Loading...
HomeMy WebLinkAboutCAMBRIAN AVE. N., 1911 \ 'y. >l~ 1. .{c. ,;'~, ',': :.1 j. *.;, .1' ... :r.* C\<:.;t 'j. ;lC.t: .j:;~ )1';j:.**...... ;~:"f *** * A.::jC ;j.'}( l{::'r:;-, '" 'f: *~':;;;:*..\'. '.i:"j;; ,:j:';l<..:t. *:\:.***'1; * ::;Cl.cj; >>:>1: RU.:EIPT 'j''.!: *..~.t;;~.; :t. .t.;r fe';,: .~ * ** I: * :t.,:, ;j:* :iOi';1' ..;~* :-;.. ',.jel. *;+;/::.k 'I: ,"'.j::+, 'I: **:1'** :oK.:;,:.:t:.j:';j('~, ;.f,:*;jo; >i;* ***:L.t***.'j< !)LUJr'T l.ll.lmbel': O~.J(I()Ol(,/ f.::1Wll.t'llL. 1.0:3/ .:.:,0 OJ/0::.'./03 1.0; 18 ('<1 ::'/Ii,'ntl: t1,:, U )0(::' C ~( No t .~q ti 0 i I'; [3J I sL01"T:':'; (' 1< I II it;: 'VI,,! .- ~ ~.. -.. ...... '-- .' - .-., .... -... ~~. .- ... -" . ,- "" ., ~-" ~ - . ,~..- .... P~.:(rn.l.'c f\i():: F\1Y ce.J j\!o: O:.l Oi)6H l'31.,U C ryp~; ;. ULDG F'L:ef'! r r t-.J/t1C:CH/P :~:7".)/f()()J. '()()"). (.j()<)~~ ';'1[.(4 t',d(1i~"::;::',:; \9111'1 '.:;(i!'1mnti!\! ;~\J! 'j 'iL HI rl'(;~:; I ,:;1:''>.1 . 4') flit':;; Pd/,!fl!:.'ill' J ,t):':l? .';'0 '(ol:a..L flU.. i)mU:.: 1 "h51 .49 Bel.1 i:< 11(:(;' ; .. 00 *~~~~~*1***~t~*#~**~t******~~****~~**~***************4****~~**** l'l\.:e.)I.I.nl (,1th: D~':<':('ri ptt...,n (\mount ]./> ':;:;:.,:,10(1't (::.:~1.1) HUlL-On.lei 1)[f-<~f\1JI iT:[';:~ 790.7S :i C,,, 3d C. 0 WI(,O:.J (() ;;';':50 ) UU T l D 1 j\jCi PI (d\! U IFCI< f'FL: ':" ~.() .. 00 l<;,--..:s.,:'.).. LOt.:";', (?:)j '.:,) iYIU::I'ii\NTI:.:,~\L F)U":i\'111 "'lJ.S 90..2r, 1 (:. <3:',:': , 1 Ol)~; (:: ::: I ::<, ) PLlJI'-H<HKi F"E w,n 'I F U.:. ~~, 94 .1.)0 (,/./03 ,.... j/ , i. 'j .; 02 36 ) :~:,f('\TE or:' (.,.I() ~3lmCH('lRCiC tj . ~5() I I .' ........'........................<~,~._~,~-~."---=----',. ~ ,:,,\ \. ;~ BREMERTON PERMIT CENTER 286 4th Street~ 8remerton~ WA 98337 phone: (360) 478-5275 FAX: (360) 478-5278 BUILDING PERMIT Applicant: 1911 N CAMBRIAN AVE NORTH CAMBRIAN 3794001 ~O~ O~OO bOc:r-b003 B J BUILDERS PO BOX 2274 BREMER TON WA 98310 373-0775 Permit No: Status: Applied: Issued: Expires: 03-0068 PENDING 02/10/2003 Job Addr: Location: Parcel No: Owner: B J BUILDERS 373-0775 PO BOX 2274 BREMERTON WA 98310 Contractor: B J BUILDERS 373-0775 PO BOX 2274 BREMERTON WA 98310 Lic ~: 8JBUI**227MC Exp: 10-1-2004 Subcontr: Oesc: SINGLE FAMILY RESIDENCE WITH GARAGE ***********************************************************~ Valuation * Permit Fees: 983.00 To~ 70.110.40 * Plan Check Fees: 513.99 1,,-.. )\( Ot her Fees: 54.50 \ ******)\(***************************************************** MECHANICAL/PLUMBING FIXTURES-- MECH-Range...................: 1 I' MECH-Gas Piping (outlets)....: 3 MECH-Exhaust Fans............: 3 11ECH-Clothes Dyyey...........: 1 PLBG-Watey Closet............: 2 PLBG-Lavatoyy. . . . . . . . . . . . . . . . : 2 PLBG-Sho,^J"'Y. . . . . . . . . . . . . . . . . . : 1 ~=~~::"::~o:::::::::::::::: ~ PLBG-ClotH ~ ()lfl~ *nJ.~..a;;.L.c;..:.{).3.......,,,., · ..... ........j fJt:t:;? :,1-0; J ~ -11., : This peymit shall become null and void if the building oy woyk auth yized bJ trC'ct ~ 5 ~,~~ -!~ ; 180 days hom the date of such peymit, oy if this building oy woyk authoYi:z:J Kc.... i,~ Drs offl4. tA/,-:l3-4,OL L ~_u_.. u__--- abandoned at any time aftey the ",'oyk is commenced foy ~ pe'riod of 180 d~ s. % - - , NOTICE - It is the yesponsibility of the peymit holdey, not the Citl' of - 'emeyton 68Ui~d ng Official to it that 'requiYed inspections a're made. The penl1it hold must no J: ) th Buil~l ' Of ;' ia1 when y inspections. Failuye of the peymit holdey to notify tho Bu ln 0 . ci 0 yequl d' ections may y ~ It in the stoppage of the ("Ioyk until such time that the p j 'hol can SUbstf1,ti he buildin~fi al that the concealed woyk meets OJ' exceeds code Ye~UiY m.nts. A 'demol~~o'k,'~es_i oy financial 'eJ'd n shall be boyne di'rectly by the peymi t holdey. Fai~ substanti code :t' ye I n i ndeOj\fY! the City against any and all yesponsibility oy liabili=:> onnec~e1L;ith h~\ lfn~ yuct~ . ; \ I heyeby ceyti fy that I have yead an a ~d thi~~ y\n.ft: and K!.r2J'1~~ \S~ le to be I e a~YYect. All pyovisions of laws and oydinances y' this t of wO~~~ll e_c~lied wit iet~~J~~eCified heyein oy not. The gyanting of a peym tJE~~ not pyesume 0 give~oYity violate oy a, el the PYOViS10ns of any othey state oy local l~ e 1~n constyuction OY' ~ peyfoymance of consb'uct 1. ',. C f}~~IA,,J t '((}lJ3-03tJ3. "(" tJ03t:. ~ 1oo.3~ o;L2/-~3I: iv'/corf' \ -! I - Signatuye: Date: the state contyactoy's yegistyation law, undey Section 3, Signatuye: ************************* ' Permit Center--Approved By. Date: D ate: !t--2-1.:::o '3 ~ ( .'~ {. \ c:~~.~,~. .2~'" J,~ \~ . ,~ "".. ~REMERTON PERMIT CENTER 286 4th Street, Bremer-ton, WA 98:"13.7 Phone:. (360) 478--5275 FItX: (360) 478-'527"a BUILDING PERMIT h:. ...; Job Addr: 1911 N CAMBRIAN AVE Location: NORTH CAMBRIAN Parcal No: ~794001-006-0300 Permit No: 03-0068 Stat.us: PENDING Applied: 02/10/2003 Issued: E:.<pires: Applicant: 8 J BUILDERS 37J-O/75 I PO 80X 221il BREJ1ER"JON WA 98310 Own~r: B J BUILDERS 373-0775 PO BOX 2274 BREMER TON WA 98310 C.ontrdctor:: 13 J BUILOEr~S PO BOX 2274 8REMEkTON WA\9B31, Subcont.r: \ l1e~(;: ~',J.fJGLE: FMiIlV HESIDU~L:E WliH I.lA~Cd;_ :c~ *~i\ rl~~ <<* ~{"K * ;:~:r ~ 7P';{~ d: 'J~:i';:' .f\~h x~~::<< 1.; A~ *,X~){, 'it'$: r}~c~<;iC~ It-:.'<< J;- *' ~>K~~x4 {.:It ~ x<*** >;'{*~{< ';((;:(:>;~~{( ~'<< >:<:K~'K 2NJGfNEERINB*BfV1510N;';:(< *'*;*~{{ ~K;{{'I1ft~r.~ ~ Valuation * Permit Fees: ~~ 98j.OO rota C L~ I ~ . u r~e. 1.551.49 /0 1 J.:l.() ,,40 ~~ Plan Check Fee~s: 512L.99 f)ddlti6~'la1. Fees: <lot) * Other Fees: 54.50 Total Permit Fee: 1,551.49 FEB 1 9 2003 373'",0775 Lie jt= 10101 Tw ~,"~""1' {'. C-H'. O' ")-1-2004 RE"CEIVE'O' - .~********~M*W*~*~*%*~****~t**~********~*************~~*~********~***************************** ~1fXHt~.JICr.>,l./PIJJM('.n.I(, f'IXTUf.FS..... 1"tf.::cr'jo+~:\r'19"'....".......".......: 1 Ht:::Cf+"'IXdS F;qrYl$.ca to lOC'k bti.: l' '...... !..'!t::Cf+,6i:r;j P1P i. nq (t'uU 1.1'1;,," ). .. .. ;:3 j-iECi+b,!'laus"t f:a,r.:". ,. " _ .. .. ., "" ; ':~ Ml~Cf'I-B~nSle Hood (I"*s).. "" H . = 1.' ,..--' ~ i"iEC[i-Cloth"$ [)n';~~'", " " " "" "" " " : 1 PL8C,'''v,I,,\"b,n 1.:ICr";;i!1L. _ " . ".. .. .. .. . " ; ::: /PC86-8athtut,1. .. .. ...... .. " .. .. . .... .. .., : ;t ~~U.\(j-L1:Ni:d:,(1ry..........",............,..~ .', PU:\l:.i~3ho',Je.t.....,.."............"...~ 1 PlBG~Kltc:he\l Sink.. .............~ 1 F'L.~\c..-r,l(:.I"M'-\8h<~\ ,....."". "... ",,", ~ It,B1rL:h'lt:h\l,".) ~.la",h(o) ...... _ ....".. _ 1 Pl8u-hfg!:""y 'HB:at~r... "....."......",: 1 rI'"LtI~"--~~'"'"/'"i 2(' ;; /), L / f' / (jr-_C i ....'k .."."t, ,. .,.* :.~~.."w C2~('...", w ,,1'1:~" " ~":".,-,,,';'~'~"~"YV'" W'",,~' ",.i.".. ,..J", ."'" ".,,,,.,, """"'1.< '" ."VI '" ":.k::::L ",.",,,,,,, ""I... ",.v 'I'''' " .v::,:,,':;.,,~. .....",yw(, ~I'" "~ r- ,'1' ''1\.''(0 ,j" ,....\"'. $,\ T. "'i~ !t\ .~4" il t'l. It... 'r~,T. It'< f{~ 'I'>...'\", ii". .?-J'P "l~ i..' ,.(\ ,f,-"ij\"I;. ~"'."\'< If". i't\; ,"".ii" t-r..1' ~i\ ""....,\'1. .,.../1'. .'1'" it'\ .1\.';>..f(\ .>t'd""'....;\ I. ,''f'. ~f\'1\ "!,,It', Ii- It- ff'.-,y..~>1\ 0'\"', "l'r, \ .'1' 11\Fr. .1'~ 'Y'. It-. "f'..7'> ,(1./;" 'f', r'1\..~,If~ ,I\..'J'o/{-. 1'" rh:L~:l p",Yflllt:. 9ha.ll be~Dm<i' 'null :iiI.n:i v,,::d.d if thG I::~Ji.ldin\-.1 .;r( wc't:'; al.J.th:,y'i.zed by this p.l::;mit: IS \lrol corrlft1el1<:;ed w:Lthnr 180 day~; h'om the deXLfj oi' (\Uch "ermH" 0'( i-f thh?, buildin:,! OY v.lo,k au.thodz-f:Kj b~' ,j!J,::~Ymit i\is St.l.$p~nd"d (:.r' ,",bano:)c)ne.d <l\l a.ny time> af !;.{:'l" 1:.1'.',' le'O"I'k i:'; /OI1lIfl&Yr,;;ed 1'1..:,,' ',' ped'".~l o.t 180 (Jays.. 7rfVrJ-/l, t4P(Jfl;:!JJ140 l\lOTJl~t is lJ.:Q~~!:J:~iJ.~~ ~} ~he f.!1C:{:~~;: not i:d/Ji~~ ~~Y'tCt;,~f~~~tl~'~\;;C%~isL~_~~:<'----- b:.J :..'\:; tfw.t t'G-c1\.lin,..::YinsPi?-:t:t<:ms, .in',," H,",~ rh€' pennH holdey mu~)t l1oti'f;y i:h~~ f:?~Jildin"l O1'1"il;;:i<'\1 \.rhwf1 n"ady f.::w im;pec"\;i.ol1s. h1tJtl;;i} oi'tJ>~DJl,.qIN; hc,j(~/4fr--n:ld~ the- Building Offi.cial oi' n"quinxli.YlSp>"<ctio\1C3 ilray ,'e$1Jlt in fh~ "rLopp,~ge cd th(0 \~ork \ll'd:U ,,"-Jch time tJw. ~ t.hEI p<,)nni t. holdE'\" can ",.ubst.8.ntL~lb~ to t:h0 bu.ildin:;; off 1 ,;;iiiid, trnt thf~ concealiid vIO'(\" nlP..",t'3 LIt" (MC'w"~k;, ,-,Oeft." ','\"l":,'\.lincmGn;,~,s>. I'm>' d",molit.i':Xl, bOSf:i.llSh '''I" f.i.nancial buxd<frn ",hall l."~ benne dJ.'((;cU./, by r.he ~)",\'nnt holdn\\-.. "',,<ill.!''''" t.o $I.lbstantia.t.o ':::ode \'er.1I.ll'r'<::illlents \<,dU ind<."fnni:f;" thi! Cii:)' :-\::j"ti~1;,m' ;~ndRl~'~(~;':l~pt:CJ;:~1it:y c~'r(f10~: ,1;rl:;CJ\1SmGf D ~(L9~1- I r~y".bi' c"....ttr;' t.hild.. I h,lVO i'Qf;.;J '3.\'1>;.1 it>(~wlln'"d 'Hn;;-"wrnut. ",\1o.kn':'\-I t:.ro(:) '-;;'l,IYJ(c t;.:, b(,. "tr'll",' e.nd co....n;;ct. All f'\'ovi,.jcirw; of rmt7..-:::,Ylt..i m{~~'G~rn thj~"1 ,..f :;al-en:r1;e L'C~f?7~r-'/\";iJ~{hr;:r sr-'~cH;if)d hendn ny "(iO+:., fhe. sn.,:\4}1;\$; nt. ,i\ PB\'m:\:t: d,)&,,, not pn'i";""JI11,,' t.Q :;'1.1"''-' a.uthc)'(,.ty \;f) -/lol1lJ.t~' 0\' c<lnc.l'l t.h" prQV1"'\J.';.ln~; of ,111)1 otl~'1'Y 'o'h)t.., or le,cHl 18.l~ nCL1U1F.rt.in9 com..l:p.lc'~ion 01' th!i!' por'j'unnanc(,! of COI1S1;I'u.;;"\:ion, :'::::';:":~::-:::~t -::':-:rn"::"\~::, ~::~:. ~1:.:~-"..:~~.~i27{.~iA~. ~D.~~.:~.;~."~-~ :;OC':lO,'j 3, C}'l.'ilptel" 12'0, .l8,~';.f 01' 1967, :~!rl,,\r\ii _.~ . ~ \ ~ij r'(r~'itIJ Yx.~ ~ ~... ..-,..,....... "'_""'-'-'~ .,.._~.....M '._'"" .,~.",,,.... ._,,~_~...__ t ,..,".._..~_._....." ....~.....__~~.. "'V~~ ,.~O>. _. ...,.>>..-~..,,' ".....,........',.> i),;),'f:e~: ..~, ...~~. __ .. "'~ _.".,~. .......'"',~. ~ .....,._&.. o' ,.. ~. ......h~ .,.,f.~,~~ **~**~***.**************~** Perfllli. (:F;nter-..npprol,ied 8y: DatEl~ ..- ~ a Wl~fit 27 2003 J!!J BREMERTON BUlLOING OEPARTMENT ~.~ .,....-....,\-. --. . ,~ ~...,...~'.Jt~ .~ , \ ," J BREMERTON PERMIT CENTER 286 4th Street ~ Bremerton ~ WA 98337 Pho ne: (360) 478-5275 FAX: (360) 478-5278 E)l,IILDING PERMIT '\ Applicant: 1911 N CAMBRIAN AVE NORTH CAMBRIAN 3794001'-006--WOO ODct - 0003 8 J BUILDERS PO BOX 2274 8REMERTON WA 98310 373-0775 Permit No: Status: Applied: Issued: Expires: 03-0068 Pt J{ N G 02/iO/2003 Job Addr: Location: Parcel No: Owner: B J BUILDERS 373-0775 PO BOX 2274 BREMER TON WA 98310 Contractor: 8 J BUILDERS 373-0775 PO BOX 2274 BREMERTON WA 98310 Lie #: 8JBUI**227MC Exp: 10-1-2004 Subeontr: Cy~ Dese: SINGLE FAMILY RESIDENCE WITH GARAGE ****I.~~'a*~~*I***************************************1**********11*************************** Va ",:.'l-tion * Permit Fees: 983.00 Total Calculated Fee: 1> 551. 49 70, J ~.O. 40 1.< P la n C hec k-E.e..es: 513.99 Addit ional Fees: .00 * "'~----~td;~/F-e~~()3 54.50 Total Permit Fee: 1,551.49 *1***********************************************************1******************************* MECHPNICAL/PLUMBII\IG FIXTIJRES-- l"iECH-Ra.nge......... . .. .... .. .: 1 l"iECH-Gas Fumace to lOOk btu.: 1 MECH--Gas Piping (outlets)....: 3 MECH-Exhaust Fa.ns............: 3 MECH-Rallge Hood (yes)........: 1 MECH-Clothes Dyyey"..........: 1 PLBG-Wa.tey Closet............: 2 ~~~.................: 1 ,PLBG-La.vatoyy. .........."....: 2 PLBG-Showey..................: 1/' PLBG-\<,itche!\Sink............: 1 ff~:::::::~:::::::::- ~ rUG-Clothea p......./ [7:( ftr'''(J~ , .....~..~..~.:z:..*~*~.*.....~.... .............****~<********************* This p€>ymi t shall become null and void if the buildim 0'( ("oyk a.u hoYiz:ed by thi~~it is not commenced within 180 da.ys hom the da.te of such pennit. oy if this building oy woyk uthoYiz:ed ~r.d ch pey'mit is SlIspended OY' a.ba.ndoned a.t any time a.fte'( the v,loyk is commenced foy a. pedod of 180 ~_.- (~ NOTICE - It is the yesponsibility of the peymit holdey, ~ot the City of ~y ~eyton OY~'ldir~9 OffiCia.l. to !€>e to it that '(equir&d inspections aye ma.de. The peymit holdey ~$t noti.:f"'ve~ildi~9 fic \"hen yea.9'f'Jol' inspections. Fai.luye of the peymit holdey to notify the 8;Uil~fi~l f y~quiY~d' nAp ions O1a>' y&:ry i17 t.he stoppa.ge of the ,,,oyk until such time tha.t the peYm*._~tf1deY ~ SUbst~~te ~/bUilding oft\CiY . that the concea.led woyk meets oy exceeds code Yequi~emertf An>' ~molitii:!n" 't~tin'~ J financial buy~ ~hall be bome diYecUy by the pennit holde'(. Fa.iluYe}(~sub~a,ntia.te .~de YeqlJ,.\'~,!1"en\ip ~1J.1 indemnif}\th6 City aga.inst an>' a.rld a.ll yesponsibility oy lia.bility~on~ted with th, const/u~~torl'r~'J.'-' .\ '\ I hereby ~rtify thet I heva read and .lO~~d~n1. ,a,,'\i;,(J;ct ,,"'" ~.~fJ, be t>..~}d ~ct. All PYOViSIOns of la""s and oYdinances gove1('n~ t~b typer~~:wk \o.lill,\t)e {o;;!!:\trfd with ~~hey,;~:fied heyein 0'( not. The 9Ya..n.tin9 of a. p.eYmit drJe:;;'n\:.t ~SlIme to\~..~~ve a.ut.h'{0-h tifvJolate.oy can~)e pyovisions of any othey stti\O",lSC20 ~r \y~:~~~~~qp~8nd'f t~m-~~neeb5~Pttpti,~,<.... SignatUye:_._________~.~,____-___._ Date:___ I CEit >' 'that I am exempt fyom ~)y~qJj l'ements of the state contya.ctoy'S YE'slistya.tion law, undey :3ecHolj :3, ChapteY' 126, laws of 1967. I , ~~9;;~~7:)l:lK)l;;>K**)}: lK;j()I()I:)I:)I: * )1:** >K * '/_M_______.__"O______ D,i\te: :----------'~-:--"- per,mi I Cenler--Approved By' ~ e' _2.{ ?!:L(l:-l?<P': ~ . ,. <,,>'~1~~i BREMERTON PERMIT CENTER 286 4th Street~ Bremerton. WA 98337 Phone: (360) 478-5275 FAX:: (360) 478-5278 BUILDING PERMIT Applicant ~ 1911 N CAMBRIAN AVE NORTH CAMBRIAN '7J/~04001-nr\" "'-'''6 ..) 7, QO~1 ~"'\JO O()~ B J BUILDERS PO BOX 2274 BREMERTON WA 98310 373-0775 Penni t No: Status: Applied: Issued: Expires: 03-0068 PENDING 02/10/2003 Job Addr: Location: Parcel No: Owner: 8 J BUILDERS 373-0775 PO BOX 2274 BREMERTON WA ~8310 lr"" Contractor: B J BUILDERS : "'\ 373..0775 PO BOX 2274 BREMERTON WA ~18310\ Subcontr: . [lese: SINGLE Ff~MILY RESIDENCE WITH GAR~~E \ , Lie t: BJBUr*.227MC Exp: 10-1-2004 ~ , **********************.**~***********.**~'******.*****....*********************************** Valuation * Permit Fees: \ i 983.00 Total Calcu~ated Fee: 1,551.49 70,110..40 x, Plan Check Fees: 513.99 AddHio;\al Fees: .00 >I( Other Fees: 54.50 Total periilit Fee: 1.551t[49 ***~(******~*****~*)~****~*~************************~***~******.*.********~*~.************~**** MECHANICAL/PLUI'I81NG FIXTURES"- KECtt-RaT1ge...... .............: 1 ME:CH-G'.:.s Fum3ce to lOOk btu.: 1 'i, .~~ MECH-t-ias Piping (outlets)."".; 3 I'If:CI+-E){haus.t E 3 MECH-Rar\9S Hl.-.od (res)........: 1 \ MECH-clot.h,l,?$ Drys'r......."...: 1 f'lBH-t.Jatey ~loset....."..,,\..: 2 /~€tIl?........""".....: 1 pCe,G-Lavatoyy........."...".".; 2 PLBG-S .1'..,.."........"..\.: 1/' PLOO-Kit.Che.n\Sink...........,,: 1 , , \' \ PLBG-Oishwasht'Y" """ " , . " , , ...,,: 1 PLBI3-Clr1 thss Washe-r."."""""" : ):. PLBG-Water ;,t1eVlter'" . , . , "" "" . , ,,: 1 rl Bj_"""""~""..."..'_ 2 I . / I~ /1 U( 'iI' U C .....!.f;...d...L.9....[).3.i.... .LJ...*, .............................""........... This pennH afYilll bGlcoOls null and void if t I~ building 0'( work ''l' fhC1rized by th~ peY.)~ is not cOinmenced '~it.h:i,n 180 dayS from the date of ~1uch peymit. oy if this building 01' WO!'\< \.~riZ:ed I~f)~h permit is suspended or "', aoondoned a.t an)' time after th~ "lOrk is ,:;;oolfrl(/nced for's. ped,oo of' 180 ClaY$'-\J\:j I~TICE - It is t.h~ yespoTI$lbility of the peymit. ,~lder; not the ~y of JJeme;ton o~e~11&{n9 Official to $~ to it that required inspecHoris aye lI'l<ilde. The pel'mit; horc'~o: : -no~\t~Builqi~Off\;J;al when n~~ tor' :i.nspeci;iorl$. Failuye of. the permit holde~ notify t~1.6Y' . i'i'lS Of!::Jia\ o~ requ\y~ ~1'~l>Ction9 may ~~l t.- in tho !>t:oppa:;(ls 01' the \.JOyk ln~~ll SlfPt1f(rgI/that thl1\n4~~oldflt'1an $Ut>>tAf1iiClt(t~ blIildim'R,fkcytl th<'J,t th~ concealed wo'r'!( nw.eb cr ,ll,e';".;Ji:; " ~ reC1)/lp~'-oerts" A~demoliYOl\. ,\;:'es,t(rib...Jc,y financi.al ~*f shall r:x? born'3i di re,::tly by t.he pel 11 J, ~(.'{del" -ai "~. 'V{ Si:hs.tantiatf code r'e~l y~~~Lill indemni fy ,J:h~.,-b ,ty .,,'not "'/ and ~1l ,..",,,,,,bil'y 0; . obi 'y_t'" Cth 'he l",ki~ .."\ 1\ I hereb>' certify 'that I have 'read ~m~,~~?thie}::t{rW and kxx1;r}be III t.o be\t~W,ndf)oyY(?Ct. All PYCNisiol1ffi of laws and oYdi.nanc;'es 9~m\~ this t_{~~df work wiJi\ ""If. (~~~ed I.lith\~hetf,ylkecified herein 0'1' not. 'rhe gnantinSl of a. paYOli 't ~.;l\ not~ presume ~ give a~})oyitrf9 violate or c~l the provisions of ;Rny' othey ~"tate oy lo~~.\l la(("\,~f\;g\.con$truction or tr:)ver'formance of cClY1structi€""rr SignatLl '(e~ -----..----'.'...:\..::.~..-r--~--'--_..."._.~.,-.--- Date: -.---"--'--,-----,,,------,-- d:if'y that I am ()>XI?I11Pt hr.Jm-.ihe f",qUi y'ament.s of the stat.e contnilctOY'$ n~9istnation law. undeY' 'on 3, Chapter 126., law$ of 1967 = ;;;';;;;;.;'~-;;~-;;.";;;,'i;i7'-----_.--------..-.-.,-' oate~:~_____,..---_'-.~---'--'_. \z e r.... A pp r 0\1 e d 8}1: )l,_.~,...,_,_____"__. 0 ate: _,_.... ,____u<<__"_....,___ \ ) // / )~, . ~ [g ~ ~ ~ w ~ @ 03 - OO~ ? O \) (~.;- 0 . . FIB 10 2003 BBEMERTON &.-C - '-- fBUlLDINGpERMIT CENTER Department of Community Development :c 286 4th Street :c Bremerton ::. WA ::. 98337 (360) 478-5275 ::. Fax (360) 478-5278 Building Permit Application APPLICANT: ~ OWNER 0 CONTRACTOR 0 AUTHORIZED AG~~Aq ._ 0 DO;> v...... 4 Tax Accqunt Number: 3/} -17&/-:- ~ tJ3 OWNER Name: f!>IfJ4ttJ ::rfko&iOIt/ Address: f-Ul5rJr. >>-~) City, State, Zip &r6fY1~(7P/ 4/1- 7'G3Li2. Phone #: (3 C;tl) 3.?3~..r :3 Contact Name: City, State, Zip Contact Phone #: ( Phone #: ( ... Check the type of application for below: ir a c V G4.1/tt~ /aA.~ ~. NEW SINGLE-FAMILY RESIDENCE D NEW COMMERCIAL I D NEW GARAG~/CAR PORT ' o NEW DUPLEX D COMMERCIAL REMODEL D NEW ACCESSORY SLDG . D NEW MANUFACTURED HOME D COMMERCIAL ADDITION D NEW SIGN D RESIDENTIAL REMODEL D COMMERCIAL REPAIR D STRUCTURE DEMOLITION D RESIDENTIAL ADDITION D NEW MULTI-FAMILY D GRADING (Cubic yards: -) D RESIDENTIAL REPAIR D TENANT IMPROVEMENT D OTHER IS THIS PROPERTY WITHIN 200 FEET OF A SHORELINE? YES D NO ~ Scope of Work Proposed: SFI?- u/ ~tfj(~~ ( Square Footage: Dwelling: //.20 , Garage: <t tjtJ Decks: c: 'Y Valuation Plan Review Fee Permit Fee SurcharQe Total Fees JOt (loRO ~r)iq, 79b.7j/ . - 0 I 3"5/. i ell 4i.J. 00 . I flf."Z-'>. Application for which no permit is issued within 180 days following the date of ap.RtJcat~shall expire by limitation, and plans and other data submitted for review may thereafter be returned to the applii'ai~t or destroyed by the building official. The building official may extend the time for action by the applicant for a period not exceeding 180 days on request by the applicant showing the circumstances beyond the control of the applicant have prevented action from being taken. No applicant shall be extended more than once. In order to renew action on an application after expiration, the applicant ,hall ,e"bmll plan, and pay a new plan 'e~l!e. APPLICANTS SIGNATURE: ~~ DATE: ';~/t?-(JJ \~ fFQ~ 03-00G~ ADDRESS FORM (360) 478-5270, FAX (360) 478-5398 APPLICANT INFORMATION +NEWADDRESS _ CHANGE ADDRESS DATE: ;L-ltJ NAME: ~If.J4ttJ -JfJr-<:.gg.>tJ'; PHONE: :?73 -tJ7?& ADDRESS: f. 0f3{)1 ..2,;2.. 7'-1 FAX: S/f1Y1<<- CITY/STATE/ZIP: ~1(~'G,f7{);J {,;A-. C)#3ltJ KITSAP COUNTY PROPERTY 1.0. NO. (FO~ LOT TO BE ADDRESSED): :3 /7'<T ....0&1- oct - Cl-S PLEASE DRAW A DIAGRAM OF YOUR PROPERTY. INCLUDING ADDRESSES OF NEIGHBORS. DRAW DRIVEWAY LOCATION AND SHOW STREET NAME THAT DRIVEWAY ACCESSES. INDICATE WHICH DIRECTION IS NORTH. sefi /l-1T1LH6D CITY USE ONLY. DO NOT WRITE BELOW THIS LINE. NEW ADDRESS: / q / / ZIP CODE/kJ}5-j-tlff';ce /Il? . r/llJ1 .!J /1/ a 11 Ii ve 17/.:t.-f? APPROVED BYI DATE: ,j';1!/J / ~// 1./03 Revised 12/28/99 1 , ;) ,Loo " VICINITY MAP ''''iD~Z)-I-l E.- s~f:t1r-1!r>:;,~iEE. - ~ ~ I~'i " ~~ I', . ~ ~~ \i \ , I \ ,: '1 it' ~ . -.... ~ ~ ~ -+ ~~ ~ ~ ~ '"' ,..- ...j'J f ~_LA-W. ~ C! -=-..c!l... fD) ~ CG ~ D w ~Jj)). Ul) f- JHE(iMJT~ENTER BREMERTON BUILDING DEPARTMENT Department of Community Development ::- 286 4th Street ::. Bremerton ::- WA ::- 98337 (360) 478-5275 ::- Fax (360) 478-5278 PLUMBING MECHANICAL 00 I ~ I Type of Fuel: Occupancy: o Electric }XI Residential [Xl Gas o Commercial D Oil D Propane Site Address: CONTRACTORSJ BIJ/l."f)iiR J Address: f,1J,fiO;( ~ ''-1 City, State, Zip:p,p "" 4",;97/",7 D E/r)fi ' 1) tv,. / "oJ. v License # & Exp. Date:B'J WI).:).? frJt... Contact Phone #: (j/;O) 3?J -t7?).J OWNER: Address: City, State, Zip: Phone #: NO. TYPE OF EQUIPMENT NO. TYPE OF FIXTURE /1 / RANGE (;:JuS :l WATER CLOSET . WOOD/PELLET STOVE/GAS FIREPLACE BATHTUB / / GAS FURNACE btu ~ LAVATORY (BATH SINK) CONVERSION BURNER: btu I SHOWER UNIT HEATER btu i KITCHEN SINK BOILER btu I DISHWASHER ~5 GAS PIPING LAUNDRY TRAY EVAPORATION COOLERS btu I CLOTHES WASHER ..... AC UNIT btu I WATER HEATER (:;; C; \" HEAT PUMP btu URINAL '- REHEAT BOX btu: DRINKING FOUNTAIN ~ EXHAUST FANS FLOOR SINK OR DRAIN I RANGE HOOD (RESIDEN~IAL) ~ WATER PIPING & ALTERATION . . RANGE HOOD (COMMERCIAL) GREASE TRAP/INTERCEPTOR J CLOTHES DRYER ~ HOSE BIBBS INCINERATOR LAWN SPRINKLER SYSTEM DUCT ALTERATION SWIMMING POOL TANK TYPE: BLDG. SEWER: (MOBIUMOVED HOME) REFRIGERATION UNIT ROOF DRAINS OTHER: OTHER: -2. -/V-6B Ap~'S Signature Date *********************************~****************************** RECEIPT **************************************************************** RECEIPT Number: 03000106 Amount: 513.99 02/10/03 11:32 Payment Method: CHECK Natation: BJ BUILDERS Init: PC PenTI.\. t r'~o: 1._()cat..ion: 03,-0068 '~r Yf;'(~ ~ BLDG BLOG PERMIl W/MECH/P 1'>40F<TH CAI"Il3F; I r~f'4 Total Fees: 1.551.49 This Payment 513.99 Total ALL Pmts: 513.99 Balance: 1,037.50 **************************************************************** i'iCCOUflt Code Oe~~;Ci ir;:rti.on (~rnount 1~,'<VI!5. (3:300 (4 ::>80) BUILDING PLAN CHECI( FEES 513" 99 ,....) fyu" OW) J101 I rzJ~K' . I I ~ f((JA1j J;AJ;f I d:i~I1% M 0 Ct/A1 ~ U' - ~~ llJ BREMERTON PERMIT CENTER 286 4th Street, Bremerton, WA 98337 Phone: (360) 478-5275 FAX: (360) 478-5278 BUILDING PERMIT Job Addr: 1911 N CAMBRIAN AVE Location: Parcel No: 3794001-009-0003 Permit No:. 03-0068 Status: ISSUED Applied: 02/10/2003 Issued: 03/05/2003 Expires: 09/01/2003 Applicant: B J BUILDERS 373-0775 PO BOX 2274 BREMERTON WA 98310 Owner: B J BUILDERS 373-0775 PO BOX 2274 BREMERTON WA 98310 Contractor: B J BUILDERS 373-0775 PO BOX 2274 8REMERTON WA 98310 Lic I: BJBUI**227MC Exp: 10-1-2004 Subcontr: Oasc: SINGLE FAMILY RESIDENCE WITH GARAGE ***~;***************************************************************************************** Valuation * Permit Fees: 983.00 Total Calculated Fee: 1,551.49 70,110.40 * Plan Check Fees: 513.99 Additional Fees: .00 * Other Fees: 54.50 Total Permit Fee: 1,551.49 ********************************************************************************************* t4ECHANICf~L/PLUI4BING Fn<TUf~ES'-- MECH-Range..... . "............: 1 MECH--Gas Fuynace to look btu.: 1 MECH-Ga~" Piping (outhltS)..,.: 3 MECH-Exhaust Fans..."".......: 3 MECH-Range Hood (yes)........: 1 MECH-Clothes I)yyey...........: 1 PLBG-'^,atey CloseL...........: 2 PLBG-Bathtub.................: 1 PU3G-LavatoY}'................: 2 PLSG"-Showey..................: 1 PU'lG-KHchen Sink............: 1 PLBG-Oishwashey. . . . . . . . . . . . . . : 1 PLBG-Clothes Wa'ShlYr..........: 1 PLBG--\,Jatey Heatey...........,,: 1 PLBG-Hose 8ibbs........."....: 2 ******~***********************************************1************************************** This pe.rmH shall b(~come null and void if the building 01' "-u;:Jyk authodzed by this permit is not commenced within 180 days h'om the' date of such pe'rmi t. 01' if this building ()y work authorized by such pe'r.mH is suspended 01' abandoned at any time after' the ~,!oyk is cOfl'ltTIenced foy <3. period of 180 da>'s. NOTICE - It is the yesponsibili t>' of the p(1YmH holdey, not the City of ByetTIeyton 01' Building Official to see to it that n~qui yed inspections a YO tTIade. The peYtTli t holder' must notify the Buildi n9 Official when yeady foy inspections. Failu1'e (If the per'rnit holdey to notify the Building Official of r'equi yed inspections may 1'esul t in the ~)topp~,ge of the woyk until such time that the peymit holdey can substantiate to the building official th,nt the! concealed l,Joyk meets or. exceeds code n;>quir-ements. Any detTIolition. testing, or. financial bUYden shall be boyne eli yectly by the peymit holdey. Failuye to substantiate cod,~ yequi yements "-'ill indemnify the City against any and all yesponsibilit>' or' liabilit>' connected with the const'(uction. I he'reby certify that I ha.ve yead s.nd examined this pennit and knoleJ t.he same to be tnle and coyyect. All pyovisions of laws and ordinances govenling this type of (.!oyk l-Jill be complied with l<J~theY specified heyein 01' not. The 9ya.nting of ' pe1'mi t does \ll:Jt p r-esume to 9i ve a.uthod ty to violate 01' Ciil.nce 1 the p yovisions of any c:d.;her. state (it' l(1ca. 1a r-egulating constyuction 01' the peyfonnance of constyuction. Date: __~-=:d3... I ceytHy that 1 &.rn exempt fyom the r'equiYements of the state contYactor"s )'egistYation law. under. Section 3, Chaptey 126, laws of 1967. :~g\j(n:;~Y::;_;_;;;;;****:~.**;**.;:-__. h7"'\- o.t.,~s=- OZ-- Permlt Center--Approved BYr~ Date'____~__y --,.. \~.~ ~_ R.";,:~' ~.,~\" i';:;;\~f{~i,;J!~lt'n~ijl:' -.~;, t't~..\:..j'-'~i.r '" . .." ,. .... BREMERTON PERMIT CENTER 286 4 th St r eet~.' _ EiJ,:r:~mer.t<ifrh, WA 98.337 Phone: (360) 478-5275 FAX: (360) 478-5278 Job Address: 1911 N CAMBRIAN AVE Location: Assr Acct No: 3794001-009-0003 Building Permit N6: 03-0068 Status: ISSUED Issued: 03/05/2003 Expires: 09/01/2093 Item: Item: Item: Item: ltern: I tefn : It'errl: Item: Item: Item: Item: Item: 01.100 01200 01.400 01.500 01.600 01700 01800 01900 02200 02250 02300 02700 R E QUI RED INS P E C T ION S FOUNDATION-FOOTINGS FOUNDA T I ON-l~IALLS 1'1ECHANICAL PLUMBING GROUNDWORK PLUMBING ROUGH-IN FRA~lING INSULJiTION SHEETROCK NAILING PUBLIC RIGHT-OF-WAY DRIVEl-UiY SEWER LATERAL FINAl_ ---BLDG Dept: Dept: Dept: Dept: Dept: Dept: Dept: Dept: Dept: Dept: Dept: Dept: 8LDG 8LDG BLDG SLDG SLOG SLDG SLDG SLOG PUBWORKS PU8WORKS PU8WORKS SLDG Division: Division: Division: Division: Division: Division: Division: Division: Division: Division: Division: Division: ******************************************************************************~** TESTING: Must be recognized by the Washington Association of Building Officibls SPECINSP: Must be registered with the State of WA ST OF WA: State of WA Dept. of Labor and Industries HEALTH: Bremerton/Kitsap Health District 478-'4921 478-5235 . ',ii'-: -,I I, ALL INSPECTIONS PERFORMED BY THE CITY OF BREMERTON MUST BE SCHEDULED THROUGH~THE , PERM I:f' ,CENTEf\. (360 k ':"2',8-7275. _ * * * * * * (~* ,:: * * * * * * *:15 *,}'f.~ :1~~ '~oJ':.* * * *** * * *** * *** ** * * * * * * * * * * * * * * * * * **** * * * * * * *** * * ** * * ** * Permit '-,ldEn-'s ~'. t.;, ~ ~.- .;;> r 3 ~ -~'"J ' S i g na tu e' _.__.f~,.~:t!:c:":::"~~.~~,__~Z_.___~_.___.m'_~.__ Da te : ..- J ) L,y;(:~ '. /4'/ -C' , --C-'::;1 /'(~_ .../t11' /~ ~:.F ~~-----,...... . -f'~., ...J . -":..,"" J".fJl:'~.!;;t:J:.::"Q~~~1lI,:,~'.n."' ;"".~-, ''', ~==~=,~~========F~=========================================================== ~.., ...,.. - BREtJjERJo.f>I -P:~RMll,~iPE~jTER PERMIT-~ONDITtbN~ , Permit No: 03-0068 Page: 1 ====~=~==~~=~==~=~~~~=~~~====~~~=~~=~~===~==~=~=~~==~===~=~==~~~=~~~====~===~== Job Address: 1911 N CAMBRIAN AVE Assr Acct No: 3794001-009-0003 Location: Applied: 02/10/2003 Approved: 03/05/2003 Issued: 03/05/2003 Applicant: B J BUILDERS Owner: B J BUILDERS Contractor: B J BUILDERS Description: SINGLE FAMILY RESIDENCE WITH GARAGE NEW SINGLE FAMILY RESIDENCE W/GARAGE Conditions: 1 . ENGINEERING 1. UTILITY FEES AND ASSESSMENTS SHALL BE PAID PRIOR TO FIN{iL APPROVAL. 2. RIGHT-OF-WAY PERMIT REQUIRED PRIOR TO ISSUANCE OF BLDG PER~IT (R-O-W PERMIT # 4426 ISSUED 2-25-03) 2. PRIOR TO PERFORMING ANY RENOVATION OR DEMOLITION WORK, PUGET SOUND CLEAN AIR AGENCY (CLEAN AIR AGENCY) AND WASHINGTON DEPARTMENT OF LABOR AND INDUSTRIES (L&I) REGULATIONS REQUIRE AN ASBESTOS SURVEY BE PERFORMED TO DETERMINE WHETHER THERE ARE ASBESTOS-CONTAINING MATERIALS IN THE WORK ARE~.OR STRUCTURE. THE ASBESTOS SURVEY MUST BE CONDUCTEDEr(~:i~.~~ '-EfA CERTIF-n::D (FiHERA) BUILDING INSPECTOR (EXCEPT REKI0Vlt:Tl0NAJF mJNER--OCCUP lED SINGLE: FAMILY RES I DENCES}; -, .,,~-"-C;:2f?;7 ~'7 ~. '.. /Yt.!<'::'-' ;:.~.'-.:"'" ./' t,;l< FOR ti0RE INFOF~MATION l~~'p;1..ttl''f.$E- CONTACT CL.EAN AIF~ AGENCY THROUGH THE I R WEf3 SITE A"f'" v"dJ.':~cl,~a na i r . or 9 OR BY PHONE AT 800-552-3565 OF~ 206"'689-4058. -l'HE'''':L'9Vr~,WEB SITE CAN BE FOUND AT 1.'-J~'J~\1.1 1'11 . wa . gov/wisha/f?-:.ts/asbe'st'~'<asbestos . htrn . 3. LAND USE CONDITIONS/COMMENTS: ) OK TO ISSUE ONCE THE PROOF OF NEW OWNERSH~DI7 ~S JROVIDED TO I THE CITY OF EIRaiERTON. ([),IL--. ~UJ (()(.-f f' 3 - :3 -o314J "'I'i'.':1 .\ \ . \\ ! ' , '."'. D ate _ ~.:- %=~::!.____~_ [pi]~J! BUILDING PLAN REVIEW F r i..i' '7 ,,: 'i3 ....u t.' G Celli Building and Planning Department * Bremerton * W A * 98337 Robert Doobovsky .:. (360) 478-5286 .:. Fax (360) 478-5278 E-mail .:. Doobovskv@ci.bremerton.wa.\ls Applicant: BJ. Builders Job Address: 1911 N Cambrian AVE Date: February 20,2003 Permit # 03-0068 .. ,~ PLAN REVIEW APPROVED WITH THE FOLLOWING CONDITIONS . Smoke Alarms will need to be interconnected 110-volt with battery backu ~~t.Rl ON BlJ;;.... " One in each bedroom, adjacent hall and on every floor. (UBC-31 0.9 ~~ 1/b~ . CFM fan rating ~ APPROVED ~ o Bath and laundry room fans 50 CFM ~ <: o Range hood 100 CFM 5 fE~2 2003: o Hole house fans (2 bedroom 50-75)(3 bedroom 80 -120)(4 bedroom / . 100-150)(5 bedroom 150-180) ~ . 1st floor foundation shall be 12" below undisturbed soil (UBC-1806) - . 2nd floor foundation shall be ,18" below undisturbed soil (UBC-1806) 0 _ . The ground under the floor may be excavated to the top of the footing and no ' lower (UBC- 1806) . Insulation requirements (over 12% Glazing) o Walls R-21 2x6 construction o Ceiling R-38 o Vaulted Ceiling R-30 2x12 construction 2" air space above insulation o Floor R-30 o Concrete floor R-10 perimeter insulation . All Building shall conform to the 1997 Uniform Building Code, 2000 Uniform Plumbing Code, 1997 Uniform Mechanical Code, 2001 Washington State Energy Code BUILDING PLAN REVIEW APPROVAL ONLY. OTHER CITY DEPARTMENTS ARE REVIEWING YOUR APPLICATION. YOU WILL BE NOTIFIED BY THIS DEPARTMENT WHEN THE APPROVAL OR DISAPPROVAL DECISION HAS BEEN MADE fifi. A/Jcv./ Ie / /Jt'; (J., 8~d understand the above comments. . Applicant signature ~ d- - Ci- l - D.3 ~ Robert Doobovsky Building Inspector / Plans Examiner ''\-~. '. \ .- , Prescriptive Approach - Simple Form For the Washington State Energy Code (2001 Edition) Climate Zone 1 Site Information BUildi.ng Depart.:en, U~}o/ Permit#: 0 ~ 66 D___ Lot: Address:l~lL Cji mbU/LLfl__ . -..... - ....) City: ~lfefY)!!tf"r~_________ State: _i1/~_ Zip: _!1fj31P_____ Contact: _ D~J q ttJ __S~(3Y{) ~______ Phone: 37) -cl77s Notes: n ...: n r,::J 0______ _ (QL~_(Q; ~ W If; \\\\~_____ \'0\ fEB 10 2003 ~ . ----yl:i----------- BREMERTON _ _~".,",T~RI:~___ aUILUII'lU ut:rru.....--- Phone 2: ~ 31'-:J/?~~_______ Fax: 3?3-C??j,)- Table 6-1 PRESCRIPTIVE REQUIREMENTS 0,1 FOR GROUP R OCCUPANCY CLIMATE WNE 1 (Unlimited Glazing Option Only) Glazing Glazing U-Factor Door" Wall Wall Wall Slab' Option Area 10 U- Ceiling2 Vaulted Above Int4 &14 Floo~ On % of Floor Vertical Overhead II factor Ceiling3 Grade Below Below Grade Grade Grade III Unlimited Group R-3 0.40 0.58 0.20 R-38 R-30 R-21 R-21 R-IO R-30 R-1O Occupancy On Iv See the code text for footnote references This project complies with the following: ../ The project is a single family residence or duplex. ../ The project is wood frame OR all of the insulation is interior or exterior of the framing. ../ All building components meet the requirements listed in Table 6-1., Option III. ../ The project will meet all other provisions of the WSEC and VIAQ. . The project will take advantage of the following exceptions to the prescriptive option: ~ 602.6 Exception 1. One door, that is 24 ft.2 or less, that does not meet the standards is allowed. Location of the door taking this exception __Et5JlLtIJ JJ OO~_____________ o 602.6 Exception 2. Doors with a U-factor of OAO allowed without calculations, Option III only. Location of the door(s) taking this exception _____________________________ Copyright 2002, WSUCEEP02-056 Copied by permission from the Washington State University Cooperative Extension Energy Program Prescriptive - Simple Form - Climate Zone 1 5/31/2002 r:':' ~ ,.i~ COOPERATIVE EXTENSION WASHINGTON STATE UNIVERSITY U ENERGY PROGRAM Washington State Energy Code Changes Climate Zone 1 The Washinl-,>ton State Building Code Council approved energy code amendments that simplify the residential code, and increase the efficiency of residential structures and non-residential BV AC equipment. The new requirements go into effect July 1, 2002. Following is a short summary of the code changes and resources for more detail on the energy code. Non-Residential Energy Code Changes Changes to the non-residential sections of the code focus on I-IV AC equipment. The Council adopted new equipment efficiency requirements equivalent to the ASHRAE 90.1, 1999 standard. This increases efficiency requirements for many types of large equipment. This is a significant change, with potential impact on equipment in your inventory. Compare the efficiency ratings of your equipmem with the revised code. Standards for economizers were also updated. This includes the elimination of an exception for data centers, as well as detailed instruction on the use of water-side eco\!omizers and systl:ms with humidification. Other changes include air intake and exhaust dampers, and pool heater efficiency. Residential Energy Code Changes Changes to the residential sections of the energy code include: .:. An increase of insulation and glazing requirements for the building envelope for homes previously built to the "other fuels" path. .:. Adoption of prescriptive paths with unlimited glazing. Most of the code changes for Climate Zone 1 can be summarized in new prescriptive table 6-1 (on the back of this announcement.) It is likely that most single family and duplex builders will adopt one of the prescriptive methods, Component performance and systems analysis approaches will stiil be available, and will be used to show compliance for more complex projects. Note that these approaches stiildistinguish between fuel types. The new unlimited glazing method provides increased design flexibility. Previously, homes with more than average glazing areas were required to perform component performance trade-~ffs,or a full systems analysis to document code compliance. With an easily applied unlimited glazing method, this will no longer be the case. It also simplifies compliance of additions to existing homes. What will happen to WATTSUN The Washington State I ~nergy Program (WSU) will be discontinuing the publication of W A rrSUN as ofJ une 1, 2002. WSU developed a free worksheet that allows for component performance tradeoffs. The worksheet is available in I.:xcel spreadsheet format and located on the WSU code support website (see below). For More Information Your primary source of code support is the \X1SLl Energy Program code support website: http://wuiw.energy.wsu.edu /buildings. The website contains downloadable versions of the cnerl-,,!' and ventilation codes, forms for prescriptive and component performance compliance, information on training, and the Builder's held Guide. To order printed copies of all Washington State huilding codes, contact the Washington Association of Building ()fficials at HHH-M4-9515, or online at http://www.wabo.org. For non-residential energy code support, visit the Northwest I':nerl-,'!' J':Hiciency Council website: http://www.nccc.nct/ TABLE 6-1 Prescriptive requirementsO,l for Group R Occupancy (regardless of heat source) Climate Zone 1 Glazing ArealO: % of Floor 1. 12% II. * 15% DIl. Unlimited Group R-3 .~cc~~~~ _ Glazing U-Factor Door9 U- Factor Ceiling2 Vaulted Walll Ceiling3 Above Grade Option Vertical Overheadl 0:58 0.58 0.58 Reference Case O. Nominal R-values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. 1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing option (or. higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings. 'Adv' denotes Advanced Framed Ceiling. 3. Requirement applicable only to single rafter or joist vaulted ceilings. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. lnt. denotes standard framing 16 inches on center with headers insulated with a minimum of R-5 insulation. 8. This wall insulation requirement denotesR~19 wall cavity insulation plus R~5 foam sheathing. 9. Doors, including all fire doors, shall be assigned default U-factors from Table 10-6C. 10. Where a maximum glazing area is listed, the total glazing area (combined vertical plus overhead) as a percent of gross conditioned floor area shall be less than or equal to that value. Overhead glazing with U- factor of U=OAO or less is not included.inglazing area limitations. 11. Overhead glazing sha\lhave U-factors determined in accordance with NFRC 100 or as specified in Section 502.1.5. 12. Log and solid timber walls with a minimum average thickness of 3.5" are exempt from this insulation requirement. I"umlt:d by: United Stilte, Department of !':neq.,'J' NORTHWEST ENERGY EFFICIENCY ALLIANCE www.nwallianee.org @ 2002 Washington State University Cooperative Extension Energy Program. This publication contains material written and produced for public distribution. You may reprint this written material, provided you do not use it to endorse a commercial product. Please reference by title and credit Washington State University Cooperative Extension Energy Program. Published June 2002. WSUCEEP2002038 .. ,. , .~. . ... ""2:. \\ ~ 3> OJ .~ ...... ~ 1:7 "- ~ ~0 ...c:. ~ - j\/ J cb- ~ \" --t- ~, - <\" rr~,\ ('1- ~ t,.<' ~ 0:1:" [@ .~ ~ ':": ~, ~~ ~, ~~ ~ ,~,. ~. '. ~ rn'ri\ .- ubU ~! ~I r~~ ~- ----S\ C? ~~ ~~ -~ - ~ . 1 ~ ~ r- I I I I I I I i I I I I ! <::' ~ "- .... , \ I ~ , <:t ~ V\; nil' C. \\'\ ~ 2.2 ..... ~.. _n_~J ~ ~ ~. ~ \~ .___._____~_Lh~r:(' --.-._-- ~ n__ ! i i ~. ~. "1' ~.. 'i - "~----'"T ~, ~ .;.) ~ \\i\ \ (---... . \J \' 0) D ~ ~ ~ ~ ~ > V ~ \ " 7; i i I~ ~ 10-: I ~ --_._,--- _n_ ~ ~ /~ . ..~ 93~ aChe: 1O)~~~OIW[gfnl Inl ~tB 1 OHI',~IT CENTER L-J BREMERTON BUILDING DEPARTMENT Department of Community Development ::.286 4th Street ::. Bremerton ::. WA ::. 98337 (360) 478-5275 ::. Fax (360) 478-5278 RESIDENTIAL SITE PLAN REVIEW QUESTIONNAIRE Pem1it applications are reviewed by our staff to make a preliminary determination of the presence or absence of unique areas on the property. To help us make this determination, please supply the following information with a scaled and dimensioned site Ian. Applicant: 61fJ4rtJ :5JI)LtlfjJ(I}I/ Description of Proposal: jtJ~1r./ 65 /J(jJ L.O~^-S sr~ Street Address (or street name if no address has been assigned): Tax Account Number: 37 -(JtJI (}'3 ooq ---00.0;:' . 1Y}1Jf? ,/Jp NP ("iT /It? F 111 Critical Area Questionnaire: 1. Is there any standing or running water on the surface of the site at ANY time during the year? If YES, please describe conditions: DYES [)( NO 2. Are there wet areas on the site? lfYES, please describe: D YES )a NO 3. Is the site characterized as: D Forest . Cleared D Developed 4. Please give the overall slope of the parcell..lL..% and the slope at the building site _ %. 5. Is the property within 200 feet of a shoreline? D \'ES NO 6. Will the proposed structure be aesthetically or functionally disruptive to surrounding properties, the neighborhood or the community? DYES ~ NO See diagram explaining the slope calculation on the back. The applicant hereby certifies that all of the above statements and the information contained in any other transmittals made herewith are true, and the applicant acknowledges that any action taken by the City of Bremerton based in whole or in part on this application may be reversed if it develops that any such statement or other information contained herein is false. ~-IcJ~3 Date Site Development Figures Percent Slope Calculation Slope is calculated by dividing the vertical distance by the horizontal distcmce, then multiplying the result by 100. Example: Vertical Distance of 20 feet Horizontal Distance of 100 feet = .2 x 100 = 20% slope Ii~'\ 60~l ~ n/' ~~ V 0" 30o/jD~) ~ ~, " ~ 15%,fY~\ ~ ~~ ~ o .::1 1 -~ .'-' V'~;'1\ j \ -' CJ~F Residential Site Plan Review Questionnaire Page 2 I ,. " .. r. ~~\. (;'. (I~~. r\ ~..n r@ ~. " 'l . . ... , , 1._, L! '\:./ L~ \'1 ,j ~""'-... t~l{ .' , ~ :1 'll,jU'j · ~ U .' ,: ~~ 1 0 g,u oJ BREMERTON IBU1LDlNG DEPARTMmT STRUCTURAL CALCULATION OF GARAGE SHEAR WALLS ADJACENT TO GARAGE DOOR Project Name: B.J. BUILDER Property Address: 1911 N. Cambrian Ave Bremerton, Washington ~7....~n~'... .... U" ~i,:r~"' I , , . .' -', JOB NO. 07BJ022003 (:,..;~~$~f>t':~~~~'~l,r (;or,"'!"" \' WA.......I1/. '\'1 Matthew Gunawan, MSCE, PEV/"':.0'; >:~'::J"i--o~' {';:} c~7 ~;:./~~f;,~ f ~. ~ . ~ .p l> "'''''''~~ .r ,..: ;, ~.A l . f,;~ -;r.. I. ),,- \> KITSAP CONSULTING ENGINEER, Inc~~.""1L.....j, ,- D~~l~l 7008 Osprey Clrcle\~1-'% ",(102'36' ~l;- J! Bremerton, WA 98312 ~i5'.'(1,+~~1JSr~~~.AI,f(,.fi ":I"l_~...-"- :\ l-' Phone 360- 4794423 I . NAL~ ,;" Fax 360- 479 4424 _ J E-mail: kcc-"a:ilJ~Il1<:G\ml ~~ b~ 'Uv / @ATI/'JI.ccM ( STRUCTURAL CALCULATIONS AND DRAWINGS SHALL BE USED FOR ONE~ CONSTRUCTION ON THE ADDRESS SHOWN. ~ TABLE OF CONTENT PAGE Building material self-weight 1 - 2 . Lateral force calculation (Wind and Seismic) & diaphragm rotation 3-5 Reference: Uniform Building Code 1997 Design Assumption: Roof dead load = 17 PSF Rooflive load = 20 PSF (minimum) Snow load = 25 PSF Exterior wall dead load = 12 PSF Interior wall dead load = 9 PSF Seismic = Zone 3, Site: SO, I: 1.0 Wind = 80 MPH, exposure: B, 1w:1.0 .// STRUCTURAL CALCULATIONS AND DRAWINGS SHALL BE USED FOR ONE ~ CONSTRUCTION ON THE ADDRESS SHOWN. ~ 07BJ022003 SELFWEIGHT.xls ROOF :DEAD + LIVE JOB LOCATION: 1911 N CAMBRIAN AVE, BREMEfHON, WA ROOF I.D. : ROOF __~----T 600 12.00 (harz distance) Matthew G 2/14/03 l/,. { ":. Roof Slope adjustment = 1.12 Ceiling Slope Adjustment = 1.00 Default Selected Slope Adjusted NOTE: Material Weight Weight Adjustment Weight (psf) , (uno) (psf) (Y or N) (psf) ROOFING metal 20 GA 1.80 wood shingle 2.00 asphalt shingle 3.00 3.00 y 3.35 clay tile shingle 11.50 5 ply felt & Qravel .6.50 C) FELT ~!sq. 0.30 0.30 y 0.34 Z SHEATHING 1/Z' plywood or OSB 1.50 1.50 y 1.68 - 1-1/Z' decking 4.50 U. FRAMING 2><4 @24"OC 0.70 1.40 y 1.57 TRUSS TOP CHORD 0 0 2><6 @24"OC 1.10 a::: 2x8 @24"OC 1.50 2><10 @24"OC 1.00 2><12 @24"OC 2.20 INSULATION R 11 glass wool 0.70 (roll! batt) R19 glass wool 1.10 R30 glass wool 1.80 R38 glass wool 2.20 6.~ FRAMING 2><4 @24"OC 0.70 1.05 1.a5 TRUSS BOT CHORD 2><6 @24"OC 1.10 2x8 @24"OC 1.50 2><10 @24"OC 1.00 2><12 ta>.24"OC 2.20 INSULATION R11 glass wool 0.70 (roll! batt) R 19 glass wool 1.10 R30 glass wool 1.80 C) R38 glass wool 2.20 Z CEILING acoustical fiber tile 1.00 ..J suspension - metal frmg 1.80 suspension - wood frmg 2.50 W 1/Z' GWB 2.20 () 518" GWB 2.80 2.80 2.80 plaster (1 ") 8.00 SPRINKLER 1" I2l wet (PLF) 2.10 schdl40 2" I2l wet (PLF) 5.20 3" "wet (PLF) 10.80 4" "wet (PLF) 16.40 0' "wet (PLF) 31.70 8" "wet (PLFl 50.80 MISCELLANEOUS basic -min. 1.50 2.00 Y 2.00 5.851 12.05 ROOF SNOW Basic (x 1.1& IF>300PERSON) 25.00 25.00 N 25.00 Drift ( include Basic) 35.00 N W Sliding (include Basic+Drift 40.00 N > ROOF MIN. LIVE 1997 UBC tab 16-C 20.00 N - ..J l::>.WI CEILING . 10.001 N CEILING OVER STAGE 20.001 N J 25.00 D(rf) 6.93 (pst) D(cl) 5.85 (pst) D(rf) + D(cl) 12.78 '~st) . KITSAP CONSULTING ENGINEER 300-479-4423- U.s.e Ii D(rf) + D(cl) + L(rf) D(rf) + D(cl) + L(rf&cl) 37.78 (pst) min 37.78 (pst) max I'f, F 1 OF 1 ~/( 07BJ022003 SELFWEIGHT.xls Matthew G 2/14/03 WALL DEAD LOAD JOB LOCATION: 1911 N CAMBRIAN AVE, BREMERTON, WA WALL HEIGHT: 9 (ft) STUD SPACING: 16 (in) Default Adjusted Selected NOTE: Material Weight Weight Weight (PLF) , (uno) (PSF) (PSF) FRAMING top plate - dbl 2 x 41 ft 2.80 0.31 DOUGLAS- top plate - dbl 2 x 6 I ft 4.40 0.49 0.49 FIR top plate - dbl 2 x 8 I ft 5.80 0.64 stud-2x4/ft 1.40 1.05 stud-2x6/ft 2.20 1.65 1.65 stud - 2x8/ft 2.00 2.18 bot (sole) plate - 2 x 41 ft 1.40 0.16 bot (sole) plate - 2 x 61 ft 2.20 0.24 0.24 bot (sole) plate - 2 x 81 ft 2.00 0.32 bot (sole) plate - 4 x 61 ft 5.20 0.58 bot (sole) plate - 4 x 8 1ft 6.80 0.76 ICF 4"(4) eone wall 50.00 6' [6 1/4) cone wall 78.13 -I 8" [7 718) cone wall 98.44 -I <C 10' [9 718) eone wall 123.44 3: INSULATION R11 glass wool 0.70 (roll I batt) R19 glass wool 1.10 1.10 rigid insulation 5.5" thiek (ICF) 1.65 SHEATHING exterior - 112" ply 1.70 1.70 exterior - 518" ply 2.00 exterior - 518" GWB (fire) 2.80 interior - 112" GWB 2.20 2.20 interior - 518" GWB 2.80 FINISHING finish ext - wood siding 2.50 2.50 finish ex! - gypsum plaster (1") 8.00 finish ex! - solid plaster (1 ") 10.00 finish ex! - clay brick (4") 35.00 MISCELLANEOUS basic -min. 1.00 1.00 others 2.00 Weight per square foot of wall Weight per linear foot of wall 10.88 ~ k-$-c \\... \'5,f- 97.95 (pit) KITSAP CONSULTING ENGINEER 360-479-4423 10F1 07BJ022003 Shear Wall 1997.xls SHEAR WALL CALCULATION Matthew G 2/14/03 ':;/<; BUILDING IDENTIFICATION 1911 N CAMBRIAN AVE Note: For the purpose of this calculation - . the NORTH direction will be assume in the direction from the BOTTOM to the TOP of the DRAWING PAGE. Loading - per use 1997 SEISMIC FORCE EIG <-- Base on lump sum weight (ft ) 9.00 <- Base on diaph height 0.00 <-- Base on diaph height sum(weight) 14.3 18.8 I Ie 0.30 I Ie 1.00 IL PROFILE c SO Rc 5.50 Ca= 0.36 Cv= 0.54 Na = 1.00 Nv= 1.00 Gt= 0.020 hniroofl = 9.00 WIND FORCE PROJECTED AREA METHOD WIND SPEED = EXPOSURE = IMPORTANT FACTOR = 80 [ mph ] B 1 WINDWARD LEEWARD TOTAL HEIGH Ce 0 I ('.on Pins! Co PI",,! P~ 30-40 0.84 16.40 1.0 0.80 11.0 0.50 6.8 17.91 25-30 0.76 16.40 1.0 0.80 9.9 0.50 6.2 16. 20-25 0.72 16.40 1.0 0.80 9.4 0.50 5.9 15. 15-20 0.67 16.40 1.0 0.80 8.7 0.50 5.4 14. 0-15 0.62 16.40 1.0 0.80 8.1 0.50 5ft 13. so F X sum F sum F > X avg (K-F) Gt = (.035)-steel, (.03)-concrete MRF & (.02) other 2nd LEVEL WALL uppermost level (11) EXP AREA 1 EXP AREA 2 Bldg Period(T)e 0.10 see T = Gt*(hn)A(3/4) Ft (top) = 0.000 kips MIN(IF(T>0.7,0.07*T*V,O),O.25"\/) IBASE SHEAR I Vmln. 0.040 x W Vmax= 0.164 xW V (zone 3) = 0.945 x W 0.11 x Ca x I x W 2.5 x Ca x I x W 1 R CvxlxW I(Rxn Eh = V ; Ev = 0 ; E = Eh*rho + Ev Imo I Area of Gr flr = 440 SF Wall Shear (N-S)e 0.50 kips Wall L (N-S) = 4.00 LF Wall Shear (E-W)= 0.44 kips Wall L (E-W) = 2.00 LF Story shear e 2.3 kips r_max (N.S)= 0.539 1.0< rho = 0.23 <1.5 r_max (E-W)= 0.950 1.0 < rho = 1.00 <1.5 rtJo= 1 E. (Vmin < V < Vmax)*mo c 2.3 kips AT WALL 3.1 kips ATGROUND MARK N-S Xcf-s (ft) (kips) (kips) Roof 9.37 1.67 2.33 Floor 9.37 0.00 0.00 KITSAP CONSULTING ENGINEER ROOF 1st -> Width diaph (ft) = 20 EXP~ 0.001.___CQ]] EXP~ 0.001 0.01 0.001 1st LEVEL WALL EXP AEA 10.00 0.0 EXP AREA 2 0.00 0.0 . EXP AREA 3 0.00 0.0 0.00 I 0.0 I 0.00 I F Y sum F sum F \ Y avg (K-F) ROOF 1st EXP AREA 1 EXP AREA 2 1st LEVEL WALL EXP AR1 0.00 0.0 EXP AREA 2 0.00 0.0 EXP AREA 3 0.00 0.0 0.00 I 0.0 I 0.00 I N-S E-W N-S Xcf-w E-W Ycf-w (ft) (kips) (ft) Roof 10.57 2.79 Roof 11.00 Floor 10.40 3.98 Floor 11.00 360-479-4423 Input; 1/4 07BJ022003 Shl!ar Wall 1997.xls SHEAR WALL CALCULATION CENTER OF MASS Matthew G 2/14/03 4/( SHEAR WALL TYPE: G = GWB - UNBLOCKED (5d Cooler or Walboard @ 7" O.C.) GB = GWB WITH BLOCKING (5d Cooler or Wallboard @ 4" O.C.) P = PLYWOOD OR OSB - BLOCKED WALL TYPE: I. INTERIOR WALL 0.009 ksf II = INT. INSULT; PAR- 0.012 ksf E. EXT. WAll 0.012 ksf OE = OPENING EXT. 0.012 ksf SI/I/ = SHEAR WAll 0.000 ksf # LAYER: NUMBER OF LAYER OF PLYWOOD OR GWS ON THE WAll X = Measured Distance (PARAllEL to E-W DIRECTION) from REF. POINT to C.G. of member Y = Measured Distance (pARAllEL to N-S DIRECTION) from REF. POINT to C.G. of member 2nd LEVEL ROOF WIDTHIDEPTH X Y JNIT VII W WX WY ID (ft) (ft) (ft\ (ft\ /ksfl (kiDS\ /k-ft\ (k-ft) I 1 ROOF.1 22.00 26.00 11.00 13.00 0.017 9.7 107.0 126.4 2 0.0 0.0 0.0 3 0.0 0.0 0.0 4 I 0.0 0.0 0.0 -- 5 I 0.0 0.0 0.0 9.7 2nd LEVEL WALL I I I WAll ~ENGntlEIGH" X Y NIT V W WX WY SI/I/ #OF I TYPE I (ft) I (11) (ft) (11) (ksfl /kIDS\ (k-ft\ (k-ll\ TYPE LAYER 2nd LV Wallin N-S direction 1 1 E 22.00 9.00 0.00 11.00 0.0120 2.4 0.0 26.1 2 2 E 22.00 9.00 20.00 11.00 0.0120 2.4 47.5 26.1 3 0.0000 0.0 0.0 0.0 4 1 SIN 4.00 9.00 0.00 2.00 0.0000 0.0 0.0 0.0 P 1 5 1 SIN 4.00 9.00 0.00 20.00 0.0000 0.0 0.0 0.0 P 1 6 2 SIN 4.00 9.00 20.00 2.00 0.0000 0.0 0.0 0.0 P 1 7 2 SW 4.00 9.00 20.00 20.00 0.0000 0.0 0.0 0.0 P 1 8 0.0000 0.0 0.0 0.0 9 I 0.0000 0.0 0.0 0.0 10 0.0000 0.0 0.0 0.0 11 0.0000 0.0 0.0 0.0 12 0.0000 0.0 0.0 0.0 13 0.0000 0.0 0.0 0.0 14 0.0000 0.0 0.0 0.0 15 0.0000 0.0 0.0 0.0 16 0.0000 0.0 0.0 0.0 17 0.0000 0.0 0.0 0.0 16 0.0000 0.0 0.0 0.0 19 0.0000 0.0 0.0 0.0 20 I 0.0000 0.0 0.0 0.0 21 0.0000 0.0 0.0 0.0 22 0.0000 0.0 0.0 0.0 23 0.0000 0.0 0.0 0.0 24 0.0000 0.0 0.0 0.0 25 0.0000 0.0 0.0 0.0 W-2nd.( I I I I WAll kENGT HEIGH" Y X JNIT V W WX WY SI/I/ #OF I I TYPE I (ft) (ft) (ft\ (ft) (ksfl (kiDS\ (k-ft\ lk-ft) TYPE LAYER 2 nd Wallin E-W direction 1 A E 20.00 9.00 0.00 10.00 0.0120 2.2 21.6 0.0 2 B E 20.00 9.00 22.00 0.00 0.0120 2.2 0.0 47.5 3 0.0000 0.0 0.0 0.0 4 A SIN 2.00 7.00 0.00 1.00 0.0000 0.0 0.0 0.0 P 1 5 A SIN 2.00 7.00 0.00 19.00 0.0000 0.0 0.0 0.0 P 1 6 B SIN 2.00 7.00 2.00 1.00 0.0000 0.0 0.0 0.0 P 1 7 B SIN 2.00 7.00 2.00 19.00 0.0000 0.0 0.0 0.0 P 1 8 0.0000 0.0 0.0 0.0 9 0.0000 0.0 0.0 0.0 10 0.0000 0.0 0.0 0.0 11 0.0000 0.0 0.0 0.0 12 0.0000 0.0 0.0 0.0 13 0.0000 0.0 0.0 0.0 -- ..!!. -. 0.0000 0.0 0.0 0.0 15 0.0000 0.0 0.0 0.0 16 0.0000 0.0 0.0 0.0 17 0.0000 0.0 0.0 0.0 16 0.0000 0.0 0.0 0.0 19 0.0000 0.0 0.0 0.0 20 0.0000 0.0 0.0 0.0 21 0.0000 0.0 0.0 0.0 -J. -- 22 O.O_~ __ Do!! ~ ~Q. r--- - -~ -- I 0.0000 _J!:!!. 0.0 0.0 24 I 0.0000 I 0.0 0.0 0.0 25 I 0.00001 0.0 0.0 0.0 9.1 W - 2nd. (E-W) .. KITSAP CONSULTING ENGINEER 360-479-4423 Note: Capacity of SW1 240 PLF Capacity of SW2 360 PLF Capacity of SW3 450 PLF Capacity of SW4 600 PLF CanacltV of SW6 no PLF 1.33 1.71 (REO I ALLOW) END SEISMIC WIND RXN % % (KIPS) . 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 52.39 75.71 1.59 OK SI/I/ 1 52.39 75.71 1.59 OK SI/I/ 1 52.39 63.99 1.76 OK SI/I/ 1 52.39 83.99 1.76 OK SI/I/ 1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 N-S)= 4.76 [kips] (REO I ALLOW) END SEISMIC WIND RXN % % (KIPS) 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 59.53 75.29 2.63 OK Sl/l/2 59.53 75.29 2.63 OK Sl/l/2 63.34 79.71 2.79 OK Sl/l/2 63.34 79.71 2.79 OK SW2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 4.32 (kips] Input; 2/4 07BJ022003 Shear Wall 1997.xls SHEAR WALL CALCULATION Matthew G 2/14/03 , r;/S I SECTION 1632 LATERAl FORCE ON ELEMENTS OF STRUCTURE - wall, penthouse, connection for prefabricated structural elements. LATERAl FORCE ON NON STRUCTURAl COMPONENTS- ornamentation & appendages, chimneys, billboard & lighl1flag pole, storage rack >6', cabinets/book stacks>6', concretelm LATERAl FORCE ON EQUIPMENT SUPPORTED BY STRUCTURES - Iankll/essels wi content, electrical & mechanical & plumbing equipment & associates condutt & ductwork & pip' SECTION 1632.2 DESIGN FOR TOTAL LATERAl FORCE 32-1) Fp=4.0*Ca*lp*Wp 32-2) Fp" (ap / Rp) * Ca * Ip * ( 1 + 3 hxlhr ) * Wp Rho" 1.0 reliability I redundancy factor Rho" 1.0 reliability I redundancy factor ap / Rp" 0.33 Ca" 0.36 Ip" 1 .00 1.5 for essential and hazardous faciltties hx" 9.00 (ft) - elevation of attachment above the ground hr" 9.00 (ft) - elevation of roof above the ground Wp = 12.00 (pst) All wall wi flex or rigid diap (Z 1 &2A,2B); IC & M] wt (Z 3&4) wi rigid dlap Concrete (C) & mason (M) wall (Z3&4) wi FLEXIBLE dlap Rp= 1 .50 shallow expansion anchor boll, 1.50 shallow chemical anchor, 1 .50 shallow cast in place anchor, SHALLOW = embed LIDia < 8 Rp= 1.00 anchorage constructed by use of adhesllle 1.00 anchorage constructed of non ductile material cone & msn wt 1.00 1.50 2.00 2.50 3.00 3.50 4.0 1.00 0.67 0.50 0.40 0.33 0.29 0.26 1.60 1.00 0.75 0.60 0.50 0.43 0.38 2.00 1.33 1.00 0.80 0.67 0.57 0.50 2.50 1.67 1.25 1.00 0.83 0.71 0.63 SECTION 1633.2.4.2 - EXTERIOR ELEMENTS exterior non bearing, non-shearwall panels or elements that are attached to or enclose the exterior ttem #4: body of connection = Rp= 3.0 & Ap .. 1.0 ttem #5: fastener: boll welds, dowels, insert = Rp= 1.0 & Ap" 1.0 ttem #6: fasteners embedded in concrete shall be attached to, or hooked around, reinforcln!j steel or ofhelWlse terminated to effectively transfer forces to the reinforcln!j steel. Z3 & Z4 - Exterior wall at ground floor or above ground floor & parapet braced above their center of gravity 32-1) Fp= 1.44 . Wpm 17.28 (pst) 32-2) Fp = 0.48. Wp = 6.70 (PSt) MIN" 5 PSF see 1611.5 Interior wall load Top attachment: Fp . Hw 12" 25.66 (Iblfl) (Z 1,2A, 2B, 3) - [C & M] wt & RIGID OR FLEXIBLE DIAPHRAGM ==> Min 280 pit (Z 4) - [C & M] wt & RIGID DIAPHRAGM ==> Mln 280 pit (Z 4) - IC & M1 wt & FLEXIBLE DIAPHRAGM m=> Min 420 pit - 1605.2.3; if spacing of anchor at [C & M] wt >4' check wall bending 1611.4; anchor capacity shall be > load combination (1612.2, 1612.3) or Emin 280 pit (Z3,2A,2B,1) 1633.2.8.1; Zone 3 & 4 = ap=1.5, Rp=3.0, Emln(Z4)=420 pit SECTION 1633.2.6 - TIES AND CONTINUITY TIES BETWEEN BUILDING = 05 Ca I Wd of smaller building ===> 0.18 x Wd of smaller building POSITIVE CONNECTION AT EA. BM, GIRDER, TRUSS" 05 Ca I (Wd+WI) ===> 0.18 x (Wd+WI) MARK wind dlaDh dlaDh load N&S E&W N&S E&W 18.80 DRAG STRUT: use Load Comb 12-17 & 12-18 (req Em). Increase all stress for ASD by 1.7 (steel) & by 1.7x1.33 (wood) Em (=E . Omega-o) need not exceed the maximum force that can be transferred to the collector by [1] diaphragm + (2) other elements of the [LFRS) lateral force resisllng SV$tem WOOD EXCEPTION <Omega-o = 1> - (1) light frame (wood frm wi wd s.W or light gauge frm wi wd s.w.); [2] entire bldg supported by wood swas stated on (1) If <Omega-o . 1 - meet the WOOD exception above > use Fpxl1.4 as design force and increase the allowable strees for ASD by 1.33 for wood SUPP DISCONTUNITY = use Load Comb 12-17 & 12-18 (req Em). Increase all stress for ASD by 1.7 (steel) & by 1.7x1.33 (wood) EXCEPTION: (1) Em not exeeed the maximum force that can be transfeered 10 the element by [LFRS); (2) cone. slab supporting light frame (wood frm wi wd s.W or light gauge frm wi wd s.w.) -> do not use Load Comb 12-17 &12-18 (No Omega-oJ but use load Comb 12-5 & 12-6 (same as 12-17 & 12-18 wlo omega-oJ KITSAP CONSULTING ENGINEER 360-479-4423 Input; 4/4 ~lf} I~ WU~ ():V 03-0 608>' BREMERTON CITY TREASURER , PAID CITY OF BREMERTON. WASHINGTON FEB 2 5 2003 DEPARTMENT OF PUBLIC WORKS PER M I T THANK YOU Tue Feb 25. 2003 Permit # 4426 Permit Fee: $140.00 It c-~~1F 7-;;2.-4-0 APPLICANT: BJ BUILDERS * Certificate Of Insurance Is On File Owner: BJ BUILDERS Address: PO BOX 2274 98310 Ph: 731-0932 Work Addresses: 1911 NO CAMBRIAN AVE TYPE B PERMIT DRIVEWAY APPROACH A PERMIT IS HEREBY ISSUED for the performance of the following: DRIVEWAY BOND ON FILE. This work ,requires blockage of a street or alley and may cut off access to property for emergency vehicles This permit is valid for 90 calendar days commencing with the date of this permit unless specifically called out under limitations below. This permit must be posted on the job site in a location accessible to City Employees. The Engineering Department must have 24 hours notice of the need for a required inspection. An inspection must be made prior to any work commencing and after completion of the job. Phone 478-5270. Limitations: SEE ATTACHED COMMENTS AND CONDITIONS. USE EROSION CONTROL PER CITY STANDARDS. WORK SCHEDULE Commence Work: 02/25/2003 1:00PM Complete Work: 06/25/2003 4:00PM INSPECTION RECORD- Date of Inspection: Date of Approval: Comment: CONTACT PERSON: ~/~~ (Issuer - . BABBITT) CITY OF BREMERTON ENGINEERING DEPARTMENT RlGHT OF WAY PERMIT NO. .::J.L,;l-b 1. For underground locates call: 800-424-5555 2. Traffic Control shall be per Washington State M.D.T.C.D. and City ofBremerton Standards. Notifv CENCOM (616-5800), Kitsap Transit, Paratransit, Bremerton School District (during school year), Mail and Package Delivery Services, and Waste Disposal Companies of work schedule prior to start of work, if blocking driving lanes. When blocking sidewalks, Sidewalk Closed signs shall be used at each end of the work area during construction and at the nearest intersections. Guide signs shall be used to inform the public of dates of changing construction activity and facility access conditions. 3. This Permit and a copv of the Approved Plans shall be kept on the work site durin2: construction. 4. The Contractor's emergency contact person and phone number shall be on file with the City and with CenCom. If efforts fail to contact the Contractor within a reasonable period of time, based on the nature of the emergency, all work performed by the City shall be at the Contractor's expense. 5. The Permittee and any of the Permittee's contractors are required to name the City of Bremerton as additional insured for the work in the right-of-way on their insurance policies. 6. The Contractor shall notify the adjacent property owners and the City ofBremerton Engineering Department three (3) workinl! davs prior to start of 'York and the start of Pavinl!. 7. Erosion Control and Dust Control shall be used. The street shall be cleaned each evening and at other times when causing a hazard.. Catch basins and ditches shall be protected from dirt and debris per City of Bremerton Standards. No dirt or debris shall be left on an open sidewalk. No dirt shall be left on grass or landscaping for such a length of time that it will result in damaged or dead plants. 8. Any landscaping, pavement, sidewalk, sign, mail box, retaining wall, or other structure in the RIW disturbed or damaged during construction shall be restored to its original or better condition per City of Bremerton Standards. 9. Any Stop Sign in the work zone shall be protected from damage and if temporarily removed shall be reinstalled immediately after the temporary traffic control has ended. Any other street signs and traffic channelization removed or damaged shall be reinstalled in the same locations at the Contractor's expense. 10. When installing underground utilities, the Contractor shall maintain a parallel distance of 5 feet away from other City owned underground utilities. Buried conduit and cable shall have a minimum of 2 feet of cover over the top of pipe. In paved areas that 2 feet minimum is measured from the bottom of pavement to the top of pipe. 11. All new street lighting plans shall be reviewed and material submittals approved by the City prior to construction. 12. If there is a question about, or damage to a City owned utility call 360-478-5920 for assistance during 7:30am to 4:00pm. After 4:00pm call 911 and request that the "Standby" Utility Worker be contacted. 13. Received from the City of Bremerton: . Trench and Surface Restoration Standards Curb & Gutter, Sidewalk, and Driveway Standards Other: Other: RECEIVED BY: A DATp2-2s--(5' ~ :~ . ill \f> ~ \Il ~1 ~ ~~~ Z "!9. cC:::::U - lliill ~ L.--I ("t') UJ ,...-, ~ g ;;. ~ U= ~. ~li~ !!!ill <<-I r ~ ,- ;z: ~@ ~ '.g ~ @!l .L.!-.. .- ~ ~~,~ 5 T, .. .";k~~~.J!'!'..J!l;~~~~~~~~~ OJ .. j L-O-fL1=.[Qj e~J- ~ - - 1 -- f') Inspection Report Scope of work: . i\) <U.A;) f( (23' _ _ Permit Number: Aoddre55~Jfil1' (~/)~n'\ ~ Phone: wner: -D~g} f. . -- 1 (}/Y1 . ,/ Contractor: 6 WVLVL ( r Phone: '--/ 03- OD0{lJ ~ 7 3) 013~ Inspection card/approved plans on site Setbacks Footings: required steel placement Walls: required steel placement Footings: required width & depth Walls: required size I Bearing soil (soils analysis if applicable) Special inspector (when applicable) FOUNDATION COMMENTS: FOOTINGS APPROVED: WALLS APPROVED: Electrical approved Plumbing & mechanical approved Crawl space access (min. 18 x 24) Floor joists and beams/proper clearance to earth Positive connections posts & beams Foundation vents Posts properly supportecj Anchor bolts: nuts & washers in place Mudsill: treated material Floor joists: size & span Beams/girders: size & span Notching & drilling: joists & beams, studs Smoke detectors: all required locations Exhaust fans: where required Exhaust fans insulated: unconditioned space Whole house fan, outside air intakes each bedroom Fans terminating directly outside Range hood Dryer exhaust vent All vent tenninations: windows & property line Fireplace combustion air Windows: meets egress requirements Windows: proper U valve Windows: safety glazed where required Ceiling heights Stairs: headroom clearance Stairs: rise & run; proper width Fire blocking wall to ceiling, furred walls every 10' Fire blOCking: stairs, soffrts, lowered ceilings Fire blocking: tubs/showers Fire blocking: lids in void spaces, shafts Fire blocking: stuff holes top & bottom plates Sheet rock backing Wall bracing Rafters size/notching Trusses: specs, bracing Attic access Attic ventilation WCjIl & roof Sheathing Shear nailing , Building dried in COMMENTS: APPROVED: ENERGY CODE COMPLIANCE Insulation: proper R valve Insulation: proper fastening Insulation: vapor barrier Bottom plates caulked to floors Penetrations caulked as required Electrical boxes gasketed or caulked 6 mil black poly in crawl space COMMENTS: UNDER FLOOR/FOUNDA TION INSU[.dI;l) ON APPROVED: 7 ;,I .--? 4-7 WALL INSULATION APPROVE- :.' . - -U~CEILlNG INSULATION APPROVED: t/ Cft'~ Ct/-/z-Irf{/ bA&-poxr~ Appliance location and access, proper support Appliance clearance to combustibles Venting: clearance to combustibles Venting: size & support , Vent telTTIination Combustion air . Ducts: size & support Gas pipe under test Gas pipe size & support Gas pipe: underground min. 12" below grade Gas pipe: within 6" or underground-coated Gas shutoff within 3' of appliance Gas logs: safety shut-off Gas logs: damper permanently open Wood stoves EPA certified Wood stoves & fireplaces: Tight-fitting doors Wood stoves & fireplaces: proper health Manufacturer's specs on site Chimney liner: when required Chimney: separate flues when required IWIL.\JIIMI'ilvI-\L COMMENTS: bK. To ~. !/I/erepc GAS PIPINO APPROVED: ~ ,~/ ~ FURNACE APPROVED OTHER APPLIANCES APPROVED: DWV & water piping under test DWV: proper grade OWl/: proper sizing OWV: proper drainage frttings where required DWI/ & water piping proper support DWV: required c1eanouts Vent telTTIination All fIXtures vented properly Water supply: proper sizing Shut-off valves on all fixtures Water heater. gate valve on cold water supply Vacuum breakers: where required Water heater relief valve drain to outside Water heater: seismic strap R-10 pad under water heater when required Water-piping insulated as required Grease traps/interceptors: where required Proper indirect wastes: where required PLUMBING COMMENTS: (GvV ; --- It=:s f t;;;r/~( J ee fAM-~'ff-llul4rE:e PLUMBING GROUNDWORK APPROVED: PLUMBING ROUGH-IN APPROVED: Proper fastening nails - 7" O.C. horiz. Plane Nails 8" o.c. vertical plane Proper fastening screws 12" O.C. horiz. Plane (1/2") Screws -12" D.C. horiz. plane (1/2') 24" D.C. framing Proper fastening: screws -16" o.c. vert. Plane (1/2") Screws - 12" o.c. vert. plane (1/2") 24" o.c. framing Proper fastening screws - 12" o.c. horiz. plan (5/8") Screws - 12" o.C. horiz. plane (5/8") 24" O.c. framing Proper fastening screws - 16" o.c: vent. Plane (5/8") Screws - 12" o.c. vert. Plane (5/8") 24" o.c. framing Area & occupancy separation walls Oraftstops where required Usable space under stairs (5/8" required) Waterboard where required (not on ceiling) Corridors SHEETROCK COMMENTS: SHEETROCK APPROVED: Energy code requirements met, exhaust fans Plumbing & mechanical Garage/dwelling door self closing solid core Smoke detectors where required Handrails & guardrails, as required Fire ratings maintained Exit signs when required Emergency lighting when required Occupant load posted when applicable Building weatherlight Wood siding to earth separation (6") Building address posted Randon monitor when required COMMENTS: r-1.....l.A 1 A r\i'\rJr-\.\. Ir-r'\..