U.S.A. 7/05 P/N9W9970027 .9 _. \ \ U LJ J L D I I\I.G DE PAR T M EN T B R EM E R T ON prF:MIhl' . . =::~===~::=~==:=::::==::=~=~::::=:::;~====:::==::~:===:==:===:=::=~=:=::::::~:~F~:::::~:~=:==:==:==;:::==~:~:====:=:::::==.:: (iPP l:i. cat :i. on [)at c.) Issue' Date (tSE:;C;SSUY' Acct 'il; Site L.oca.t ion Owner - Last Name ..... ~;:;t Y' eet .... City ..... Phone 'r CH'j ant · r; 1'..1 a.m t'.~ f1qent · s Na,ma (.\r ch i t c~ct · s rla.me) !"\(':! 1:311';] d'I"r'lcl ;.1..... ,....1....... ',.. r hi h. "'~' .. .. .. .... ". 'j' t. .. Mf:::C lId n J. \....<::t p. C ::I Plt1mb:inr;J 07 / 1'9/19'~)O 07/19/1'190 A~Jlicat:i.on Number 90AP02183 Permit. Number ll074 P'rojecl:; GY'oup 1 :3:33 CAF<F; HI.... V!J DE:Nl.IAM 3716 LARCH WAY W. t'IL.DE:I::{I,.JOOD Mi'1NClF~ (206) 6'/.0.....119 J First ANDREW MI State WA Zip 98036 I:> t'l ,'" r' l"" ( ,.::' () /, ) J ....J I .... \ .(.., ~,' .... Phone(:;::06 ) ..[ ] Gy'adinq [ 1 Move B~ildinq r ] t10b i 1 e Ih'lome [ hi ~:; :i, qh [ ] E3UYTl :i. h9 r '] Land Cleay' I'~ h' . .. Pa,'.,;]' no C J Under DY' DU nd r h' Demul it :ion Building ContY'actor: [,Jor k tAil:!.! be cornp 1 et ed by OVJneY'.. Natu'cc) of ~Jork:: Reroof permit composition 2500 square feet. BUilding Valuation ~1>~:::?50 ,,00 Council District Const nJct :i. on 'fYPf::) r~eB i dc)ncf.'~ UUBlness Ot he)y' f\!l::)W F<epa i 'I 1:~emodF) 1 tldd :i. t :i, on CC)nSUB 'r)~ act ::;q Feet J nspE.)ct :i ons r~equ i Y'f:,)d Lx] r ,., L .. r ] r "I r hI r ] r 'I Zon ins:; 'T'ype .", F'oundat ion F'.c am :i. no .. -I l' J iV3U.. a'.: J ()n Plumbing nechanical v.Ja 11 hOi'1i"d F' i rla:l [ ] [ ] r ] [: J r '1 L J Lx] . status Code 4 :::':.~::~~l:~~~",",""::'::::::::,:::o,,,,,=o,,,,,,,,,,~=="o,=== _......:.'_-'h_..___.': ....-.. .-,', , i . ... INSPECTION RECORD CARD CITY OF BREMERTON BUIlDING DEPARTMENT. 11074 PERMIT NUMBER ADDRESS OWNER CONTRACTOR 1333 CARR BLVD ANDREW DENHAM self PHONE PHONE 670-1191 1 FOUNDA liON 1. PERMIT ON SITE 2. CHECK PLANS TO PERMIT 3. CHECK SETBACKS 4. PROPERTY STAKES 5. FOOTING WIDTH & DEPTH 6. SOIL BEARING O.K. 7. CHECK FOR FILL a. REQUIRED STEEL IN PLACE 9. CHECK FIREPLACE FOOTING 10. ANCOR BOLTS 11. FOUNDATION VENTS 12. CRAWL ACCESS . COMMENTS: FOUNDATION INSPECTION APPROVED BY: ~- 2A FRAMING 20. FIREBLOCKING STAIRS DROP CEILINGS TUBS OR SHOWERS ROOF & CEILING LINES FURRED OUT AREAS FIREPLACE AT CEILINGS HOLES PLUGGED TOP & BOTTOM LID IN VOIDS 21. WINDOWS MEETS ENERGY CODE CLASS SAFETY GLAZING REQUIRED FIRE EXITS WINDOW SILL HEIGHT 22. CEILING HEIGHTS 23. SWAY BRACING 24. TRUSSES PROPERLY INSTALLED STAMPED PROPERLY BRACED 25. ATTIC ACCESS 26. RAFTER & JOIST SPAN 27. ROOFING, FLASHING. SHEATHING 28. SIDING 1. WIRING APPROVED 2.FOUNDATION VENTS 3. SHIELD UNDER POSTS 4. POSITNE CONNECTIONS 5. SOIL TO WOOD CLEARANCE 6. BEAM SUPPORT 7. TR. MAT. NEXT TO CONC. a. WASHERS ON ANCHOR BOLTS 9. BEAMS PROPER SIZE 10. FLOOR JOIST SPAN 11. NOTCHING & DRILLING 12. STAIRS WIDTH RISE & RUN WINDERS LANDINGS .. HEADROOM 13. ATTIC VENTILATION (upper & lower) 14. CHIMNEY STRAPS SECURED 15. FIREPLACE COMBUSTION AIR 16. FANS VENTED TO OUTSIDE 17. WATER CLOSET CLEARANCE 18. SMOKE DETECTOR 19. SHEETROCK BACKING UNDER STAIRS ABOVE GARAGE DOOR HANGERS COMMENTS: FRAMING INSPECTION APPROVED BY: 2B INSULA liON COMMENTS: 1. PROPER R- VALUE 2. VAPOR BARRIER 3. PROPER FASTENING INSULATION INSPECTION ~ APPROVED BY: M MECHANICAL 1. PERMIT ISSUED 2. FURNACE LOCATION 3. FURNACE CLEARANCE 4. 'BI VENT SIZING 5. 'B' VENT CLEARANCE 6. 'B' VENT SUPPORT 7. COMBUSTION AIR 8. DUCT SIZING 9. DUCT SUPPORT & JOINTS 10.GAS PIPING TEST 11. GAS PIPE SIZING 12. GAS PIPE SUPPORT COMMENTS: ~~'S_ 0.-.- p . PLUMBING 1. PERMIT ISSUED 2. UNDER TEST 3. WATER PIPE SIZING 4. D'WV SIZING 5. PROPER SUPPORT COMMENTS: UNDERGROUND APPROVED BY: - T 3 WALLBOARD 1. LID OVER SIDES 2. NAILING 3. W/R AT TUB OR SHOWER 4.518 UNDER STAIRS 5. FURNACE ENCLOSURE COMMENTS: WALLBOARD APPROVED BY: '~ HVAC APPROVED BY: GAS PIPING APPROVED BY: WDST 1. WOOD STOVE CLEARANCE 2. CHIMNEY CLEARANCE 3. HEARTH EXTENSION 4. CHIMNEY HEIGHT WDST APPROVED BY: ....".,......... ....-., I2lIIIAII~ -,- _ -.oil __ ....... - 6. PROPER ATTINGS 7. REQUIRED CLEANOUTS 8. PROPER GRADE 9. HWT PRES. RELIEF VALVE & LINE 10. SEISMIC STRAP ROUGH-IN APPROVED BY: -- 6. FIRE SEPARATION IN GARAGE 7. ATTIC ACCESS 8. DRAFT STOP IN ATTIC 9. PROPER CONST. OF FIRE WALLS 10. DROP CEILING & LIGHTING - -~~ .4 FINAL 1. HANDRAILS 2. GUARDRAILS HEIGHT INTERMEDIATE 3. EXHAUST FANS 4. WATERPROOFING IN SHOWERS 5. DISHWASHER A1RGAP 6. FIRE DOORS LABLED AS REQUIRED SELF CLOSING 7. FIRE DAMPERS INSTALLED 8. PENETAA TIONS IN FIRE WALLS FINAL PLMB. APPR. (comm.) FINAL MEeH, APPR. (comm.) FINAL BUILDING APPR. 9. HOT WATER TANK PAL ' .. 10. OUTSIDE GRADE 11. SOIL TO SIDING CLEARANCE 12. SMOKE DETECTORS 13. FIREPLACE HEARTH 14. SAFETY GLAZING 15. INSULATION WINDOWS MEET ENERGY CODE UNDERFLOOR & ATTICE INSUL. WATER PIPE & HEAT DUCTS 16. WOODSTOVE APPROVED 17. WINDOWS & DOORS CAULKED COMMENTS: ... ~. .. . e N9 44812 ()o /? - . f'J? /6'-3 '7 Fee $......m.__....m..___...__..m_______..._____m___________________ Receipt No. ...._.~:._____m._m:_m____h___________________m. BUILDING PERMIT CITY OF BREMERTON BUILDING DEPARTMENT F. E. IRISH, Building Inspector . ESsex 3-1411, Ext. 36 v// o:er's Value I Bldg. Dept. Value I DESCRIPTION: " $ <:9 ~ .-DoO I Lot Block Additions Address on Job __LS.fi3u_ _.__.c..~6:.,_:!E_!._____/fL~~<_____. __ ________u._Uu____u___._______ Date ______9.:-:__/_~_::_2_5(_____u_____ Building __00__00_00_____ x ____.m___u___ and ____00__________ stories ____h____h________U__ basement. Lot ________um___ x ____.m________ Front Yard _______m________u.___ Rear Yard _______.__._____________ Side Yard ________mu__.u______ Garage ____u__'___m_____._________ OCCUPANCY PERMIT REQUIRED BEFORE OCCU.PYING BUILDING Zone ________________________m____hUm____ Owner _/d/<<~dt.:__ _ __# _ u L~_/._~.._:_!_ _ _ 00 __ 00 ___ _ _ __ _ _ _ _ __ _ _ _ __ _. Address __ _ u __ ___ ____ h_ _ _u. u' _ _ u _ _ __ _ _ u __ u _ _ _ Phon e __ ____ ___ _ _ _ _ _ ___ Contra~tor _~__~__~~__u~?;,__":?4L_..;.,'!_z:;~~!.__u________ Address ___u_______._______________________________ Phone ___u.___________ This permi~ is i~sued for: (~'~r~-e.. 0~...~~u~) <~::~:~~~~:~~~:::~:~~~::C:::~~~~:::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::: All VJork to conform to all applicable building ordinances and amendments. Please note the following special instructions and requirements. DETACH HERE AND POST THIS SECTION ON JOB INSPECTION - Reinforcing steel must be inspected after placing and before covering. FORMS shall be inspected and approved before pouring. All plumbing, wiring and the frame of all buildings must be inspected and approved befo,re covering. Wood preservative to be used on all wood against masonry. Ventilate foundation and attic. Sepa- rate permits required for plumbing, wiring and heating. See City Engineer before working on streets or sidewalks. ~ ~ - -.- - _.- ~ -. - - - - -- - -- - - - --..- - - - - - - -- - --- - - - - - - -- -- - - - - - - - - - - - _.- - - - -- - - - - - --- - -- - _.- -- - - - -- - - - -- - - - - - -- - - - -- - - - - - - -- -- .-- - - -- - -- - - -- - - -- - - - -- --- - -- -- - -- -- -- - --- - - -- - --- --.---- '-j(;~ .,'\ -0. - UJL (>. d, Own er' s Signa tu re_, _ _ 1_ _ _~.~"K-, ul:.l, _ _ \CV...!.1<: 1- _ _ m _ _ _ _ ___ _ _ _ _ _ _ __ By _ _ _ __ _ _,__, __ _ _ 0 _ ~ _~ _ f.~".y:Pb.._ - 0---- _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _. _ _.. - _ _ __ _ _ __ II l' () Iiis Amhorized Agent Building Inspector __~_ _ L__ _~ _, _~/./____ ___ _ _ ______ ____ __m _____ __ __ no __m m_ _____ y!j/ ~ OF By ______ _ __ _ __,_____ ____'u____ _________ _ u__ .n____________n______ __h __.h____n_______ e e fa 'If . 'f I . : ~ I ;:fd'd/-r/#// I - I ~I . I . I --.---~._~ .-J k '2b/-~----~ . /:. e e e INTERNATIONAL CONFERENCE OF BUILDING OFFICIALS RESEAIIEH [OmmnTEE REEOmmEnDATIOn Report No. 2435 October, 1970 FAST BLOCK THE McNEAR COMPANY POST OFFICE BOX 1380 SAN RAFAEL, CALIFORNIA 94901 corners, wall ends, jambs, pilasters, etc., conventional block units are utilized with standard head joints. Cutting of the Fast Block units is only permitted at the take-up points requiring mortared head joints. Standard running bond is required and stacked bond is not permitted. Mter laying, all cells of the block are /,HIed with grout complying with Section 2403 (s) of the Uniform Building Code. Design: Construction utilizing this type of block is to be designed and reinforced in accordance with requirements of the Uniform Building Code for reinforced hollow unit masonry, with allowable stresses as set forth in Table No. 24-H of the Code, based on the 11. Description: General: Fast Block is manufactured from "I'm" for Grade "A" hollow concrete units. cement and Haydite expanded shale aggregate into 8-inch by 8- inch by 16-inch nominal double open end block having a single III. Evidence Submitted: Block details and tests are submitted. central web. The block is manufactured as a hollow load-bear.~ng Recommendation Grade "A" unit complying with U.B.C. Standard No. 24-4. The face shells are not less than 114 inches except at the ends wh~re IV. Recommendation: That the Fast Block concrete masonry they are tapered to permit grouting of the head joints betwe~'rt units described in Part II of this report are a satisfactory alternate units. The tapered central web is recessed 21/" inches to provid~method of construction to that required by the Uniform Building clearance for required horizontal wall reinforcing. (!' "\ ' eo~~ use as hollow load-bearing Grade "A" concrete masonry Bed joints are intended to receive a mortar joint .of 1)y~ep S umts.." mortar as specified in Section 2403 (r) of the ~~~ ~'\ w,I1 Thi, ,"OOrm,ndalinn i, ,ubj,ct tn .nn~l __in.lioo. ~ ! ~\ \ ~y ~J.~ '\ I. Introduction: At the request of the McNear Company San Rafael, California, the Research Committee of the International Conference of Building Officials has made a re-examination of the data submitted in connection with the use of Fast Block as a hollow load-bearing Grade "A" Unit. r0 \ -\ ~r.~ I \~ \ . . Page 1 of 1 "