HomeMy WebLinkAboutBRADLEY ST., 1320 } FI BUILDING PERMIT 1320 BRADLEY ST Y V4 { INSPECTION ADULT FAMLY HOME (INCLUDES NEW WINDOW IN CARD BEDRM #1 & CREATE BEDRM #2) i i F s Building [] Plumbing ❑ Mechanical ® Alarm /Sprinkler This Placard must be posted on or near building and the Permit & "Approved" plans must be at the sit Permit # BB11 00309 POST ON SITE Call the following Agency Telephone Numbers for inspectio - Propertylines shall be properly identified and marked before Budding Department Inspections Call (360) 473 -5870 foundation footing inspection Setbacks are measured to the WATER - Public Works - Water (360) 473 -5927 finished wall structure - Reinspection fee maybe assessed if inspection has been PW - Public Works - Engineering (36Q) 473 -5270 requested when not readyor corrections are not completed HEALTH - Kitsap Co Health District (360) 337 -5285 - Permit, approved plans, engineering, and inspection card shall Fire - Fire Department (360) 473 -5394 be on site during construction or Reinspection Fee maybe L8d - Dept of Labor and Industry (360) 415 -4000 assessed Inspection Approved Date Notes FIRE - Final Inspection L &I - Electrical Cover Inspection Before Framing (State of Washington Framing Inspection (Mechanical & Plumb Rough -In, Elect Cover 69A ,a�, �� Coin leted �( Insulation Sheetrock Nailing L &I - Electrical Final Inspection Final Inspection - Budding FINAL BUILDING (360) 473 - 5870 All of the above must be approved 74q l Occupancy approval for SFR only - Commercial structures require a separate Certificate of Occupancy DO NOT OCCUPY BUILDING WITHOUT BUILDING DEPARTMENTAPPROVAL PROTECT THIS CARD FROM THE WEATHER CITY OF BREMERTON PERMIT NUMBER BB11 00309 DEPARTMENT OF COMMUNITY DEVELOPMENT DATE ISSUED 04/18/2011 345 - 6th Street Bremerton WA 98337 ` (360) 473 -5275 Fax (360) 473 -5278 ASSESSOR NUMBER 3937 003 005 -0001 ZONING R10 SITE ADDRESS 1320 BRADLEY ST APPLICANT NAME BANKS LEROY JR & HARRIETT PHONE (360) 550 4660 ADDRESS 4765 RUTHERFORD CIR SW PORT ORCHARD WA 98367 OWNER NAME BANKS LEROY JR & HARRIETT PHONE (360) 550 4660 ADDRESS 4765 RUTHERFORD CIR SW PORT ORCHARD WA 98367 CONTRACTOR GREENLIGHT CONSTRUCTION LLC PHONE (360) 286 -1408 ADDRESS 2344 TRENTON AVE BREMERTON, WA 98310 LENDER NAME PHONE 0 _ ADJDRESS SUBMITTED 04/05/2011 APPROVED 04/18/2011 IRATION 10/15/2011 STATUS ISSUED VALUATION Adult Family Home Tenant 1 p vement Plan Review Fee $56 00 16.4560 ADULT FAMLY HOME (INCLUDES NEW WINDOW IN BEDRM #1 & CREATE Building Permit $3600 2211 BEDRM #2) State Surcharge $450 0236 Building Code Edition IRC 2009 Plan Review Fee $23 40 16 -4580 Occupancy Group R -3 TOTAL FEES $11990 Type of Construction Type V, Unprotected Flood Zone Setbacks (Front) (Side) (Rear) (Other) Sanitation Method Public Sewer System Number of Bedrooms 4 Inspection Requests FIRE Fire Inspections (360) 473 -5394 DCD Building Inspections (360) 473 -5870 HEALTH Kitsap County Health District (360) 337 -5285 L &I Department of Labor and Industries (360) 415 -4000 PW &U Public Works - Engineering (360) 473 -5270 This permit shall become null and void if the described work authorized by this permit has not commenced within 180 days from the date of issuance or if the work is suspended or abandoned at anytime after the work is commenced for a period of 180 days It is the responsibility of the permit holder to see that the required inspections are made Failure to obtain required inspections may result in stoppage of the work until such time that the permit holder can susbstantiate to the City of Bremerton that the concealed work meets or exceeds code requirements Any demolition testing or financial burden shall be borne directly by the permit holder Failure to substantiate code requirements will indemnify the City against any and all responsibility or liability connected with the construction I hereby certify that I have read and examined this permit and know the same to be true and correct All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not The granting of a permit does not presume to give authority to violate or cancel provisions of any State or local law regulating construction or the performance of the construction If listing the owner as general contractor I certify that I am exempt from the requirements of the State Contractor's Registration Law under Section 3 Chapter 126 Laws of 1967 All revisions to an approved plan require DCD review and approval prior to performing work All building and tenant occupancy permits are required to pass final inspection prior to permit expiration and obtain a certificate of occupancy prior to use or occupancy I have read, and agree to Ide by e c nditlons of this permit Including all conditions of zoning, budding codes, and State and Federal laws SIGNATURE OF OWNER OR AGENT �[ PRINTED NAME D IE CI of Bremerton's a l City a pproval of this af, I t ion, and thus compliance with City regulations does not necessarily ensu J 10 (DCD -02) DCD Validi ^ (�c� �%( - I r be construed to be a -42— permit for, c he Washington State Budding co( nits presuming to give authority to udding code or other ordinances I v/ f a permit based on construction r �fficlal from requiring the correctlo he budding official Is also autho violation of the Washington I of Bremerton 10 (DCD -01) DCD Prior t / I I und Clean Air Agency (Clean Air Ac l s (L &I) regulations require an as re asbestos- containing m, It must be conducted by, iovatlon or owner - I Page 1 of 3 A CITY OF BREMERTON PERMIT NUMBER BB11 00309 DEPARTMENT OF COMMUNITY DEVELOPMENT DATE ISSUED 04/18/2011 345 - 6th Street Bremerton WA 98337 N (360) 473 -5275 Fax (360) 473 -5278 ASSESSOR NUMBER 3937 - 003 - 005 -0001 ZONING R10 SITE ADDRESS 1320 BRADLEY ST APPLICANT NAME BANKS LEROY JR & HARRIETT PHONE (360) 550 -4660 ADDRESS 4765 RUTHERFORD CIR SW PORT ORCHARD WA 98367 OWNER NAME BANKS LEROY JR & HARRIETT PHONE (360) 550 -4660 ADDRESS 4765 RUTHERFORD CIR SW PORT ORCHARD WA 98367 CONTRACTOR GREENLIGHT CONSTRUCTION LLC PHONE (360) 286 1408 ADDRESS 2344 TRENTON AVE BREMERTON, WA 98310 LENDER NAME PHONE 0 ADDRESS SUBMITTED 04/05/2011 APPROVED 04/18/2011 EXPIRATION 10/15/2011 STATUS ISSUED occupied single family residences) DCD For more Information, please contact Clean Air Agency through their web site at www cleanair org or by phone at 800 - 552 -3565 or 206- 689 -4058 The L &I web site can be found at www Inl wa gov /p -ts /asbestos /asbestos htm 10 (DCD -47) DCD Reinspection Fee All approved plans, the printed budding permit, and the permit inspection placard, are required to be on -site for Inspection purposes, and work to be inspected shall be complete and ready for inspection If an inspection is called for and plans are not available on site, or the work is not ready for inspection, approval will not be granted In addition, a re- inspection fee will be charged and must be collected by the Department of Community Development prior to any further inspections being performed or approvals granted � h 11 (OTHER) Development must comply with BMC Title 20 12 (LU9) All driveways and areas used for loading, parking, and maneuvering motorized vehicles C shall have a paved surface pursuant to BMC 20 48 An adult family home requires 2 off - street parking spaces plus 1 for each bedroom beyond the first 4 plus 1 space for each 300 square feet of counseling As this building has 4 bedrooms and office space, 3 off - street parking spaces are required U, ,� 13 (DCD -04) DCD Plan Review Requirements The attached plan review checklist and identified , ( / 2 corrections, along with the Energy Compliance Worksheet (when applicable) are part of the approved plans and must remain attached thereto It Is the responsibility of the applicant to make the corrections indicated on the plans Once the plans are marked "APPROVED ", they shall not be changed or altered without authorization from the Building Official All proposed changes to "APPROVED" building plans that effect compliance with the City of Bremerton Building and Fire Code as adopted and amended in BMC Title 17 and Title 18, or any other City of Bremerton ordinance or regulation, must be reviewed and approved by the Department of Community Development prior to construction Failure to comply and /or removal of attached documents will result in failure of required building Inspections 14 (DCD -28 AFH) Adult Family Homes Residential homes licensed to care for up to six non - related residents, in which room, board, laundry, necessary supervision, and necessary help with activities Of daily living, personal care, and social services are provided RCW 70 128 010 15 (DCD -06) DCD Energy code compliance stickers shall remain on windows until framing inspection is approved by Building Department 16 (DCD -16) DCD At least one operable emergency escape and rescue opening shall be provided in each sleeping room and basement, with a sill height less than or equal to 44" above the floor, minimum clear opening of 5 7 sq ft, minimum width of 20" and minimum height of 24" 17 (OTHER) The bedroom downstairs Identified as a "Caregiver Bedroom" shall not be used as a sleeping room The window sill height does not comply with the maximum sill height of 44" A bedroom upstairs was created by erecting walls between the kitchen and main living area The walls that were constructed on each floor may have to be uncovered to facilitate a framing inspection Hard -wired smoke alarm with battery backup Is required for Bedroom #2 (new bedroom created under this permit) 50 (DCD -50) Final Inspection Required All building permits shall have a final Inspection performed and approved by the City of Bremerton Department of Community Development prior to permit expiration The failure to request a final inspection or failure to obtain final approval prior to Page 2 of 3 CITY OF BREMERTON PERMIT NUMBER 8611 00309 DEPARTMENT OF COMMUNITY DEVELOPMENT DATE ISSUED 04/18/2011 345 - 6th Street Bremerton WA 98337 ` (360) 473 -5275 Fax (360) 473 -5278 ASSESSOR NUMBER 3937 - 003 - 005 -0001 ZONING R10 SITE ADDRESS 1320 BRADLEY ST APPLICANT NAME BANKS LEROY JR & HARRIETT PHONE (360) 550 4660 ADDRESS 4765 RUTHERFORD CIR SW, PORT ORCHARD WA 98367 OWNER NAME BANKS LEROY JR & HARRIETT PHONE (360) 550 4660 ADDRESS 4765 RUTHERFORD CIR SW, PORT ORCHARD, WA 98367 CONTRACTOR GREENLIGHT CONSTRUCTION LLC PHONE (360) 286 1408 ADDRESS 2344 TRENTON AVE BREMERTON WA 98310 LENDER NAME PHONE 0- ADDRESS SUBMITTED 04/05/2011 APPROVED 04/18/2011 EXPIRATION 10/15/2011 STATUS ISSUED expiration may require a reactivation fee, or a new permit application If more than a year has passed with no activity MINIMUM INSPECTIONS REQUIRED To request an inspection, please call (360) 473 -5870 and be sure to provide your permit number, name on permit, site address, contact phone number, and inspection type To register for on -line Inspection access, visit the City's website at www cl bremerton wa us FIRE - Final Inspection L &I - Electrical Cover Inspection Before Framing (State of Washington) Framing Inspection (Mechanical & Plumb Rough -In, Elect Cover Completed) Insulation Sheetrock Nailing L &I - Electrical Final Inspection Final Inspection - Building Page 3 of 3 FI LI�L ^e l � O O s RECEYVEI� cityofBremerto C �1� l�l R C P 1 �j APR 05 2011 � ( � Department of COMM • •' • CommumtyDevelopment Building Permit Application Department of Commumtv Development * 345 - 6th Street: Suite 600 * Bremerton, WA 98337 -1873 (360) 473 - 5275 * Fax (360) 473 * www ci bremerton wa us IN M-11 Business Name: C? u , _.2_ L LL Site Address- 1 Sj= Rre m-e-ri -- oll To apply for a property address, contact Fitiblic Works at (380) 473 -5270 CONTRACT re.e.n1 C0v 'rW_+( O WNER' LS Address 33 f Al et.74 C_ 6 o,,J Address r 6t City, State, Zip 7d c„_ City, State, ZI Q & k 3107 License # & Exp Date O -:Z A' Phone # 6 Ll 6 (o 6) Contact Name a Authorized Agent Name' 4 cilv r t v 9 Contact Phone # o 6 1 Address I-I (o Glr Email address ca., r 7 4 , v , c Or — City, State, Zip vv Or ca rd w rt Tax ID /Parcel #• Phone # (3(&Vj 1 _2 q5r cq Sewer ❑ Septic Email address i • Gore ❑ NEW COMMERCIAL ❑ TENANT IMPROVEMENT WITH WORK ❑ COMMERCIAL REMODEL ❑ TENANT IMPROVEMENT WITHOUT WORK ❑ COMMERCIAL ADDITION ❑ NEW SIGN ❑ COMMERCIAL REPAIR ❑ GRADING (Cubic Yards ) ❑ NEW MULTI - FAMILY ❑ REROOF ❑ DEMOLITION _ Interior Exterior*" _ Foundation Wail" _ Roof / Section ** ** Separate demolition permit and fees required Contact Public Works for sewer cap permit (473 -5270) Sewer must be capped pnor to demolition permit issuance ❑ OTHER IS THIS PROPERTY WITHI 200 FEET OF SHORELINE? YES[ NO [� Scope of work proposed - ,( �� �, „ i n b_2G rco n - 4:4- - - _ \ tit n c, �- t►�ol Cc.yt 1� 1-{ C c�cl c-LI f - rim t 1" f�rn e Square Footage: Building 9-1 (o y Construction Type Valuation Plan Review Fee Permit Fee Surcharge Total Fees 6� Application for which no permit Is Issued within 1 days following the date of application shall expire by limitation, and plans and other data submitted for review may thereafter be returned the applicant or destroyed by the budding official The budding official may extend the time for action by the applicant for a period not exceeding 180 days on request by the applicant, showing the circumstances beyond the control of the applicant have prevented action from being taken No applicant shall be extended more than once In order to renew action on an application after e3wation, the applicWt shall resubmit la d pay a new plan review fee Appl!qpFO Signifture Date Rev July 2008 Questions on this sheet, please contact Mike Six, Fire Marshal (360) 473 -5386, or email Michael Six@ci bremerton wa us Bremerton Fire Department Fire Marshal's Office Construction Assistance Bulletin Operations checklist Project Address: 13 Zo g� (ev S f- Primary Contact: f - }��u`, e �- R.a� Email: C411 Below is a checklist of activities which this occupancy will be performing during day to day operations not during construction Please check all that apply Also, please provide a copy (In both PDF and DWF /DWG format) of ALL drawings and specifications for this protect Please check all that appl Aviation Battery Back Card swipe system Compressed Gases u Cooking Corrosives Cryogenics Emergency Generator Fireworks Flammable Flammable /Combustible Forklifts Material I Liquids Gates Hot-work Large Ovens LPG Lumbertwood Motor vehicle Painting /powder coating Racks (12' or more in p roducts repair height Refrigeration Storage >6' Tire Storage Dust products will be System I I high produced Place a check next to any item that will be addediremoved or otherwise modified DURING CONSTRUCTION ONLY... Electrical Plumbing Fire Alarm Fire Sprinkler Hood System Walls HVAC Storm/Septic Building Access Site changes Windows Stairs Elevator Doors Building security ALL NEW CONSTRUCTION Items not mentioned of Re; r gran ing of a permit• lL� ` Z Pall nOt be Co strued to be a permit for, or An appro tal- 6L any +/i0latio of the provisions of the Intern ational �ode5 or any her ordnance of the City of Bremerton, v P ©rrflit5 presu ing to give authority to violate or cancel I the provisions Qhe International Codes and ordinances oft ty of Bremerton shall not be valid /// "`��� v I �. (IBC 105 & A *4) y t l cfz� 3 rn Q moo © � N�Cle -MUST BE APPROVED PRIOR- w�kp, O PTO PERFORMING WOR CMED b '� � a OY1 tSp �� ` C of Bremerton s � 1s N ,; L s - APR 0 5 2011 $ (L9 Sa. atlre �°4 u ol Department of Community Development MUST COMPLY WITH 1 ALL WASHINGTON STATE C 6AT /J)R 0 0 0 *1 Cr 0 i � 3 � �p s G i �t ro ►s cx� nu,Mbbred� Of IRE P ill C1 e !`4nA Q-A, &8: C ot'h►3 ' 'fit. 1 •t'h.�. 5' m exLA SEA Al *AC pLAO APR I ,. 01j W NB WING F?XpI,ANPT C� - �, ®Y' o �MM UN1 / RECEDT - QV of Brem, APR ® 5 ,gyp 40 _ a4 `91,4-010 1�0 orati sl *ed expae� "ink shell De Inslled s e w ,a the manufacturer's Instructlons for drigen water Fpatert on any supp� provided wo e 8 3 ®sure fetlulatng device or check valve 'PC 3)Leh Km — � T 4 V' L-J:h ?�o new wmdou) AD S vvt WASHINGTON STATE AMENDMENTS R314.4 Power source. Smoke alarms shall receive their pn- mary power from the building wiring when such wiring is served from a commercial source, and when primary power is interrupted, shall receive power from a battery Wiring shall be permanent and without a disconnecting switch other than those required for overcurrent protection Smoke alarms shall be interconnected Exceptions: 1 Smoke alarms shall be permitted to be battery oper- ated when installed in buildings without commercial power 2 Interconnection and hard -wiring of smoke alarms in existing areas shall not be required where the alter- ations or repairs do not result in the removal of inte- nor wall or ceiling finishes exposing the structure, unless there is an attic, crawl space or basement avail- able which could provide access for hard wiring and interconnection without the removal of interior fin - ishes R314.3 Location. Smoke alarms shall be installed in the following locations 1 In each sleeping room 2 Outside each separate sleeping area in the immediate vicinity of the bedrooms 3 On each additional story of the dwelling, including basements and habitable attics but not including crawl spaces and uninhabitable attics In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level 4 In napping areas in family child day care homes When more than one smoke alarm is required to be installed within an individual dwelling unit, the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the individual unit R314.3.1 Alterations, Repairs and Additions. When alterations, repairs or additions requiring a permit occur, or when one or more sleeping rooms are added or created in 8313.1 Automatic fire sprinkler systems. This section is existing dwellings, the individual dwelling unit shall be not adopted equipped with smoke alarms as required for new dwellings Exceptions 1 Work involving the exterior surfaces of dwellings, such as the replacement of roofing or siding, or the addition or replacement of windows or doors, or the addition of a porch or deck are exempt from the requirements of this section 2 Installation, alteration or repairs of plumbing, electrical or mechanical systems are exempt from the requirements of this section (Insert Facing Page 62) Effective July 1, 2010 Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2009 IRC Section R325 (WAC 51.51) APPLICATION NUMBER: SECTION 1 3 AND 4 BEFORE INSPECTION WILL BE PROCESSED SECTION PROPERTY INFORMATION SITE ADDRESS. ASSESSORS TAX/PARCEL# _ _ _ _ _ _ _ SECTION •• •• • PROPERTY OWNER NAME DAYTIME PHONE AFH LICENSEE NAME (7 DTffRErn) DAYTIME PHONE SECTION FLOOR APPLICANT MUST DRAW COMPLETE FLOOR PLAN /s ON THIS FORM (ALL FLOORS). PLEASE INCLUDE ALL SLEEPING ROOMS (BEDROOMS). ON 7HZ5M4WINC INDICATE WHICH BEDROOM IS A, B. C,Q- AND F. WEL ALL compoNENIg Fog gZinNG ,f.2 : m Rs. RAMPS, PLATFORM LIFTS & ELEVATORS. SECTION • BLOCK I certify under penalty of pequry that the information furnished by me is true and correct to the best of my knowledge, and that I am requesting or I am authorized by the owner of the above premises to request inspection for the operation of an Adult Family Home at this location I agree to hold harmless the jurisdiction conducting such inspections, at my request, as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation of such claim), which may be made by any parson, including the undersigned, and filed against the jurisdiction, but only where such claim arises out of the reliance of the jurisdiction, including its officers and employees, upon the accuracy of the information supplied to the junsdiction as a part of this application NAME/TITLE: DATE: ❑ PROPERTY OWNER ❑ APPLICANT ❑ LICENSEE 08101110 (E f fective July 1, 2010) WAC 51 -51 -0325 Section 8325 — Adult family homes. SECTION 8325 ADULT FAMILY HOMES R325.1 General. This section shall apply to all newly constructed adult family homes and all existing single family homes being converted to adult family homes This section shall not apply to those adult family homes licensed by the state of Washington department of social and health services prior to July 1, 2001 R325.2 Submittal Standards. In addition to those requirements in Section 106 1, the submittal shall identify the project as a Group R -3 Adult Family Home Occupancy A floor plan shall be submitted identifying the means of egress and the components in the means of egress such as stairs, ramps, platform lifts and elevators The plans shall indicate the rooms used for clients and the sleeping room classification of each room R325.3 Sleeping Room Classification. Each sleeping room in an adult family home shall be classified as 1 Type S - where the means of egress contains stairs, elevators or platform lifts 2 Type NS1- where one means of egress is at grade level or a ramp constructed in accordance with R325 9 is provided 3 Type NS2 - where two means of egress are at grade level or ramps constructed in accordance with R325 9 are provided R325.4 Types of Locking Devices. All bedroom and bathroom doors shall be openable from the outside when locked Every closet shall be readily openable from the inside Operable parts of door handles, pulls, latches, locks and other devices installed in adult family homes shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist The force required to activate operable parts shall be 5 0 pounds (22 2 N) maximum Exit doors shall have no additional locking devices R325.5 Smoke Alarm Requirements. All adult family homes shall be equipped with smoke alarms installed as required in Section R314 Alarms shall be installed in such a manner so that the fire warning may be audible in all parts of the dwelling upon activation of a single device R325.6 Escape Windows and Doors. Every sleeping room shall be provided with emergency escape and rescue windows as required by Section R310 No alternatives to the sill height such as steps, raised platforms or other devices placed by the openings will be approved as meeting this requirement R325.7 Fire Apparatus Access Roads and Water Supply for Fire Protection. Adult family homes shall be served by fire apparatus access roads and water supplies meeting the requirements of the local ,jurisdiction R325.8 Grab Bars. Grab bars shall be installed for all water closets and bathtubs and showers The grab bars effective WAC 51 -51- 0325 Section R325 — Adult family homes date 7/1/10 shall comply with ICC/ANSI Al 17 1 Sections 604 5 and 607 4 and 608 3 EXCEPTION: Grab bars are not required for water closets and bathtubs and showers used exclusively by staff of the adult family home. R325.9 Ramps. All interior and exterior ramps, when provided, s be constructed in accordance with Section R311.8 with a maximum slope of 1 vertical to 12 horizontal The exception to R311.81 is not allowed for adult family homes Handrails shall be installed in accordance with R325 9 1 R325.9.1 Handrails for Ramps. Handrails shall be installed on both sides of ramps between the slope of 1 vertical to 12 horizontal and 1 vertical and 20 horizontal in accordance with R311 6 3 1 through R311 6 3 3 R325.10 Stair Treads and Risers. Stair treads and risers shall be constructed in accordance with R310.4 Handrails shall be installed in accordance with R325 10 1 R325.10.1 Handrails for Treads and Risers. Handrails shall be installed on both sides of treads and risers numbermg from one riser to multiple risers Handrails shall be installed in accordance with R311.7.7 through R311.7.7.4 [Statutory Authority RCW 19 27 190, 19 27 020, and chapters 19 27 and 34 05 RCW 09- 04 -023, §51 -51 -0325, filed 1/27/09, effective 7/1/10 Statutory Authority RCW 19 27 074, 19 27 020, and chapters 19 27 and 34 05 RCW 07 -01 -090, § 51 -51 -0325, filed 12/19/06, effective 7/1/07 Statutory Authority RCW 19 27 031 and 19 27 074 04-01 -109, § 51 -51 -0325, filed 12/17/03, effective 711/04 j 08101110 �r N A M E OF AFH: SECTION 5 MUST SBE COMPLETED_SY..IHE BUILDING DEPARTMENT IN THE JURISDICTtDN THE HOME WILL BE LOCATED PLEASE CHECK ALL APPLICABLE BOXES MATCH THE LIST BELOW TO THE APPLICANT'S FLOOR PLAN - USING THEIR PR SPIMME DESIGNATIONS OF A B C D -E-AND-Ow AND CLASSIFICATION CODE'S NSI, OR NS2 SECTI •• INSPECTIO R325.3 S I EEPiNG Room CIASSIFIC Each sleeping room In an adult family home shall be classified as Type S - where the means of egress contains stairs, elevators or platform lifts to evacuate residents to public area Type NS1-where 1 means of egress at grade level (has no stairs), or a ramp constructed compliant with 8325 9 Is provided to evacuate residents to public area Type NS2 - where 2 means of egress at grade level (both have no stairs), or ramps constricted compliant with 8325 9 are provided to evacuate residents to public area L EEPI NG Sleeping Room A ❑ Type S ❑ Type NS1 ❑ Type NS2 YES NO Closet doors are readily openable from the Inside I YEs ❑ 1 NO ❑ Smoke alarm is installed in the bedroom ❑ ❑ Bedroom door Is easily and quickly openable from the outside when locked ❑ ❑ Sleeping room window has a net opening of 5 7 SF* (minimum dimensions at lea 24" nigh. at least 20" wide) ❑ ❑ * EXCEPT PER 8310 11 AT -GRADE ESCAPE WINDOWS -MAY HAVE NET CLEAR OPENNG 5 SF Sleeping room window has a maximum all height of 44" above floor, no steps under window permitted ❑ ❑ Sleeping Room B ❑ Type S ❑ Type NS1 ❑ Type NS2 YES NO Closet doods are readily openable from the Inside 1 YES ❑ 1 NO ❑ 1 Smoke alarm Is Installed In the bedroom ❑ ❑ Bedroom door Is easily and quickly openable from the outside when locked ❑ ❑ Sleeping room window has a net opening of 5.7 SF* ( dimensions at least 24" high. at least 20" wide) ❑ ❑ * EXCEPT PER R310 11 AT -GRADE ESCAPE WINDOWS -MAY HAVE NET cLm OPENING 5 SF Sleeping room window has a maximum sill height of 44" above floor, no steps under window permitted ❑ ❑ Sleeping Room C 13 T S ❑ T NS1 ❑ T NS2 YES NO Closet door /s are readily openable from the Inside YES ❑ 1 NO ❑ Smoke alarm Is Installed In the bedroom ❑ ❑ Bedroom door Is easily and quickly openable from the outside when locked ❑ ❑ Sleeping room window has a net opening of 5.7 SF* ( minimum dimensions at least 24" hlgn at least 20" wide) ❑ ❑ * EXCEPT PER R310 11 AT -GRADE ESCAPE WINDOWS -MAY HAVE NET CLEAR OPENING 5 SF Sleeping room window has a maximum sill height of 44" above floor, no steps under window permitted ❑ ❑ Sleeping Room D 13 T S [3 T NS1 ❑ T NS2 YES NO Closet doors are readily openable from the Inside YES ❑ 1 NO ❑ 1 Smoke alarm Is Installed In the bedroom ❑ ❑ Bedroom door Is easily and quickly openable from the outside when locked ❑ ❑ Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24" high at least 20" wide) ❑ ❑ * EXCEPT PER 8310 11 AT -GRADE ESCAPE WINDOWS -MY HAVE NET CLEAR OPENING 5 SF Sleeping room window has a maximum sill height of 44" above floor, no steps under window permitted ❑ ❑ Sleeping Room E 1 ❑ Type S ❑ Type NS1 1 ❑ Type N32 YES NO Closet door /s are readily openable from the Inside YES ❑ 1 NO ❑ 1 Smoke alarm Is Installed In the bedroom ❑ ❑ Bedroom door Is easily and quickly openable from the outside when locked ❑ ❑ Sleeping room window has a net opening of 5.7 SF ( minimum dimensions at least 24" hlan at least 20" wide) ❑ ❑ * EXCEPT PER R310 11 AT -GRADE ESCAPE WINDOWS -MAY HAVE NET CLEAR OPENING 5 SF Sleeping room window has a maximum sill height of 44" above floor, no steps under window permitted ❑ ❑ Sleeping Room F ❑ Type S ❑ Type NS1 1 ❑ Type NS2 YES NO Closet door /s are readily openable from the Inside I YEs ❑ 1 NO ❑ 1 Smoke alarm Is Installed In the bedroom ❑ ❑ Bedroom door Is easily and quickly openable from the outside when locked ❑ ❑ Sleeping room window has a net opening of 5.7 SF* (minimum dimensions at least 24" hlah at least 20" wide) ❑ ❑ * EXCEPT PER R310 1 1 AT -GRADE ESCAPE WINDOWS -MAY HAVE NET CLEAR OPENING 5 SF Sleeping room window has a maximum sill height of 44" above floor, no steps under window permitted ❑ ❑ ifflEft YES NO Bathroom doors are easily and quickly openable from the outside when locked ❑ ❑ S moke alarms are installed on all levels of the dw e IlinR, In each resident sleeping room, outside each separate sleeping ❑ ❑ area In the Immediate vigil of sleeping rooms R31 S moke alarms are install In such a manner so that the fire warning may be aud In all parts of the dwelling upon activation of a single device Access road and water supply meet local fire jurisdictional requirements ❑ ❑ 08101110 r R311.8 Rarri WA YES NO R311 81 Maximum Slope one unit vertical in twelve units horizontal 8 3 0 /6 sloe (Exception R311 81 Not allowed in AFH ❑ ❑ R3118 2 Landing Requirements min 3X3 foot landing at top/bottom, where doors open onto ramps, and where ramp ❑ ❑ changes directions R325 91 Handrails required on both sides of ramp in accordance with R311 8 31— R311 8 3 3 ❑ 1 ❑ O=dg &M I NIA YES I NO R311 8 1 Maximum Sloe one unit vertical in twelve units horizontal (8 3% slope) (Exception R311 81 Not allowed in AFH) ❑ ❑ R311 8 2 Landing Requirements min 3X3 foot landing at top /bottom, where doors open onto ramps, and where ramp ❑ ❑ changes directions R325 91 Handrails required on both sides of ramp in accordance with R311 8 31— R311 8 3 3 ❑ ❑ 'Guards below are depicted vertically as an example only All Ramas musl have Guards Less than 4" Handrail both sides 34" — 38" Guard 36" min 3'xTmm Tx 3' min L— landing landing 112 max slope C== 3' 83% mm mm ADULT FAMILY HOME RAMP per 2009 IRC with WA. ST. AMENDMENTS *ALL RAMPS REQUIRE A BUILDING PERMIT* R311.2 Means of Egiress YES NO R3112 Door must be side-hinged with min width of 32 inches between face of door and stop Height not less than 78 inches ❑ ❑ R325 4 Operable parts of door handles, pulls, latches, locks and other devices installed in AFH shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist (lever -type, emergency egress hardware) The E)at doors ❑ ❑ shall have no additional locking devices R3117 Stalrwa Nl YES NO R3117 41 Riser Height Max nser height shall be T 8 inches in structures built prior to July 1, 2004 ❑ ❑ R3117 4 2 Tread Depth Min tread depth shall be 10 I e 9 inches in structures built prior to July 1, 2004 ❑ ❑ R325 10 1 Handrails for Treads and Risers shall be installed on both sides of treads and risers numbering from one nser tD ❑ ❑ multiple risers Handrails shall be Installed in accordance with R3117 71— R3117 7 4 R3252 Grab Bars in Bathrooms (MlyMguire"afternate"armroval in accordance with IRC Sec R10410 and 11 YES NO 8325 & Grab bars shall be installed for all water closets (toilets), bathtubs and showers Bathing facilities such as tubs and showers, and ❑ ❑ On both sides of the toilet shall comply with ICCIANSI Al 171 Sections 604 5,607 4 & 608 3 ❑ ❑ AG103 - AG 105 Swimming Pool S Hot Tub I NJAI YES NO AG105 2 Must be surrounded by a barrier that is 48 inches high, may have doors and or gates that must have audible ❑ ❑ alarms when opened AG105 5 EXCEPTION Pools, Spas or hot tubs with a safety cover which complies with ASTM F 1346 01 ❑ ❑ PASSED ❑ CORRECTIONS REQUIRED ❑ PERMIT REQUIRED INSPECTOR'S SIGNATURE: DATE: INSPECTOR'S ADDRESS: PHONE: Application and Inspection Checklist developed by Washington Association of Building Officials (WABO), in cooperation with Department of Social and Health Services (DSHS) for use by both departments and licensors 08!01110 City of Bremerton Department of Community Development 345 - 6 Street, Suite 600 Bremerton, WA 98337 -1873 Phone: (360) 473 -5275 • Fax: (360) 473 -5278 Inspections: (360) 473 -5870 RESIDENTIAL PLAN REVIEW CHECKLIST Mao n o p &rl"'a aff qNG fpprTonGd OG12 oa po &imo' DO IMQ12 ITGMi.OM(�) 0opf1FW2(9) OP Permit Number Owner • 2009 International Residential Code, WAC 51 -51 (Chapters 1 -10, 12 -24, Appendix G & R) • 2009 Washington State Energy Code (WSEC), WAC 51- 11(2006 Edition until January 1, 2011) • 2009 Uniform Plumbing Code, WAC 51 -56 and 51 -57 • 2009 International Mechanical Code and 2009 International Fuel Gas Code, WAC 51 -52 • Bremerton Municipal Code Title 17 & 18 The numbered items on the following pages are associated with the above referenced codes, as adopted and amended by the City of Bremerton This checklist is intended to provide basic, helpful information only, and shall not be construed as an all- inclusive list of code requirements In order to aid with the transition from the 2006 International Residential Code to the 2009 International Residential Code, substantial code changes or differences between the 2006 IRC and the 2009 IRC codes are in bold type. Because of copyrighted material, the unamended codes are not available online Building codes may be researched in the Department of Community Development office or the Sylvan Way branch of the Kitsap Regional Library The state amendments to the codes may be found at www sbcc wa gov The Energy Code may be researched at www energy wsu edu The issuance or granting of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Bremerton Building & Fire Code or any other ordinance of the city of Bremerton Permits presuming to give authority to violate or cancel the provisions of the codes and ordinances of the City of Bremerton shall not be valid Office hours are from 8 00 a m to 5 00 p m Monday through Thursday To schedule an inspection, call (360) 473 -5870 and provide your permit number, the name and address shown on the permit, the type of inspection needed, and a contact telephone number Inspection requests must be made before 7 30 a m by telephone in order to be scheduled for the same business day You can also sign into the Online Center at www bremerton wa us /PublicPortal Online requests must be made by midnight the day before the requested date We do NOT call to confirm the inspection nor make an appointment The final building inspection will not be approved until other agency final inspections have been performed and approved (Public Works, Water Maintenance, Electrical, and Health, if on septic system) City of Bremerton Department of Community Development (360) 473 -5275 345 6 h St , Suite 600 Inspections (360) 473 -5870 Bremerton, WA 98337 Fax (360) 473 -5278 3/16/2011 A Budding permit is required to construct, enlarge, alter, well as outside each separate sleeping area in the repair, move, demolish or change the occupancy of a immediate vicinity of the bedrooms, and each building or structure, or to erect, install, enlarge, alter, additional story of the dwelling including basements repair, remove, convert or replace any electrical, gas, (but excluding crawl spaces and uninhabitable mechanical or plumbing system Exceptions include a attics ) In dwelling units with split levels and without fence less than 6 feet in height One -story tool sheds or an intervening door between the adjacent levels, a playhouses less than 200 square feet, retaining wall smoke alarm installed on the upper level shall less than 4' in height measured from the bottom of the suffice for the adjacent lower level provided that the footing and not supporting a surcharge, interior finish lower level is less than one full story below the such as paint or carpet, prefabricated swimming pools upper level When more than one smoke alarm is less than 24" high, residential playground equipment, required to be installed within an individual dwelling window awnings less than 54" from the exterior wall unit, the alarm devices shall be interconnected in and not requiring additional support, and residential such a manner that the actuation of one alarm will reroofs less than 4,000 square feet Other exceptions activate all of the alarms in the individual unit may apply Contact the office to answer any questions Alterations, repairs and additions shall be Electrical permits are available from Washington State equipped with smoke alarms located as required Labor & Industries for new dwellings, except work performed only on the outside, or plumbing or mechanical work FLOOR PLAN only. Interconnection and hardwiring is not required in existing buildings if the alterations 1 ROOM IDENTIFICATION: IRC Section R105 3 do not result in the removal of wall or ceiling Each room and its intended use must be clearly finishes unless there is a basement, attic, or shown on the plans by the applicant for plan crawl space which could provide access for review purposes hardwiring and interconnection without removing the interior finish. Note Habitable 2 EGRESS WINDOWS IRC Section R310 1 rooms such as dens, libraries and offices that are Basements, habitable attics, and every sleeping provided with built in features that establish the room shall have at least one operable emergency specific use of the room as something other than for escape and rescue opening (Habitable attic is a sleeping, and do not contain clothes closets, need conditioned attic area with an occupiable floor not be considered a sleeping room area of 70 square feet and ceding height of at 3a. CARBON MONOXIDE ALARMS: IRC Section 315. least 7 feet over minimum area of 35 square feet) In dwellings where fuel -fired appliances exist or Windows shall have a minimum net clear that have attached garages, an approved carbon openable area of 5 7 square feet, or, minimum of monoxide alarm listed with UL 2034 shall be 5 0 square feet for grade floor openings The installed outside of each separate sleeping area minimum clear opening height shall be 24 ", and in the immediate vicinity of the bedroom, unless the minimum clear opening width shall be 20" The the dwelling has been owner - occupied prior to window shall have a finished sill height at 44" or July 1, 2010. In a building where a tenancy less above the floor Emergency escape and exists, the tenant shall maintain the CO alarm as rescue openings shall be operational from the specified by the manufacturer including inside of the room without the use of keys, tools, replacement of the batteries In existing or special knowledge Window wells shall be dwellings with existing fuel appliances, the CO provided when egress windows have a finished sill alarm shall be installed by January 1, 2013. height below the adjacent ground elevation The well shall allow the window to be fully opened and 4 SAFETY GLAZING IRC Section R308 4 All glass provide a minimum accessible net clear opening located in an area considered hazardous must be of 9 square feet, with a minimum dimension of safety glazed 36" Window wells with a vertical depth of more 1 Glazing in all fixed and operable panels of than 44" shall be equipped with a permanent swinging, sliding and bifold doors, except de- ladder or steps See Page 24, Emergency Egress/ corative glazing and glazed openings Rescue Opening, for additional information 2 Glazing adjacent to a door where the nearest 3 SMOKE ALARMS: IRC Section R314.1 A vertical edge is within a 24" arc of the door in a smoke alarm listed in accordance with UL217 closed position and whose bottom edge is less shall be installed in each sleeping room, including than 60" above the floor or walking surface each bedroom, bonus room, habitable attic, and Exceptions decorative glazing, an intervening other habitable rooms that could potentially be wall or permanent barrier is between the door sleeping rooms that contain an intervening door and the glazing, glazing is in a wall on the latch that can be closed to separate the room from side of the door and perpendicular to the plane areas otherwise provided with smoke alarms, as of the door in a closed position, glazing CITY OF BREMERTON DEPARTMENT OF COMMUNITY DEVELOPMENT RESIDENTIAL PLAN REVIEW CHECKLIST 2 adjacent to a door giving access to a closet 5 NATURAL LIGHT & VENTILATION IRC Section which is less than 3' in depth, and glazing R303 1 and R303 2 All habitable rooms shall be adjacent to the fixed panel of a patio door provided with aggregate - glazing area of not less 3 Glazing that meets all of the following than eight percent (8 %) of the floor area of such conditions rooms, except for rooms which have artificial light A Exposed area of an individual pane is capable of average illumination of 6 foot - candles at greater than 9 square feet and a height of 30" above floor level An adjoining room B Exposed bottom edge is less than 18" may be considered under certain conditions of above the floor and R303 1 1 Ventilation shall be provided through C Exposed top edge is greater than 36" source specific and whole house ventilation systems above the floor and designed and installed as specified in Sections D 1 or more walking surfaces are within M1507 and M1508 See Items 113 -119 36" horizontally of the plane of the 6 EXHAUST FANS: IRC Section M1507, IMC 5012, glazing 50121 Source specific exhaust ventilation is Exceptions Decorative glazing, a rail at least 1'/ :" high and capable of withstand- required in each kitchen, bathroom, water closet, rng a horizontal force at least 50 pounds laundry room, indoor swimming pool, spa, and other per linear foot without contacting the rooms where water vapor or cooking odor is glass is installed in front of the glazing produced Exhaust fans providing source specific 34" to 38" above the walking surface, or ventilation shall have a minimum fan flow rating not outboard panes in insulating glass units less than 50 cfm at 0 25 inches water gauge for - and other multiple glazed panels when the bathrooms, laundries, or similar rooms and 100 cfm bottom edge of the glass is 25 feet or at 0 25 inches water gauge for kitchens The air more above grade, roof, walking surfaces removed by every mechanical exhaust system shall or other horizontal surface adjacent to the be discharged outdoors Air shall not be exhausted glass exterior. into an attic, soffit, ridge vent, or crawl space See 4 Glazing in railings regardless of area or the energy section of this checklist for additional height above a walking surface. requirements 5 Tub, shower, hot tub, whirlpool, sauna, & 7 CLOTHES DRYERS: IRC Sections M1502, G2439 3 steam room enclosures and any glazing in a & G2439 5 Clothes dryer exhaust ducts shall bathroom wall enclosure, where the bottom is terminate outside the budding at least 3 feet away from less than 60" above the walking surface any openings and be equipped with a backdraft Exception: Glazing more than 60" mea- damper Exhaust ducts shall be constructed of sured horizontally from the waters edge of minimum 0 016 - inch -thick rigid metal ducts, having a hot tub, whirlpool or bathtub. smooth interior surfaces with points running in the 6 Glazing in walls and fences used as the direction of air flow Ducts shall not be connected with barrier of indoor and outdoor swimming pools sheet metal screws or other fasteners which could and spas when the bottom edge of the obstruct the flow Exhaust ducts shall be supported glazing is less than 60" above a walking at 4' intervals and secured in place. Approved (UL surface and the glazing is within 5' of the 2158A) transition duct of not more than 8' in length water's edge may be used within a dwelling, provided they are not 7 Glazing within 36" horizontally of a walking concealed within construction Duct length shall not surface and adjacent to stairways, landings exceed a total combined vertical and horizontal length and ramps when the exposed surface is less of 25' from the connection of the transition duct than 60" above the plane of the walking from the dryer to the outlet terminal The maximum surface Exception: A rail, guard or wall is length of the duct shall be reduced in accordance installed meeting conditions of R308.4(7). with Table M1502.4.4.1, except the manufacturer's 8 Glazing within 60" horizontally of the bottom instructions may prevail if the instructions are tread of a stairway in any direction when the provided to the inspector at the time of the exposed surface of the glass is less than 60 concealment inspection. No screens shall be inches above the nose of the tread Excep- installed at the duct termination Where the duct is tions: Guardrail or handrail complies with concealed within the budding construction, the R311.7.6 and R312 and the glass is more equivalent length of the exhaust duct shall be than 18" from the railing, or a solid wall or identified on a permanent label or tag located panel extends 34" to 36" above walking within 6' of the exhaust duct connection. surface and top of wall can withstand same forces as a guard. CITY OF BREMERTON DEPARTMENT OF COMMUNITY DEVELOPMENT RESIDENTIAL PLAN REVIEW CHECKLIST 3 I: -~.,...-c~ .. . - I' .. . ,\P:. L ~:";,, I ~, f BRIM & R ~ ON B U I L Dr N G D E PAR T M EN T ~ ~ ~.'." PER M IT r ===.===============.=======c~========================================= I AP.Plication Date 07/08./1992 Applicati?n Number 92AP05394 ,II' [ Issue Date 07/08/1992 permi t Number 13503 , I Asse~sor Acct # Project Group '1' ". Si te Lo.cation 1320 BRADLEY STREET Owner - Last. Name ROOD First MADALINE MI - Street 1320 BRADLEY STREET ""City BREMERTON state WA Zip 98310 - Phone (206) - Tenant Vs Name Phone(206) -I Agent's Name '. Phone(206) - .1. Architect's Name [X] BUilding [ ] Grading [ ] Sign [ ] paVing [ ] Mechanical [] Move;Building [] Burning [ ] .Underground r ] Plumbing [ ) Mobile Home [] Land Clear [] Demolition ~~-----------~-----....,...,._---~-------------~-------------------.------- I Building Contractor: 1 Contractor INNOVATIjVE DESIGN AND DEV. street P.O. BOX 2252 . . Ci ty SILVERDALE Phone (206) 373-9942 StateWA Zip 98383 Representative SHANE HAMILTON State License # INNOVDD088KAExpirationDate 05/01/1.993 city License tExpira,tionDate Nature of Work: 21 sqtiarescomposition roofing ( I'. Building valuation. $3100.00 ~---~-.-.--~-~'--~-'--~-.~_:~~,--------,----~-----~,------~~-_.~-----~------- Council District, 2 Census Tract '-'~""''''' Construction Sq Feet Inspections Type Requi red Residence [X] ~onin9 Foundation [ ] Business []Ttpe Framing [] other [ ) Insulation [ ] New [ ] PI umhing [] Repair [~J Status Mechanical [ ]. Remodel [] Code Wallboard []' -'-'.- -~..'~~~.'.. ~..:...' ~...~i.:..""~,,,.' ..._JJ11..._.... -.' '.-.','.-. ..--...:---------....-. .-. --.--..~...-. =-.'-':'--.-., --:....=.. ~.::..----...;.,........-..-[.~.. ~.-. - " : I Hece! ve~ By: . . . '.. . ';. . Approved By : __" /l' r; {r 'f ---------,~- - ...- '. -.--------.-,--.-------------------- --'--------- ._-~, -~.-------- --------------------------.------.----~----c------l----. -,--~--- .-- ___.u ~_.._... "~__"..,.__,__~,,~~_F~__ mr~"-;:'~<il,'~:,1,:~'~--- ~---,~-- -,--,~-~,'~' ,~- -~,---- ~------- --'~"I ~;, , I " ,,~ I , ,\ ,~"~ ,jl ~ ~' ',-~ '~ I BREMERfOI :a U II. D 1 ~ G DEPAR'tMitJ~' I 1 ~ " _~, .-,1. I ~!CEIPT # 08416~ !k 'l'bis :l s }fot A Pie!rmH :Ie JuI OS, "1992 I Pel'1Il1 t Fe&s Amount Paid Plan Check Fees Amount Paid I I: rmildill~ $ 63.0!l $ 63.00 I I 6Z~322,.WOl I x:.;-::;:;:~;: ~=::: =';;;~:t ;.".!~:: =.~~;::; [ $ .00 $ .(10 I , '2~345.9300 I I, I -- Ot.h~t' '~e$ " ~O:l'liny Feel Gall Pa:YJIWnt. $ 4.50 other Fees ~, .GO ~ l i Energy Charge I Sht{t sic $ 4.50 64j~237.13 :.::~ :;:r.-:;'~z-=-::: '1'otd FeElS $ 61.50 ]\lI\(nmt Paid $ 6'1.50 Prior Piyml/;1!lt $ .00 aalli~cf!)Due $ ,QO I;' ==:=:=z=;:~=.=:;=~==::= $ 63.00 $ 63.00 R$cei,~d From: On G1/QS/199:2 ,tmlOvattlle DfllJigfi #541 For inAP\i5394 ""....,,'""""'", ....t",...,.,,:.~.....t........~__,.....,,''''''.......~w....r1'''''''_"'.....~''........L~'''.~'-'h'''''..,.,.....'_"'_"";"'!'~."""'''''''~_''''' ""....-,w''''""......,,,.,,..,''''''..,.~..,,.''-...,.,...,~.~c....,.....~,'~,..,...'''...,,''''_,>"''''''''"""".!-."" ,""",...-"". ........-..-..,."II'<"~"."'J,,,"",..... -, \ ,I ,'< ~, '~', ' ,-' .- " . .. INSPECTION RECORD CARD CITY OF BREMERTON BUILDING DEPARTIJENT 13503 PERMIT NUMBER ADDRESS 1320 BRADLEY STREET OWNER MADALINE ROOD PHONE I CONTRACTOR INNOVATIVE DESIGN, AND DEV. PHONE ; FOUNDA liON ~ 1. PERMIT ON SITE 7. CHECK FOR FILL 2. CHECK PLANS TO PERMIT B. REQUIRED STEEL IN PLACE 3. CHECK SETBACKS 9. CHECK FIREPLACE FOOTING 4. PROPERTY STAKES 10. ANCOR BOLTS 5. FOOTING WIDTH & DEPTH 11. FOUNDATION VENTS 6. SOIL BEARING O.K. 12. CRAWL ACCESS . COMMENTS: FOUNDATION INSPECTION APPROVED BY: 2A FRAMING 20. FIREBLOCKING STAIRS 1.WIRING APPROVED DROP CEILINGS 2.FOUNDATION VENTS TUBS OR SHOWERS 3. SHIELD UNDER POSTS ROOF & CEILING LINES 4. POSITNE CONNECTIONS FURRED OUT AREAS 5. SOIL TO WOOD CLEARANCE FIREPLACE AT CEILINGS 6. BEAM SUPPORT HOLES PLUGGED TOP & BOITOM 7. TA. MAT. NEXT TO CONC. LID IN VOIDS B. WASHERS ON ANCHOR BOLTS 21. WINDOWS 9. BEAMS PROPER SIZE MEETS ENERGY CODE CLASS 10. FLOOR JOIST SPAN SAFETY GLAZING 11. NOTCHING & DRILLING REQUIRED ARE EXITS 12. STAIRS WINDOW SILL HEIGHT WIDTH 22. CEILING HEIGHTS RISE & RUN 23. SWAY BRACING WINDERS 24. TRUSSES LANDINGS PROPERLY INSTALLED , HEADROOM STAMPED 13. AITIC VENTILATION (upper & lower) PROPERLY BRACED 14. CHIMNEY STRAPS SECURED 25. A TIIC ACCESS 15. FIREPLACE COMBUSTION AIR 26. RAFTER & JOIST SPAN 16. FANS VENTED TO OUTSIDE 27. ROOFING, FLASHING, SHEATHING 17. WATER CLOSET CLEARANCE 28. SIDING 18. SMOKE DETECTOR 19. SHEETROCK BACKING COMMENTS: UNDER STAIRS ABOVE GARAGE DOOR HANGERS i ' FRAMING INSPECTION , APPROVED BY: - 23 INSULA liON COMMENTS: 1. PROPER R~VALUE 2. VAPOR BARRIER 3. PROPER FASTENING INSULATION INSPECTION APPROVED BY: , ~v_ MECHANICAL HVAC APPROVED BY: ~ ,.,. 1. PERMIT ISSUED GAS PIPING APPROVED BY: 2. FURNACE LOCATION 3. FURNACE CLEARANCE WDST 4. 'B' VENT SIZING 5. 'B' VENT CLEARANCE 1. WOOD STOVE CLEARANCE 6. 'B' VENT SUPPORT 2. CHIMNEY CLEARANCE 7. COMBUSTION AIR 3. HEARTH EXTENSION 8. DUCT SIZING 9. DUCT SUPPORT & JOINTS 4. CHIMNEY HEIGHT 10.GAS PIPING TEST WDST APPROVED BY: 11. GAS PIPE SIZING 12. GAS PIPE SUPPORT COMMENTS: J PLUMBING - 1. PERMIT ISSUED 6. PROPER FTTTINGS 2. UNDER TEST 7. REQUIRED CLEANOUTS 3. WATER PIPE SIZING B. PROPER GRADE 4. DVN SIZING 9. HWT PRES. RELIEF VALVE & LINE 5. PROPER SUPPORT 10. SEISMIC STRAP COMMENTS: UNDERGROUND APPROVED ROUGH-IN APPROVED BY: BY: 3 WALLBOARD 6. ARE SEPARATION IN GARAGE 1. LID OVER SIDES 7. Arnc ACCESS 2. NAILING 8. DRAFT STOP IN ATTIC 3. W/R AT TUB OR SHOWER 9. PROPER CONST. OF FIRE WALLS 4.5/8 UNDER STAIRS 10. DROP CEILING & LIGHTING 5. FURNACE ENCLOSURE COMMENTS: WALLBOARD APPROVED BY: L. FINAL .... 1. HANDRAILS 9. HOTWATEA TANK PAL 2. GUARDRAILS 10. OUTSIDE GRADE HEIGHT 11. SOIL TO SIDING CLEARANCE INTEAMEDIA TE 12. SMOKE DETECTORS 3. EXHAUST FANS 13. FIREPLACE HEARTH 4. WATERPROOFING IN SHOWERS 14. SAFETY GLAZING 5. DISHWASHER AIRGAP 15. INSULATION 6. FIRE DOORS WINDOWS MEET ENERGY CODE LABLED AS REQUIRED UNDERFLOOR & AlTICE INSUL. SELF CLOSING WATER PIPE & HEAT DUCTS 7. FIRE DAMPERS INSTALLED 16. WOODSTOVE APPROVED 8. PENETRATIONS IN FIRE WALLS 17. WINDOWS & DOORS CAULKED FINAL PLMB. APPR, (comm.) COMMENTS: FINAL MECH, APPR. (comm~ . ~ FINAL BUILDING APPA. 1. ~. , /7 f~ i .... - - - - - ~