HomeMy WebLinkAboutBURWELL ST., 1026 1/2BUILDING PERMIT
INSPECTION
V'� LL CARD
SITE ADDRESS
Ya, � �IAJP.ciSf
PRO EC
d em o�I i' i at 0�-
3g$ sa Fr R6,5
Building Plumbing ❑ Mechanical ❑ Fire AlarnVSprinkler ❑
DURING INSPECTIONS THE BUILDING PERMIT & APPROVED PLANS SHALL BE ON SITE
Permit # B B 0 5 —
For Inspections Call (360) 473- 5870 - Approved Date Notes
�i
1 f �O UN DA T ION
F)O NOT POl)R ('C)N(`iWIT,
Erosion Control In Place
Foundation Footing
Foundation walls
Plumbing Ground Work
In Slab Mechanical
Footing Insulation
-
F-1
2nd PLUMBING
,Il is CHA NIC, -1 L
6AS 11'111
Rough In
Duct / Vent
Support / Test / Meter set
rd FRAMINGShear
3
Z„�a are approved
Hold down connections
Panel nailing
L&I Electrical Approved
Ventilation requirements
Framing
t h
I NS UTA TION
Under floor
walls
ceilin
5th SHEETROCK
V”
6 th
F'INAf
All of the above
Must be
approved
to final
UILDING 473-5870
C-
RICAL Dept. of Labor ust 5-4
Grease Trap,
P98L<ach 473-5270
Se on 3-5270
E
ALL
ALL FINAL INSPECTIONS COMPLETED 47 _
Occupancy Approval (Single Family Residence Only)
DO NOT OCCUPY BUILDING WITHOUT BUILDING DEPARTMENT APPROVAL
PROTECT THIS CARD FROM THE WEATHER
1A
INSPECTION RECORD CARD
CITY OF BREMERTON BUILDING DEPARTMENT 11617
PERMIT NUMBER
ADDRESS
OWNER W4 ffLim PHONE 532-5349
CONTRACTOR self PHONE
FOUNDATION
1. PERMIT ON SITE
2. CHECK PLANS TO PERMIT
3. CHECK SETBACKS
4. PROPERTY STAKES
5. FOOTING WIDTH & DEPTH
6. SOIL BEARING O.K.
FOUNDATION INSPECTION
APPROVED BY:
2A FRAMING
7. CHECK FOR FILL
8. REQUIRED STEEL IN PLACE
9. CHECK FIREPLACE FOOTING
10. ANCOR BOLTS
11. FOUNDATION VENTS
12. CRAWL ACCESS
COMMENTS:
1.WIRING APPROVED
2.FOUNDATION VENTS
3. SHIELD UNDER POSTS
4. POSITIVE CONNECTIONS
5. SOIL TO WOOD CLEARANCE
6. BEAM SUPPORT
7. TR. MAT. NEXT TO CONC.
B. WASHERS ON ANCHOR BOLTS
9. BEAMS PROPER SIZE
10. FLOOR JOIST SPAN
11. NOTCHING & DRILLING
12. STAIRS
WIDTH
RISE & RUN
WINDERS
LANDINGS
HEADROOM
13. ATTIC VENTILATION (upper & lower)
14. CHIMNEY STRAPS SECURED
15. FIREPLACE COMBUSTION AIR
16. FANS VENTED TO OUTSIDE
17. WATER CLOSET CLEARANCE
18. SMOKE DETECTOR
20. FIREBLOCKING
STAIRS
DROP CEILINGS
TUBS OR SHOWERS
ROOF & CEILING LINES
FURRED OUT AREAS
FIREPLACE AT CEILINGS
HOLES PLUGGED TOP & BOTTOM
LID IN VOIDS
21. WINDOWS
MEETS ENERGY CODE CLASS
SAFETY GLAZING
REQUIRED FIRE EXITS
WINDOW SILL HEIGHT
22. CEILING HEIGHTS
23. SWAY BRACING
24. TRUSSES
PROPERLY INSTALLED
STAMPED
PROPERLY BRACED
25. ATTIC ACCESS
26. RAFTER & JOIST SPAN
27. ROOFING, FLASHING, SHEATHING
28. SIDING
19. SHEETROCK BACKING COMMENTS:
UNDER STAIRS
ABOVE GARAGE DOOR HANGERS.
FRAMING INSPECTION
APPROVED BY:
2B, INSULATION
1. PROPER R -VALUE
2. VAPOR BARRIER
3. PROPER FASTENING
INSULATION INSPECTION
APPROVED BY:
COMMENTS:
MECHANICAL
1. PERMIT ISSUED
2. FURNACE LOCATION
3. FURNACE CLEARANCE
4. 'B' VENT SIZING
5. 'B' VENT CLEARANCE
6. 'B' VENT SUPPORT
7. COMBUSTION AIR
B. DUCT SIZING
9. DUCT SUPPORT & JOINTS
10. GAS PIPING TEST
11. GAS PIPE SIZING
12. GAS PIPE SUPPORT
COMMENTS:
PLUMBING -
1. PERMIT ISSUED
2. UNDER TEST
3. WATER PIPE SIZING
4. DWV SIZING
5. PROPER SUPPORT
COMMENTS:
UNDERGROUND APPROVED
BY:
3 WALLBOARD
1. LID OVER SIDES
2. NAILING
3. W/R AT TUB OR SHOWER
4.5/8 UNDER STAIRS
5. FURNACE ENCLOSURE
COMMENTS:
WALLBOARD APPROVED BY:
4 FINAL
1. HANDRAILS
2. GUARDRAILS
HEIGHT
INTERMEDIATE
3. EXHAUST FANS
4. WATERPROOFING IN SHOWERS
5. DISHWASHER AIRGAP
6. FIRE DOORS
LABLED AS REQUIRED
SELF CLOSING
7. FIRE DAMPERS INSTALLED
B. PENETRATIONS IN FIRE WALLS
FIVAC APPROVED BY:
GAS PIPING APPROVED BY:
001A
1. WOOD STOVE CLEARANCE
2. CHIMNEY CLEARANCE
3. HEARTH EXTENSION
4. CHIMNEY HEIGHT
p, FiN i KAT, j* ej i reiv w"IF. 0111111111111111 0
6. PROPER FITTINGS
7. REQUIRED CLEANOUTS
B. PROPER GRADE
9. HWT PRES. RELIEF VALVE & LINE
10. SEISMIC STRAP
ROUGH -IN APPROVED
BY:
6. FIRE SEPARATION IN GARAGE
7. ATTIC ACCESS
B. DRAFT STOP IN ATTIC
9. PROPER CONST. OF FIRE WALLS
10. DROP CEILING & LIGHTING
9. HOT WATER TANK PRL
10. OUTSIDE GRADE
11. SOIL TO SIDING CLEARANCE
12. SMOKE DETECTORS
13. FIREPLACE HEARTH
14. SAFETY GLAZING
15. INSULATION
WINDOWS MEET ENERGY CODE
UNDERFLOOR & ATTICE INSUL.
WATER PIPE & HEAT DUCTS
16. WOODSTOVE APPROVED
17. WINDOWS & DOORS CAULKED
FINAL PLMB. APPR, (comm.) COMMENTS:
FINAL MECH. APPR, (comm.)
FINAL BUILDING APPR.