HomeMy WebLinkAboutBURWELL ST., 1608
PERMITNUM~
DATE ISSUED: l"fl!~I_lllii,l,ill!OOI
CITY OF BREMERTON
DEPARTMENT OF COMMUNITY DEVELOPMENT
286 Fourth St. Bremerton, WA 98337
(360) 478-5275 Fax: (360) 478-5278
ASSESSOR NUMBER:
APPLICANT NAME:
OWNER NAME:
CONTRACTOR:
LENDER NAME:
3785-009-003-0003
LINCOLN TRUST CO TRUSTEE
LINCOLN TRUST CO TRUSTEE
REED CO CONCRETE
SUBMITTED:
03/01/2004
VALUATION:
$600.00
$26.55 2211
$17.26 4580
$4.50 0236
Building Permit
Plan Review Fee
State Surcharge
TOTAL FEES:
Inspection Requests
DCD: Building Inspections
L&I: Department of Labor and Industries
ZONING: CBR SITE ADDRESS: 1608 BURWELL ST
PHONE: ADDRESS: 6312 N FIDDLERS GREEN CIR 400E
PHONE: ADDRESS: 6312 N FIDDLERS GREEN CIR 400E
PHONE: (360)479-5441 ADDRESS: 6116 KITSAP WAY #4
PHONE: 0- ADDRESS:
APPROVED: 03/18/2004 EXPIRATION: 09/14/2004
REMOVE & REPLACE THE CORNER OF A RETAINING WALL 2 FT X 2FT
Building Code Edition: UBC: 1997
Occupancy Group:
Type of Construction:
Flood Zone:
Setbacks: (Front) (Side) (Rear) (Other)
Sanitation Method:
Number of Bedrooms:
Square Footage:
Bid Price from Applicant
1 TOTAL
(360) 473-5870
(360) 415-4000
Fire Inspections
H/D: Bremerton, Kitsap County Health District
PW: Department of Public Works
(360) 473-5380
(360) 337-5285
(360) 473-5270
This permit shall become null and void if the building or work described and authorized by this permit has not commenced within 180 days from the date of issuance, or if this building or
work is suspended or abandoned at any time after the work is commenced for a period of 180 days. Obtaining inspections at intervals not exceeding 180 days identifies that work has not
been suspended. I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of laws and ordinances governing this type of work
will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel provisions of any State or localloaw regulating
construction or the performance of the construction. If listing the owner as general contractor, I certify that I am exempt from the requirements of the State Contractor's Registration Law
under Section 3, Chapter 126, Laws of 1967. All revisions to an approved plan require DCD review and approval prior to performing work. All building and tenant occupancy permits are
required to pass final inspection prior to permit expiration and obtain a certificate of occupancy prior to use or occupancy.
SIGNATURE OF OWNER OR
AGENT:
PRINTED NAME:
all conditions of zoning, building codes, and State and Federal laws.
DATE: ~ ~ 123 . tJf.{
CONDITIONS
City of Bremerton's approval of this application pertains only to the City's regulatory jurisdiction, and thus compliance with City
regulations does not necessarily ensure compliance with federal or state laws.
.s~
~
1. Locate all buried utilities prior to digging. The property owner shall bear all costs for damage, repairs or necessary
relocation of underground utilities due to his activities.
2. Building Plan Review:
Code Compliance-All work in the City of Bremerton shall adhere to the following codes:
1997 Uniform Building Code
1997 Uniform Fire Code
2000 Uniform Plumbing Code
1997 Uniform Mechanical Code
2001 WA State Energy Code
2000 WA State Ventilation Code
1998 WA State Barrier Free Code
As of July 1, 2004 the codes will be as follows:
2003 International Codes:
International Building Code
International Residential Code
\
Page 1 of 2
,
CITY OF BREMERTON
DEPARTMENT OF COMMUNITY DEVELOPMENT
PERMIT NUMBER
DATE ISSUED:
286 Fourth St. Bremerton, WA 98337
(360) 478-5275 Fax: (360) 478-5278
ASSESSOR NUMBER:
APPLICANT NAME:
OWNER NAME:
CONTRACTOR:
LENDER NAME:
3785-009-003-0003
LINCOLN TRUST CO TRUSTEE
LINCOLN TRUST CO TRUSTEE
REED CO CONCRETE
ZONING: CBR
PHONE:
PHONE:
PHONE: (360)479-5441
PHONE: 0-
SITE ADDRESS:
ADDRESS:
ADDRESS:
ADDRESS:
ADDRESS:
1608 BURWELL ST
6312 N FIDDLERS GREEN CIR 400E
6312 N FIDDLERS GREEN CIR 400E
6116 KITSAP WAY #4
SUBMITTED:
03/01/2004
APPROVED: 03/18/2004
EXPIRATION:
09/14/2004
International Existing Building Code
International Fire Code
International Mechanical Code
International Plumbing Code
International Fuel Gas Code
1998 WA State Barrier Free Code
2001 WA State Energy Code
2000 WA State Ventilation Code
CHECK FOR NOTES ON APPROVED PLANS.
3. Driveways and parking areas must be paved.
MINIMUM INSPECTIONS REQUIRED
Inspection requests must be received by 8:00am in order to be scheduled for same day. To request an inspection, please call (360) 478-5275 and be
sure to provide your permit number, name on permit, site address, contact phone number, and inspection type.
Foundation Footings
Final Inspection - Building
Driveway approach
Page 2 of 2
~ ~1~ ~lB 2~4~ ~
BBfJ i{ DDC; D.3
c.~ R..
~uTi
BREMERTON
eUflOlNG'DEPARTM"ERMIT CENTER
Department of Community Development ::- 286 4th Street :, Bremerton ::. WA:' 98337
(360) 478-5275 :;- Fax (360) 478-5278
Building Permit Application
APPLICANT: 0 OWNER
I Site Address /6'08 f3 v-rLP-<. \ \
License # & Expir. Date:
Contact Name: JDhf1 I<ee Cit , State, Zip
Contact Phone #: (J60 ) ." 1 f'1I~ Phone #:
e '60~? t :1;
Check the type of application for below:
D NEW SINGLE-FAMILY RESIDENCE 0 NEW COMMERCIAL
D NEW DUPLEX 0 COMMERCIAL REMODEL
D NEW MANUFACTURED HOME 0 COMMERCIAL ADDITION
D RESIDENTIAL REMODEL 0 COMMERCIAL REPAIR
D RESIDENTIAL ADDITION 0 NEW MULTI-FAMILY
D RESIDENTIAL REPAIR 0 TENANT IMPROVEMENT
Authorized Agent Address:
(
)
NEW GARAGE/CAR PORT
NEW ACCESSORY BLDG
NEW SIGN
STRUCTURE DEMOLITION
GRADING (Cubic yards: _)
OTHER
Valuation Plan Review Fee Permit Fee Surcharge Total Fees
hOG_e>-O /'"" '-I? i -5 /
l (;7. '& (p ':t,.5~ l.f I!'.:>"-O
, .
Application for which no permit is issued within 180 days following the date of application shall expire by limitation, and
plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the bUilding official.
The building official may extend the time for action by the applicant for a period not exceeding 180 days on request by
the applicant showing the circumstances beyond the control of the applicant have prevented action frorn being taken. No
applicant shall be extended more than once. In order to renew action on an application after expiration, the applicant
shall resubmit plans and pay a new plan review fee. IJ
APPLICANTS SIGNATURE:.# ~....X DATE: ~ - I -()4
b ~~[gB\Vl~lD\
" r.1Ar~ 1 20fi4E1!?)\1IT CENTER
BHEMERTOl'J
SUlLDING DEPARTMENT
: :... ............ ";,
! ~n~ff~it1M~;:auE~~~~t~~z:E~:~~mlill~lfl~~~M~!tR'I,:
Department of Community Development :~ 286 4th Street ::. Bremerton ::- WA ::. 98337
(360) 478-5275 ,:- Fax (360) 478-5278
RESIDENTIAL SITE PLAN REVIE\V QUESTIONNAIRE
Pennit applications are reviewed by our staff to make a preliminary detennination of the presence or
absence of unique areas on the property. To help us make tins detennination, please supply the following
information with a scaled and dimensioned site Ian.
Applicant: ::JOhn 17 eeJ..
Description of Proposal:
Street Address (or street name if no address has been assigned):
Tax Account Number: ::3>
r We...\ \.
Critical Area Questionnaire:
l. Is there any standing or running water on the surface of the, site at ANY time JE( YES 0 NO
~ during the year? If YES, please describe conditions:(.J/1 e Vl ; +- M \ V1 :;>. ~.. ..... e..
I ';) ('0 V\V) ; r\~ W-~-\c.;J-" ;)/1 ~ ~ 11tr
2. iue there wet areas on the site? If YES, please describe: DYES. lSlNO
.., Is the site characterized as: o Forest 0 Cleared [&t. Developed
.J.
4. Please give the overall slope of the parcel_% and the slope at the building site _ %.
5. Is the property within 200 feet of a shoreline? DYES JRJ: NO
.
.
6. Will the proposed structure be aesthetically or functionally disruptive to DYES ~NO
surrounding properties, the neighborhood or the community?
See diagram explaining the slope calculation on the back.
The applicant hereby certifies that an of the above statements and the information contained in any other
transmittals made herewith are true, and the applicant acknowledges that any action taken by the City of
Bremerton based in whole orin part on this application may be reversed if it develops that any such
statement or other information contained herein is false.
Sign<<!::":@J
O-;;(l/ -o"i
Date
Site Development Figures
Percent Slope Calculation
Slope is calculated by dividing the vertical distclnce
by the horizontal distance, then multiplying the result
by 100. Example:
Vertical Distance of20 feet
Horizontal Distance of 100 feet = .2 x 100:::: 20% slope
60% ~, '"
~ '"
~ r ',~" ~~
~ ~,~ ~
~ ~"'-.
\"; /\~ --........ ................
/':)" ~ """"- "
..., aD/' V", ,"",
.) 10:[.' --'-'1-. ' " "'"
0;:> ...._~.....~ '-....
I ",
I-~ ~~~
15% V/""\ -........_____. ~ ............... .~
~ - ~~"
-------- ~~
J[2' /;'0..", --------- ~~
." -"''t. -------- ,~
o ;:> ~~
I ~
Residential Site Plan Review Questionnaire
Page 2
CITY OF BREMERTON
DEPARTMENT OF COMMUNITY DEVELOPMENT
Receipt Number:
!....'. ,".'(".i1lIlil'!...,..<;i:.i." "'i
" ';:~i';';';~," ~;'i,;,;;,,'
m" '(,"':C'l, i'i'im",~
286 Fourth St. Bremerton, WA 98337
(360) 473-5275 Fax: (360) 473-5278
Total;
$ 17.26
$ 17.26
CASH
Page 1 of 1
CITY OF BREMERTON
DEPARTMENT OF COMMUNITY DEVELOPMENT
Receipt Number:
"_:""!:!i;"i"'"ill!'l:
lI~~~ ,,<,,'~, ,j lb""f@
286 Fourth St. Bremerton, WA 98337
(360) 473-5275 Fax: (360) 473-5278
BB04 00903
BB04 00903
Building Permit
State Surcharge
1/2211
1/0236
$ 26.55
$ 4.50
Total:
$ 26.55
$ 4.50
$ 31.05
$0.00
$0.00
$17.26
BB04 00903
CASH
Total:
$ 31.05
$ 31.05
Page 1 of 1
\
\
./
C:;I"-M S
..:::::;:. "'\ r' ) f..., S
Lr' f\ /b /
f}~~ liA (~iA.t3!lt7^ j
iO
,
,
jV\u-
- ~ -- - --- ~ ~~~~L -.1_-
.1-- __ _~lClf-eJ:C... I
~_ if'.. ~ I. I - r-
-'\1 ~--iU~~lJf}~i--
ii, ' .,
. - _~---.--. '~,'--~~4?+.~---'.i-~
~ ._m_"~ ~I__.. i .__ ;____ I ._ i__.~: i
_d' :.~-.', 'T'
: ! ~ ---;---+-- :--- -:; . --i- I
. " '- - iQ,j~iJ i -':'/
~J~!-I-~ -~i.. :~~1;~~1~O~~~_~. ;~~~~__i .jnE~'/:C1
! -:i__: ;:~ -h~iNGriEPAi\TI~-- :~k'qi9P:J ,1f
11+1 i : .._, . T -, ...--::~~h-..
,i :: j , ii, i . : ' 1 j : ! ,~/i
! -'1 i I ! I I j_.,,~:=-+-~=-+-=~+-t--; i' ;- :
-.-.l----r-----.-.r---+-~"~-+----.~i---,,-----i-.--.----+----------j-.---------; .------j----- --. ': i! uL ,,_ :__ __ ,._.L I
I J I I I i I bJi its! i i i : -r'T"I--T- I i u,__
~rm-_!'n4hi---t---:-ni -!-e~+ i-: - I '-j-t---j----I- T --1--Tm ,-
:'-'1-1 '---r--i-r--: . -:-i---1 .17.-... :, i i- -! '---+-'i '-:- I .- r
r--y-r---, - - --;-- - i- !' ' --r : '---;- __L_Lu_ i_
i----.j---iL.-; ---; u_ I---r- : ml_ i-;-- i- --I -un :---t -- -1--1'--1---1 ---+-j-- 1---:- -: --:
--~---r-j----;r ---~-~l-' "
I N!~ icbifrc 5 '~,' -- .'5e
i 2;:.;; ,
~__ " I
-T- -- i
-r'
~ \
tLf4
~rk.... LV1~
I 31O<i~'
'J--t I I I
, ;
H_
~
:-0
. :)
: - k.
<h) ... ':-<l
..~-~
.-~~.
. ,~
i-
:
i
,
!
!
I
i-
;--
----- - -. -
i
i"
:
!
H '__H_ _
j
i
.
,
!
.. !
I
i
I
..
U_HUH ... .... /) < __ ~
1'\ I ~h -f-.
__...._ '__u_
r)i,
!
. -.---
--
_ _ .....I---u- --
.
r-',\
.= .---
}\
f \
\JJ h..l~,
! 4:..1
i
,
.
--
(? n1 '5 ~
_fJ1ro b,;
----
-
if
i\!e; 9{r~ ) ~'1 vV~S~#
v- .. .....
!
i
-- ..-
!--
.-
,
House
~I f\
~
.. .
!
!
-
"--~'
f
~\k tVl~: 5fP~
L_
:
-
u _ _
i
:) J.. ..
\i . ,
,
..- -j~
---
.--
:
!
,
!
.
:
"--
i
!
T
-,
~'~i
!
_u_
~--
I
\ ~U___
c; ~#s
'(;t f'- U 6i'S
----- ,----
i
i-I-irJC (~b
!
!
iU
!
.
.
\
,
~_ .10 ,_
.~ -ulru~i '\. \ .~
""IT-
: ,
i
~-
.......-
..'rJ ,..... ....~
-
F
-
Ui-
,
,
i
.___n..f.____.M_ __
: :~i.
I
!
-......L
__.j! I
--I !' u;_ i ~--_._--!-
I I I I i
,- -- -1- 1---- i . 'I---i-i
-;--.. -:~-j-:-t--.i.----i--..i-
__m_ ------ ~,- <-----~.~.------~--._- .--+.- -- -- [" --.---..-..l- --. ---.+-
_.u_i_. ~--- +----j---: ;---j-
._._ u_ ____" 1__~_"_1.._____,__, I
: i i i !' uTu- ,
i : j I i
i i I
! ! i i
-T'--- I _.~- -----+----...--(-
Iii !
_ J____J~L_J~~L
i ' .. ! i i -
!._.~_ _'__,,_ ~! __ __ __ _ j _ J
, , i !
'-! -':----i-----:.----I
,
-_._-----,--_._--~.-
I
__._.___ i I
I -r---T
.: . J . i...1
: "C--l----\
\ \ 1 I
CON~OLlDATED ENGINEERING
/ . R. B. BOUGHAN P.E
STRUCTURAL & CIVIL ENGINEEoR '& GEO TECH
OR, WA, 10, CA, UT, NV, CO, & AK
P.O. Box 2321 -1740 NE R'dd I
Bremerton, WA _ 98310 _ (3~0)~~9Rd55' -9S8uites 302 & 303
- - (360) 698-9094
"0
I
t{l
1- t 6.
. ~@IQ; a.C. .
\-t 4
b
. I
;;;,
t 5 @ I ~ O.Co
leu
. 4~o.co
'l;J
~cC
""0
"Q
Z-t d
~ ~6 fw:) \tl \ (JAvJ p~
I'-\d r€ Oa." (V\+t; eK~) t;..~
6ju.\ \ to -\-~ ~ ~\ \s-
..
t?!
~ - 4-7'l~5J?f
2.1 'A '1/ CJ~
'1__1'(' .
-:"',ee+
b0:-rC0 ~ \ \
i
~~-
I
Sf.
i:' "~~~O' . :'~~~-~--4i;r;\c~.- "n1:..., t. ,IL
. , e.' _ L ~ <: ~ 5", I n~s .
~cr-ek
. .-~~:~
_T-.-j~<<:- ~'\~~~C"M*
- ~'1[b"~7;is_iof~"IF f ;
i~<"(;<.'
_.~--.- - ---~-_.~ --,~_. :---- ;--- '
i
(;_i i \"l
- - ,;...l
,w
--'_f-
__~L_,.__.j
i:3"
1'\
- ,r
,'"'
V\
____1_________
cl Q0J<.. ..-
-~T ' . /
I . , . I . "
-----~-.1.--------~---..-.-1-.. __.___j_________"[.____...__+_______..-L .. _n_y____ ----+.. .- _: .--. _.Q :_.
il (\~ qvs;~uri ~oJ~ {,k~1 Wlc. . 0>
._f,~IC4i(I~.~~~JBl..~:!5%0 ~l~
;, ~ Ii' I It: I 1.1 I ' . l .
-ru1ltet:.i-<1~-~-\S~Tf~J:r\\~--j.
-~~-~. -- ~~e.'" :'.-".'~. ~i.. L--!..--Lo..,,-m.L -~. -, ".' _ --'i-
If'! _! ! ! i i ~ . I I
...'.' _~_r:fle..._~t"j."u-kYl.-u-i.ef\!.~nUr.re.JY1~... ...__ ...,
I I I f J 1 i /l I I ' I !
frJrLi.. ~ee*__Jtt'il>rn... ..__.
I I 1 1 ;' VI i ~ I Vi ! ()o' "0,
__~f)r:,Y1e .l'l:u/..~I../Jf..JGJ-L^- _~IJ't:-e, 1"'. \ _<tI'\~..
k-! ' (),) L-' I ~ "l b' !
_J/ _1i1_ ~a d<aul TI i~l.:z.. i u..u I e
J;P-I! I 11_1 I I
-JC!tludj'~-' r\ifl/1 -~ c~ct:ek
~yf I. ' i I :' I
-uC: Ol'~ ~,,- --:.
! I ) 1"'"""0---1 '
In____ I I I I
i '--l---'--'--I- ~ -~-r ".- "---;'
, i ' : i i
-,~ __.L -.-----+------"-+.. -_.~--..- ~-~ 1'-
I i
_ _ _I _.__._._.,: H__'___
--~T
'"
i
----~--_....~_. ,--
::5"
- "'-
'Z-.
.""1
"i--~'-i~-:~T~-:~WJ ~-~I ... I. 0 i-'
-.L-Q:.'----~,'........ '__.i.-___. ......-. . '." ~i.. .__i...! ~o _Ln.'~t
i i i I:: i~!! I i
,---i--.-.-. j- HART 42004-1' .: .. :___m..
! ,-- i i ; ';- Ii.' .
_ ._--;-- I i BREMERTOI\f .
, i ii, i
- J.-.-:f3UfbOlNGIJEPARTMENT
I I I . I I
I .
_., _.1.______ _L
--T-
I
~f-
I
I !
'-i--r
I
i I
i ! i
___-'-.. .______._J_______...._
, , ,
I I !
; I ' ' ,
____ _______.___n._.__..__.~._ _'___..-.___._ _....
i ' ' I
-"-~--~--~-' --- - --'.
i
i
----~
__ __.L.__ _L____ .____.....__ ___.. ~_.__.___..___
f i;
___ !_,____~.._.J_~____ I ' ,
! j : - -----r--~--~----.--._.-
- :----J.-.-.---..L-~-.- L.___J
i i ! ' I
~-..-~--L-----j- _._-._--..!_-~--..- --.."--"--"-
I j! I
I l' __!___~_,,_L________L_ __J
i
i
._.'.......n_L __.L. -C..
i
) ; I
..------(--...---r .-~-r---.- j
...-- ---r---"'~","~-! i
I'
9>
C)
<0. ','i~ :.' C"\'
"-' , '...>iI'
,0 .~p ;...Q
0' i_'
i i:>
-:Jr-- - in-,
..pi r
I :r ! V'I
l
<:::;Y.
C
V'
~
,
--;..,--
~
~
1 IT
~G. ihCkc' ..~
~ "',
~:--'
\AI
- '! _.._ uoo___
L SITE ADDRESS
If) 0 B ~~r~eLl
:c /TY 0'
BREMERTON
o
DURING INSPECTIONS THE BUILDING PERMIT & APPROVED PLANS SHALLBE ON SITE
Permit # BB04 - OO~Q3- ~@~1I @[(!] ~~1I~
For Inspections Call (360) 473- 5870 Approved Date Notes
Erosioll COlltrol III Place
1st FOUlldation Footing
FOUNDATION Foundation walls
DO NOT POUR CONCRETE Plumbing Ground Work
PRIOR TO APPROV AL III Slab Mechanical
Footing Insulation
2nd PLUMBING Rough In
MECHANICAL Duct / Vent
GAS PIPE Support / Test / Meter set
3rd Hold down C011.11ectiollS
Shear Pallel nailillg
FRAMING L&I Electrical Approved
If pt & 2nd are approved Ventilatioll requiremellts
FramiJzf!
4th Under-floor
walls
INSULATION .. ceilillg
sth
6th
FINAL
SHEETROCK
All of the
above
Must be
approved
Prior to
final
473-5870
473-5927
Driveway 473-5270
Sewer 473-5270
473-5384/5385
ALL FINAL INSPECTIONS COMPLETED
DO NOT OCCUPY BUILDING WITHOUT BUll.,DING DEPARTMENT APPROVAL
OCCUPANCY VIOLATION IS A MISDEMEANOR - SECTION 305( d)
PROTECT THIS CARD FROM THE WEATHER
. ...
CITY OF BREMERTON
QEPARTMENT OF COMMUNITY DEVELOPMENT
PERMIT NUMBER 1_!i!I!.~!!!1
DATE ISSUED:II_II;_I!lil:I!I:III~l
286 Fourth St. Bremerton, WA 98337
(360) 478-5275 Fax: (360) 478-5278
ASSESSOR NUMBER:
APPLICANT NAME:
OWNER NAME:
CONTRACTOR:
LENDER NAME:
3785-009-003-0003
LINCOLN TRUST CO TRUSTEE
LINCOLN TRUST CO TRUSTEE
FIRE ONE
SUBMITTED:
02/04/2004
VALUATION:
$4,200.00
$4.50 0236
State Surcharge
TOTAL FEES:
Inspection Requests
DCD: Building Inspections
L&I: Department of Labor and Industries
ZONING: CBR SITE ADDRESS: 1608 BURWELL ST
PHONE: ADDRESS: 6312 N FIDDLERS GREEN CIR 400E
PHONE: ADDRESS: 6312 N FIDDLERS GREEN CIR 400E
PHONE: (206)575-0311 ADDRESS: 21412 84TH AVE S
PHONE: 0- DRESS:
.,
APPROVED: 02/12/2004 E PIRATION: 08/15/2004
FIRE ALARM INSTALLATION IN 5 UNIT APT,
Building Code Edition: UBC: 1997
Occupancy Group:
Type of Construction:
Flood Zone:
Setbacks: (Front) (Side) (Rear) (Other)
Sanitation Method:
Number of Bedrooms:
Square Footage:
Bid Price from Applicant
1 TOTAL
(360) 473-5870
(360) 415-4000
Fire Inspections
HID: Bremerton, Kitsap County Health District
PW: Department of Public Works
(360) 473-5380
(360) 337-5285
(360) 473-5270
This permit shall become null and void if the building or work described and authorized by this permit has not commenced within 180 days from the date of issuance, or if this building or
work is suspended or abandoned at any time after the work is commenced for a period of 180 days. Obtaining inspections at intervals not exceeding 180 days identifies that work has not
been suspended. I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of laws and ordinances governing this type of work
wiil be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel provisions of any State or localloaw regulating
construction or the performance of the construction. If listing the owner as general contractor, I certify that I am exempt from the requirements of the State Contracto~s Registration Law
under Section 3, Chapter 126, Laws of 1967. All revisions to an approved plan require DCD review and approval prior to performing work. All building and tenant occupancy permits are
required to pass final inspection prior to permit expiration and obtain a certificate of occupancy prior to use or occupancy.
I have read, and agree to
SIGNATURE OF OWNER OR
AGENT:
PRINTED NAME:
CONDITIONS
City of Bremerton's approval of this application pertains only to the City's regulatory jurisdiction, and thus compliance with City
regulations does not necessarily ensure compliance with federal or state laws.
~
1, Prior to performing any renovation or demolition work, puget Sound Clean Air Agency (Clean Air Agency) and
Washington Department of Labor and Industries (L&I) regulations require an asbestos survey be performed to
determine whether there are asbestos-containing materials in the work area or structure. The asbestos survey must
be conducted by and EPA-certified (AHERA) building inspector (except renovation or owner-occupied single family
residences).
2, For more information, please contact Clean Air Agency through their web site at www.cleanair,org or by phone at
800-552-3565 or 206-689-4058, The L&I web site can be found at www.lnLwa.gov/p-ts/asbestos/asbestos.htm.
3, Fire protection systems must comply with UFC, NFPA, UBC and BMC standards.
4. Premise identification required to UFC and BMC standards, 6" minimum and in contrasting color to building.
5. Knox BoxfKey Lock Box required to UFC and BMC standards,
6. Provide fire extinguishers per Article 10-1 of the Uniform Fire Code.
7, Dumpsters shall be at least 5 feet from combustible walls.
8. Acceptance test required prior to activation of alarm,
..cy:; (jIkj;.pN4~
Page 1 of 2
7-/fj-oLf
..
CITY OF BREMERTON
DEPARTMENT OF COMMUNITY DEVELOPMENT
PERMIT NUMBER
DATE ISSUED:
_"~~!iJ~""';';';';';~~.;1;'W ,""~,;,;;rn,;';'~ ""';;'i\'i' ..'
" ,:i<'ir":;:\v. \~;i~,' ''':'''::'i/'' "~~: < ~li~"
Di......;....; '!;,~_~.
~i ","',',',',' ,,' , ,,,',,..<,, """ "" ..,"" ~
286 Fourth St. Bremerton, WA 98337
(360) 478-5275 Fax: (360) 478-5278
ASSESSOR NUMBER: 3785-009-003-0003 ZONING: CBR
APPLICANT NAME: LINCOLN TRUST CO TRUSTEE PHONE:
OWNER NAME: LINCOLN TRUST CO TRUSTEE PHONE:
CONTRACTOR: FIRE ONE PHONE: (206)575-0311
LENDER NAME: PHONE: 0-
SUBMITTED: 02/04/2004 APPROVED: 02/12/2004
SITE ADDRESS:
ADDRESS:
ADDRESS:
ADDRESS:
ADDRESS:
1608 BURWELL ST
6312 N FIDDLERS GREEN CIR 400E
6312 N FIDDLERS GREEN CIR 400E
21412 84TH AVE S
EXPIRATION:
08/15/2004
()
~LD
(
9.
10.
Fire alarm system required and must meet NFPA 72 requirements,
Alarm system shall be pretested prior to scheduling an inspection. Pretest record shall be made available to Fire
Marshal at time of inspection,
MINIMUM INSPECTIONS REQUIRED
Inspection requests must be received by 8:00am in order to be scheduled for same day. To request an Inspection, please call (360) 478-5275 and be
sure to provide your permit number, name on permit, site address, contact phone number, and inspection type.
Final Inspection - Fire
Page 2 of 2
~4- c~~(f4- '""'iJ E"\ RE
co*-,. . t .0-' "... 04
..i,WiO.qUU...... ..'...I.iiD.....I. ..~TC1!i!.....,D.;.I.....:tijj1:.Jlr-g~...:...~:JI.:rI1l.....n~li:i::;iii!;):!f:)i;:):;;J:
~,;;~~~~~
APPLICANT: D OWNER ~ CONTRACfOR D OTHER:
SITE ADDRESS.: \ <.008 ~u..~""E-LL
OWNER:"T E..a.a..tWelS .s \ M.e. ~ S.
CONTRACTOR: ~l~e:. OrJ":' .I.....G.
CONTRACTOR LICENSE # F\~~I ~ 099\<.\.1
CONTACT PERSON: 1)~L..e. V K\...E:.\..)
ASSESSOR PARCEL #:~ ~S ODQ () 03 OD'D-:S
q 8'3'-{O
ADDRESS: ,Gila.( MH~~Ct..C HIL~ 0&1- YO'l...'r ORelr-l~O 1 \"l~
ADDRESS: '\b~0lC5SSZ.8 TUKc.JILA \JA 9"81"38
EXPIRATION DATE: 5 - llo - oS'
CONTACT PHONE # (3(PO) L./ '78 - 0 c.("Z..~
D SFR D DUPLEX
D SIGN D DEMO
o NEW D REPAIR
D SEWER
129 MULTI-FAMILY D BUSINESS ~ OTHER: FHZ.c. 'rl L..P.~M
D MOVE BLDG.
D REMODEL
D MOBILE D GRADlNG(yds):
D ADDITION D OTHE11 ~ Q;....... ~.~.' ..U ~.Y!. .~. . mI.
ILl!
D SEPTIC 11 f'~_,:} 012004 LJ
. ~'
EI -,-,.,..), ~I
- 1\1 ____
INTENDED USE:
p p.a..~ E....v"\
NATURE OF WORK PROPOSED: .:.L...> S~l..-'- 'F\/t.e....
S II hJ-
SQUARE FOOTAGE: Dwelling: \ 10D f Garage:
For De artment Use Onl
VALVA TION:::PLANREVIEWFEEU::;:::PERMITFEE .q...),'::SURCHARCES
$ ~" $ ..J)-. ~1~'.~ $
Decks:
$
" '-IZO().(JO
::ToTAL FEES;:'
.. . - .-" -. - - ,.
Applications for which no permit is issued within 180 days following the date of application shall expire by
limitation, and plans and other data submitted for review may thereafter be returned to the applicant or
destroyed by the building official. The building official may extend the time for action by the applicant for a
period not exceeding 180 days on request by the applicant showing that circumstances beyond the control of the
applicant have prevented action from being taken. No application shall be extended ~ than once. In order to
renew action on an application after expiration, the applicant shall resubmit plans and pay a new plan review fee.
I hel"eby certify that the above i1tformatio1t is correct to the best of my knowledge.
APPLICANT'S SIGNATURE: ,~ -* DATE: 1- '/.9-0'1
hpapp.dot revised 4/23/97
CITY OF BREMERTON
D~PARTMENT OF COMMUNITY DEVELOPMENT
Receipt Number:
286 Fourth St. Bremerton, WA 98337
(360) 473-5275 Fax: (360) 473-5278
Total:
$ 4.50
$4.50
CASH
Page 1 of 1
Z
::5
cJ.
.J
~
u..
uJ
.J
cD
d.:
,u
~D
~~
Q~
~uJ
sr:!. ~
v1-- l.!.-
uJ lJ.. . uJ
~uJ ~~
..:iJ (J!'!J uJ ()
uJFG F~
1_ ~,(]
I- V1 CJ' Jl
'O~21-->'l\J
2__:j~2
. I /> cL 0 I
.--J uJ ..-' Z J -'
do~3Qt0
~~.-J >is
:z .-l .J Z 0 :J:
uJ 4 d:: -- :: 0-
G~~ ~1:i
'lU~1-
:z-
aZ
::s
~
:::s
cL
LL .
.
;:
III
-:r-T C-
~aOJ ~
r-J _ c(l ~_ I
N~NcrTO-O
:i~~><O~lf)
u)Ulll1cj~~~
I-~~ Vl
::c;c ~
rJj l!:l CJ ~
----- ~
Z Z z Z --.) c::~
-y.-;<:.::::!. OU
1_1-1--)(~g:i
ZZzw<uJcL
uJuJuJ!-7t:.uJl!J
-,.-J-1'":ZuJ:ro
_->--w:s:>w
J1c1JlrJc:icJ>lJ-
" 0 u.J
~ d ~ ~l::Cl'
LL 2~CJ cL ~
.A" ," to () ,
__ w..L0 b.::;
~ (l...-J ~ U 2 -.I
LV ~ ~ ; :2 uJc{ 3
I-:JOD2cY.w~O-
4:: ~ 0 0
<::::: -' --' __ Q cY .-.1
,?:.. <1 4: ..J J... C) <:!:
'1-: 4: _ f-:- a ::S
I u.J ~ ct: -z:. d: 0 :z
L..- cC ~ uJ - L!J ~ d::
OH_OUl'S:CO :2
~__",,"""".:-cr~
.-J . '" rt]
-~
cO IIill I · ~ (f) g lEI
4:.
IL
~11'1Y1
~ c:1 n
-':J
-,~...
~<-'
- .,
~
fCl ' 0
-w. .2 a." .
': ~ ;;L (:i,' :. ",
P4 a ~ ,..,
CJ ,:r: ~. .', . .
I_ ' cO ' cr'uJ:
ZN 2:;z ...
_ I _:s.cD,. I
ct +1 1"1 Z J 0, 2 .
~? -.54 ~<l
CJ -;; 9uJ~Vl~
w-- ~ ~~cL;~
0] I ::c~~
2 zCJUo..-J
is ~ ~r-uJ:r3
~.-J o:~pio-
_ ([ ti...J UJ 0
:::s u 2<1: v1 cJad!
dJVio~~~~~
~l::(JuJ::Ss
"jzc::LXO
~:58;'"'f'
a:r-toGGJ
f-::;..J )
tfl-...J uJuJ~
z.~jzz~
rdl<lOor
<)
'G
~
C)
~
~
J~
. '..,' ...... ",
..' ).)
. '. "." ~
, ,'.,'., .."
. .,' . (J
., .'
. '..,. '.
. ..
-
I
Ofl
~Ul
1.9
~~
6--3
2
(]
-
I-=:i
~ IN'
I
-1 1_11.
~ ltil 0
LC :0 C(]
I--: i I . tr:
i--n 1 .ct: .
2 !~>':
- ILl] 1-"
Z !~~
G:i ;...... ",'
.-r' i ·
'-l..., I v1 .
~ "~uJ
.(( ';2 ~
_4:..
uJ 'luJ :'
~ i:2F'
.1(1 -:r
, cs:1
~~'~
r-- :rl
~u. ...!
; N'l
,~f"'!;
. ~..~-,,~
:::r
....:-... ",
~
.
,.~
~
If-'-..
0::
g;
0.:.
W
Q
c..!J
Z
9
5
m
,
.~
~.
~
. ..
..,' ~.
,.' i"
.' .' ~ ~ 0
, ": ".,Q (J It
. ....m '
..OJ
.()
<.J
r::t..-
.w ~
VI '2:
~ uJ ,.,
[('5' "
VI
'. II
J\
~ATT~RY CALCULATIONS
Date
By
lla02 \3URWELL
'B R ElVLE....R r l) '1\.) VI A
l-z..~-o4
D W KLE..\C\.)
,Project
Manufactuer: Sl LE...N"\ KN.\ G l-tr
Model SK.. LL'LY
SUPERVISORY CURRENT ALAR.."i CURRENT
# QTY MO.DULE/ DEV I CE CIRCUIT NAME MA Unit TOTAL MA UNIT TOTAL
1 I S\< L 2-L Y CONTRO l J?1\\--\tL SO 50 Z,SD 2.50
2 \ S K 7-\0'-1 DIG lTAl DI~lER. - - 10 10
.'
3 q GX 9 \ Y\l N\\~\ H(lR N - - \1 \5"3
4 I MTWP ZLJ1SW \-10 ICN SlK()BE - - t 51.. \52-
5 ,......., r-:
....".. ~ - -
6 . 0 I.S li:9 LS tI \ IJISJn)
~,
JU 1; ; U '- 21 '(14 l~J
7 t t,.."" ~.) .~,)
8 oHtlVltH) UI\
IBU LDING DEPARTI ~ENT
9 I '~c"""I'"' is''''':i"&:!i I
I_~~ ~,
10 I' ,,-, M:;'~~,_ ~'~~'~
1
I I ~\l.10NI BC~
11 ,
12 k ~APPRC YED-~\ '.
~I\
~ FE)} /1 ~ 2JW4 ~ l\
13 I~ ..; I
.
'\ j[{ ) I
14 )
15 1~IlL [U) ~q/9 tJ
16 ~V L/ pJ 1 -u-c iJ U '-
17
18
Total Supervisory: 50 Total Alarm: to "LS
Supervisory: Zy hrs. X .5D = \LOO:
Alarm .Q,g:3 hrs. X La 2..S 51.0, System Total l '2-5 \ . 9
=
Add Safety 12% =. \ '50 . ~
Total MA. Hrs. Requi red: \ LID L. 1- devided by tooo
g a tt e r y S e lee t e d: L Z. ') \ L \J 1 A ~I
..:,."
equa 1 s [ . Y AH:
FIRE ALARM CONTROL PANEL
Model SK-2224
2-Zone Conventional Fire Panel
A simple, powerful, cost-effective panel for
basic fire protection applications
The SK-2224 is a two-zone, 24-volt conventional fire alarm control panel. Simple to install and
operate, this panel is the state of the art in small fire panels.
The SK-2224 provides a number of powerful features. Two Class B initiation zones, two 1.25 amp
notification circuits, and a 2.5 amp power supply are standard features. You simply cannot install more
power for the money! Other standard features include a half amp auxiliary power output for special
applications such as door holders; dedicated alarm and trouble relays; easy to use on-board
annunciator; and a compact cabinet that can house up to two 7.0 AH batteries.
Model SK-2224 .
2-Zone Conventional Fire Panel
The Silent Knight SK-2224
provides two Class B zones, two
1.25 amp notification circuits, and
a 2.5 amp power supply. Other
powerful features include a .5 amp
auxiliary power output and two
dedicated relays for alarm and
trouble.
Programmable features for zones
include alarm verification and
"enhanced" verification, that allows
pull stations to be recognized on
smoke verification zones, Zones
can also be programmed for zone
type (alarm or supervisory), and
water flow delay (30, 60, or 90
seconds). Notification appliance
circuits can be programmed for
silencing or no silence and for
ANSI or steady output. ~
The on-board annunciator is easy
to use and provides LED indication
of alarm, supervisory and trouble
conditions by zone as well as
system status.
Features
. Two Class B initiation zones
. Two power limited notification
circuits rated 1.25A each
. 2,5A power supply
. Dedicated alarm and trouble
relays
. Auxiliary power output rated
at .5A
. Alarm verification feature
. Enhanced verification feature
allows panel to recognize pull
stations in smoke verification
zones
. Communicator accessory
fits in cabinet
. Compact cabinet houses up to
two 7.0 AH batteries
. Notification appliance circuits
programmable for ANSI or
steady output
. Walk Test feature
· UL 864 listed, complies with
NFPA 72 and 101
. DIP Switch programmable
No programming software or
special tools required
Specifications
Primary AC
120 Vrms @ 60 Hz Order PIN SK-2224
230 Vrms @ 50 Hz Order PIN SK-4224HV
Total
Accessory Load 2.5A
, Current Draw:
Standby 50 mA
Alarm 250 mA
Model SK-2224
Dimensions
Height: 15 1/8"
Width: 12 13/16"
Depth: 3 318"
Color
Red
Optional Accessories
SK-2884 Serial Driver Board
Provides a serial interface with up to four
expansion devices (listed below).
SK-2104 Digital Dialer (Requires SK-2884)
ULlisted dual phone line DACT.
SK-2866 LED Annunciator
(Requires SK-2884)
Provides up to 12 LEDs for alarms,
supervisory, and trouble conditions,
SK-2880 I/O Module (Requires SK-2884)
Provides 34 pre-defined open collector
outputs, Two supervised switch inputs, and 3
form C relays.
~ SILENT
KNIGHT
8
FIRE ALARM CONTROL PANEL
Engineering Specifications
Model SK-2224
2-Zone Conventional Fire Panel
The contractor shall provide a completely electrically supervised fire alarm control panel Silent Knight Model
SK-2224. The system shall contain a fire alarm control panel capable of operating and supervising smoke detection devices,
alarm notification devices, and an on-board annunciator. It shall be compatible with a digital communicator accessory which
is housed in the control cabinetry.
The fire alarm control panel shall have a 2.5 amp power limited supply, two Class B initiation circuits which shall
accommodate heat detectors, smoke detectors, and manual pull stations, Smoke detection shall be achieved with either 2- or
4-wire detectors that are compatible with the system. The initiation inputs shall be programmable as 1) verification zones in
which detectors are automatically reset one time before signaling an alarm condition; 2) enhanced verification zones which
can recognize pull stations when smoke verification is in use in a zone and will signal an alarm immediately (will not reset) if
the alarm has come from a pull station; and 3) water flow delay zones in which the system waits 30, 60, or 90 seconds, as
programmed, before signaling an alarm condition. The FACP shall have two 1.25 amp notification outputs which are
programmable as silenceable or not silenceable and ANSI cadence or steady, The FACP shall be capable of supporting four
remote LED annunciators and shall have dedicated relays for alarm and trouble and an auxiliary power output rated at .5
amp.
The FACP shall have an on-board annunciator to indicate alarm, supervisory, trouble, and status conditions. The annunciator
must include LEDs for AC, GENERAL TROUBLE, SYSTEM SILENCED, WALK TEST, GROUND FAULT, AND LOW
BATTERY. The annunciator shall also contain LEDs to annunciate alarms, troubles, and supervisory by zone, The FACP
must be fully operational from the annunciator and include buttons for ACKNOWLEDGE, SILENCE, RESET, and WALK
TEST, The annunciator must also have separate DISABLE switches for each zone and notification circuit; SILENCE, RESET,
and WALK TEST,
To
communicator
accessory
To
remote
annunciator
Initiation Notification
Circuits eiroJits
(2 Class B) (2 Class B,
rated 1.25A each)
Trouble Alarm Aux. Power
Dedicated Relays Output
(.5 amp)
SK-2224 Block Diagram
~ SILENT
KNIGHT
.
7550 Meridian Circle, Maple Grove, MN 55369-4927
800-446-6444 or in Minnesota 612-493-6435
FAX: 612-493-6475
World Wide Web: http://www.silentknight.com
MADE IN AMERICA
FORM# 350380, Rev. 9/00
Copyright @ 2000 Silent Knight
", , i e- ,~ .< ! ~ 1 ~ , I
, FIRE CONTROL ACCESSORY
SK-2104
Digital Dialer
Expand the reach of your SK-2224, 4224 and 6324
with a reliable digital dialer.
Features
. Multiple reporting formats (SIA,
Sk3/1, Sescoa 3/1, Contact ID,
SK 4/2, Radionics BFSK),
. Four LEDs indicating, status,
dialer fail, line 1 trouble, line 2
trouble.
. Two phone line monitoring and
seizure circuits,
. Programmable dialing format
(Rotary or TouchTone).
. Transient Voltage protection on
the phone line inputs.
. Automatic daily test.
. Versatile two-number dialing
feature for reporting to two
different numbers.
. Easy, English-language
programming using the 5230
Remote Annunciator.
. EEPROM memory storage of all
programmed information.
· UL 864 listed for NFPA 72
Central Station Fire-Protective
Signaling Systems and Remote
Signaling Systems.
~ SILENT
KNIGHT
<!>
As the industry leader in digital communications, Silent Knight offers easy and reliable expansion of your SK-
2224,4224 and 6324 fire control panels. The SK-2104 provides fast, reliable digital communication of fire and
trouble conditions using ordinary phone lines. The compact design enables the SK-2104 to install inside the
same cabinet that houses the fire control panel. Programming is easy using the 5230 with english-language
display.
SK-2104
Specifications
Operating Voltage: 24 VDC
Current:
(while dialing)
70 mA
Model SK-2104
Digital Dialer
The Silent Knight SK-2104 is a
dual line digital communicator that
provides digital fire reporting over
ordinary phone lines, eliminating
the need for costly leased lines.
the SK-2104 is UL 864 listed and
NFPA 72 approved for Central
Station Fire-Protective Signaling
Systems and Remote Signaling
Systems, The SK-2104
communicates with the compatible
fire control panel via serial bus.
The SK-2104 has four on-board
LEDs that indicate the dialer
status, a dialer fail condition, and
the status of phone lines 1 and 2.
If an alarm, trouble or supervisory,
occurs at the control panel, the
digital dialer will seize the phone
line and communicate it to the
central station.
Accessory Devices
. Model 5230, used to program
the SK-2104
. Model 7860 modular cable with
spade connection to RJ31X.
. Model 2190 Accessory Cabinet
(used to remote mount the
Dialer)
Phone Line
Voltage:
Loop Resistance:
2.75 VDC Minimum
Data
250
250
250
+
Compatible
control panels:
SK-2224
SK-4224
SK-6324
Mounting:
Inside compatible
control panel cabinet
FIRE CONTROL ACCESSORY
..
Model SK-21 04
Digital Dialer
Engineering Specifications
The contractor shall provide an approved digital communicator to transmit the fire alarm and supervisory and
trouble signals to a central station. The digital communicator shall be UL listed for fire reporting to a central
station and shall conform to the requirements of NFPA 72. The communicator shall have the capability to
supervise two telephone lines, seize the phone line and send the alarm signal on one or both lines without the
addition of any more equipment. It shall indicate by LED if the telephone service is interrupted for longer than 45
seconds and it shall transmit a signal loss of phone line service to the central station over the remaining phone
line. A signal shall also be transmitted to indicate the restoral of phone service. The communicator shall be able
to report the loss of either phone line without regard to which phone line failed first. If both lines fail, a local
signal shall sound.The communicator shall have the ability to send a test signal to the central station every 24
hours. The test signal shall be able to be transmitted at a specific time of day or night. The communicator shall
be able to transmit all signals in the Standard SIA format (Security Industry Association). The communicator
shall be able to mount directly into the compatible control panel cabinet.
~ SILENT
KNIGHT
"
7550 Meridian Circle, Maple Grove, MN 55369-4927
800-446-6444 or in Minnesota 612-493-6435
FAX: 612-493-6475
World Wide Web: htlp://www.silentknight.com
MADE IN AMERICA
FORM# 350062, Rev. 9/98
Copyright @ 1998 Silent Knight
"
" FIRE ALARM ACCESSORY
Model SK-2884
Serial Driver Board
The power to expand your fire control
system is within your reach
Serial devices save you time and money when you install a fire system, especially if you're
performing an upgrade or retrofit. With the Model SK-2884 Serial Driver Board from Silent
Knight, you can expand the power and flexibility of your-compatible fire control panel-
applications without diminishing their most attractive benefit-fast, low-cost installation.
With the SK-2884, you can distribute up to four serial devices, such as SK-2866 annunciators
throughout a facility, adding accessibility your customers demand for a low price.
Model SK-2884 Features
Serial Driver Board
The SK-2884 is a serial · Adds up to four serial ~~I
interface board for a devices to a compatible fire ~,3f'lW
compatible fire panel, allows control panel
up to four expansion devices
to be added to the fire · Quick and easy to install
control system. It is required
if any expansion devices, · Plugs onto compatible fire
such as the SK-2866 LED }*-
annunciator, or 2104 digital control panel main board. t"
communicator, will be used · No additional housing Specifications
in an application. required. System Capacity: Compatible control
panels support one
SK-2884 Serial Driver
The SK-2884 is fast and · Low cost! Board.
easy to install-it simply The SK-2884
supports up to four
";""""'''plugs onto the control panel. · UL Listed, complies with additional expansion
Connecting expansion NFPA 72 devices.
devices to the SK-2884 is Ambient 320F to 12DoF
also simple, with only three Temperature: (DOC to 5DOC)
connections required. Compatible SK-2224
~ SILENT Panels: SK-4224
KNIGHT
Mounting: Plugs onto control
e panel board
III
ALARM ACCESSORY
Model SK-2884
Seriol Driver Boord
Engineering Specifications
The main control panel shall be compatible with a serial driver I interface board, model
SK-2884.
The interface board shall drive up to four compatible serial devices, such as the Model
SK-2866 LED remote annunciator. Connections between the interface board and the serial
devices shall be made through three wires. The interface board must be compact in size and
plug onto the main control panel. .
51-2866
',] 51-2884 I
.
~;;
..
.
-
~ SILENT
KNIGHT
e
7550 Meridian Circle, Maple Grove, MN 55369-4927
800-446-6444 or in Minnesota 612-493-6435
FAX: 612-493-6475
World Wide Web: http://www.silentknight.com
MADE IN AMERICA
FORM# 350067, Rev. 9/00
Copyright @ 2000 Silent Knight
GENTEX
12 or 24 VDC, Low Current Mini-horn,
Temporal (GX93) or Continuous (GX91)
tone, with Terminal Blocks
Applications
The GX91/GX93 Series mini-horn is a
high quality remote signaling appliance that
offers dependable remote annunciation.
The GX91/GX93 is listed for use with
both filtered and unfiltered power,
The GX91 is a continuous tone mini horn,
This unit is not synchable with the AVS44
control module. It is however synchable
from the panel.
With the GX93 a jumper is provided to
select either the continuous tone or the
temporal 3 evacuation tone.
The GX93 can be used on the same sync
circuit (AVS44) as other Gentex signals
such as the Commander series.
The GX91/GX93 appliances are UL 464
listed for use with fire protective systems
and are warranted for three years from the
date of purchase.
Standard Features
. Single Unit is capable of 12 or 24
VDC determined by the input
voltage
. Selectable Temporal 3 or Continuous
Tone on the GX93 (Jumper Pin)
. GX91 has a Continuous Tone horn
only
. Horn Frequency is 3100Hz
. Terminal Blocks (12 AWG to 18 AWG)
. Low Current Consumption
Available Models
. Variety of Mounting Options for New
Construction and Retrofit Applications
. To Synchronize the GX93 use the
Gentex AVS44 Control Module
. UL 464 Listed for Fire Protective
Service
. Textured Finish High Impact Plastic
Faceplate, Available in Fire Alarm
Red or Off-White
SERIES
GX91/GX93
Remote Audible Signal
Approvals
c@usl...e.
. BFP (City of Chicago)
. BS+A/MEA #285-91-E-XVI
. CSFM Listing 7135-0569:126
. UL ULC Dual listed 464
Horn In Anechoic In UL Reverberant
Model Part Input Current Room dBA Room Per
Number Number Voltage Range (mean DC) @10Ft. UL 464 @ 24 VDC
GX91R 904-1274 8-33 V 4-17mA 90 i 85 dBA
i
GX91 W 904-1275 8-33 v 4-17mA 90 85 dBA
GX93R 904-1276 8-33 v 5-25mA 90 I 81 * dBA
GX93W 904-1277 8-33 V 5-25mA 90 81 * d BA
Input Voltage Range: 8-33 VDC OR VFWR Operating temperature
Indoor. 320 to 1200F 00 to 490C
GX91 Average Horn Current is 15mA @24VDC GX93 Average Horn Current is 22mA @24VDC
· The sound output for the Temporal 3 tone is rated lower since the time the horn is off
is averaged into the sound output rating. While the horn is producing a tone in the
Temporal 3 mode its sound pressure is the same as the continuous mode.
uR" = Red faceplate
W = Off-'M1ite faceplate
.
GENTEX
Dimensions
@
.1'4
.fJI
1M
4.7lI
U.
UmD
carnn
PAlm.
-.sa
o
+
I'flI:l/lS
1GWt.
I'!:1.JT
\
FfiI
1If[l
RED
~K BUOC
Wiring DiagrMl
'I'IRlG IlIMIWl ~aw. 0I.JlM . OIll:UI'IwmiA8IrU.AW144 CCIH'I1II:II. WCIlClLl
PMJI,
IlCIW.. c.o.rn!I
24 units per carton
6 pounds per carton
GENTEX
CORPOI=IATIDN
Fire Protection Products: www.gentex.com
10985 Chicago Dr., Zeeland, MI 49464
616/392-7195 1-800/436-8391 FAX: 616/392-4219
Gentex corporation reserves the ri9ht to make changes to the product data sheets at their discretion.
SERIES
Mounting
--
(0
CO
SGP-R SGP-W
Trim Plate for GX91/GX93
Architect & Engineering Specifications
The alarm horns shall be Gentex Model
GX91/GX93, The appliance shall be listed with
Underwriters Laboratories for use with Fire
Protective Signaling Systems and produce a
peak sound output of 90dBA or greater as
measured in an anechoic chamber. The
appliance shall be of solid-state constructi?n
and be polarized to operate from 8-33 VDC With
a 15 milliamp current drain on the GX91 and a
22 milliamp current drain on the GX93 at 24
VDC. The appliance shall ~e provi~ed with 2
terminals, and mount to a variety of Single-gang
back boxes.
o Printed on Recycled Paper
GX030101-3
Heat Detectors
Series 600
The Heat Detectors SerIes 600 are supplied
with the fo/lowing standard features:
· Rate-of-Rise and Fixed Temperature
· One or Two-Circuit, Normally Open
· Easy Installation
· Low Profile
· Visuallndicarion
· Operation Testing
~ D~~9rip~ion .'. .... '.' '. . "'.,.. '. -. . ." _..' .: ,: .:(~;':.. ....,
The Series 600 Heat Detector is attractive, durable and
features combination rate-of. rise and fixed temperature
operation. Heat detectors are available in 135<'F and 20Q'F
temperature ratings,
Rate-of-rise detects heat by quickly responding to a rapid
temperature increase. Rate.af-rise units have a wide spacing
allowance of 50. foot centers. See specification table for
details.
Fixed temperature reacts to heat by responding to a specific
temperature setting.
Series 600 Detectors use tile same reliable pneumatic rate-of-
rise element of former models, but offer added aesthetic
appeal.
TI1e pneumatic rate-of-rise element responds to a rapid rise in
temperature, approximately 15<'F, (8"C) per minute, by
expansion of air witllin the scaled chamber faster than it can
escape through a calibrated vent. The resultant incrsass in
pressur~ depresses the diapllragm, causing the electrical
contact to close tile circuit.
The fixed temperature element uses a fusible alloy, WIlen
activated, the external heat collector drops 6lway to provice
quick visual confirmation that the element has operated,
The units protrude only 1-3/8 inch from tl,e ceiling suria:::e with
a junction box rnounting. TIley have pleasing contOLlrs and an
all.white finish that conforms to ceiling aesthetics.
Installation
Each detector includes a patented reversible mounting plat~.
In one position, it easily attaohes io 4" square junction box,
3.25" or 4" octagonal box, or plaster ring.
In reverse, the plate can be useel for open wiring withOut a
junction box. A 1/4" space bet\vean detector and mounting
swiace allows for wire connections. All mounting screws are
concealed.
The detector attaches easily to the mounting plate with a push
and twist motion. No tools are required,
l!rL- .
AI rlo~t; ";s~rvad (1 o:n:,
-_.~
Junction Sox MQunting
I\___~: ,+a.
-t-4.9:16M_~
3.1/4"or4"
Octagons/ 80x 9r
4" $qutm Box 7
/--rry-'-/
~. Revsrsibls
. I Movnring
.0, Plale7
. ,/
~
~-W
---1,
--=--:..:.........
/::::----.::~.~" 8-32"
// -......:"
V/ ~ Round
~ ) Head
.. _ >" SerliN,S
-..... r;-'-=-~:,,\ ,-- 5. ''8 t 1 "
....._~___. I Q
Ceiling $urf<lce Mounting
t fi ~
2.W)" I. '
i ----....-,~
eLlr for Sl)r"~ce Rsversible
mOLlntIng 1 ~~127
I I
! /['-~-. !
r--_I_/",'........:..> I
/r---+.,,/ ~~\
P ).----=::::.~-. I" 0.-
/1 ;;'/';:'-;;k~~~ ~~
( r~? .,-- --.. \
'\ \:t~~rJ'
~---==------/1\
.-----==--==..:::---.i 8.3""
(/~>-------~1 Flat
I .Ye:ad
\ ~ / ~OOd
......._. ti-::----"-\, ..../ .,;.crews
--.:J.~~~.
Mounting plate is molded of white self-extinguishing thermo-
plastic rated at 221 ' F (1 OS"C). The plate is extremely strong
yet adapts to uneven mounting surfaces,
Series 600 Testing MethOds
Models 601/621 and 6021622 can be tested by the quick.
application of heat from any convenient SOlJrce. A pOl1able hair
dryel'is recommended. However, do not apply heat that
exceeds the fixed temperature rating of the detector,
Models 603/623 and 604/624 cannot be tested, However, the
fusible alloy element used is considered so reliable that testing
is not necessary.
IIU
r-u;;Lf/.L::l::l:l .L,j:Lij
!
::,tjij-L,;:i.L::,;':,:l (
I...:HtJ'l1:. i l'<UNll...::::'
I-'AGI:. lj:'::
. '
'C...I...I!IrI.........,. . ' ,
..emelrOn,CS@ , Elfe(:illlp.:OctobCr.t~98.
Model 601 and 621
No Marklng . 0
Model 601 (1 circuit)
Model 621 (due circuit)
ModeJ 602 and 622
Gray Ring . 0
Model 602 (1 circuit)
Model 622 (dual circuit)
Rate-of-Aiseand rlxed
Temperature, 13S"F (51"C)
Applications: Normal
temperature fluctuations
and ceiling temperatures
not exceeding 100.F (3B"C)
Maximum Spacing
Allowance" .
50 x 50 ft. - UL
30 x 30 ft - FM
RatEi-of-R:se and Fixed
Temperature, 2000F (940C)
Appllcatlons: Normal tempe-
rature fluctuations and ceiling
temperatures exceeding 100"F
(380C) but not 150'F (660C)
Maximum Spacing
Allowance" -
50 x 50 ft. - UL
30x30ft.-FM
Model 603 and 623
Gray Spot r;\
Model 603 (1 circuIt) V
Model 623 (dual circuit)
Model e04 and 624
Gray Ring and Dot ~
Model 604 (1 circuit) ~
Model 624 (dual circuit)
Fixed Temperature only. .
135'F (57"C)
FIxed Temperature only,
200.F (94"C)
Applications: Unusually violent
temperature fluctuatIons
and ceiling temparatures
not exceeding 1 OO.F (38.C)
Appllca.tlons: Unusually violent
temperature fluctuations and
ceiling temperatures exceeding
100.F (38"C) but not 1500F (6soq
Maximum Spacing
Allowance' -
25 x 25 ft, - UL
20 x20 ft. . FM
Maximum Spacing
Allowa.nce' .
15x15ft.-UL
.R~fer 10 N;;:iQn~' Fire A:arlTl Code S;and~rd NFPA 7210: 8Dl>lIcatlOn r~qui'~"",,~c.~
Screw Terminals
standard Single
Circuit Detector
Duel CIrcuIt Detector
Used to send two Inde.pendent
$lgn~ls.
Wife from alarm
panel Dr previous
d,na(f)ctor.~
,e
lw.f~,
.1
~
Wire connl3cted ~
to next detector
or end of line
resistor.
Wire connected 10
next detector or-:;::;-;:;
end of /in; resistor. ~~\ '~~ ;)/>
~\; ,.~..
Wire from alarm
~~~:~t~~preVious "'~~)
ff-e
3
Wire connected
to next detector
or end of line
resistor.
NOTE: All single,
circuit models come
with one (1)
normally open dry
contact.
NOTE: All dual circuit models
corns with one (2) normally
open dry con/acts.
Important Special Notes
Application: Heal detectors should be used for property
protection. Reliance should not be placed on heat detectors for
Life Safety.
CAUTION: When life safety Is Involved, smoke detectors
MUST also be used. Detectors must not be painted.
Battery Back-Up: Heat detectors should be electronically
supervised with battery back-up at the panel.
The rate-of. rise mechanism may be subject to reduced
sensitivity over tIme, Annual testing of the rate-of-rise mecha-
nism is recommended.
Electrical Ratings
6-125 Volts A.C.. 3.0 Amps.
6.28 Volts D.C., 1.0 Amps.
125 Volts D.C" 0.3 Amps.
250 Volts D.C., 0.1 Amps,
listings/Approvals
· Listed by Underwriters Laboratories (UL)
· Factory Mutual Approved (FM)
· California State Fire Marshal Approval (CSFM)
· City of New York (MEA) Listing No. 188-94-E
· Listed by Underwriters' Laboratories of Canada (ULC)
This literature Is provided for infOnilatlonal purposes only, CHEMETRONICS assumes no responsibility for the product's suitability for a
, particular application. The product must be properly applied to work corr.act!y, If you need more Information 011 this product. or if you have a
i particular problem or question, contact CHEMETRONICS. LuquillO, Puerto Rico; Telephone (800) 496-8383.
I
---
uwn
FACTORY:
Chemetronlcs, Caribe Inc.
P.O. Box 779, Rt. 992, Km. 0.2
Luqulllo, Puerto RicO 00773 USA
Phone: (800) 496-8383
Fax; (800) 496-7272
SALES OF~ICE::
Chemetronics
400 Main Street
Asllland, MA 01721 USA
Phone: (508) 881-2000
~ax: (508) B81-6729
L
All ,ignl~ rese'V9o {1C:~Si.
1 r
117
~ . @
FIRE ALARM SYSTEMS
NEW AND IMPROVED
Description:
Wheelock's Series MT and MT Strobe Multitone electronic
appliances offer a choice of eight (8) nationally and
internationally recognized alerting sounds: Horn, Bell,
March Time Horn, Code-3 Tone, Code-3 Horn, Slow
Whoop, Siren or Hi/Lo Tone. The Code-3 Horn and tone
patterns are engineered to comply with NFPA/ANSI
Temporal Pattern specifications without requiring additional
equipment. With MT and MT Strobe appliances, one alarm
appliance meets most of your signaling needs. Strobe
models can be synchronized using the Wheelock SM,
DSM Sync Modules or the PS-12/24-8 Power Supply with
Wheelock's patented Sync Protocol.
The MT Strobes are designed for ADA applications with
maximum performance, reliability and cost-effectiveness
while meeting or exceeding the latest requirements of NFPA
72, ANSI 117.1, UFC and UL Standard 1971 as well as
meeting ADA requirements concerning photosensitive
epilepsy.
Each MT and MT Strobe appliance has two installer
selective sound output levels: STANDARD dBA and HIGH
dBA. Non-strobe versions provide selectable voltage
capability in one unit, 12VDC or 24VDC. Strobe versions
are specific for either 12VDC or 24VDC and all models
may be used with filtered or unfiltered (full-wave-rectified)
input voltages. Separate input terminals are available,
shunt wires are provided to enable both tone and strobe to
operate simultaneously from a single input.
The Series MT Multitone Strobe appliances are UL Listed
for indoor wall mount applications under Standard 1971
for Signaling Devices for the Hearing Impaired and under
Standard 464 for Audible Signaling Appliances.
MT4-115-WH
SERIES MT w/o
STROBE
For Weatherproof MTWP See Data Sheet S9004
Copyright 2002 Wheelock, Inc. All rights reserved.
SERIES MT AND MT STROBE
MUL TITONE ELECTRONIC APPLIANCES
SERIES MT STROBE
Mounted to lOB
Features:
. Approvals include: UL Standard 1971, UL Standard 464,
California State Fire Marshal (CSFM), MT with new strobe,
and New York City (MEA). Pending: Factory Mutual (FM)
and Ghicago (BFP), (MT-12/24 approved by all)
. Designed to meet or exceed ADNNFPNUFC/ANSI
Standards and Accessibility Guidelines.
. Complies with OSHA 29, Part 1910.165,
. Series MT appliances have IN and OUT wiring
terminations that accept two #12 to #18 American
Wire Gauge (AWG) wires at each terminal. Inputs
are polarized for compatibility with standard reverse
polarity type supervision.
. One alarm appliance with (8) eight selective signals
to provide superior sound penetration for various
ambient and wall conditions with two field selectable
sound output levels.
. Code-3 Horn and Tone meet ANSI/NFPA temporal
pattern for standard emergency evacuation' signaling.
. Audible and strobe can operate from a single NAC
circuit with any of the (8) eight audible sounds.
. MT Strobe models available with 15/75 and 75
candela ratings for independent or single input
activations and can be synchronized using
Wheelock's SM or DSM sync module(s) or the
PS-12/24-8 Power Supply with built in Wheelock
Sync Protocol.
. Selectable input voltage on non-strobe versions.
Strobe versions are factory set for either 12 or
24VDC, with wide-Listed voltage range, filtered (DC)
and FWR.
. Mounts to either 4" square or double gang boxes
(important for retrofit installations). Attractive flush or
surface mounting.
. No additional trimplate required for flush mounting.
. .
NOTE: All CAUTIONS and WARNINGS are identified by the symbotA . All warnings are printed in bold capital letters.,:,
A WARNING: PLEASE READ THESE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,
SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS AND
WARNINGS COULD RESULT IN IMPROPER APPUCATION, INSTALLATION AND/OR OPERATION OF THESE . ..
PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR
DEATH TO YOU AND/OR OTHERS.
General Notes:
. Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range". Note that NFPA-72
specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specifies a flash rate of 1 to 3 flashes per second.
'AII candela ratings represent minimum effective Multitone Strobe intensity based on UL Standard 1971.
. MT Strobe models are UL Standard 1971 Listed for indoor use with a temperature range of 320F to 12DoF (DOC to 490C) .and
maximum humidity of 93% i:2%, The MT-12/24 and MTWP models for outdoor use are Listed for -31 OFto.150oF (-350C to 660C)
and maximum humidity of 95% (See Data Sheet S90D4 or Installation Instruction Sheet P84150 for more detail on MTWP).'
. MT Audible is UL Standard 464 Listed.
. "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used
the terminology "Listed Voltage Range".
ALARM TONES
ALARM TONES
TONE PATTERN DESCRIPTION
HORN BROADBAND HORN (Continuous)
BELL 1560 Hz MODULATED (0.07 sec. ON/Repeat)
MARCH TIME HORN HORN (0.25 sec. ONJO.25 sec. OFF/Repeat
CODE-3 HORN HORN (ANSI S3.41 Temporal Pattem)
CODE-3 TONE 500 Hz (ANSI S3.41 Temporal Patlem)
SLOW WHOOP 500-1200 Hz SWEEP (4.0 sec. ON/0.5 sec. OFF/Repeat)
SIREN 600-1200 Hz SWEEP (1.0 sec. ON/Repeat)
HI/LO 1000/800 Hz (0.25 sec. ON/Alternate)
Table 1: dBA and Current Ratings for Multitone Audible Portion
Average Current Ratings (AMPS)" dBA Reverberant Ratings dBA Anechoic Ratings
Tore Per UL 464
@ 24 VDC @ 12 VDC @ 24 VDC @ 12 VDC @ 12 and 24 VDC
HI S10 HI STD HI S10 HI S10 HI S10
Horn 0.038 0.024 0.095 0.019 92 87 90 77 99 93
Bell 0.019 0.012 0,030 0.010 86 80 85 69 92 87
March Time Horn 0.038 0.024 0.095 0.019 89 84 89 74 99 93
Code-3 Horn 0.038 0.024 0.095 0,019 88 83 88 73 99 93
Code-3 Tone 0.027 0.016 0.057 0.014 85 80 84 70 95 90
Slow Whoop 0.047 0.025 0.095 0.024 90 89 89 75 99 94
Siren 0.034 0.022 0.078 0.019 89 84 89 75 98 93
HIJLO 0.020 0.013 0.042 0.011 86 81 86 71 93 88
Table 2: Strobe Current Ratings (AMPS)
UL Average Current Ratings (AMPS)"
12 and 24 VDC
Voltage Range Mf-241575W Mf-2475W Mf-121575W MlWP2475W
16.0 VDC .094 205 - .150
24.0 VDC .065 .133 - .102
33.0 VOC .053 .109 - .086
8.0 VOC - - .319 -
12.0VDC - - .170 -
17.5 VDC - - .130 -
'A WARNING: 12V MULTITONE STROBE MODELS SET ON
STANDARD dBA DO NOT MEET THE 75 dBA MINIMUM UL
REVERBERANT SOUND LEVEL REQUIRED FOR PUBUC MODE
FIRE PROTECTION SERVICE (NOTED BY * IN TABLE 1).
MODELS WITH SEmNGS WHICH PRODUCE LESS THAN 75
dBA MAY NOT BE HEARD. THIS SEmNG IS ACCEPTABLE
ONLY FOR GENERAL SIGNAUNG (NON-ARE ALARM) USE.
USE THE "HIGH" dBA FOR PUBUC MODE SERVICE.
Note: If the strobe and audible operate on the same
circuit, add the strobe current from Table 2 to. the
audible current from Table 1. For Peak and Inrush
current across the listed voltage range refer to
Installation Instructions.
# Average Current per actual Wheelock Production Testing at
listed VDC. For rated average and Peak current across the UL
listed voltage range for both filtered DC and unfiltered VRMS
see Installation Instructions
~
..
I
I
I
I
Wiring Diagrams (for all models)
MT SIGNAL AUDIBLE SIGNAL AND STROBE
OPERATE INDEPENDENTLY
FROM +~+ TONEXT
PRECEDING - _ APPLIANCE OR
APPliANCE. EOlR
SMIOSM.
PS-t2l24-8
POWER SUPPI. V
orFACP +-
SIGNAL
:~EO"'G +
AUOIBLE OR _
,ACt>
AUDIBLE SIGNAL AND STROBE
OPERATE IN UNISON. RED AND
BLACK SHUNT-WIRES ARE
SUPPLIED.
+ 10 lOT
_ AUDIBLE OR
O"'A
'A""
=~:~E~ +
........
PS-12f2.o1-11
PQWERSUPP!.y
OA
FACP
+ TONElCT
STROBE OR
- EOlR
FROM + + TO NEXT
PRECEDING =tf... . '. . APPLIANCE
APPLIANCE - . OR EOLR
OR FAC? IL"CIl.
.' + - 11& + ,_ .
STROBE AUOlel.E
Specifications and Ordering Information
Model Number Order Code Input Voltage Rated Candela Mounting Options'"
MT-12124' 5023 12/24 - D,E,F,l,M,O,P,R
MT-241575W-FR' 8422 24 15 (75 on AXIS) D,E,F,l,M,O,P,R
MT-2475W-FR 9475 24 75 D,E,F,l,M,O,P,R
MT-121575W-FR' 8421 12 15 (75 on AXIS) D,E,F,l,M,O,P,R
MTWP-2475W-FR" 8420 24 75" (@ -31OF/-35OC) M
MT4-115-R 6223 115VAC - D, E, J, K, N, 0, R
MT4-115-WHVFR'" 6224 115 VAC 15 D, E, J, K, N, 0, R
SYNC MODUlES.... Average Current
(AMPS)
SM-12/24-R 6369 12 OR 24 .017/.028 W
DSM-12/24-R 6374 12 OR 24 .0201.035 W
NOTE: 'MT-12/24 Audible can be used with Wheelock's RSSP Multi-Candela for applications requiring 15,30,75,
110 cd Wall Strobes. . .
"MTWP-2475W is Weatherproof and rated for 75 cd @-310F (-350C). See Data Sheet S9004 or Installation Instruction P84150.
'''For additional information on mounting please refer to Data Sheet S7000.
.....SM Sync Modules are rated for 3.0 amperes at 12/24 VDC; DSM Dual Circuit Modules are rated for 3.0
amperes per circuit. Maximum number of interconnected DSM modules is twenty (20). Refer to Data
Sheet S3000.
# Use MT-241575W or MT-121575Wwhen 15cd is specified. 15/75 is UL Listed for 15cd with 75cd on AXIS.
## Series WH Strobe is listed for UL Standard 1638 only. See Instruction Sheet P83159,
A WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" P82467 MT-12124, P84155 MT wI
Strobe P84150 MTWP WEATHERPROOF "GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS
DO UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE
MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE
PRODUCTS, INCLUDING:
- TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES.
- FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON
THOSE CIRCUITS.
- COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW.
- THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED INPUT VOLTAGE RANGE.
-INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES.
-USE STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBE ON
CODED OR INTERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBE MAY
NOT FLASH.
-FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT
IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY
SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS.
- CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND
INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS.
Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, ~perated,
maintained and operationally tested in accordance with their installation instructions at the time of installation and at least tWice a y,ear
or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation,
operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all ofthe latest
National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEe), Occupational Safety
and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards,
guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the
local authority having jurisdiction (AHJ).
. <
.
ARCHITECTS AND ENGINEERS SPECIFICA TIONS
The notification appliance shall be a Wheelock Series MT audible/visual appliance or equivalent. Notification appliance shall
be electronic and use solid state components. Electromechanical alternatives are not approved. Each electronic appliance
shall provide eight (8) field selectable alarm tones. The tones shall consist of: HORN, BELL, MARCH TIME HORN, CODE-3
HORN, CODE-3 TONE, SLOW WHOOP, SIREN and HI/LO. Tone selection shall be by durable dip switch assembl{alidnot
clips or jumpers. The Multitone Audible appliance shall be UL Listed under Standard 464 for Audible Signal Appliances. The
audible and the strobe shall be able to operate from a single NAC circuit while producing any of these tones. The appliance
shall provide two output sound levels: STANDARD and HIGH dBA. The HIGH dBA setting shall provide a minimum 5 dBA
increase in sound output at nominal voltage. The HIGH anechoic dBA measurement at 10 feet at the alarm HORN SETTING
shall be 101 dBA minimum for MT 'and 92 dBA minimum for MT Strobes, at nominal voltage. Operating voltages shall be either
12 VDC or 24 VDC using filtered power or unfiltered power supply (full-wave-rectified). All models shall have provisions for
standard reverse polarity type supervision and IN/OUT field wiring using terminals that accept #12 to #18 AWG wiring..
Combination audible/visual appliances shall incorporate a Xenon flashtube enclosed in a rugged Lexan@ lens or equivalent
with solid state circuitry. Strobe shall produce a flash rate of one (1) flash per second minimum over the voltage range.The
strobe intensity shall be rated per UL and Listed under Standard 1971 for Signaling Devices for the Hearing Impaired for
15/75 or 75 candela. The 15/75 candela strobe shall be specified when 15 candela or with 75 candela intensity on-axis is
required. Strobe Models shall incorporate circuitry for synchronized strobe flash and shall be designed for compatibility with
Wheelock SM and/or DSM Sync Modules or Wheelock's PS-12f24-8 Power Supply with Sync Protocol. The strobes shall not
drift out of synchronization at any time during operation.lfthe module fails to operate (i.e., contacts remain closed), the strobes
shall revert to a non-synchronized default flash rate.
All Listed strobe appliances shall incorporate low temperature compensation to insure the lowest possible current consumption.
Strobe activation shall be via independent input or from the same input circuit as the audible.
The combination audible/visual appliances shall be installed indoors and may be surface or flush mounted, They shall mount
to standard electrical hardware requiring no additional trimplate or adapter. The aesthetic appearance shall not have any
mounting holes or screw heads visible when the installation is completed. The appliance shall be finished in a textured red
color.
The Series MT-12f24'audible appliance may be installed indoor or outdoor with the proper back box.
For Weatherproof applications where specifications require 75 cd @ -31 OF (-350C) and full temperature range
of -31 OF to 1500F refer to Data Sheet S9004 andfor Installation Instructions P84150.
NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance
with Wheelock Inc. standard terms and conditions.
WE SUPPORT AND ENCOURAGE NICET CERTIFICATION
MADE IN THE USA
3 YEAR WARRANTY
National Sales Office
800-631-2148
Canada 800-397-5777
E-Mail: Info@wheelockinc.com
http://www.wheelockinc.com
Distributed By:
... ~i.---~":i"'i
J. .. r _
I::~?
273 BRANCHPORT AVENUE. LONG BRANCH, NJ 07740 . TEL: 732-222-6880 . FAX: 732-222-2588
S2000 06102
~
..
. :':; j DESCRIPTION
The Model 4050 Fire Alarm Station is made of rigid metal
and is finished in red with a red faceplate and raised
lettering. The station can be surface mounted or semi-
flush mounted using an optional back box. To convert to
a dual-action station, an optional breakaway shield made
of clear plastic with lettering reading "LIFT TO BREAK -
PULL LEVER DOWN" is available.
APPLICATION
Model 4050 manual fire alarm stations are recommended
for use in hotels/motels, hospitals, schools, apartments,
office buildings, industrial plants, and any other
application where manual alarm initiation is required. The
station's attractive appearance, durable construction, and
variety of mounting options allow it to fit most any
application.
Model 4050 Pull Stations carry the following listings!
approvals:
AtJency
Underwriter's Laboratories
California State Fire Marshal
New York City
Reference Number
84875
7150-0811 :115
MEA 11-92-E
STANDARD FEATURES
· Easy access for inspection permits opening of station
without interrupting the fire alarm circuit nor initiating an
alarm.
· Choice of mounting. Surface mounting or semi-flush
mounting over backboxes with or without plaster ring.
· Non-coded.
· UL Listed, CSFM, NYC approved.
OPTIONAL FEATURES
· Break-away shield adds a dual-action station feature
to deter false alarms.
· 4050 fire alarm station is available with switch contact
arrangements to meet virtually any fire alarm signaling
requirement.
'11
FEDERAL SIGNAL CORPORATION
Commercial Products Group
Manual Fire Alarm Stations
Model 4050
Model 4050 Manual Fire Alarm Station
SPECIFICATIONS
Manual fire alarm stations shall be capable of being
surface or semi-flush mounted. When operated, fire
stations shall remain mechanically locked until manually
reset. Fire alarm station shall be constructed of metal
with raised lettering and shall have a red finish. Manual
fire alarm stations shall be Federal Signal Model 4050.
FireLarm™ Systems
FL-4050
In~
"
..
,
ORDERING INFORMATION
Part Number Description
4050 OOH Single Action Pull Station, Red. 4-Wire Pigtails
4050 211T Single Action Pull Station, Red. Terminals
8462 657 Break Shield, Converts Station to Dual Action (2pack)
4050BB Surface Mount Back Box, Red, 1.5" Deep
..' Model 4050 Pull Station Specifications
Model Contact Ratings Dimensions Weight
4050 6.0A at 24VDC Resistive Load 5W'H x 33fa'W x 1 "D 0.80Ibs.
3.0A at 24VDC Inductive Load
4050BB nla 5W'H x 33fa'W x 1W'D 0.75 Ibs.
MOUNTING OPTIONS
SEMI-FLUSH MOUNTING
SURFACE MOUNTING
STANDARD
&0:> ~ 0 "0:>
, ID~~~D I'
l~ , 0 lV l~'
~lA~[M]
k- 3-3/8" ~ ~ 1"-4-= 2-1/2" ~
1/2" KNOCK OUT~.,
TOP & BOTTOM ,
[F~~~
~
I-
2 ,..."
::Jx~
000
:::!:CCLO
w~~
<.J<.J
<(<(2
l.L..cc'
ct: Q...
::J ........
Ul
D~~ ~D
~
~lA~[MJ
~ 3-3/8" ~
~ 1"-+1-1/2.~
BREAK SHIELD
(p /N 8462 657)
o
LIFT TO BREAK
PULL LEVER DOWN
LFT
FireLarm™Systems
FL-4050 (09193)
FEDERAl SIGNAL CORPORATION
1M FIRELARM
Cl FEDERAL SIGNAL CORPORATION. 1993
APPEARANCE DETAILS ARE SUBJECT TO
IMPROVEMENT WITHOUT NOTICE
r.,
FEDERAL SIGNAL CORPORATION
Commercial Pl'llductB Group
1130 MIlepost Drive
Columbus, Ohio 43228
6141870.66n . FAX 6141870-6975
. PERMIT
e
'"
CITY OF BREMERTON BUILDING DEPARTMENT
PHONE: 478-5281 37RS-00Q.,.003-0003
JOB ADDRESS
1608 Bllr"'lell Apt #5
OWNER
MAl L ADDRESS
ZIP
PHONE
George Hilbert
CONTRACTOR
MAIL ADDRESS
PHONE LICENSE NO.
A&M Heating
Class of work: D NEW
PO BoxD, Bremerton
D ADDITION D ALTERATION
373-1766
D REPAIR
D. MECHANICAL D PLUMBING
CHIMNEY (No fee information only) INSPECTION: Groundwork .' . Gas Test
Masonary Lines '. Unlined Wasted Vents Water'
Factory Mfg Type B Type L , Htg. Ruffin Chimney
Location: Internal Outside Wall 'Stove or Insert Refrig.
No, Type of Equipment Fee. "No, Type of Fixture or Item Fee
STOVES Gas_ Oil_Woo~ WATER CLOSET (TOILET)
FIREPLACE INSERT BATHTUB
FURNACE' Gas (NaCJL LPG._) Oil_ LAVATORY (WASH BASIN)
Wood add on' _ Other_ Electric_ SHOWER
BTU 19,000 KITCHEN SINK & DISP,
Type: Up flow_ Down f1ow_ DISHWASHER
Horizontal~ Wall_ 600 LAUNDRY TRAY
CONVERSION !'WRNER: Gas_(Nat._ LP~) CLOTHES WASHER
Under 100,000_ Over 100,000_ 'WATER HEATER
Oi~ URINAL,
UNIT HEATERS BTU_ Gas_ Elec._ , DRINKING FOUNTAIN
BOILER Gas~ Oil_ ,Electric_ . FLOOR - SINK OR DRAIN
Other~ H P ~ SLOP SINK
GAS SYSTEM Max. 5 outlet Total----L ? 00 WATER PIPING & TREATING EQUIP.
EVAPORATION' COOLERS Roof_ Wall_ WASTE INTERCEPTER (Grease)
BTU~ VACUUM BREAKERS & BACKFLOW DEVICE
AC UNIT Electric_ Gas Elec. Combo LAWN SPRINKLER SYSTEM
BTU_ SWIMMING POOL - Private Public
HEAT PUMP Single Package_ SpliL- GROUNDWORK
Add on~ BTU Ton_ SUMP
MIXING OR REHEAT BOX CFM_ BTU_ ALTERATION
AIR HANDLING UNIT CFM_ BTU_ POST & BEAM
FANS ExhausL- Supply_ Bath_
RANGE HOOD Residential_ Comm._ PERMIT $
CLOTHES DRYER Res.~ Comm._ TOTAL $
Incinerator NOTICE
ALTERATION TO DUCT SYSTEM THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHOR-
Heating/Cooling_ ExhausL- IZEDIS NOT COMMENCED WITHIN 120 DAYS. OR IF CONSTRUCTION OR WORK IS
TANKS Oil_ Gas_ Propane w/OK SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT ANY TIME AFTER
from Fire Dept.,---- Gallons_ WORK IS COMMENCED.
REFRIGERATION UNIT I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND
KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND
ORDINANCES GOVERNING THIS TYPE OF WORKWILL BE COMpLIED WITH WHE-
PERMIT $ 1n nn THER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRE-
TOTAL FEE $ 1Q nn SUME TO GIVE AUTHQRITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY
OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFOR
MANCE' OF CONSTRUCTION,
. (JCM..CO~
SIGNA TURE OF CONTRACTO OR AUTHORIZED AGENT
("-,^'3vfJ
(DA TE)
FINAL APPROVAL
, (SEE OTHER SIDE)
RECEIPT NO.
SIGNATURE OF OWNER (IF OWNER BUILDER) (DATE)
PERMIT NO. ~
75112
'(White-ORIGINAL, Yellow-INSPECTOR, Pink-APPLICANT)
INSPECTION REC.D CARD
CITY OF BREMERTON BUILDING DEPARTMENT
ADDRESS & DIRECTIONS
1608 BURWELL APT. #5
.
2921
PERMIT' NUMBER
OWNER GEORGE HUBERT
CONTRACTOR A&M HEATING
PHONE
PHONE
373-1766
1 FOUNDATION
CORR O.K.
1, PERMIT ON SITE --
2. CHECK PLANS TO PERMIT --
3. CHECK SETBACKS --
4, PROPERTY STAKES --
5, FOOTING SIZE CORRECT --
6, WALL SIZE CORRECT --
7. CHECK FOR FILL --
8. REQUIRED STEEL IN PLACE --
9, CHECK FIREPLACE FOOTING --
10, ANCHOR BOLTS --
11. FOUNDATION PLATE --
12. FOUNDATION VENTS --
13, CRAWL SPACE ACCESS --
FOUNDATION INSPECTION APPROVED
BY:
COMMENTS:
2 FRAMING COMMENTS:
CORR O.K.
1, WIRING APPROVED --
2. FOUNDATION VENTS --
3. SHIELD UNDER POSTS --
4. POSITIVE CONNECTIONS --
5, SOIL TO WOOD CLEARANCE --
6. POST CLEARANCE - 2" --
7. BEAM SUPPORT --
8, TR. MAT. NEXT TO CONC. --
9. WASHERS ON ANCHOR BOLTS --
10. BEAMS PROPER SIZE --
11. FLOOR JOISTS 9PAN --
12, NOTCHING & DRILLING --
A-FLOOR JOISTS --
B-STUDS --
13. STAIRS --
A-WIDTH --
B-RISE & RUN --
C-WINDERS --
D-LANDINGS --
E-HEADROOM --
14. ATTIC VENTILATION --
15. CHIMNEY STRAPS SECURED --
16. FIREPLACE COMBUSTION AIR --
17, FANS VENTED OUTSIDE ---
18. A-BATHROOMS --
B-LAUNDRY ROOMS --
C-KITCHEN --
18. WATER CLOSET CLEARANCE --
19, SMOKE DETECTOR --
FRAMING INSPECTION APPROVED
BY:
CORR O.K.
20, FIREBLOCKING _ _
A-STAIRS _ _
B-DROP CEILINGS _ _
C-TUBS OR SHOWERS _ _
D-ROOF & CEILING LINES _ _
E-FURRED OUT AREAS _ _
F-FIREPLACE AT CEILING _ _
G-ELECTRICAL HOLES PLUGGED_ _
H-PLUMBING HOLES PLUGGED__
I-LID IN VOIDS _ _
21, WINDOWS
A-SAFETY GLAZING
B-VENTILATION
C-REQUIRED FIRE EXITS
D-WINDOW SILL HEIGHT
22. CEILING HEIGHTS
A-BASEMENT
B-MAIN FLOOR
C-UPPER FLOOR
23. SWAY BRACING
24, TRUSSES
A-PROPERLY INSTALLED
B-STAMPED
25, ATTIC ACCESS
26. CEILING JOIST SPANS
27. RAFTER SPANS
28. ROOF SHEATHING
29, ROOFING APPLICATION
30. . SIDING
31, CLOTHES CHUTE
32, SHEETROCK BACKING
A-UNDER STAIRS
B-ABOVE GARAGE
DOOR HANGERS
M MECHANICAL --
1, FURNACE SIZING
2, FURNACE LOCATION
3. FURNACE CLEARANCE
4, 'B' VENT SIZING
5. 'B' VENT CLEARANCE
6. 'B' VENT SUPPORT
7. COMBUSTION AIR
8. DUCT SIZING
9, DUCT CLEARANCE
10, DUCT SUPPORT
11, DUCT JOINTS
12, GAS PIPING TEST
13. GAS PIPING SIZING
14. GAS PIPING SUPPORT
15, OTHER
e
CORR O.K.
CORR O,K.
1, WOOD STOVE CLEARANCE
2. CHIMNEY CLEARANCE
3, HEARTH EXTENSION
4. CHIMNEY HEIGHT
FURNACE APPROVED BY:
HEAT PUMP APPROVED BY:
GAS PIPING APPROVED BY:~ /- 1- 9-~
WOOD STOVE APPROVED BY:
OTHER:
P PLUMBING CORR O,K,
1. UNDER TEST --
2. GATE VALVE --
3. WATER PIPE SIZING --
4. DRAIN PIPE SIZING --
5. VENT PIPE SIZING --
6. PROPER SUPPORT --
7. PROPER FITTINGS -- UNDERGROUND APPROVED BY:
8, VENTING --
9. CLEANOUTS -- ROUGH-IN APPROVED BY:
10. PROPER GRADE --
11, HOT WATER TANK P. R. VALVE --
12. OTHER --
3
WALLBOARD
CORR O.K.
COMMENTS:
1, LID OVER SIDES _ _
2, NAILING _ _
3. W/R AT TUB OR SHOWER _ _
4, 5/8 UNDER S1)\.IRS _ _
5. FURNACE ENCLOSURE __
6. FIRE SEPARATION GARAGE _ _
7. ATTIC ACCESS _ _
8. DROP CEILING & LIGHTING _ _
9. BACKING AS NOTED ON FRAMING_ _
WALLBOARD INSPECTION APPROVED
BY:
4 FINAL CORR O.K. CORR O.K.
1. HANDRAILS -- 9. OUTSIDE GARAGE --
2. GUARDRAILS -- 10. CLOTHES CHUTE --
A-HEIGHT -- 11. SEWER/HEALTH DEPT. --
B-INTERMEDIATE -- 12. COMMERCIAL BUILDING --
3. EXHAUST FANS -- A-MECHANICAL APPROVED --4-
A-KITCHEN VENTING -- B-PLUMBING APPROVED -~
B-BATHROOMS -- 13, SMOKE DETECTORS --
C-LAUNDRYROOMS -- 14. FIREPLACE HEARTH --
D-DRYER =?<" 15. SAFETY GLAZING/
4. TILE AT TUB OR SHOWER DOUBLE GLAZED --
5, DISHWASHER 16. INSULATION CERTIFICATE --
PROPERLY INSTALLED -- 17. FREE-STANDING
6. FIRE DOORS -- FIREPLACE APPROVED --
A-SELF-CLOSING -- 18. WINDOWS & DOORS CAULKED --
B-SWEEP OR THRESHOLD -- WEATHER-STRIPPED --
7. ATTIC ACCESS --
8. HOT WATER TANK _L FINAL INSPECTION APPROVED
BY:
NOTES:
PLANNING:
. BtJ I LD I NG
P~RMIT
APPLIC.TION.
,.J>
City of Bremerton, Washington
Phone: (206) 478-5281 ASSESSOR'S ACCOUNT NO.
I
PHONE ffii
7ErJ:!:T- TL-/Sge;= ~
PHONE 257/- 31/'1' 0
OWNER'S NAME
CONTRACTOR dr../~ STATE CONTRACTOR'S L1C, #
ADDRESS to bc>/<- ~~ ~[?~
ISSUANCE OF OCCUPANCY CERTIFICATE REQUIRED BEFORE OCCUPYING BUILDING
OWNER'S SIGNATURE
BY
Authorized Agent
~ RESIDENCE
o BUSINESS 0 OTHER 0 NEW 0 REPAIR ~EMODEL 0 ADDITION 0 DEMOLISH
o SIGNS
PLANNiNG/ZONING
# STORIES
OCCUPANCY
THIS PERMIT ISSUED FOR: :::;~~_ j)CL~1ta.PJ~ 4fCL-<.~
C"r,,-"-A f-H~ 16 ~. I;L -to -J'5
~
-
-c.~ '5 ~<.~
All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any other state or local law regulating construction or the performance of construction.
OWNER OR BUILDER SHALL CALL FOR ALL REQUIRED INSPECTIONS AND RECEIVE APPROVAL PRIOR TO CONTINUING WORK,
SEPARATE PERMITS ARE REQUIRED (WHERE APPLICABLE) FOR PLUMBING, MECHANICAL AND ELECTRICAL.
COMMENTS:
;::~~''i :.;
N~ M~cl4. p?~ h {.-.~
/t;/ ~ ~-t/ ~I /'L-'~-
..f.&u ~? s~~ ,fi~ .
5/~ ~' d p;p./ (~
BUILDING OFFICIAL:
w~ [OJ LrnnqID
DEe 0 6 1985
BREMERTON
BUILDING DEPARTMENT
hsz; f/A/~--
VALUATION
$ ;( _ DOO. 23
BUILDING INSPECTION DIVISION -
PLAN CHECK FEE
$ /3,"1-5
817 PACIFIC,
RECEIPT NO.
PERMIT FEE
$ /75.0D
RECEIPT NO.
DATE
Bremerton, WA 98310
BUILDING
P!RMIT
APPLI~TION
City of Bremerton, Washington
Phone: (206) 478-5281 ASSESSOR'S ACCOUNT NO.
ADDRESS (0
STATE CONTRACTOR'S L1C, #
98 .2;; ?7 t:,
PHONE ffi
TET.eT- TL- /59{!.F;
PHONE 87/- 311'1 0
ISSUANCE OF OCCUPANCY CERTIFICATE REQUIRED BEFORE OCCUPYING BUILDING
OWNER'S SIGNATURE
BY
Authorized Agent
~ RESIDENCE 0 BUSINESS 0 OTHER 0 NEW
PLANNING/ZONING
o REPAIR ~EMODEL 0 ADDITION 0 DEMOLISH
o SIGNS
# STORIES
OCCUPANCY
THIS PERMIT ISSUED FOR: =;~ f)CX--?n-(lj?if~ ~~
~,f1-{?.A~
kr-.
,.
~s~
All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any other state or local law regulating construction or the performance of construction,
OWNER OR BUILDER SHALL CALL FOR ALL REQUIRED INSPECTIONS AND RECEIVE APPROVAL PRIOR TO CONTINUING WORK,
SEPARATE PERMITS ARE REQUIRED (WHERE APPLICABLE) FOR PLUMBING, MECHANICAL AND ELECTRICAL.
COMMENTS:
>-
...
-
(,)
BUILDING OFFICIAL:
VAWATION
$ ~ Doa.9.E
BUILDING INSPECTION DIVISION -
PLAN CHECK FEE
$ /8/76
817 PACIFIC,
RECEIPT NO.
PERMIT FEE
RECEIPT NO.
DATE
Bremerton, WA 98310
I
BUILDING ~RMIT
-~
_u_ ~
City of Breroerton, Washington
Phone: (206) 478..5281 ASSI:S-SOR'S ACCOUNT NO. 3~g 'Js~ 000 -
SITE ADDRESS/LOCATION
1608 BURWELL
OWNER'S NAME GEORGE ,HUBERT
OWNER'SADDf{ESS SAME AS ABOVE
PHONE
II:
w
z
I:
o
CONTRACTOR TIMS CONSTRUCTION
ADDRESS PO BOX 113 SOUTHWDRTH
STATE CONTRACTOR'S L1C, If TJ!~IRITL 15 9 CF
.i'.'
98386PHONE 871-3114
. '. - - ,
ISSUANCE OF OCCUPANCY CE~tIFICATEREQUIRED BEFORE OCCUPYING BUILDING
OWNER'S SIGNATURE" BY~~--:Z""~ 6/
. ." .' /~;:;';~Agent
(SEE AND READ NOTICE ON REVERSE SIDE)
Q RESIDENCE D BUSINESS D OTHER D NEW aREPAIR D REMODEL D ADDITION 0 DEMOLISH
D SIGNS
PLANNING/ZONING
# STORIES
OCCUPANCY
THIS PERMIT ISSUED FOR:
APPROVED BY BUILDING/DAVIDK. DELPH. AS NOTED.
- , , !
REPAIR FIRE DAMAGE IN UPSTAIRS APARTMENt
.' .
All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The,granting of a permit does not
presume to give authority to violate or cancel the provisions. of any other state or local law regulating cc;mstruction or the performance o~ construction,
INSPECTIONS REQUIRED: Foundation D Framing D Plumbing D Electrical 0 Wallboard KJ ~ FINAL ex
OWNER OR BUILDER SHALL CALL FOR ALL REQUIRED INSPECTIONS AND RECEIVE APPROVAL PRIOR TO CONTINUING WORK.
SEPARATE PERMITS ARE REQUIRED (WHERE APPLICABLE) FOR PLUMBING, MECHANICAL AND ELECTRICAL.
COMMENTS:
>-
...
-
()
SURCHARGK;$L ')0
BUILDING OFFICIAL: . DA VrDK. DRT,PFf /1 e
$
VAWATION
26)000.00
PLAN CHECK FEE
$ 113.75
RECEIPT NO. . PERMIT FEE
74966$ 175.00
.RECEIPT NO.
.7 . -9t~
DATE
;'~-9---,rs
BUILDING INSPECTION DIVISION -
Bremerton, WA 98310
Permit, No.1
6981
COPIES TO: WHITE - BUilDING, YELLOW - ASSESSOR, PINK - OWNER
'jJx':W~~:w',';r't"'f':i~'I~~
~"' -\,':;':;j:;'Yl~' ~^ -'1f~:"":?:'f~:
'tI
.
.'
,~
N9
36832
.,5 ()....!d- .' '/.), 7 I
Fee $____________,__.____.________ _____________.;____-----------------------_ Receipt No, __________________________________________________________
BUILDING PERMIT
CITY OF BREMERTON BUILDIING DEPARTMENT
F. E. IRISH, Building Inspector . ESsex 3-1411, Ext. 36
Owner's Value I Bldg. Dept. Value I DESCRIPTION:
$ 500 I I Lot . Block Additions
Address on Job --I.k-q!.m~~__m_____m_mn_m____n____"______---mm-m- Date _m~mLm__m mmm196~
Building _____m___m__X __m___________ and m_m___m_nstories __m___--nn~______m basement. Lot __.____'-____ __ x ____n__m_____
Front Yard ______nm_m__m_n_ Rear Yard ______________:_mnm Side Yard _._._______mnmnm__ Garag ___ __m___m"_m____mm_
Occupancy - - - - - - - - - - - - - - - - 3-- - -- - - z- - -- - -~ - - -- - - - - - - ~.~ - -- -- - -- - - -.-: -- - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Zone - - - -- - - -- - - -- - - - - - - -- - - ---'- - - - --- ~- -- - - - --
Owner --.n-ll-~-?---.~~~~---------------- Address -_-______________________________________~-- Phone________________
Con tracto __ n___~~- ___ _m__ll'________ ______m m_ __m_ A d dress _ _ _ m n __ _ ___ n__ ___ ___m m _m _m_ __ m Phon en ____ m__n ___
This permit is issued for:
::::::: :::: :::::: ::::: ::::: ::::: :~:::: ::::: ::: :::::::: ::::::: :::= ::::": :::: ::: ::::-: ::::: -:::::: ::::: -:-: :::::::::::::::: :::": :::": ::::: ::::: :::
All work to conform to all applicable building ordinances and amendments. Please note the following
special instructions and requirements.' . ,
DETACH HER~ AND POST THIS SECTION ON JOB
INS,PECTlON - Reinforcing steel must be inspected after placing and before covering. FORMS shall be inspected
and approved before po'uring. All plumbing, wiring and the frame o,f all buildings mu'st be inspected and approved
before covering. Wood preservative to be used on all wood against masonry. Ventilate fo'undation and attic. Sepa-
rate permits required for plumbing, wiring and heating. See City Engineer befo,re working on streets or sidewalks.
- - -.. -. -. ~ - - ~_. - -. - - - - - ~ - ~..- -.. - -... - - ~ - - -... -. --. -.. - --. -;. --.. - - -.. -..- - ~. ~ .'--_.. -'-- ~,-- -- ..._;, '. -- ~ - _..;. ..'"~ - - -. - - .,. -. -. -.. - - - -. -. -.... - -. -,;,..- - - --..... - - -. - - - - -- - -. -. -.-. ~ --. - ~- - - --. - - -- --
, .
-.. - - - - - - - - - -. - --.. - - - -.,. - ~. - -,;, ~...-- - - ...;----.... -. ---... -- - - -- - -.. - - -..... -. - - - ~ --',. -'-- -'. - -~-..- ~... ,;,'----, -": -.. - .'"" -_'l',..,"":."'. - ....- -.. -. - -_- - _.. _. _ _ _ _ _ _.. _ _... _ _'_,_';'';'"_,,. __. _. .'_ ___. _ _ _.......,;, _ _... _ _ _. _ _._ _. ___"'_
... - - ~ - -. - -.. -- - - - - - .'-,.. - - - - - -- - - ..._. .-"'-- -'--. - - -- -;. --. - ',;.'-- --.. -.... -... -. - - -. -- - _.- - - ----,- -.. - - ---., -'-;~. .--,. -.. - - ..'''; -,". -'-,.-" -,. -. -.. -.. .,." - - - ~. -.. -. -- - -... - - -- - - -'- - -.... ~ --- - -..- - - -- - ~ -- - - - - - - -...-.. - ---
.' . -.' - ' " -. , - -',
. - ' - , . .
. - ~ - - -. -... - -- - -. ..--. -. ~ ..-- - - -..__... ;;',-:," - - -...... - - - - - - - -_. - ... -. .....,.--. __ - -.. - - - -,-.-.,;..~.. --~ -" ~ -,C" -'... "','" ~"-':"-l'" ~ ..-- ,;;.-.~ ,.....;;, ~ ..'-..- -... _-.. __ _.. _.. _ _. _ _ __.... _,__ _...... _ _..... _ _....... ~ _ ~... _ _ _.. _ _ _ "_.. _ _ _ _.. _~. _.. _ _ __ _ __
" "
- -.....- -'.. .,...:............. -. - -. -.... _:.- -:- .,- ~,.. ..'-,- -:.. -....... ~.. --. -..... ~.. - - - - -.. -..... -..-.. .l""'; .'- ."... - ~ ;;....-.'- ......,~-,;, ...,'..-.. ~.. ---.- - ....,... -.. - .__ - .,-,- -.. -__..... _ _. ..,~ _ ":" _ _ _.... _ .,_. __. _ _. _ _.... _. _ _ _ _,"'_ _.,. _ ~_ _ _... _ _ _.. _.. ~. _........__
.. ...... -. -... -,- -.. -. -.;-_.. - ~.. -.... -. - -,~ - -.." -... -. -,- -..... '..,..... -. -'..';'.... -. - --,,_.......... - --',.. - -,- ---....., - - .,'" .,"",,- -,~.,. - - -.. -'.,.-.,. ;';,-. - - -..--.... - - -.. -:.... -.. -. - -... -'--- ~ -........- - _. - - -..... -... - -.,.... -... - ~ - -- -. -- - -'- - -.;. -- - - ~. -...
.. -..... ~ - -. -,.,._..';'.. ~ -'. ---.... --.. -.- ---'. -........ ~ -,... - -.. .,... ": -- ~. ..o._... _....... .-_....... _,_ "._. __. _-. ...-,.. _,:,," .'_ - .-.:.. _,;,~,__.. '" _..;... _'_'", ~,..;: __....;,......... ..,. _,_ _. - - ",_"... - "-,_'_ _,;;. ..,.,~ - - ",___ __ _.. _,...._. - - _. _.. - ~ _. _. - _..._. _._ - - _... - _.. _..
, ,
-...... - ~.,. -. - -..-.... - -'. -,-. - - --''''- - ..-- ';',.,.,. -... -- .-.. - ..-..... ~'-.-.. -.. -'.... -..-" -.. .'-_. ..'''-'"" -".~. ~"--.-. --.... - -,.;, -~,.;.~ ~-.. ,;,'.;. c;;<-R..,,~.. ;'--;",,,.-;,. ._.-_,;. -. - -.. ""'- - -;. .'-. - - "'.. -',- -.. - _. -l'" _ _ _. ~ _. _......:.. __.. _ _... _.. _... _,. __ _-,.__ _ _ _ _~.... _..... __
. .
. .' ,
, ..
' . .
. - - -. -.. ~-... -. -. - - ",..,-'"';.~..,.....,.... -.:;.. -.....:. - ..-..;' .,.'.'_ __ "'_.. - - __,,,, - - _.,. ."_ - _..,.,_ __;;. ~ __.,.,.,;":;.0"; ..".,..,;,.,-.,..,.". _. _.'- ';".',:. _,. _. ';'-~:_'., _._,,,,,",,..,~.-....,., ~.-_ .._... _ _ .._.. _ _ _;. _ _ __.._ .._. _ _ _.. .';;' ~. _ .,_..-....... _.,.. \"_,;, _.."' _. _.. _ _ _. _......,.': _...'.... ...,.,....:.. _.... _._
, ,
. ,
.. ~ ~.,.. - ,- .....-....' ~.. .....,.n__.-_. .'._..-... -. -_.,.'.. -.. "'- ..~..,-'~ ~- - - --"'-'",~''' - "'-'"...;. ~.. ~.~ ~,. '_"_:~_"':_:"'_";"'_ _,_. ~".;;,.,.,... ~-."-:i"I'.." .. ;0'--:-':',:- -.~';."..:,..'.,.~. ~-".. ~ -,. ---. - -. ~.. _'.., ""l"':- -...,. ..'- -i- _ ~ _ _ __,;, __. ~.. _-~ _ _...... _:-.;. _ _ _ __ _ _. _ _',.,..~...... _ __ _ _ _ _ _ _.. _ _,'" __ _.....
.,. ~ '" ~ ~.. - "-:",.- -';., ~'.. ,~:..-- .,-..". ...,-:--.. -,-. -. -,. -.,- ~ - ..,:,:,,;-".'..~ ~-."..---~;,,~ --- ~":. - ""l"'-"-": ';;:'_ :'!__.,. "-_-",..,_,,"_'i;;-.,. ~ - "".- '-...'..,. ~,_,.. -:.,:-.. ";'-~ "'~'.;,"--.,.:~ ..f.. "'.;':":~_.,. .'_ __ -""i' _ _ "!.. ._""'_._.. _ _ _........... __,,,'_'. _.. _ _. ...'_...... _ _...,. _.. _:- _ __.,. _ __ _ _.._ _ _. _... __... ___
" <,'", "."
",oo - - .--..,,.. -.. .,-" "~.."!'....;.. .,,;';-"'.. ,__;;'. ..,._..__,..-.. ";..,._ .:...."_ _'_ .........,._. _.. ",,_ ...._:~ ;;,,__. ....'_,.. .;'. _'_ -:".... "'.'o;'';;,':,! ".oo ..."'-.... ".:'!--.i"I",-J,. ~'.. "" -OJ.''.,. ~_;;. ~ -'-_..:, l"'__,,;,.;.,".;;..,.''''-...,....... - - --.. -___.::.......' -:_. _._,_ - - "; _.. _, _... _'_ __. _. _. _.. _. __'_ _..... _ _ __ .'''_ _,__ _ 't'.i,,_ _ ':"_ _ _ __ _ _ ~
" ' ,
", ,
. " .' ,
. , , ,. ,
.... - --,.'... ---.. -'~ .-""'''l'-'''';';';;' "'!!'.,. - -,-',","',- -_,..,..-.-__~ ~ -.. "":~"__":_ ._;..;; ~,';.:,,,_,,,,,,,~,, _ __- _" __ ;._,_ ';;'_ _,,, _-_ ",.... ,...~":, _.;;.. .:;',.~._... '"-~;:I~.,;,;..:~"",......__.c_,_-...-;.. .';o,...r.'..__.. ,.-_:_,~ _ _ _ ,..'_'__:.,_.,._ ':' _ _.. _,...., _,.,.... ," _ _. ~ ____ _ .-.-- ... ___., _'.. _. __..;,., ...._. _ __.. _..... ~.._.;o._
, ' . ,'. . . '! . .
., , . . - , " '. .
. .,.-,... - '--;'-.. .',. -.".. --.<;; .,.;.'....~''''',~'_.. - - ---.-i'-,-'.-" -?',;, -co;-.. -;.. "-"i-,~ ---- -_'".''' --1" - ~ .,...-.''l''':-... - -:~,.,_.. _"!. _.. ..,0,._.. _...,,;;,_,_:.....,..._.. "'.;.,,;; ,,"':.. .,-:<;;,- :;._:o~ - - ........"' -...,... _ _. _ ___. .......... _ __... _. _...._ _.. _ _,'" _-._,;. .,_~ _,.. '"'_ _ _ _ _ ..';., __... _'_ .-~ .-. _..._ _._ _. w
. . .
.. .'~""" ~.-,. ~ ""',w'__ .,,~J;.'," --..-.;. .'-~.,. .........- .;.'~'""", _..-~,._ .;,'" ~-.:..'& .,....,"'.... .,........ _,_:~ _,...~..,.... .._-_ ~'" ~ ;",",'''-.",. _-..,..-..,.;.,._ _.. ..,..,,," _ __,... ..,",'" ;;,,_-r,. .i-,..~;.. ",,:'" ~ -'i- _.. _. ~ _ _...... _ _.... ~._. _. _.. _.. _ .,_.._..... _ _...... __ __.,.___,_..... _..... _. ,;,__.. _..._,~,.,.'.. ~_ __,.. _... __
. . ,
- - ..,~.oo "'",'''.''' ~'.; -.... ~'._'''__',;;;'.''. -,..,,;;;,- ,",~-.-';;,.",~., -'.:~-ol"'~_~ ~,":,.,..,. ~'... ;.'''~ .'- - -.............. -: - - .-.;. - ,-" "',...,.......;.,'--_..;. - ..'...."'l':,~:..,,._,.. ~-:;,...'-"-;..,-'--'--I:'~;.:- -;. -. --. ",~ ..'-.... -'7' -.... .,- - ~ -.... -, -. - .~,.... .,-.,.. - --. - - ....,. -.;;..... .'..,,; -.- - -. -...,.. ..'~ - -7'" ~ __. __
~. ~,..,..: "',~ ~ ~,. ~'-,..;. - eo ...'~,""- ,;,',. ~->':'".".. ....... -.l",;.'....,--~'-;-,..,!"., -/,.,. -'';',~ -"-:, .,-:..'~_., - - ~ -..... -.'...-..".;.-,i.;. -,":'~'-;" -:.. - -'. f .;_~ ...-..--...~ --;;.;".':'.:'j,,:~'+:-'''''''''' ..'.;,-__ - - _.... _.. _ _ ~,_ _ _....: .;;:... _,. .,.~.._. _ _,~ ..). ,.-0; _.. _ _ ~ ~. .'_-_. __ _ ,,"''''_';; _. _ _,. :__~~,,.... _..,... _ _ _ _......
- -..... - -... - - -,- -... -"" .-.... -'l""-'.;. - -"!' -,. ~:~ -.... -l";.....;,.~;...-.,. ..',,: - -,.,.. - -.;. -.., ,:,-,.. -:-::-. ": '-,f - :l.:_ ),;-...'",,- -_.. -- .--. -... .-....;",,,''''':-;..,,.,,.,''''... .J"'~''''_'_;~ "," -"-,,..:- -.. - "-,'-"0.:'---... ~ -'-"..~ -.. j)""''':~'' _ ~,"'7,.,...... _..,. _. __ _,. _ _ _ _ _. _ _ __ _ ..-..,._.._ _ ~.... _ _ ~_ _.....
, ,
, '. '.' -. ~ .'. "
-. -. -- -. "".-..."'1"... ",;;'-'". '!o -,,,,-,-,.-';' -- - -,,;;,,,"'.. -......:',;;,..-.,..,...,. ...."',..,.... _ .'._'. _ _'_-___,.......-.':~""-,..;,,--,..;;-. -........ ~'_-_" ___ _,.'" _.;, _......,:'__'~'_ ""..",-_,,';: """".'"','::'.... ,;.,'....:...... _.;.,. _ _,;, ~. _ _. _-..,.,_....-__.. _. ...:_'_-":, ~:_. "'__ _ ..,.:: _-..:'.;. _ ":. ~ ~,,,.,, _ _. _ _ _......;..... _......,;~.. _'_ _ _ _ __. ___
'~~F
.. '. .. '. ,. _A
-... - -... - '" -..- - -_;.,~ -_'" .''':.... ..-.,." ~ ~. - .-;..:..',;;, ....,,. -- -,.;. -'-.","- :;- --.. ,O:.l"'':;'' . ~ ~-~-- ... -,,:, ":'--;". - - ,_.~" ~ oo-~ .'., '" ..,-~ ~,~.., .:~ - ~~,:_.. ~ ~-,..:~,:-.-- ".,,.,.."'" ":'~;. ~'.." ~ - - ~_ -,- ,.'- -'." -77'-'-'~ ":'~," "-'''''' - - - - - - _. _.,. - - - - ~ - - _ __.... ~ _ _ n _.. - - ..__ - _ _ ~ - ~. _".OO
Owner's Signature ___nn__________n__n_nn_".____:___n________:~-_n_'.- By &~;d-~;;.;nn------------------- n
BUildmg Inspector __ ___ __ __P""_' _:_ n_~~-:-um_ ~._mn m _mm_ um _ __ ____ _ _ _m_
, ,~Y'u -"~ ~.-~._.._:_.- _ _ "oo --.~ --.-, _ _ _ _-- -__ ~ _ __ __~ _ _ _ _ __ _ _ __ _ _ _ _ _ _ _ __ _ n__ __ __.