BREMERTON PERMIT CENTER
286 4t.h S"treet_ Bremerton", WA 98337
Phone: (360) 478-5275 FAX: (360) 478-5278
BUILDING PERMIT
JO~ Addr: 1407 BRADLEY SY Permit No: 00-0095
Loc2ition: Status: ISSUED
Pari:-::elNo :. Applied: 03/08/2000
~ed: 03/08/2000
Appljt;ant{SEARS HOME IMPROVEJ1EiHS 1-800~B79-1623 Expires: 09/04/2000
.12664 INTERUR8AN AVE S SEATTLE WA 98168 € X .VLQ d
D!~V ,RICHARD 8 .. If, .
1407 BF~ADLEV ST BREMERTON WA 99310 lA.) 0 (/V'S ~-e ch ..6V)
.. ........ .. CY~
HOrlEIMPROVErfENTS 1-800~879-'lLic :If: SEARSHIOllUi Exp: 10-01-00
. ... .. ... .... INTliSRURHANAVE. 5 SEMTLE WA98168 $;1..- .')01. _ ^. I.
Subcontn \) CT' u
Or,sc = NEW VINYL SIOINCSON RESJOENCE
* )!(*;~ *** )\(:1:)1(**** )I[:\(* ****'* ***)f:*)!:lIO!O!( ** **;<< **** iKl!:)I::)\( *X< ){(;'I< *)\()I()\( **)\( * **)/()\(:I()I( >>: ***;I::)I()1()j( *)j(){(){( * **)j( * ** *::I(){\:>I< * )!I.JI(*:J()l()!I. *
Valuation ::r, Permit Fees: 321.25 Total Calculated Fee~ 325.75
19,1308;24 * Plan. Check Fe~s: .00 ?)dditional Fees: .00
)I( Other Feea: 4.5p Total Permit Fee: 325.75
*~:* **l!i; ***** **)1( ** **)1( *,j( *::jol<:~( ** >>:)\( * *)1:: ** ** ** *** ****::i;*)\( * :I<:*.){O;:4< * ~(** * ****:l<JI( *:1<::>1<::;: ** * *)(< * >>::<< *' *)1( **)\()/(::+: % **)j( **)/( **
p~'r:mit shall.becclrne l'lbl1/alld void if the buildil'lli) o'r\.\lO'rk authoYind by thispeymit is not CO!~nced within
180 daysi'YOlll th~ dat~ of ""Ilchpenlli t, or if this l:JlIUdirWJ ort.Joy'k authoYizedby such perfnit, is Z'"u$fJI.<11'1ded oy
&b",ndtitl1f.'c,l kt illr~$' Hille ... after-the ("lOrk iSCOlllflllifI1Cedfo\' a pedod of 180 days.
NClHCE ~ It is the responsibility of thepel'mit holder, not the City of BrEm",erton or BUilding Official to see
itthdt1"equiYed imilpection':,f are made. The p.mnit hblde'( must. notify the 8uiloi1'19 Official when read>' 'for
iil$f.>i&cHons. Failure of tn!!;'peymi t holc.M>I' 1~o notify the Building Official of required irli3pections m,;wresult
in the .$(:q::.t:tage of!:.ne work unti1 such time thaI:. thlJ! pennit hold.w can substantiate to the building offiCial
t.hat the ctrnCealed lP!oYkmwet$ Oy ~1xG(;t>ds cOdeyequiniHl'lents. Any d~liti('m; t'l?stinSI, 01' fi.nanciilll burden shall
blJ.>.borne dHectly by th,,' p~n'mit holder'.. Fai.hll'e to $ubstatrtiat(.} code Yequir'ement.$ will imemnifythe City
;;against t'l,ny and all r'f.l9Poi1$ibility or liabilit>' connected with the comitn.\ction..
! rlei"\li!:Jycertffy that I h~;ve read ;r1'r1dexOl.irJined this p~mYd. t and know Hw salOO to be tyue and. correct.. All
prov1sionsbf l<1!.wS ,,",11e1 c.rdinances goveming t:h:ls t:vpeof I'JoYk win b0 complied \.Jith ltJhetheY spec~ified heyein
Oy riot. . The .8wantirl9 (:rr .<llpennit does not presume to 9iv(~ authority '1:.0 \liol<:1.te or cancel the pl'ovisions of
s'nybtheY$tate or 10(':&1 law yegu1a:tir19 constnJ.ction oy the performance of construction.
\~. ~/
., ", ../...~~,.... -', .--?
~;.(:;nat n"., . ,,"-,/ ~'- .' ..- . . a ~ :).. . .
".9 _ U ,"_" _~'~~.T;", .~.~. <9-~ .~..._...e"'__... Cate..________~_~___...__~
.--~~. .
I(~eytif'1tha't ;(~rtlexemPtfroll1 the n?quir~meY1t$ of t:he $tate contn'l.ctoy'S y<&gishation law. llnde~'
$ectibr\::3, Chapt,.d126, hl.l^,$ of
Da,te:__._._~._._,_~...__~____...
;;**lK******,U;i(**>IOIO(<ij(;j(****)f(X<Jl::lK//.....y . ~...~ ....
.Permlt CeJ1ter-"'APprov~d B)I:/1t1J____..,_..~~~".._ D.3.te= __."i::.__~~Q..._~ .9 u
,~,.)
r ,~ " ~ ~'- ,,"' __ ll"",' h,",,:," ,_, -' ,",<N ~, 0..'- ., ~", :"-~ .- , . '.'i" ,,'1""1, .~';~,~'~.~'! J;"~,~\!_~';.ll'-f,' <'{:!"h'-~\'o,>l.,.'~':, ,:,-,<;1". <}"~:,, "" . ~. -~,. ..,.? ". ,-,~".- , -," ~ ~-'~l
I '~'F'
I
I ,
BREMERTON. PERMIT CENTER I
I I
I 286 4thStteet,. Bremerton~WA 98337 I
I
Ph"ne:: (3(0) 478-'5.?Z~ FAX:, (360) 478~5278 I
Building Permit No~ 00--0095
I... Job Addrese;: 1407 BRADLEY ST Status: ISSUED
Locatio n ~ Issued: 03/08/2000 .
i Assr ACbtNo: . E~,xl"Ti,.-es:"09/ 0 4 / 2 0 00
R EQ U IRE D INS PEe T ION 5 -,-", --..- ~
Item: .02700 FINAL-k'."8LDG DE~pt: BLDG € ~'0W27f
**************************"**************:***********:**:**~f~*~~~*T\~*
~~;~;~~Hti~ "Nu~e~e ::(~?~I~Ltz:edb~ th~~a:h:ngt.o,n {.193s0clatlon o.f 8Ul dl .. ~lals
:::;, _dlHSP~ !"lu~,t berb~;>L>teredt"'Hth t.h". 5tate ofWA ...... ....
Sf OFtH1: sta:te of WA Dept. of Labor and Industries 478-4921 '8- d 'i-6)",
HEr'~L-'TH : Brernerton/Kitsap Health Oisty ict 478~'5235
INSPECTIONS PERF:ORMED BY THE, CITY OF BREMERTON ~1UST BE SCHEDULED THROUGH THE
PE.RMITCENTER" (360) 478,.-5275. .
I ' *************- *)j<: **** ** '* * **** *** **~(********* ****** ** ********** *** **** *** *** ******
"
Date:
!
I
I
~\ I
I
.1
I
1
I
I I
I
I I
I
1
!
,_04'
L ." C;;l"~) . -
r-*.~=-~~---- -::~,'.=:~~=,..~u~==~------l
, ,',,' ..' .. '''., " . '" ~1~~:(;i~ip:r. I
***)j('**,*'*,*****,>,<:**:* I
" ;7 IS f~fnOtl
.11 " I
. Cl)SH tlon;
I ''''~' ,..., ,-#,. ;,_",. "'.'. ,....." ~,..' ,~,,,,,. .."', -.:,...~ "W "~..'~ -..~, y",~, 'lW '.'0'" '..,,,, ""'"'f''''''' ~,,~ ~~'__~_r_4_".~_____._w~~_'~__,__,__~___ I
p (~ r lTi ,\: t:, r )lp{~ : y E!:LJ)G PEh~M!T
~:) ,1 'I:; !~j ::,;T I
1 ()tZ;I. , 7(~, I
It:ll;$ nt :3 :~: ,~S ,. :;1 f5 'ro I:::,LI.. .\: " '7t7)
Ba nc'e~ ,,0<) I
***y,:*"o/c * :,>j;:** ,** * ** :il'* **:'f; ** *****;:101<;****:* * ****** ******** * *: ;'jO!:: ** :t<******,**
f,'CC01J nt 1~\m()Unt
.,:toOl (2;~1;l) 1 .:2~;
l:~ ( :> STl'\ 4,fSO I
"'~ .,:.'.. "'''' ~',,,", ',"."~ "A'YO ....,,_ ""... ~'''~ """, ,_, "".... .,.,,;.. '-"',' ',""" _,"-' .~.~; """" ~.._ '''i''' ".", ,.,,,, ".",. .,,,.0'.......
,I
..
,
..;.1
I
I ,.... I
I J
I .'1
t
I
I
I I
I J
t.. .M'
,
~ ,,~~w~ '_,l ,;t.A,:~t~"''''~'_'''"'''---oio.'''-......-.....1_'~~I''~''~,"_,~_"~_,--,,
j:::::: . Builliog.uDe:r:mil. ~Imli@a~mi. . ..,. ...... ..:.
........... ...................
..-...'..-.......... ;.'...:-................-.............. . ... . . .
. :'~:'....... ':::::';:::::::;::::::::::::::::::::::" '. . . ':. ......... ,. .
.-.-............... :-:................-.................. . ....
........... ....;...:...................-......... . . . .. ... " .
:::...:~i~:~~;'Il~~~p~~.N.g$~7:lmQije:r(~~Q)478f577$;:;p~~:(a@):~7$f$Zl$:.;:::':':'I;:':'
APPLICANT: DOWNER .IiJCONTRACTOR DOTHER
Site Address: I t..J 1J ~ A,.aJ./~9 ~f- Tax Account Number:
Check the ~e of application applied for below: ~ E~ IE n WI IE~'
o SFR 0 DUPLEX 0 MULTI-FAMILrO . . = ';.
. . . . . . ~..
o MOBILE 0 ACCESSORY BLDG 0 RES ADDN: . '" ....,:;,
~S REM 0 C01llvf ADDN 0 C01llvf REM . . MAR 08 LUUu
o REPAIR 0 SIGN 0 DEMOLITION BREMERTON
o NEW C01llvf. 0 TENANT IMPROVE:MENT BUILO\NG OEPARTMENT
o GRADING (cubic yards: ) 0 OTHER:
Nature of Work Proposed: ~f(J'~ U~'^\\ ~~ '
S\ L~
Square Footage: Dwelling Garage: Decks \q~q 5~,
..;..:.;...:.....'V'~l:qj;aijii .::::j;...p~::liti~~~~~.;.::.....2~tlii.F~~: .:. .:::::'$qf&i~;g~:j;...W:..:.j;.gNiJ~.~~~$..:..:::
} q ~O~ ~'2t-\ Energy: $50.00
, State: $ 4.50
Applications for which no permit is issued within 180 days following the date of application shall expire by
limitation, and plans and other data submitted for review may thereafter be returned to the applicant or
destroyed by the building official. The building official may extend the time for action by the applicant for a
period not exceeding 180 days on request by the application showing that circumstances beyond the control
of the applicant have prevented action from being taken. No application shall be extended more than once.
In order to renew action on an application after expiration, the applicant shall resubmit plans and pay a new
plan review fee.
APPLICANT'S SIGNATURE:~:Z-- ~___ DATE: 3/ {?/OO
I
BREMERTON BUILDING DEPARTMENT
Inspection Report
Permit Number: DO - 0 075
Phone:
Phone: r~Th~ €ICf~ I ({) d 3
FOUNDATION
Inspection card/approved plans on site Setbacks
-~ ----. Walls: required steel placement
Footings: required steel placement
--- Walls: required size
Footings: required width & depth
.-- -----.-- Special inspector (when applicable)
Bearing soil (soils analysis if applicable)
.
COMMENTS:
FOOTINGS APPROVED: _WALLS APPROVED:
FRAMING
Electrical approved I , Plumbing & mechanical approved
Crawl space access (min. 18 X 24) Floor joists and beams/proper clearance to earth
-.
Positive connections posts & beams Foundation vents
--
Posts properly supported Anchor bolts: nuts & washers in place
-- ~._-
Mudsill: treated material Floor joists: size & span
.-'
Beams/girders: size & span Notching & drilling joists & beams, studs
.._-
Smoke detectors: all required locations Exhaust fans: where required
-----
Exhaust fans insulated: unconditioned space Whole house fan, outside air intakes each bedroom
Fans terminating directly outisde Range hood
Dryer exhaust vent All vent terminations: windows & property line
-- -----.-- -~-
Fireplace combustion air Windows: meets egress requirements
Windows: proper U valve Windows: safety glazed where required
--
Ceiling heights Stairs: headroom clearance
-- --
Stairs: rise & run; proper width Fireblocking: wall to ceiling, furred walls every 10'
----
Fire blocking; stairs, soffits, lowered ceilings Fire blocking: tubs/showers
---- Fire blocking: stuff holes top & bottom plates _.
Fire blocking: lids in void spaces, shafts
-_.. ---~
Sheetrock backing Wall bracing
Rafters size/notching --"---
Trusses: specs, bracing
Attic access ---
Attic ventilation
--
Wail & roof sheathing Shear nailing
-- ---
Building dried in
COMMENTS:
APPROVED: -
ENERGY CODE COMPLIANCE
Insulation: proper R value ---- Insulation: proper fastening
Insulation: vapor barrier ~---_.- Bottom plates caulked to floors
Penetrations caulked as required .-'--- Electrical boxes gasketed or caulked
6 mil black poly in crawl space ~--
COMMENTS:
UNDER FLOOR/FOUNDA TION INSULATION APPROVED: --
WALL INSULATION APPROVED: CEILING INSULATION APPROVED:
MECHANICAL
.
Appliance location and access, proper support Appliance clearance to combustibles
-- Venting: size & support
Venling clearance to combustibles
-- Combustion air
Venllerminalion
---- Gas pipe under test
Duels: size & support
Gas pipe size & support Gas pipe: underground min. 12" below grade
Gas pipe within 6" or underground-coated Gas shutoff within 3' of appliance
--- --.---.- --
Gas logs: safely shut-off Gas logs: damper permanently open
----- ._--- . --
Woodstoves EPA certified Woodstoves & fireplaces: Tight-fitting doors
Woodsloves & fireplaces: proper health Manufacturer's specs on site
-- -
Chimney liner: when required Chimney: separate flues when required
COMMENTS:
GAS PIPING APPROVED: FURNACE APPROVED:
OTHER APPLIANCES APPROVED:
PLUMBING
I DWV & water piping under test DWV: proper grade
DWV: proper sizing DWV: proper drainage fillings where required
DWV & water piping proper support DWV: required c1eanouts -
----
Vent termination All fixtures vented properly
Water supply: proper sizing Shut-off valves on all fixtures
--
Water heater gate valve on cold water supply Vacuum breakers: where required
---- .--
Waler healer relief valve drain to outside Water heater: siesmic strap
R-10 pad under water heater when required Water-piping insulated as required
Grease traps/interceptors: where required Proper indirect wastes: where required
COMMENTS:
PLUMBING GROUNDWORK APPROVED: PLUMBING ROUGH-IN APPROVED
SHEETROCK
Proper fastening: nails-?" o.c. horiz. plane nails 8" oc. vertical plane
Proper fastening: screws-12" o.c. horiz. plane (1/2") sClews-12" o.c. horiz. plane (1/2") 24" o.c. framing
Proper fastening screws-16" o.c. vert plane (1/2") screws-12" o.c. vert plane (1/2") - 24" o.c. framing
---
Proper fastening screws-12" oc. horiz. plane (5/8") screws-12" o.c. horiz. plane (5/8") - 24" o.c. framing
Proper fastening: screvvs- 16" o.c. vert plane (5/8") -
screws-12" oc. vert. plane (5/8") - 24" o.c. framing
Area & occupancy separation walls Draftslops where required
Usable space under stairs (5/8" required) Waterboard where required (not on ceiling)
I Corridors
I COMMENTS:
I
SHEETROCK APPROVED:
FINAL
. , Energy code requirements met, exhaust fans I I Plumbing & mechanical .
Garage/dwelling door self closing solid core Smoke detectors where required
Handrails & guardrails, as required Fire ratings maintained
Exit signs when required Emergency lighting when required
Occupant load posted when applicable Building weathertight
Wood siding 10 earlh separation (6" Building Address posted
Radon monilor when required I
I .
COMMENTS:
FINAL APPROVED: